• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
292

Caracterização química de fases cristalográficas e física dos cimentos MTA Fillapex, AH Plus, Sealer 26 e Endofill / Chemical and physical characterization of the cements MTA Fillapex, AH Plus, Sealer 26 e Endofill

Ary Gomes da Motta Junior 29 November 2011 (has links)
O objetivo desta pesquisa consiste em analisar através da caracterização química de fases cristalinas a composição e estrutura; e com a caracterização física a densidade, porosidade e área superficial dos seguintes cimentos endodônticos: MTA Fillapex, AH Plus, Sealer 26 e o Endofill. Para tal, foram realizadas análises dos cimentos antes da manipulação (pó e pastas) e depois da manipulação (corpos de prova). Empregando-se as técnicas de caracterização química: DRX e FRX e como técnicas de caracterização física: Picnometria de Hélio, a porosimetria de mercúrio, distribuição granulométrica e área superficial pela metodologia de BET. A caracterização química detalhou a composição dos cimentos sendo compatível com a descrição do fabricante e forneceu a quantificação das suas fases. A caracterização física mostrou que o MTA Fillapex apresentou os melhores resultados: a menor porosidade, o menor volume médio e o menor diâmetro do poro, o Sealer 26 dentre os cimentos resinosos apresentou o pior resultado, o Endofill mostrou-se melhor que o Sealer 26 tendo a maior densidade, o menor diâmetro das partículas, a distribuição granulométrica mais homogênea comparando-se a este. Os cimentos a base de resina mostraram um diâmetro do poro menor que o Endofill. Estes resultados podem estar ligados diretamente aos requisitos de um material obturador ideal. A metodologia utilizada produziu um detalhamento das características químicas e físicas dos cimentos estudados, mostrando um caminho para novas pesquisas na área. / The objective of this research is to examine through characterization chemical composition and crystallographic phase structure and the physical density, porosity and surface area of root canal sealers: MTA Fillapex, AH Plus, Sealer 26 and Endofill. To this end, we performed analysis of cements before handling (powder or paste) and after manipulation (specimens), employing the techniques of chemical characterization: DRX and FRX and physical characterization: Helium Picnometry, mercury porosimetry, granulometric distribution and surface area by BET method. The chemical characterization detailed the composition of the cements being compatible with the description of the manufacturers and provided the quantification of the phases. The physical characterization showed that MTA Fillapex presented the best results: the lowest porosity, the smallest average volume and the smallest pore diameter; Sealer 26 among the resinous cements presented the worst result; Endofill proved to be better than Sealer 26 having the highest density, the smallest diameter of the particles , and homogeneous granulometric distribution equal to it. The resin-based cements showed a pore diameter smaller than Endofill. These results may be connected directly to the requirements of an ideal endodontic filling material. The methodology used outlined the physical and chemical characteristics of the cements studied, laying the ground to new researches in the area.
293

Efeito do momento de fotoativação nas propriedades de cimentos resinosos experimentais de dupla ativação com diferentes concentrações de carga

Oliveira, Ana Carla de Assunção 26 January 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The reduction of shrinkage stress of resin cements, without loss of their mechanical properties, is essential to longevity of adhesive luting procedures. It has been demonstrated that the delayed light-curing of dual-cured resin cements reduces the shrinkage stress. However, the effects of this postponement on mechanical properties showed are dependent form material composition. Thus, the aim of this study was to evaluate the effect of filler content on properties of dual-cured resin cements light-cured immediately or 5 minutes after their mixing. Two light-curing protocols were additionally evaluated, using a single or 3-point of light-activation. For this purpose, only the cement with 65% of filler was used. Experimental dual-cured resin cements were formulated using a monomeric matrix BisGMA/TEGDMA (1:3 in weight) and filled with 60, 65 or 68% of silanated barium borosilicate glass. The viscosity of experimental cements was measured using a digital viscometer. Bar-shaped specimens (25 x 2 x 2 mm) were confectioned, while the light-curing was performed immediately or 5 minutes after the insertion of cements into the mold (n = 7). Three-point bending test was performed and the values of flexural strength and elastic modulus were measured. The fractured specimens (n = 5) were included into epoxy resin cylinders, polished and the Vickers hardness measurement was performed. Data from viscosity were submitted to one-way ANOVA, while the data from mechanical properties were analyzed by two-way ANOVA. All pair-wise comparison were performed using Tukey’s test (α = 0.05). Specimens that were light-cured at 3 points showed the highest values of flexural strength. Only for light-activation at 1 point, the moment of light-activation affected the elastic modulus (higher for delayed). Cements with 68% of filler showed highest viscosity and those with 60% presented the lowest one. Irrespective of light-curing moment, the cement with 65% of filler presented the highest values of flexural strength and elastic modulus. Addition of 60% of filler resulted in the lowest elastic modulus, while 68% of filler resulted in lowest flexural strength. Regarding the hardness, the cement with 68% of filler showed the highest values, while there was no difference between 60 and 65% of filler. In conclusion, the filler content affects the mechanical properties of cements and this effect is independent form moment of light-curing. / A redução da tensão de contração de cimentos resinosos, sem perdas nas suas propriedades mecânicas, é essencial para a longevidade das cimentações adesivas. Tem sido demonstrado que a fotoativação tardia dos cimentos resinosos duais reduz as tensões de contração. Entretanto, a influência desta postergação da fotoativação sobre as propriedades mecânicas mostrou ser dependente da composição do material. Assim, o objetivo deste estudo foi avaliar o efeito da concentração de carga nas propriedades de cimentos resinosos de dupla ativação fotoativados imediatamente ou após 5 minutos de sua manipulação. Cimentos experimentais duais foram manipulados com matriz monomérica BisGMA/TEGDMA (1:3 em massa) com 60, 65 ou 68% de carga (em massa) de partículas silanizadas de bório-alumínio-silicato. A viscosidade dos cimentos experimentais foi avaliada em viscosímetro digital. Dois protocolos de fotoativação foram adicionalmente avaliados, usando um ponto de fotoativação ou 3 pontos, para isto, usou-se apenas o cimento com 65% de carga. Corpos-de-prova em forma de barra (25 x 2 x 2 mm) foram confeccionados, sendo a fotoativação realizada imediatamente ou 5 minutos após a inserção dos cimentos na matriz (n = 7). Ensaio de flexão de três pontos foi realizado e os valores de resistência flexural e módulo de elasticidade foram mensurados. Os corpos-de-prova fraturados foram embutidos (n = 5) em cilindros de resina acrílica, polidos e a leitura de dureza Vickers foi realizada. Os dados de viscosidade foram submetidos à ANOVA de uma via, enquanto que os dados das propriedades mecânicas avaliadas foram analisados por ANOVA de duas vias. Todas as comparações múltiplas foram realizadas com o teste de Tukey (α = 0,05). Amostras fotoativadas em 3 pontos apresentaram maiores valores de resistência flexural. Apenas para a fotoativação em 1 ponto, o momento de fotoativação afetou o módulo de elasticidade (maior para tardia). Os cimentos com 68% de cargas mostraram a maior viscosidade e os com 60% a menor. Independentemente do momento da fotoativação, o cimento com 65% de carga apresentou os maiores valores de resistência flexural e módulo de elasticidade, enquanto que adição de 68% de carga resultou nos menores valores. Já para dureza, o cimento com 68% de carga apresentou os maiores valores, não havendo diferença entre 60 e 65% de carga. Como conclusão, a concentração de carga afeta as propriedades mecânicas dos cimentos e este efeito independente do momento da fotoativação.
294

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz /

Conti, Elaine Cristina Guerbach. January 2006 (has links)
Orientador: José Roberto Cury Saad / Banca: Patrícia dos Santos Jardim / Banca: Luiz Alberto Plácido Penna / Banca: Osmir Batista de Oliveira Júnior / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / Abstract: This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5. / Doutor
295

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro /

Lopes, José Fernando Scarelli. January 2003 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Eunice Teresinha Giampaolo / Banca: João Henrique Nogueira Pinto / Resumo: O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below) / Mestre
296

Análise dos fotoiniciadores presentes em resinas compostas em função da cor /

Alvim, Hugo Henriques. January 2005 (has links)
Orientador: José Roberto Cury Saad / Banca: Rodrigo de Castro Albuquerque / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo deste estudo foi identificar e quantificar os fotoiniciadores utilizados em diferentes marcas comerciais de resinas compostas em função da cor analisada. Foram utilizadas as resinas compostas: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). Foram pesados 500mg de cada resina e dissolvidos em 1,0 ml de metanol. As amostras foram centrifugadas para acelerar a sedimentação das partículas inorgânicas. Foram pipetados 0,8 ml da solução sobrenadante que foi armazenada por 72 horas em estufa a 35º C para total evaporação do metanol. Após este período foi feita a ressuspensão com 0,5 ml de metanol e analisados por cromatografia líquida acoplado ao espectrômetro de massa (GC-MS). Os resultados foram comparados a soluções de canforoquinona pura, utilizada como padrão. O teste de T Student, significativo ao nível de 5%, comparou os resultados entre as cores de cada marca comercial. Observou-se menor quantidade de canforoquinona na cor incisal da resina Filtek Z-250 (FZI) quando comparada a cor A3 (FZA3). Por outro lado, as resinas Tetric Ceram e Filtek Supreme apresentaram quantidade de canforoquinona estatisticamente superior nas cores Incisais (TCT e FSGT). Na resina Pyramid Enamel foi encontrada canforoquinona apenas na cor A1 (PEA1), sendo que o fotoiniciador utilizado na cor Translucent não foi identificado. Baseado nos dados obtidos pode-se concluir que uma mesma marca comercial de resina composta pode apresentar diferenças na quantidade e no tipo de fotoiniciador utilizado. / Abstract: The aim of this study was to identify and quantify the photoinitiators used in different brands of composite resins in function of shade analyzed. It was used the following materials: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). A small portion (500 mg) of each composite resin was dissolved in 1,0 ml of methanol. The samples were centrifuged to accelerate the inorganic fillers sedimentation. An aliquot (0,8 ml) was stored in vials for 72 hours at 35º C for complete methanol evaporation. After this period was added 0,5 ml of methanol and the samples were analyzed by gas-liquid chromatograph associated to mass spectrometer (GC-MS). The results were compared to pure camphorquinone solutions, used as standart. The results between shades of each commercial brand were compared by T Student test significant at 5%. It was noticed statistical difference in the quantity of camphorquinone between the shades of all tested brands. In Pyramid Enamel was found camphorquinone only in the A1 shade (PEA1). The photoinitiator used in Translucent shade was not identified. Based upon the scientific data presented in this study, it was concluded that the same composite resin brand can present differences in the quantity and type of photoinitiator used. / Mestre
297

Avaliação da resistência de união de diferentes sistemas adesivos à dentina bovina : influência de agentes dessensibilizantes /

Lima, Darlon Martins. January 2005 (has links)
Orientador: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: Patricia dos Santos Jardim / Resumo: O objetivo deste trabalho foi o de avaliar comparativamente "in vitro", a resistência de união ao cisalhamento de uma resina composta à dentina bovina em função da combinação de três diferentes sistemas adesivos e de dois diferentes agentes dessensibilizantes. Foram utilizados os sistemas adesivos: Single Bond, Master Bond e Prime & Bond 2.1 e os seguintes agentes dessensibilizantes: o Oxagel e o G. H. F. Dessensibilizador. Para a confecção dos corpos de prova, 90 incisivos bovinos (n=10) foram utilizados, os quais tiveram suas superfícies vestibulares desgastadas, até a exposição dentinária, de tal forma que, a área de adesão padronizada, tivesse 4 mm de diâmetro. Após a realização dos tratamentos de superfície, onde os Grupos controle eram indicados apenas pela aplicação do sistema adesivo, e os Grupos experimentais, pela aplicação dos agentes dessensibilizantes testados após o condicionamento ácido, foram confeccionados cilindros de resina composta Z-100, com o auxílio de uma matriz bipartida. Os corpos-de-prova foram então armazenados em água destilada a 37°C por 24 horas, e submetidos em seguida ao ensaio de cisalhamento, a uma velocidade do atuador de 0,5 mm/min. Os resultados obtidos foram submetidos à análise de variância, e ao teste de Tukey, ao nível de 5% de significância. Observou-se que houve influência dos agentes dessensibilizantes, quando estes eram aplicados na dentina bovina e interagiam com os sistemas adesivos, sendo que o G. H. F. Dessensibilizador aumentou estatisticamente os valores de resistência de união do Single Bond, e do Prime & Bond 2.1, e o Oxagel não influenciou nos valores de resistência de união dos sistemas adesivos testados. / Abstract: The objective of this work was it of evaluating "in vitro" comparatively , the shear bond strength of a resin composed to the bovine dentin in function of the combination of three different adhesive systems and of two different agents dessensitizers. The adhesive systems were used, to know: Single Bond, Master Bond and Prime & Bond 2.1 and the following agents dessensitizers: Oxagel and G. H. F. Desensitizer. For the making of the test bodies, 90 incisive bovine (n=10) they were used, which had its worn away vestibular surfaces, until the exhibition dentin, in such a way that, the area of standardized adhesion, had 4 diameter mm. After the accomplishment of the surface treatments, where the Groups control was just suitable for the application of the adhesive system, and the experimental Groups, for the application of the agents dessensitizers tested after the acid conditioning, cylinders of composed resin were made Z-100, with the aid of a bipartite matrix. The test bodies, they were stored then in water distilled for 37°C by 24 hours, and submitted soon after to the shear bond strength rehearsal, to a crosshead speed of 0,5 mm/min. The obtained results were submitted to the variance analysis, and to the test of Tukey, at the level of 5% of significance. It was observed that there was influence of the agents dessensitizers, when these were applied in the bovine dentin and interagiam with the adhesive systems, and G. H. F. Dessensitizer increased statistically the values of resistance of union of Single Bond, and of the it Prime & Bond 2.1, and Oxagel didn't influence in the values of resistance of union of the tested adhesive systems. / Mestre
298

Avaliação das propriedades mecânicas e químicas em função de diferentes cimentos resinosos e pinos não-metálicos /

Bandéca, Matheus Coelho. January 2009 (has links)
Resumo: Este estudo objetivou: (1) testar a hipótese que a utilização de pinos nãometálicos em dentes tratados endodonticamente está associado a longevidade da restauração através de uma revisão sistemática; (2) avaliar o grau de conversão de dois cimentos resinosos em diferentes tempos após a fotoativação; (3) avaliar a resistência adesiva de diferentes cimentos resinosos usando dois pinos não-metálicos; (4) e avaliar a resistência a fratura e padrão de falha de dentes submetidos ao clareamento dental interno usando peróxido de hidrogênio a 35% restaurados com diferentes procedimentos. No artigo 1, 157 artigos participaram do estudo e após os critérios de inclusão-exclusão, restaram apenas 5 artigos. Para o artigo 2, vinte espécimes foram confeccionados para cada cimento, Panavia® F2.0 e RelyXTM Unicem Applicap. Cada espécime foi curado com luz LED e foram analisados imediatamente, 24 horas, 48 horas e 7 dias após a fotoativação. Os testes usados foram grau de conversão (FT-IR) e termogravimetria. No artigo 3, oitenta dentes pré-molares unirradiculares livres de coroas foram usados e divididos em 8 grupos: os pinos Exacto! e Everstick! foram cimentados com Breeze!, Nexus! 3, Panavia! e Bistite!. Os dentes foram obturados e preparados para cimentação dos pinos não-metálicos. Cada espécime foi perpendicularmente seccionado em aproximadamente 1 mm de espessura em 6 discos e divididos em região ! cervical, médio e apical. No artigo 4, oitenta dentes incisivos inferiores foram usados e metade foram clareados. Os dentes foram restaurados com resina composta, pinos de resina reforçado com fibra e pinos de fibra de vidro. Os pinos foram cimentados com Breeze! e Panavia!. Os espécimes foram submetidos ao teste de resistência a fratura pela máquina de testes universal. Todos os dados foram submetidos ao devido tratamento estatístico. Os pinos usados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed: (1) To test the hypothesis that the placement of nonmetallic post in endodontically treated teeth is associated with improved survival rate of the restored teeth althouth systematic review; (2) to evaluate the degree of conversion of two resin cements in differents times after light-activated; (3) to evaluate the microtensile bond strength of different resin cement systems using two nonmetallic posts; (4) to evaluate the fracture resistance and failure pattern of endodontically treated teeth after intracoronal bleaching using 35% hydrogen peroxide with different restorative procedures. For the article 1, 157 papers were used and after the inclusion-exclusion procedure, only 5 papers remained. For the article 2, twenty specimens were made for each cement, Panavia® F2.0 and RelyXTM Unicem Applicap. Each specimen were cured with LED and were tested immediately, 24 hours, 48 hours and 7 days after light-activated. The tests used were degree of conversion (FT-IR) and thermogravimetric. For the article 3, eighty single-rooted human mandibular first premolar free crown were used and divided into 8 groups: Exacto! and Everstick! posts were cemented with Breeze!, Nexus! 3, Panavia! F 2.0 and Bistite! II DC. The teeth were obtured and prepared for cementation of the nonmetallic posts. Each specimen were perpendicularly sectioned into approximately 1 mm thick sections resulting in 6 serial slices and divided in cervical, meddium and apical region. For the !article 4, eighty mandibular incisors were used and the half teeth were bleached. The teeth were restored with composite resin, fiber-reinforced composite post and glass fiber post. The posts were cemented with Breeze! and Panavia!. The specimens were submitted to the fracture resistance test by universal test machine. Statistical analyses were performed for each article. The posts used... (Complete abstract click electronic access below) / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Omar El-Mowafy / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Roberto Cury Saad / Banca: Darlon Martins Lima / Mestre
299

Avaliação da resposta tecidual e citotoxicidade dos cimentos : Ângelus MTA cinza e CPM . cimento Portland modificado /

Faria, Max Douglas. January 2010 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Robson Frederico Cunha / Banca: Marco Antonio Húngaro Duarte / Banca: Roberta Okamoto / Banca: João Eduardo Gomes Filho / Resumo: O objetivo deste estudo foi avaliar a resposta tecidual do tecido subcutâneo de rato ao implante de tubos de polietileno preenchidos com CPM ® (Cimento Portland Modificado) comparado com Ângelus MTA ® . Estes materiais foram colocados em tubos de polietileno e implantados no tecido conjuntivo dorsal de ratos Wistar por 7, 15, 30, 60 e 90 dias. Os espécimes foram preparados para serem corados com HE, Von Kossa ou não corados para luz polarizada. Foi realizada análise qualitativa e quantitativa da reação inflamatória. Os materiais CPM ® e Ângelus MTA ® causaram reação moderada no tempo experimental de 7 dias que diminuiu com o tempo. A resposta foi similar entre os grupos Controle, CPM ® e Ângelus MTA ® no tempo experimental de 30 dias. Aos 60 e 90 dias todos os grupos foram semelhantes ao Controle. Mineralizações e granulações birrefringentes à luz polarizada foram observadas com ambos os materiais. Podese concluir que o CPM ® apresentou resposta tecidual semelhante ao Ângelus MTA ® inclusive com estimulação de formação de tecido mineralizado / Abstract: The aim of this study was to evaluate the tissue response of rat subcutaneous tissue implantation of polyethylene tubes filled com CPM® (Portland Cement Modified) compared with Angelus MTA ®. These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of rats by 7,15,30,60 and 90 days. The specimens were prepared to be stained with HE, Von Kossa staining or without starning for polarized light. It were performed qualitative and quantitative analysis of reactions inflammatory. CPM materials ® and Angelus MTA ® caused a moderate reaction in the experimental period of 7 days decreased with time. The response was similar between control, CPM® and Angelus MTA ® in the experimental time of 30 days. At 60 and 90 days all groups were similar to control. Mineralization and granulations birefringent to polarized light were observed with all materials. It was possible that CPM® presented similar tissue response to Angelus MTA ® Iinduding with mineralized tissue stimulation / Doutor
300

Efeito de material cimentante e do tempo na resistência adesiva de pinos de fibra de vidro /

Campos, Leonardo Maciel. January 2007 (has links)
Orientador: Maria Salete Machado Candido / Banca: Abraham Lincoln Calixto / Banca: Luiz Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar in vitro a resistência à tração de pinos de fibra de vidro cimentados em raízes de dentes bovinos com quatro agentes cimentantes em dois períodos de tempo de armazenamento em saliva artificial: com 48 horas e após 240 dias. Para tal, foram utilizadas 80 raízes de dentes bovinos que, após tratamento endodôntico, foram divididas em 8 grupos com 10 raízes para cada grupo. Para a fixação dos pinos foram utilizados 4 diferentes agentes cimentantes sendo que, os quatro primeiros grupos foram armazenados em saliva artificial por 48 horas antes do teste de tração; a saber: Grupo I - cimento resinoso dual (Rely X e Adper Single Bond-3M/ESPE), Grupo II - cimento de ionômero de vidro (Bioglass "C"- BIODINÂMICA), Grupo III - cimento de fosfato de zinco (SS WHITE), Grupo IV - cimento resinoso quimicamente ativado (CB Cement e One-Step/ BISCO). Os outros 4 Grupos (V, VI, VII e VIII) receberam os mesmos agentes cimentantes citados acima e na mesma seqüência porém, armazenados em saliva artificial por 240 dias antes da realização do teste de resistência à tração em uma Máquina de Ensaio Universal (VERSAT 500) à velocidade de deslocamento de 1,0 mm/min. Os dados foram catalogados e submetidos à análise estatística mediante os testes Análise de Variância, Tukey e t-student. Os resultados mostraram após 48 horas de armazenamento, o comportamento dos Grupos em estudo e podem assim ser representados: G IV > G III > G I > G II, no entanto, após 240 dias: G VIII = G VII  G VI  G V; concluindo que: a resistência à tração de pinos de fibra de vidro; cimentada em raízes bovina, foi influenciada com o tempo, pois, quanto maior o tempo de envelhecimento, menor é o valor da resistência, com exceção do cimento de ionômero de vidro. / Abstract: The purpose of the present investigation was to assess the in vitro tensile bond strength resistence of fiberglass posts retained with different cementing agents in bovine teeth at different time points, upon incubation with artificial saliva. To that end, eighty roots harvested from bovine teeth received endodontic treatment and were split into 8 groups (10 roots per group). The fiberglass posts were retained with four different cementing agents, and the first groups were incubated with artificial saliva 48 hours before the tensile test. The groups were distributed as follows: Group I - dual resin cement (Rely X e Adper Single Bond-3M/ESPE), Group II - glass ionomer cement (Bioglass "C"- BIODINÂMICA), Group III - zinc phosphate cement (SS WHITE) and Group IV - chemically activated resin cement (C&B Cement e One -Step/BISCO). The remaining four groups (V, VI, VII and VIII) were accordingly treated with the same cementing agents and conditions, except for the fact that they were incubated with artificial saliva for 240 days before being subjected to the tensile test using a Universal Testing Machine (VERSAT 500) at 1.0 mm/min. The data generated were collected and subjected to statistical analysis through ANOVA, Tukey post-hoc and Student-t tests. After 48 hours of incubation in artificial saliva, the outcome can be presented as follows regarding the traction test: G IV > G III > G I > G II. On the other hand, after 240 days of incubation the outcome was G VIII = G VII  G VI  G V. The findings allow us to state that the tensile bond strength of fiberglass posts cemented in bovine teeth roots was affected by the variable time because the longer the aging the lower is the resistance, except the glass ionomer cement. / Doutor

Page generated in 0.0947 seconds