• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Caracterização físico-química, mecânica e biológica de cimento autoadesivo aditivado com nanotubos de dióxido de titânio / Physical-chemical, mechanical and biological characterization of reinforcement self-adhesive resin cement titanium dioxide nanotubes

Tonello, Carla Müller Ramos 28 November 2016 (has links)
O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas. / The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.
312

Análise não-linear do mecanismo de cimentação de pinos intra-radiculares utilizando o método dos elementos finitos / NO-LINEAR ANALYSIS OF CEMENTATION MECHANISM IN ROOT POSTS USING THE FINITES ELEMENTS METHOD

Franco, Ana Paula Gebert de Oliveira 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:08Z (GMT). No. of bitstreams: 1 Ana Paula Gebert.pdf: 9068136 bytes, checksum: 8f06dbf649af9345afc6e09a57f71fb6 (MD5) Previous issue date: 2008-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim is to analyze a non-linear mechanism of the cementation of root posts considering the existence of gaps in cement-dentin and cement-post interfaces analyzing the correlation of mechanical test and computational model. Were selected 15 mandibular pre-molars, to receive root posts Exacto (Angelus®/Londrina - Brazil) fixed with chemical resin cement Cement-Post (Angelus®/Londrina - Brazil). The teeth were termocycled, radiographed and cuted themselves getting cervical, middle and apical discs of roots. These discs were treated and molded with addition of silicone and epoxy resin replics was obtained before and after the compression test (220 N-0, 2 mm / min). The replics were analyzed in MEV to observe the formation of gaps at the interfaces on the upper surfaces of the specimens, which were measured in the Image Tool program. For statistical analysis of the comparison between the mensures of gaps (μm) in the interface was used in the Wilcoxon test which showed that there were statistical differences between groups (p <0.0001). In the comparison between the mensures of gaps in the same interface of the cervical, middle and apical discs before and after the compression test, there was no statistically significant difference (p = 0.4304) and (p = 0.7766), respectively. In cement-post interface there was no gaps in most specimens. The dentin discs were photographed and their images obtained from three-dimensional models simulating the compression test using the Finite Elements Method, considering linear-elastic material with values of module of elasticity and Poisson's coefficient, and obtained in the mechanical test of the traction, compression and bending resistance in the post and/or the cement. There was the Poisson's effect and a low stress concentration in dentin-cement and cement-post interfaces promoted by the force application, geometry and materials properties. In assessing the match of the mechanical test with the computational model, met a difference because of the consideration of perfect adhesion in computational model of the cervical and middle discs, which does not occur clinically, as there was formation of gaps in some root regions of the dentin discs. The apical discs were modeled like non-linear and it was considered an area of contact between the faces. / O objetivo é analisar de forma não-linear o mecanismo de cimentação de pinos intra-radiculares considerando a existência das fendas nas interfaces dentina-cimento-pino analisando a correspondência do ensaio mecânico e modelo computacional. Foram selecionados 15 pré-molares inferiores, para receber pinos intra-radiculares Exacto (Angelus®/Londrina - Brasil) fixados com cimento resinoso autopolimerizável Cement-Post (Angelus®/Londrina - Brasil). Os dentes foram termociclados, radiografados e cortados obtendo-se discos cervicais, médios e apicais das raízes. Esses discos foram tratados e moldados com silicone de adição e obtidas réplicas de resina epoxi antes e após o ensaio de compressão (220 N-0,2 mm/min). As réplicas foram analisadas em MEV para observar a formação de fendas nas interfaces nas faces superiores dos espécimes, as quais foram medidas no programa Image Tool. Para análise estatística da comparação entre as medidas de fendas (μm) na interface foi utilizado o teste Wilcoxon que demonstrou que houve diferenças estatísticas entre os grupos (p < 0,0001). Na comparação entre as medidas de fendas da mesma interface dos discos cervical, médio e apical antes e depois do ensaio de compressão, não houve diferenças significantes estatisticamente (p = 0,4304) e (p = 0,7766), respectivamente. Na interface cimento-pino observou-se ausência de fendas na maior parte dos espécimes. Os discos de dentina foram fotografados e a partir de suas imagens obtidos modelos tri-dimensionais analisados simulando-se o ensaio de compressão por meio do Método dos Elementos Finitos, considerando material elástico-linear com valores de módulo de elasticidade e Coeficiente de Poisson e, obtidos de ensaios mecânicos de resistência à tração, compressão e flexão realizados no pino e/ou no cimento. Observou-se o efeito Poisson e que houve uma concentração leve de tensões nas interfaces dentina-cimento e cimento-pino promovidas pela forma de aplicação da força, geometria e propriedades dos materiais. Na avaliação da correspondência do ensaio mecânico com o modelo computacional, encontrou-se uma diferença devido à consideração de adesão perfeita no modelo computacional dos discos cervicais e médios, o que não ocorre clinicamente, visto que houve formação de fendas em algumas regiões radiculares dos discos de dentina. Os discos apicais foram modelados de maneira não-linear, considerando-se uma superfície de contato entre as faces.
313

Estudo comparativo da citotoxicidade de cimentos obturadores sobre culturas de células endoteliais da linhagem ECV 304 / Comparative study of cytotoxicity of sealers on cultured endothelial cells line ECV 304

Vagner José Medeiros Martins 15 February 2011 (has links)
Este estudo teve como objetivo avaliar, in vitro, a citotoxicidade dos cimentos endodônticos Densell Endo, Pulp-Fill, Endofill, Sealer 26, Pulp Canal Sealer e GuttaFlow após 12, 24 e 72 horas de tempo de contato, utilizando-se uma linhagem de células endoteliais ECV-304. Para a avaliação da viabilidade celular, utilizou-se o teste de citotoxicidade MTT. Para cada cimento foram preparados 12 corpos de prova que foram distribuídos em seis grupos experimentais de acordo com as marcas comerciais, sendo quatro para cada tempo. Foi criado um grupo controle que não foi submetido à ação de cimento. Para avaliação do efeito dos cimentos sobre as células endoteliais, os corpos de prova foram inseridos nos poços da placa cultura, incubados a 37C em presença de 5% de CO2 e 100% de umidade. Os testes MTT foram realizados, em quadruplicata, após 12, 24 e 72 horas de contato das amostras com o tapete celular. Foi utilizada a prova Two-Way Anova com o teste Post Hoc de Bonferroni com nível de significância de 5%. Na análise de 12 horas, foi possível observar que o cimento GuttaFlow apresentou média de absorbância de 0,055, seguido do Sealer 26 (média = 0,038). Os cimentos Pulp Canal Sealer e Densell Endo apresentaram a mesma média de absorbância (0,031). O Pulp Fill e o Endofill foram os cimentos que apresentaram maior citotoxicidade (média de absorbância = 0,024 e 0,021, respectivamente). O grupo controle apresentou média de absorbância de 0,158. Em 24 horas observou-se que os cimentos GuttaFlow e Sealer 26 apresentaram as maiores médias de absorbância (0,041 e 0,037, respectivamente), seguidos pelo cimento Pulp Canal Sealer que apresentou média de absorbância de 0,035. Já os cimentos Densell Endo e Pulp Fill apresentaram médias de absorbância de 0,033 e 0,032, respectivamente. O cimento Endofill apresentou uma média de 0,026 e o grupo controle de 0,086. Quando analisados em 72 horas, o cimento Pulp Canal Sealer obteve média de absorbância de 0,049, seguido dos cimentos GuttaFlow e Pulp Fill, ambos com 0,048. Os cimentos Densell Endo, Sealer 26 e Endofill apresentaram respectivamente, médias de 0,044, 0,040 e 0,036. O grupo controle diferenciou-se significativamente de todos os grupos em todos os tempos. Quando analisadas as médias gerais de absorbância dos grupos analisados observou-se que o cimento GuttaFlow se apresentou como o cimento com menor índice de citotoxicidade, apresentando média de absorbência de 0,048. Logo após, apresentando médias de absorbância iguais (0,038) encontraram-se os cimentos Pulp Canal Sealer e Sealer 26; seguidos do Densell Endo e do Pulp Fill, com 0,036 e 0,035, respectivamente. O grupo controle apresentou média de absorbância de 0,098. Portanto, tendo como base os resultados obtidos, pôde-se concluir que o cimento Endofill foi o que apresentou maior citotoxicidade e o cimento GuttaFlow, o menos citotóxico. / This study aimed to evaluate, in vitro, cytotoxicity of root canal sealers Densell Endo, Pulp-Fill, Endofill, Sealer 26, Pulp Canal Sealer and GuttaFlow after 12, 24 and 72 hours of contact time, using a endothelial cell line ECV-304. For the assessment of cell viability, used the MTT cytotoxicity test. For any cement were prepared 12 specimens that were divided into six groups according to the trademarks, four for each time. Created a control group that was not subjected to action of cement. To assess the effects of cements on endothelial cells, the specimens were placed in culture plate wells, incubated at 37C with 5% CO2 and 100% humidity. MTT tests were performed, in quadruplicate, after 12, 24 and 72 contact hours of the samples with monolayers. Was used to test Two-Way Anova with Bonferroni Post Hoc test with significance level of 5%. In the analysis of 12 hours, was observed that the cement GuttaFlow had a mean absorbance of 0,055, followed by Sealer 26 (average = 0,038). Cements Pulp Canal Sealer and Densell Endo had the same mean absorbance (0,031). The Pulp Fill and Enfofill were the cements with higher cytotoxicity (mean absorbance = 0,024 and 0,021, respectively). The control group had a mean absorbance of 0,158. In 24 hours it was observed that the cements Sealer 26 and GuttaFlow had the highest average absorbance (0,041 and 0,037, respectively), followed by cement Pulp Canal Sealer that had a mean absorbance of 0.035. Already cements Densell Endo and Pulp Fill showed means absorbance of 0,033 and 0,032, respectively. Cement Endofill&#61650; showed an average of 0,026 and the control group, 0,086. When analyzed at 72 hours, the cement Pulp Canal Sealer had an average absorbance of 0,049, followed by cement GuttaFlow and Pulp Fill, both with 0,048. Cements Densell Endo, Sealer 26 and Endofill showed respectively, averaging 0,044, 0,040 and 0,036. The control group differed significantly from all groups at all times. When analyzing the overall means of absorbance groups analyzed showed that the cement GuttaFlow introduced himself as the cement with a lower index of cytotoxicity, with a mean of 0,048 absorbance. Soon after, with averages of equal absorbance (0,038) met cements Pulp Canal Sealer and Sealer 26; followed by Endo Densell and Pulp Fill, with 0,036 and 0,035, respectively. The control group had a mean absorbance of 0,098. Therefore, based on the results, could conclude that the cement Endofill showed the highest cytotoxicity and cement GuttaFlow, the least cytotoxic.
314

Citotoxicidade e genotoxicidade de cimentos endodônticos /

Bin, Claudia Villela. January 2011 (has links)
Resumo: O MTA é um cimento amplamente utilizado na endodontia devido ao potencial indutor da mineralização, sendo empregado em procedimentos de proteção do complexo dentino/pulpar, retrobturação, perfurações radiculares e de furca e em dentes com rizogênese incompleta. Inicialmente esse material não foi preconizado como cimento obturador de canais radiculares. Entretanto, recentemente foi criado um cimento endodôntico resinoso contendo MTA (MTA Fillapex) com essa indicação, porém não há estudos sobre este novo material. Como o MTA é utilizado sobre os tecidos periodontal, ósseo e pulpar, é importante conhecer seus efeitos citotóxicos e genotóxicos, uma vez que, alguns cimentos endodônticos podem liberar componentes tóxicos, prejudicando o processo de regeneração e reparação dos tecidos no qual entram em contato. Assim, o objetivo deste trabalho foi avaliar a citotoxicidade e genotoxicidade do MTA obturador (Fillapex) comparando-o com o MTA reparador e com o AH Plus. Fibroblastos de hamster Chinês (V79) foram colocados em contato com diferentes diluições de meios de cultura previamente expostos a esses materiais. A citotoxicidade foi avaliada através do ensaio de MTT, em espectrofotômetro, para a verificação da taxa de viabilidade celular. A genotoxicidade foi avaliada pela formação de micronúcleos (MNT), para detecção de mutações cromossômicas. A taxa de sobrevivência celular e o número de micronúcleos antes e após a exposição aos cimentos foram estatisticamente analisados pelo teste de Kruskal-Wallis e teste de Dunn (p<0,05). Os resultados mostraram que o MTA reparador manteve a viabilidade celular acima de 50% em todas as diluições. Porém, tanto o MTA Fillapex quanto o AH Plus foram altamente citotóxicos e capazes de aumentar a formação de micronúcleos em 8 vezes em relação ao grupo controle na diluição 1:4, mostrando que são cimentos cito e genotóxicos / Abstract: The MTA is a sealer widely used in endodontics and for be considered a material that inducing mineralization, can be used in procedures for protection of dentin/pulp complex, retrofilling root and furcal perforations and in teeth with incomplete root formation. Initially this material was not recommended as root canal sealer. However, recently a resin sealer based on MTA (MTA Fillapex) was created for this indication, but there are no studies on this new material. As the MTA is used on the periodontal tissues, bone and pulp, it is important to know the cytotoxic and genotoxic effects, as some sealers can release toxic components, impairing the process of regeneration and repair of tissues in which they come into contact. Thus, the purpose of this study was to evaluate the cytotoxicity and genotoxicity of MTA obturator (Fillapex) comparing it with the MTA repairer and AH Plus. Chinese hamster fibroblasts (V79) were placed in contact with different dilutions of culture media previously exposed to such materials. Cytotoxicity was evaluated by MTT assay in spectrophotometer to check the viability rate and cell survival. The genotoxicity was evaluated by micronucleus (MNT) to detect chromosomal mutations. The cell survival rate and number of micronuclei before and after exposure to the cement were statistically analyzed by Kruskal-Wallis and Dunn test (p<0.05). The results showed that MTA reparative remained cell viability above 50% in all dilutions. However, both the MTA Fillapex and AH Plus were highly cytotoxic / Orientador: Marcia Carneiro Valera / Coorientador: Samira Esteves Afonso Camargo / Banca: Caio Cézar Randi Ferraz / Banca: Ana Paula Martins Gomes / Mestre
315

Restaurações inlays em cerâmicas feldspáticas injetadas em pré-molares : efeito da estratégia de cimentação e da ciclagem mecânica na resistência adesiva entre dentina e restauração /

Feitosa, Sabrina Alves. January 2011 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Francisco Cesar / Banca: Luiz Felipe Valandro Soares / Resumo: O estudo avaliou o efeito da estratégia de cimentação e da ciclagem mecânica na resistência de união entre dentina e restauração. O tipo de falha dos espécimes foi classificado e a distribuição de tensões foi analisada pela simulação utilizando o método de análise por elementos finitos (MEF). Quarenta e oito (N= 48) pré-molares superiores foram preparados (cavidade tipo MOD) e 48 restaurações inlays de cerâmica feldspática foram obtidas. Os espécimes foram alocadas em 3 grupos, considerando a estratégia de cimentação (N= 16): 1- convencional (Grupos 1 e 2): sistema adesivo condicionamento total de passo único (tratamento da dentina), tratamento da superfície cerâmica com ácido fluorídrico (HF) e silano (S), e cimentação com cimento resinoso; 2- estratégia simplificada (grupos 3 e 4) utilizando o cimento resinoso autoadesivo RelyX U100 (3M) sem tratamento das superfícies da dentina e da cerâmica; 3- estratégia simplificada modificada (grupos 5 e 6) utilizando o cimento resinoso RelyX U100 associado ao tratamento de superfície com HF+S. Os dentes dos grupos 2, 4 e 6 não foram ciclados, enquanto que aqueles dos grupos 1, 3 e 5 foram submetidos a ciclagem mecânica (CM): 2.000.000 pulsos, carga de 100N sobre as cúspides (a restauração não recebeu carga), a 37 oC. Cada espécime foi seccionado de forma seriada para produzir corpos de prova em forma de barras dente-restauração-dente para serem submetidas ao teste de microtração. A região da fratura de cada espécime foi analisada e classificada. A distribuição de tensões em um modelo virtual simulando as condições do estudo in vitro, pelo método de elementos finitos, foi verificada. A Análise de Variância mostrou que: o efeito interação dos fatores não foi estatisticamente significante (a alteração da resistência de união em razão da ciclagem mecânica (CM) para a Estratégia ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study evaluated the effect of the bonding strategy and mechanical cycling on the bond strength between dentin and inlay restoration. The specimens failure mode and stress distribution (Finite element analysis FEA) was analyzed. Forty-eight (n = 48) pre-molars were prepared (MOD cavity) and 48 feldspathic ceramic inlays restorations were obtained. Specimens (tooth-restoration) were allocated into three groups considering the bonding strategy (n = 16): 1 - Conventional (groups 1 and 2): one-step total etch adhesive system (dentin treatment), hydrofluoric acid (HF) and silane (S) ceramic surface treatment, cementation with resin cement, 2 - Simplified (groups 3 and 4): RelyX U100 (3M) adhesive resin cement without dentin and ceramic surface treatment; 3 - Simplified modified (groups 5 and 6): RelyX U100 associated with HF + surface treatment. Specimens from groups 1, 3 and were subjected to mechanical cycling (CM) - 2,000,000 pulses, 100N on the cusp, 37ºC. Each specimen was sectioned to produce tooth-restoration-tooth bars specimens (cross-sectional area: 1mm2) that were submitted to microtensile bond strength test. The fractured area of each specimen was analyzed. Stress distribution was analyzed by a virtual model simulating the in vitro study by FEA. Variance analysis showed that: factors effect interaction was not statistically significant (there was no statistically differences between strength bond values with CM from groups 1 and 3). Strategy effect was statistically significant (strategy 3 mean strength bond [5.59 MPa] was significantly higher than the strategy 1strength bond [3.44 MPa]). Predominant failure mode was cement-cohesive-type. Von Mises analysis showed stress concentration at cement near the marginal ridge / Mestre
316

Avaliação da biocompatibilidade e citotoxicidade dos cimentos : Endo-CPM-Sealer, Sealapex e Ângelus MTA /

Watanabe, Simone. January 2008 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Célio Percinoto / Banca: Elisa Maria Aparecida Giro / Resumo: A necessidade de melhorar a qualidade dos materiais utilizados no tratamento endodôntico tem estimulado o estudo de vários materiais, buscando melhores condições de trabalho, biocompatibilidade e propriedade de estimular a ocorrência do selamento biológico. Este trabalho teve a finalidade de avaliar quantitativamente e qualitativamente a resposta tecidual frente ao implante de tubos de polietileno preenchidos pelos cimentos Endo-CPM-Sealer®, Sealapex® e Ângelus MTA® em tecido subcutâneo de ratos e a citotoxicidade e a produção de citocinas (IL-1β e IL-6) por fibroblastos de camundongos estimulados por estes cimentos. Para os testes de biocompatibilidade foram utilizados 30 ratos, os quais receberam individualmente três implantes de tubos de polietileno contendo os cimentos a serem testados e mais um tubo vazio como controle. Após 7, 15, 30, 60 e 90 dias do período de implantação, os animais foram sacrificados e os tubos de polietileno juntamente com o tecido que o circunda foram removidos, fixados e processados para análise em microscopia de luz. Após inclusão em glicol metacrilato, foram realizados cortes seriados de 3mm, corados com hematoxilina-eosina e cortes de 10mm, corados com Von Kossa e sem coloração para serem analisados sob luz polarizada. Os resultados foram analisados estatisticamente pelo teste de Kruskal Wallis. Os materiais Endo-CPM-Sealer®, Sealapex® e Ângelus MTA® causaram reações moderada no tempo experimental de 7 dias que diminuiu com o tempo. A resposta foi similar entre os grupos Controle, Endo- CPM-Sealer® e Ângelus MTA® no tempo experimental de 30 dias. Aos 60 dias todos os grupos foram semelhantes ao Controle. Mineralizações e granulações birrefringentes à luz polarizada foram observadas com todos os materiais. Foi possível concluir que o Endo-CPM-Sealer® foi biocompatível e estimulou a mineralização. Para o teste... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The need of improving the quality of materials used in endodontic treatment has stimulated the study of various materials seeking better working conditions, biocompatibility and property to stimulate the occurrence of biological sealing. The aim of this study was to evaluate quantitatively and qualitatively the tissue response to the implantation of polyethylene tubes filled with Endo-CPM-Sealer®, Sealapex® and Ângelus MTA® in subcutaneous tissue of rats and cytotoxicity and production of cytokines (IL-1β and IL-6) by mouse fibroblasts stimulated by these sealers. Thirty rats were used for the biocompatibility tests. Each animal received three implants of polyethylene tubes containing the cement to be tested and one empty polyethylene tube was used as control. After 7, 15, 30, 60 and 90 days from the implantation time, the animals were killed and the tubes with surrounding tissues were removed, fixed and processed for analysis using a light microscope. After inclusion in glycol methacrylate, they were serially sectioned into 3 μm or 10 μm cuts and stained with hematoxylineosin, Von Kossa or remained without staining to be observed under polarized light. The results were statistically analyzed by Kruskal Wallis test. The materials Endo- CPM-Sealer®, Sealapex® and Ângelus MTA® caused moderate reactions at 7 days which decreased with time. The response was similar among the control group, Endo- CPM-Sealer® and Ângelus MTA® at the 30th day. At 60th day all groups were similar to control group. Mineralization and granulations birefringent to the polarized light were observed with all materials. It was possible to conclude that Endo-CPM-Sealer® was biocompatible and stimulated mineralization. To test the cytotoxicity of mouse fibroblast (L929) were incubated in plate of 24 wells and stimulated with the sealers tested. Cell culture... (Complete abstract click electronic access below) / Mestre
317

Análise microscópica de capeamento pulpar direto com diferentes materiais em dentes humanos / Microscope analyze of direct dental pulp capping with differents materials in human teeth

Patricia de Oliveira Penina 06 November 2007 (has links)
O capeamento pulpar direto busca preservar a vitalidade pulpar. Este trabalho apresenta a resposta tecidual de polpas humanas ao capeamento pulpar direto com o Agregado de Trióxido Mineral (MTA) comparado com o hidróxido de cálcio. Foram utilizados 20 pré-molares de dez pacientes com extração indicada para tratamento ortodôntico. Todos os dentes apresentavam vitalidade pulpar e neles foram feitos capeamentos pulpares diretos com MTA ou com o hidróxido de cálcio. Os dentes foram extraídos num período de 14 dias ou 45 dias, estabelecendo os seguintes grupos experimentais: Ca(OH) 14 dias; Ca(OH) 45 dias; MTA 14 dias e MTA 45 dias. Estes dentes foram analisados microscopicamente por dois examinadores treinados. Os dados obtidos foram tabulados, utilizando-se o teste Kappa para observar o grau de concordância entre os examinadores. Para avaliação comparativa entre as respostas citotóxicas dos materiais testados foi aplicado o teste não paramétrico Kruskal-Wallis e o teste de Dunn para comparações individuais e identificação da significância dos achados. Na análise dos resultados não houve diferença estatisticamente significante entre os grupos nos períodos experimentais de 14 e 45 dias, e nem na resposta inflamatória pulpar frente ao hidróxido de cálcio quando comparado ao MTA. Quanto à espessura e à organização da barreira dentinária reparatória com o hidróxido de cálcio, quando comparado com o MTA também não apresenta diferença estatisticamente significante. Conclui-se que o MTA satisfaz os requisitos de um material capeador pulpar em dentes de humanos, apresentando propriedades físicas e biológicas que o indicam para este tratamento. / The direct dental pulp capping aims to preserve the pulp vitality. This work shows the tissue response from human pulps to that procedure with the Mineral Trioxide Agregate (MTA) compared to calcium hydroxide - Ca(OH)2. Twenty premolars from 10 patients with extraction indicated to orthodontic treatment were used. All teeth showed pulp vitality and were treated with direct dental pulp capping with MTA or with calcium hydroxide. The teeth have been extracted within 14 or 45 days, stablishing the following experimental groups: Ca(OH)2 14 days; Ca(OH)2 45 days; MTA 14 days; and MTA 45 days. These teeth were analyzed under microscopy by two observers trained. The data obtained were put in table using the Kappa test to note the agreement degree between the observers. For the comparative assessment between the citotoxic response from material tested has been applied the non-paired Kruskal-Wallis test, and the Dunns test for individual comparisons and identifying the significance of findings. In the analysis of results there had no statistically significant difference between the groups in experimental periods of 14 days and 45 days, not even in the pulp inflammatory response to calcium hydroxide when compared to MTA. The thickness and arrangement of the healing dentin barrier faced with calcium hydroxide, when compared to MTA, also showed no statistically significant difference. It may be concluded that the MTA fulfils the requirements of pulp capping material in human teeth showing biological and physical properties that indicate it for this treatment.
318

Cimento de silicato de cálcio modificado com nanopartículas de vidro bioativo para aplicação como substituto de dentina /

Corral Núñez, Camila María. January 2017 (has links)
Orientador: Hernane da Silva Barud / Resumo: Os cimentos de silicato de cálcio têm se desenvolvido rapidamente durante as últimas décadas; com a aparição de novos cimentos para uso em odontologia restauradora. Estes cimentos apresentam diferentes composições químicas e por tanto provavelmente diferente radiopacidade. A incorporação de nanopartículas de vidro bioativo poderia melhorar a bioatividade dos cimentos de silicato de cálcio. O objetivo foi avaliar a composição química e radiopacidade dos cimentos a base de silicato de cálcio Biodentine (BD) e TheraCal LC e a contribuição do acréscimo de nanopartículas de vidro bioativo (nVB) no BD. Método: Foram realizados testes de radiopacidade de acordo com norma ISO 9917 e caracterização com microscopia eletrônica de varredura e análise elementar (MEV/EDX) dos novos cimentos de silicato de cálcio BD e TheraCal LC. Posteriormente, nVB foram sintetizadas com técnica sol-gel, e foram preparados nanocompósitos do BD com 1 e 2% em peso de nVB (1%nVB/BD e 2%nVB/BD). A bioatividade dos nanocompósitos foi avaliada in vitro e caracterizado com MEV/EDX, análise de espectroscopia no infravermelho por transformada de Fourier e difração de raios-X (DRX). Também os nanocompósitos foram aplicados em discos de dentina e a interface caracterizada com MEV-EDX. Resultados: BD apresentou zircônio como elemento radiopacificante e maiores valores de radiopacidade do que o TheraCal LC, que apresentou bário, estrôncio e zircônio como radiopacificadores. A incorporação de nVBs em BD melhorou a bioa... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
319

Avaliação "in vitro" da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário /

Orbegoso Flores, Victor Humberto. January 2001 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Marcos Ribeiro Moysés / Banca: Alberto Magno Gonçalves / Banca: Sillas Luiz Lordelo Duarte Júnior / Banca: Sizenando de Toledo Porto Neto / Resumo: O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with "silver nitrate" for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below). / Doutor
320

Avaliação histopatológica do reparo apical e periapical em dentes de cães com vitalidade pulpar, após tratamento de canais radiculares utilizando dois cimentos obturadores à base de resina epóxica. Análise do pH e concentração de cálcio total /

Rasquin, Luis Cardoso. January 2001 (has links)
Resumo: O objetivo do presente estudo foi o de avaliar comparativamente, dois cimentos obturadores de canal radicular à base de resina epóxica, AH Plus e Sealer Plus, através de duas diferentes metodologias. 1. Teste in vivo - Avaliação histopatológica em dentes de cães. Foram utilizados 36 canais radiculares de dentes pré-molares superiores e inferiores de 2 cães, com vitalidade pulpar, os quais, após o preparo biomecânico coadjuvado pela irrigação/aspiração e inundação com solução de hipoclorito de sódio a 1% (Líquido de Dakin), foram obturados pela técnica clássica complementada pela condensação lateral ativa, empregando os cimentos Sealer Plus (Grupo I) e AH Plus (Grupo II). Decorridos 90 dias após a obturação, os animais foram sacrificados por sobredose anestésica, as maxilas e mandíbulas removidas e fixadas em formol a 10%, durante 48 horas. Após processamento histológico de rotina, os cortes foram corados pela hematoxilina e eosina, pelo tricrômico de Mallory e Brown e Brenn. A análise histopatológica evidenciou que o cimento AH Plus, quanto à compatibilidade biológica, mostrou-se superior ao Sealer Plus, sendo o cimento que melhor permitiu a deposição de tecido mineralizado à nível apical, oferecendo um selamento quase completo na maioria dos casos, com infiltrado inflamatório ausente e quando presente era suave no tecido intersticial e/ou junto ao material obturador, assim como na região periapical. Já, com o cimento Sealer Plus, ocorreu predominantemente, selamento parcial, porém sempre acompanhado de infiltrado inflamatório de grau suave, no tecido intersticial, porém, mais concentrado, junto ao cimento obturador. Quando o material obturador era observado na região periapical, o infiltrado inflamatório apresentava-se, classificado como de grau moderado, concentrado próximo ao... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The scope of the present study was to evaluate comparativily, two root canal resin - based sealers - AH Plus and Sealer Plus through two different methodologies. 1. In vivo study - Histopathological evaluation in teeth of dogs. 36 root canals of lower and upper bicuspide teeth of 2 dogs with vital pulp, which after biomechanic preparation utilizing sodium hypochloride solution at 1% (Milton solution) were filling by classical technique complemented by active lateral condensation, using Sealer Plus (Group I) and AH Plus (Group II). 90 days after treatment, the animals were sacrificed by overdose anesthetical. After histopathological processing of routine, the sections were stained with hematoxiline and eosine, Mallory Trichromic and Brown and Brenn. The histopathological analysis had evidenced that the AH Plus sealer shows more biological compatibility in relation to the Sealer Plus being the sealer that shows more good deposition of mineralized tissue to the apical level, offering an almost full apical sealing in the majority of the cases, with infiltrated inflammatory absent and when present was mild in the interstitial tissue and/or together to the material sealer, as well as in the periapical region. With the Sealer Plus, partial apical sealing occurred, however always followed by infiltrated inflammatory of mild degree in the intersticial tissue, however, more concentrated, together to the filling material when in the periapical region, the inflammatory infiltrated was presented, classified as of moderate degree. 2. In vitro study - With the objective to analyze pH and clearing of total calcium by periods that had varied from 0 to the 5 days, the filling materials. AH Plus and Sealer Plus had been manipulated according to the manufacturers instructions. Samples of each sealer were... (Complete abstract, click electronic address below). / Orientador: Mario Roberto Leonardo / Coorientador: Léa Assed B. da Silva / Banca: Idomeo Bonetti Filho / Banca: Francisco José de Souza Filho / Banca: Jesus Djalma Pécora / Doutor

Page generated in 0.366 seconds