• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 6
  • 5
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 46
  • 46
  • 20
  • 10
  • 9
  • 9
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigation of fundamental processes affecting the behaviour of electric arcs in electromagnetic interrupters

Ennis, Michael Gerard January 1996 (has links)
No description available.
2

SF←6 decomposition under power arc and its degradation effects on superficial properties of insulating materials

Garcia, Roberto Linan January 1993 (has links)
No description available.
3

Predictive Maintenance of Circuit Breakers

Leung , Tat Wai (Alan) January 2007 (has links)
For predictive maintenance of circuit breakers, a number of variables must be considered in order to assess the genuine working condition of a circuit breaker [CB]. This thesis selects vibration signatures obtained on the operating mechanisms and arcing chambers as a source of monitoring breaker conditions. The task of analyzing the behavior of a circuit breaker is perennial and difficult but the thesis has an attempt to tackle this problem. Experiments have been devised to monitor CBs; however, these have limitations details of which will be discussed. For example, each circuit breaker has its own unique vibration signature and the shape of the vibration may be different even though breakers confront similar problems. CBs have decades-long service life spans and failure rates are relatively low. Those that fail are not necessarily saved and there have been relatively few samples to base evidence upon. There are different vibration analysis algorithms available including Dynamic Time Warping [DTW], Resolution Ratio [RR], Discrete Envelope Statistics [DES], event time extraction, Chi-square based shape methods, and fractal theory. Some of these algorithms are based on acoustic properties of materials and rely on assessing extracted time component and the frequency components are extracted. This research applies multi-resolution analysis [MRA] to decomposed signals to in order to assess different sub-wave levels so that wave features may be captured and modeled. There are many ways to analyze the waves. This thesis uses optimizing fuzzy rules with genetic algorithm [GA] as the proposed method. The simuation part of the thesis uses spring performance as an example of how vibration signature analysis may be implemented. Spring vibrations are evaluated by two classification algorithms: Dynamic Time Warping [DTW] and multi-resolution analysis [MRA] with optimizing fuzzy rules with genetic algorithm [GA]. The first method is competent to identify the faulty cases from the normal ones by looking at the deviation of the vibration signature frequency content. In contrast, it is not capable to identify the degree of how bad it performs from looking at the frequency variation. For the second method, it is capable of not only classifying the abnormal cases from the normal cases, but also distinguishing the vibration signatures into different category so that the spring condition can be retrieved immediately. Fuzzy rules is capable of classify a new case to a category and genetic algorithm is an effective tool to minimize the applicable fuzzy rules. The accuracy of the identification is very satisfactory, which is over 90%. Consequently, the proposed algorithm is very useful for asset management purpose of breaker since the lifespan of the spring is known. Diagnostic technicians are able to make decision on the replacement scheme of the spring. There are some areas that this research uncovered that suggests further study is mandated. For example, there are other parameters that can be monitored and compared other than spring constant such as valve position in trip coil and close coil, acceleration parameter in changeover valves, damping in hydraulic cylinders and mechanical linkages, gas pressure in primary contacts and breaker resistance in line system.
4

Investigation of electric arcs in self-generated flow

Yan, Jiu Dun January 1997 (has links)
No description available.
5

Overload protection using solid state devices

Means, James Andrew, 1937- January 1966 (has links)
No description available.
6

A solid state AC circuit breaker with a selective trip time

Carter, David William, January 1969 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1969. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
7

Spectroscopic investigation of current zero arc properties

El-Kholy, S. M. January 1988 (has links)
No description available.
8

Effects of high frequency arcing in SF←6 puffer interrupters from low inductive current switching

Chaaraoui, Jamal Abdullatif January 1993 (has links)
No description available.
9

Ground fault detection for human safety utilizing a differential transformer sensor

Williams, Lynn Edward, January 1968 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1969. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
10

High voltage direct current interruption

Rashid, Parvez. January 1979 (has links)
Thesis (M.S.)--University of Wisconsin--Madison. / Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 125-127).

Page generated in 0.0702 seconds