• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 316
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 325
  • 189
  • 97
  • 58
  • 58
  • 45
  • 39
  • 38
  • 37
  • 37
  • 29
  • 27
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Tratamento por coagulação-floculação de lixiviado bruto de aterro sanitário com e sem pré-tratamento biológico em reator sequencial em batelada

Gewehr, André Granzotto January 2012 (has links)
A forma de tratamento e destinação final ainda mundialmente preponderante para os resíduos sólidos urbanos é o aterro sanitário, método que gera, além de uma massa sólida residual, parcialmente estabilizada, subprodutos finais líquidos e gasosos. O efluente líquido, conhecido como lixiviado, necessita tratamento específico, devido a sua elevada nocividade ao meio ambiente, em função, principalmente, de suas elevadas concentrações de nitrogênio amoniacal e de matéria orgânica, em elevado percentual, recalcitrante. O presente trabalho avaliou em escala de bancada o tratamento, via processo físico-químico, através de coagulação-floculação, de lixiviado bruto proveniente de aterro sanitário Central de Resíduos do Recreio (operado pela Companhia Riograndense de Valorização de Resíduos), desprovido de qualquer tratamento prévio, e de lixiviado pré-tratado biologicamente em reatores sequenciais em batelada (RSB). Para o processo de coagulação-floculação foram testados os coagulantes policloreto de alumínio (PAC), cloreto férrico, sulfato férrico e tanino. Sucessivas etapas foram planejadas para a determinação de dosagem e ajuste de pH ótimos, para cada coagulante empregado, e para a verificação da influência de tempos e gradientes de misturas, bem como foi testada a aplicação de polímeros auxiliares de floculação. As variáveis resposta utilizadas para o monitoramento e a avaliação de eficiências foram a cor verdadeira, turbidez (com e sem prévia filtração), DQO, volume de lodo gerado e pH. O uso de reator sequencial em batelada objetivou nitrificação/desnitrificação convencional das elevadas concentrações de nitrogênio amoniacal e eventual oxidação de matéria carbonácea. Verificou-se que os diferentes tempos e gradientes de mistura testados, assim como a utilização de polímeros auxiliares, não produziram impactos nos resultados. Os coagulantes inorgânicos apresentaram elevadas eficiências de remoção, com destaque para o cloreto férrico, o qual na dosagem de 1102 mgFe+3/L e ajuste inicial de pH em 6,2 removeu 98% da cor verdadeira e da turbidez filtrada, 63% da DQO, 40% da DBO5, e 88% de turbidez não filtrada do lixiviado bruto. Apesar da recalcitrância de considerável fração da matéria orgânica do lixiviado, o RSB2 removeu 40% da DQO e 60% da DBO5 originais. A coagulação-floculação do efluente do RSB2 necessitou inferiores dosagens dos coagulantes em relação ao processo com lixiviado bruto. O cloreto férrico, em dosagem ótima de 826 mgFe+3/L e ajuste de pH em 6,3, removeu 95% da cor, 77% da DQO, 82% da DBO5, 94% da turbidez filtrada e 92% da turbidez não filtrada. Concluiu-se por elevada viabilidade técnica do processo de coagulação-floculação para o lixiviado com e sem pré-tratamento, a partir da otimização das condições de contorno do processo. O pré-tratamento em RSB, quando utilizado controle de pH, demonstrou grande potencial para nitrificação/desnitrificação e oxidação de significante parcela da matéria carbonácea do lixiviado bruto. / The form of treatment and disposal still prevalent worldwide for solid waste is the landfill, a method that generates, in addition to a solid mass residual partially stabilized, liquid and gas end products. The effluent liquid, known as leachate, requires specific treatment, due to its high harmfulness to the environment, due mainly to its high concentrations of ammonia nitrogen and organic matter in high percentage, recalcitrant. This study evaluated the treatment on bench scale, via physico-chemical process, by coagulation-flocculation, of raw leachate from Central de Resíduos do Recreio landfill (operated by Companhia Riograndense de Valorização de Resíduos), devoid of any previous treatment, and biologically pretreated leachate reactors in sequential batch reactors (SBR). For the process of flocculation-coagulation were tested polyaluminum chloride (PAC), ferric chloride, ferric sulfate and tannin. Successive stages were designed for determining dosage and optimum pH adjustment for each coagulant employed and for verifying the influence of times and gradients mixtures, as well as tested in the application of polymers flocculation auxiliaries. The answers used for parametric monitoring and evaluation of efficiencies were the true color, turbidity (with and without prior filtration), COD, sludge volume and pH. The use of sequential batch reactor aimed conventional nitrification/denitrification of the high concentrations of ammonia nitrogen and eventual oxidation of carbonaceous matter. It was found that the different gradients and mixing times tested, as well as the use of auxiliary polymers, did not produce impact on the results. The inorganic coagulants showed high removal efficiencies, especially ferric chloride, which at a dose of 1102 mgFe+3/L and initial pH adjusted to 6.2, removed 98% of the true color and filtered turbidity, 63% of COD, 40% of BOD5 and 88% of unfiltered turbidity. Despite the considerable fraction of the recalcitrance of organic matter in the leachate, the SBR2 removed 40% of COD and 60% of BOD5 of the original. The coagulation-flocculation of the effluent from SBR2 required lower dosages of coagulants in relation to the similar process with raw leachate. Ferric chloride in optimum dosage of 826 mgFe+3/L and adjusting pH to 6.3, removed 95% of color, 77% of COD, 82% of BOD5, 94% of the filtered turbidity and 92% of unfiltered turbidity. It was concluded by high technical feasibility of the process of flocculation-coagulation for the leachate with and without pre-treatment, based on the optimization of the boundary conditions of the process. The pre-treatment with SBR, when pH control, demonstrated high potential for nitrification/denitrification and oxidation of a significant portion of the carbonaceous of the raw leachate.
272

Otimização do tratamento de efluente lácteo sintético com o uso de coagulantes alternativos / Optimization of the treatment of synthetic dairy effluent with the use of alternative coagulants

Muniz, Gustavo Lopes 21 February 2018 (has links)
Submitted by MARCOS LEANDRO TEIXEIRA DE OLIVEIRA (marcosteixeira@ufv.br) on 2018-08-01T20:14:46Z No. of bitstreams: 1 texto completo.pdf: 3556093 bytes, checksum: 27a4adab796975b555ffecbaf82dffd7 (MD5) / Made available in DSpace on 2018-08-01T20:14:46Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3556093 bytes, checksum: 27a4adab796975b555ffecbaf82dffd7 (MD5) Previous issue date: 2018-02-21 / Os laticínios geram, diariamente, elevados volumes de águas residuárias que são originadas das limpezas das instalações e da fabricação de produtos. Estas águas caracterizam-se por apresentar concentrações elevadas de nutrientes, gorduras, sólidos suspensos e dissolvidos, demanda bioquímica (DBO) e química de oxigênio (DQO) e pH que varia em função do que é produzido e dos produtos utilizados na higienização deste tipo de empreendimento. Dentre os métodos disponíveis para tratamento dos efluentes lácteos, destaca-se o Tratamento Primário Quimicamente Assistido (TPQA), conhecido também como CEPT (Chemically Enhanced Primary Treatment). No TPQA coagulantes químicos são adicionados na etapa do tratamento primário a fim de aprimorar a remoção de poluentes. Entretanto, a aplicação de coagulantes químicos tem gerado um inconveniente às indústrias e estações de tratamento que utilizam este método, que é a produção de grandes volumes de lodo com características tóxicas e não biodegradável. Alguns resíduos agroindustriais, como o quiabo (Abelmoschus esculentus), sementes de maracujá (Passiflora edulis), resíduos da carcinocultura e as cascas da mutambeira (Guazuma ulmifolia) apresentam elevado potencial para serem utilizados como coagulantes alternativos no tratamento de efluentes, devido às suas características químicas. O emprego de coagulantes no tratamento de efluentes envolve a otimização da dose de coagulante e do pH, uma vez que influenciam, diretamente, na eficiência de remoção de poluentes. Para isso, métodos de superfície de resposta (MSR) vêm sendo utilizados na otimização dessas variáveis. Assim, o objetivo deste estudo foi avaliar a eficiência de coagulantes naturais no tratamento de efluente lácteo sintético (ELS) via flotação por ar dissolvido (FAD), otimizando as condições operacionais de dose de coagulante e pH na remoção da turbidez, DQO e compostos orgânicos que absorvem na região do ultravioleta no comprimento de onda 254 nm (compostos UV 254 ) e comparar planejamentos estatísticos na descrição dos resultados. Em primeiro momento comparou-se dois planejamentos experimentais, a matriz de Doehlert e o delineamento composto central rotacional (DCCR) na descrição de remoção de poluentes do ELS, utilizando dois coagulantes orgânicos, o Tanfloc e a poliacrilamida (PAM). Observou-se nos resultados obtidos que ambos os planejamentos geraram modelos matemáticos significativos (p ≤ 0,05) e com elevada capacidade de predição. Além disso, foi verificado que o ponto ótimo obtido para remoção de poluentes foi próximo entre os planejamentos, observando, porém, pequena diferença entre as dosagens de coagulantes. Em segundo momento foi avaliado a eficiência dos coagulantes obtidos do extrato do quiabo, das sementes de maracujá, a quitosana e as cascas da mutambeira na remoção da turbidez, DQO e compostos UV 254 do ELS, otimizando as condições de dose de coagulante e de pH através do DCCR para os dois primeiros e da matriz de Doehlert para os demais. Foi observado que os coagulantes estudados são eficientes na remoção de poluentes do ELS, sendo a eficiência diretamente relacionada ao pH e à dose de coagulante aplicada. Os pontos ótimos de remoção de poluentes encontrados foram: 2,0 g L -1 de extrato de quiabo em pH 9,00; com eficiência de remoção de turbidez e DQO de 91,1 e 48,3%, respectivamente; 1,3 g L -1 de extrato de semente de maracujá em pH 5,00; com eficiência de remoção de turbidez e DQO de 91,5 e 50,3%, respectivamente; dose de quitosana igual a 73,34 mg L -1 em pH 5,00; com eficiência de remoção da turbidez, DQO, e compostos UV 254 de 97,6; 77,5 e 88,8%, respectivamente e 775,8 mg L -1 de cascas de mutambeira em pH 5,00; com eficiência de remoção de turbidez, DQO e compostos UV 254 de 95,8; 76,0 e 85,6%, respectivamente. Assim, quando aplicados na condição ideal, os coagulantes testados apresentam potencial para substituir os coagulantes químicos atualmente comercializados, minimizando, assim, o passivo ambiental. / Dairies, daily, generate high volumes of wastewater from cleaning site and manufacturing products. These waters have high concentrations of nutrients, fats, suspended and dissolved solids, biochemical oxygen demand (BOD) and chemical oxygen demand (COD) and pH that varies according to what is produced and the products used in the sanitation of this type of enterprise. Among the available methods for the treatment of dairy effluents, stands out the Chemically Enhanced Primary Treatment (CEPT). In CEPT, chemical coagulants are added in the primary treatment step in order to improve the removal of pollutants. However, the application of chemical coagulants generates high volumes of toxic and not biodegradable sludge. Some agroindustrial residues, such as okra (Abelmoschus esculentus), passion fruit seeds (Passiflora edulis), shrimp waste and bark of Guazuma ulmifolia have potential to be used as alternative coagulants in the treatment of effluents, due to their chemical characteristics. The use of coagulants in the treatment of effluents involves the optimization of the coagulant dosage and pH, once they directly influence in the efficiency of pollutants removal. For this, surface response methodology (SRM) have been used in the optimization of these variables. Thus, the objective of this study was to evaluate the efficiency of natural coagulants in the treatment of synthetic dairy effluent (SDE) by dissolved air flotation (DAF), optimizing the operational conditions of coagulant dose and pH in the removal of turbidity, as well as COD and organic compounds that absorb in the ultraviolet region at a wavelength of 254 nm (UV 254 compounds) and compare statistical design in the description of results. At first, two experimental designs were compared, the matrix of Doehlert and Central Composite Rotational Design (CCRD), in the description of pollutants removal of SDE using two organic coagulants, Tanfloc and polyacrylamide. It was observed in the obtained results that the both plans generated significant mathematical models (p ≤ 0,05) and with high predictive capacity. Furthermore, it was verified that the optimum point obtained for the removal of pollutants was close between the designs, noting, however, a small difference between the coagulant dosages. Secondly, was evaluate the efficiency of the coagulants obtained from the okra extract, passion fruit seeds, chitosan and bark of Guazuma ulmifolia in the removal of turbidity, COD and UV 254 compounds of SDE. The coagulant dosage and pH conditions were optimized through the CCDR for the first two extracts and the Doehlert matrix for the others. It was observed that the coagulants studied are efficient in the removal of SDE pollutants, once the efficiency is directly related to the pH and the coagulant dosage applied. The optimal points of removal of pollutants were: 2,0 g L -1 extract of okra in pH 9,00; with removal efficiency of turbidity and COD of 91,1 and 48,3%, respectively; 1,3 g L -1 passion fruit seeds extract in pH 5,00; with removal efficiency of turbidity and COD of 91,5 e 50,3%, respectively; 73,34 mg L -1 dose of chitosan in pH 5,00; with removal efficiency of turbidity, COD and UV 254 compounds of 97,6; 77,5 e 88,8%, respectively and 775,8 mg L -1 of Guazuma ulmifolia bark in pH 5,00; with removal efficiency of turbidity, COD and UV 254 compounds of 95,8; 76,0 e 85,6%, respectively. Thus, when applied in the optimum condition, the coagulants tested have potential to replace the currently marketed chemical coagulants, minimizing, this way, environmental liability.
273

Tratamento via reação de fenton de efluente cosmético da linha de produção de filtro solar / Treatment via fenton reaction of cosmetic waste water filter production line solar

Morais, Weberson de Oliveira 30 September 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-31T12:54:54Z No. of bitstreams: 2 Dissertação - Weberson de Oliveira Morais - 2015.pdf: 1625123 bytes, checksum: f4f86c2fdb7e73438d0f4555a6827285 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-31T12:56:10Z (GMT) No. of bitstreams: 2 Dissertação - Weberson de Oliveira Morais - 2015.pdf: 1625123 bytes, checksum: f4f86c2fdb7e73438d0f4555a6827285 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-05-31T12:56:10Z (GMT). No. of bitstreams: 2 Dissertação - Weberson de Oliveira Morais - 2015.pdf: 1625123 bytes, checksum: f4f86c2fdb7e73438d0f4555a6827285 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-09-30 / Advanced oxidation processes are consolidated technologies when it comes to treatment of industrial wastewater. Such processes are based on the generation of the hydroxyl radical (• HO), with high potential to oxidize organic matter (2,8eV). These, because they are poorly selective and highly reactive, oxidize the organic matter from promoting an increase in the biodegradable fraction to a possible complete mineralization of the contaminant in the wastewater. Among the advanced oxidation processes, the Fenton’s reagent stands out for its simplicity, low treatment time and low economic value. This reaction proceeds by catalytic decomposition of hydrogen peroxide (H2O2), in acid pH, by oxidizing Fe+2 to Fe+3 with the subsequent generation of the hydroxyl radical. In the Fenton’s reaction, some intermediate reactions give a unique characteristic to the process during the treatment which stand out hydrolysis of Fe+2 and Fe+3 forming a series of aqueous ferrous and ferric complexes which enable the occurrence of Process coagulation / flocculation with subsequent formation of sludge. The integration of these two technologies confers the treated wastewater a significant increase in contaminant removal, because, from this stage, the process of sedimentation, there is the drag of a large amount of non-degraded organic matter via chemical oxidation, in the form of sludge. In this work the application of integrated Fenton’s reaction to coagulation / flocculation in the treatment of cosmetic wastewater sunscreen lotion production line. The treatment was performed at Jar Test equipment with one liter volume: carried out rapid mixing at 300 rpm for 20 seconds after the addition of ferrous sulfate heptahydrate, subsequently slow mixing at 30 rpm for 6 minutes and 10 seconds after the addition of hydrogen peroxide. After this sequence, each test was allowed to rest on sedimentation for 60 minutes. The entire process took place at ambient temperature. At first the treatment was executed in a simulated wastewater from a sunscreen acquired in a cosmetics industry in the metropolitan area of Goiânia. After optimization of the concentration of 22,12 mgL-1 Fe+2, 500 mgL-1 H2O2 and pH 4.0, we observed a reduction of 82.56% in the chemical oxygen demand (COD) , 97.33% and 98.00% in turbidity in absorbance which indicated a high efficiency of the treatment in regard to an adjustment to CONAMA Resolution 430 2011. Other parameters were analyzed in order to obtain reliable information about the proposed treatment, and a reduction of 91.49% of Total Organic Carbon (TOC), 99.67% of oils and greases, 98.81% of total suspended solids (TSS), 73.05% of surfactants and 64.68 % of total phenols. The total treatment time was 226 minutes and 30 seconds. With these removal treatment with the actual wastewater was considered extremely efficient for a possible application of this methodology in the industrial segment, it should be observed that when applied in an isolated way, the advanced oxidation processes do not have good efficiency, however, in this study the treatment means Fenton’s reaction integrated technology coagulation / flocculation has a high capacity for a full-scale application in the cosmetic segment. / Os processos oxidativos avançados são tecnologias consolidadas em se tratando de tratamento de efluentes industriais. Tais processos são baseados na geração do radical hidroxila (•OH) que possui elevado potencial de oxidar a matéria orgânica (2,8eV). Estes, por serem pouco seletivos e altamente reativos, oxidam a matéria orgânica promovendo desde um aumento na fração biodegradável até uma possível mineralização total do contaminante presente no efluente. Dentre os processos oxidativos avançados, o reagente de Fenton se destaca pela sua simplicidade, baixo tempo de tratamento e baixo valor econômico. Esta reação se processa pela decomposição catalítica do peróxido de hidrogênio (H2O2), em meio ácido, através da oxidação de Fe+2 a Fe+3 com a posterior geração do radical hidroxila. Durante a reação de Fenton, algumas reações intermediárias dão ao processo uma particularidade ímpar durante o tratamento, das quais, se destacam a hidrólise dos íons Fe+2 e Fe+3 formando uma série de complexos aquo-ferrosos e férricos que possibilitam a ocorrência do processo de coagulação/floculação com a posterior formação de lodo. A integração destas duas tecnologias confere ao efluente tratado um aumento significativo na remoção de contaminantes, pois, a partir desta etapa, com o processo de sedimentação, ocorre o arraste de grande quantidade da matéria orgânica não degradada via oxidação química, na forma de lodo. Neste trabalho foi estudada a aplicação da reação de Fenton integrada à coagulação/floculação no tratamento de efluente cosmético da linha de produção de filtro solar. O tratamento foi realizado no equipamento JAR TEST com volume de um litro: Realizou-se a mistura rápida a 300 rpm por 20 segundos, logo após a adição de sulfato ferroso hepta-hidratado, posteriormente a mistura lenta, a 30 rpm por 6 minutos e 10 segundos com a adição de peróxido de hidrogênio. Após esta sequência, cada teste ficou em repouso para sedimentação por 60 minutos. Todo processo ocorreu em temperatura ambiente. Em um primeiro momento o tratamento foi realizado em um efluente simulado a partir de um filtro solar adquirido em uma indústria cosmética da região metropolitana de Goiânia. Após a otimização da concentração de 22,12 mgL-1 de Fe+2, 500 mgL-1 H2O2 e valor de pH 4,0, foi possível observar uma redução de 82,56% na Demanda Química de Oxigênio (DQO), 97,33% na turbidez e 98,00% na absorvância o que indicou uma elevada eficiência do tratamento no que diz respeito a uma adequação à resolução CONAMA 430 de 2011. Outros parâmetros foram analisados a fim de obter informações mais seguras a cerca do tratamento proposto, e com redução de 91,49% de Carbono Orgânico Total (COT), 99,67% de óleos de graxas, 98,81% de sólidos suspensos totais (SST), 73,05% de surfactantes e 64,68% de fenóis totais, a reação de Fenton foi considerada um processo de elevada eficiência no tratamento de efluente da linha de produção de filtro solar. Após a aplicação deste tratamento em efluente simulado, o próximo passo foi à aplicação da metodologia ao efluente cosmético real da linha de produção de filtro solar. Com o processo de otimização, a concentração “ótima” de Fe+2 e H2O2 foi de 110 mgL-1 e 700 mgL-1, respectivamente e um valor de pH 4,5. Nestas condições, as mesmas análises do efluente simulado foram realizadas e os valores de remoção foram 90,75% de Demanda Química de Oxigênio (DQO), 99,61% de turbidez, 98,24% de absorvância, 96,24% de Carbono Orgânico Total (COT), 99,26% de óleos e graxas, 97,36% de sólidos suspensos totais (SST), 73,12% de surfactantes e 81,85% de fenóis totais. O tempo total de tratamento foi de 226 minutos e 30 segundos. Com estas remoções o tratamento com o efluente real foi considerado de extrema eficiência para uma possível aplicação da metodologia no segmento industrial, cabe salientar que quando aplicados de maneira isolada, os processos oxidativos avançados não apresentam boa eficiência, no entanto, neste trabalho o tratamento via reação de Fenton integrado à tecnologia coagulação/floculação apresentou elevada capacidade para uma aplicação em escala real no segmento cosmético.
274

Desenvolvimento e aplicação de biocoagulante magnético Fe3O4-MO para remoção do corante reativo preto 5 em meio aquoso sintético e efluente real têxtil / Development and application of Fe3O4-MO magnetic biocoagulant for removal of reactive dye black 5 in synthetic aqueous mean and real textile effluent

Miyashiro, Carolina Sayury 11 December 2017 (has links)
Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2018-04-25T20:20:41Z No. of bitstreams: 1 Carolina_Miyashiro_2017 .pdf: 1779339 bytes, checksum: f6b6d1ffc4073370161792334748de1b (MD5) / Made available in DSpace on 2018-04-25T20:20:41Z (GMT). No. of bitstreams: 1 Carolina_Miyashiro_2017 .pdf: 1779339 bytes, checksum: f6b6d1ffc4073370161792334748de1b (MD5) Previous issue date: 2017-12-11 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / A magnetic biocoagulant (Fe3O4-MO) was produced by the association of nanoparticles of iron oxide (Fe3O4) and Moringa Oleífera Lam (MO) extract in different concentrations (0.5%, 1% and 2%), aiming to evaluate its performance in removal of the reactive dye black 5 (RP5) in aqueous medium (synthetic waste water) and real textile effluent. The MO protein was extracted with saline solution and the nanoparticles were synthesized by the coprecipitation method. The biocoagulant was characterized by X-ray diffractometry (XRD), vibration magnetometry, Fourier Infrared Transformer (FTIR) spectroscopy, scanning electron microscopy with X-ray energy dispersion spectroscopy (SEM / EDS) and transmission electron microscopy (MET). For the coagulation / flocculation / sedimentation process (C/F/S), the operational parameters studied were sedimentation time, biocoagulant concentration and pH. The efficiency of the C/F/S process was determined by the analysis of the apparent color, absorbance, zeta potential and total organic carbon (TOC). After determining the best conditions (concentration of 0.5% MO, dosage of 100 mg L-1 and pH 7) of the C/F/S process, sedimentation kinetic studies for synthetic wastewater (ARS), real effluent (ERT), both with and without magnetic field and the sludge recovered and regenerated with the saline extract of MO (with magnetic field). At the 100 mgL-1 dosage of magnetic biocoagulant at a concentration of 0.5% MO saline, 89% apparent color removals were obtained in the time of 20 min. The C / F / S process shows dependence on the pH of the reaction medium, because at pH 7 color removal values of 83% and 84% were obtained in reaction time 20 and 40 min, respectively. / Um biocoagulante (Fe3O4-MO) magnético foi produzido pela associação de nanopartículas de óxido ferro (Fe3O4) e extrato de Moringa Oleífera Lam (MO) em diferentes concentrações (0,5%, 1% e 2%), para avaliar sua performance na remoção do corante reativo preto 5 (RP5) em meio aquoso (água residuária sintética) e efluente real têxtil. A proteína da MO foi extraída com solução salina e as nanopartículas foram sintetizadas pelo método de coprecipitação. O biocoagulante foi caracterizado por difratometria de raio-X (DRX), magnetometria vibratória, spectroscopia por transformada de Fourier (FTIR), microscopia eletrônica de varredura com espectroscopia por dispersão de energia de Raios-X (MEV/EDS) e microscopia eletrônica de transmissão (MET). Para o processo de coagulação/floculação/sedimentação (C/F/S) os parâmetros operacionais estudados foram tempo de sedimentação, concentração do biocoagulante e pH. A eficiência do processo C/F/S foi determinada pela análise da cor aparente, absorbância, potencial zeta e carbono orgânico total (COT). Após determinar as melhores condições (concentração de MO 0,5%, dosagem de biocoagulante 100 mg L-1 e pH 7) do processo C/F/S, foram realizados estudos cinéticos de sedimentação para água residuária sintética (ARS), efluente real têxtil (ERT), ambos com e sem campo magnético e o lodo recuperado e regenerado com o extrato salino de MO (com campo magnético). Na dosagem 100 mgL-1 de biocoagulante magnético em concentração de 0,5% de solução salina de MO foram obtidos remoções de cor aparente 82% no tempo de 20 min. O processo C/F/S apresenta dependencia em relação ao pH do meio reacional, pois em pH 7 foram obtidos valores de remoção de cor de 83 % e 84 % em tempo de sedimentação 20 e 40 min., respectivamente. Demonstrando-se um materialpromissor na remoção de RP5 e no tratamento de ERT pois possui alta eficiência, preparo simples e condizentes com questões ambientais.
275

Avaliação do desempenho de flotação por ar dissolvido no tratamento de efluente de refinaria de óleo de soja / Valuation of performance of dissolved air flotation on treatment of wastewaters of soybean oil refining

Cecchet, Juliana 06 July 2007 (has links)
Made available in DSpace on 2017-07-10T19:24:01Z (GMT). No. of bitstreams: 1 Juliana Cecchet.pdf: 2090330 bytes, checksum: 58b3febaf50310456ede4d0b8648a7f0 (MD5) Previous issue date: 2007-07-06 / The aim of this work was to value the performance of three types of coagulants, two of them of polichlorate of alum class and one of them was organic, combined to three polyelectrolytes class (anionic, cationic and no ionic) applying the dissolved air flotation (DAF), to viability their use on treatment of effluents of soybean oil refinery. The study was conducted on laboratory scale where first was tested the coagulants on several dosages combined to several bands of pH and three ascension velocities (Va), finding a optimum band of this combination for one of each three batteries. For this, was fixed parameters how time and fast mixed gradient (1 min / 150 s-1), time and slow mixed gradient (10 min / 40 s-1 5 min / 20 s-1), pressure on saturation chamber (450 kPa) and recirculation ratio (30%). Finding the optimum concentration of coagulant (Cc ótima), optimum coagulation pH (pHcoag ótimo) and optimum ascension velocities (Vaótima), fix those parameters and then goes for a variation of polyelectrolyte, testing several dosages and finding a optimum concentrate of polyelectrolyte (Cf ótimo). Finally, with junction of all optimized parameters, was varied de recirculation rate (R) (10, 20 e 30%), choosing the best R and collecting samples for the determination of levels of turbidity, total suspended solids (TSS), volatile suspended solids (VSS), oil and greases (O&G) and chemical oxygen demand (COD) remaining on treated effluent presenting a percentage of remotion COD of 95,4%, 93,7% and 95,1% and O&G of 100%, 94,2% e 99,8% for the batteries 1, 2 e 3 respectively. Despite of being excellent efficiencies of remotion, the treated effluent was not present characteristics for the reuse on the cooling water towers, because its organics load on the raw effluent its too much higher and even with so good levels of remotion, still was necessary a pos treatment to think on reuse. / Este trabalho foi desenvolvido com o objetivo de avaliar o desempenho de três tipos de coagulantes, dois da classe dos PACs (cloreto de polialumínio) e um orgânico, combinados a três classes de polieletrólitos (aniônico, catiônico e não iônico), aplicando o uso de Flotação por Ar Dissolvido (FAD), para viabilizar seu uso em tratamento de efluentes de refinaria de óleo de soja. O experimento foi conduzido em escala de laboratório e primeiramente foram testados os coagulantes em diversas dosagens combinados a diversas faixas de pH e três velocidades ascensionais (Va), encontrando uma faixa ótima dessa combinação para cada uma das três baterias. Para tanto foram fixados parâmetros como tempo e gradiente de mistura rápida (1 min / 150 s-1) tempo e gradiente de mistura lenta (10 min / 40 s-1 5 min / 20 s-1), pressão na câmara de saturação (450 kPa) e razão de recirculação (30%). Encontrando-se a concentração de coagulante ótima (Cc ótima), pH de coagulação ótimo (pHcoag ótimo) e velocidade ascensional ótima (Vaótima). Fixados esses parâmetros foi verificada a variação do polieletrólito, testando-se em diversas dosagens e encontrando uma concentração de floculante ótima (Cf ótimo). Finalmente, com a junção de todos os parâmetros otimizados, efetua-se a variação da razão de recirculação (R) (10, 20 e 30%), escolhendo a melhor R e coletando-se amostras para a determinação dos níveis de turbidez, sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV), óleos e graxas (O&G) e demanda química de oxigênio (DQO) remanescentes no efluente tratado apresentando um grau de remoção de DQO de 95,4%, 93,7% e 95,1% e de O&G de 100%, 94,2% e 99,8% para as baterias 1, 2 e 3 respectivamente. Apesar de serem eficiências excelentes de remoção, o efluente tratado não apresentou características de reuso em torres de resfriamento, pois sua carga orgânica no efluente bruto é muito alta e mesmo com níveis tão bons de remoção ainda seria necessário um pós-tratamento para se avaliar a possibilidade de reuso.
276

Estudo do perfil de coagulação em pacientes oncológicos com injúria renal aguda / Study of coagulation profile in cancer patients with acute kidney injury

James Hung 04 March 2015 (has links)
Introdução: Pacientes com câncer frequentemente apresentam distúrbios de coagulação, que podem se manifestar clinicamente na forma de trombose ou simples alterações nos exames de hemostasia. A injúria renal aguda (IRA) é comum em pacientes oncológicos e pode ocorrer como consequência do próprio câncer; do tratamento; ou sepse secundária à imunossupressão causada pela quimioterapia. A IRA é encontrada em até 67% dos pacientes em UTI e está associada à alta mortalidade, além de resultar em maior custo e tempo na internação hospitalar. O sangramento causado pela uremia é uma complicação que pode ocorrer em pacientes com falência renal. O efeito da interação da IRA na coagulação dos pacientes com câncer ainda não está elucidado. Objetivo: Estudar o perfil de coagulação dos pacientes oncológicos com sepse grave ou choque séptico e avaliar o efeito da IRA na coagulação destes pacientes. Critérios de inclusão: pacientes maiores de 18 anos, portadores de tumores sólidos ou hematológicos, admitidos na UTI do ICESP com diagnóstico de sepse grave ou choque séptico. Critérios de exclusão: pacientes com insuficiência renal crônica em programa regular de diálise e pacientes com coagulopatia prévia ou história familiar de coagulopatia. Métodos: Foram estudados pacientes admitidos no período de agosto de 2012 a janeiro de 2014. A coleta de exames de sangue foi realizada no momento da admissão na UTI e ao apresentar IRA, pelo critério AKIN. O perfil de coagulação estudado compreendeu: TP, TTPa, D-dímero, fibrinogênio, fator VIII, avaliação de adesão e agregação plaquetária com Impact-R®, tromboelastografia e avaliação da geração de trombina. Dados clínicos e epidemiológicos foram obtidos a partir dos prontuários. Resultados: foram incluídos 144 pacientes na análise final. As características foram semelhantes nos grupos em relação à idade, IMC, sexo, e comorbidades tais como, hipertensão arterial e diabetes mellitus. Os testes convencionais de coagulação (TP, TT, TTPa) estavam alterados no grupo com IRA. Entretanto, a análise da coagulação pela tromboelastografia não demonstrou diferença entre os grupos com IRA comparados com o grupo que não apresentou IRA. A análise da função plaquetária pelo Impact-R® revelou que a uremia não piorou a adesão e agregação plaquetária. Observou-se que houve menor geração de trombina e nível de Ddímero mais elevado no grupo com IRA AKIN3. Regressão logística multivariada demonstrou que a necessidade de ventilação mecânica, nível de proteína C reativa mais elevada, e IRA estavam associados à maior mortalidade. Maior geração de trombina estava associada à menor mortalidade. Conclusão: a IRA em pacientes críticos oncológicos com sepse ou choque séptico está associada ao alargamento dos testes de coagulação convencionais (TP, TT, TTPa), devido à deficiência de alguns fatores de coagulação. Entretanto, a tromboelastografia, que analisa a hemostasia global do paciente, apresentou resultado normal devido à hiperativação da função plaquetária. O acúmulo de toxinas urêmicas, devido à injúria renal aguda, não levou à piora da função plaquetária. Pelo contrário, houve até um aumento na agregação e adesão plaquetária nos pacientes oncológicos. / Introduction: Patients with cancer often have coagulation disorders, which may manifest clinically as thrombosis or simple changes in hemostasis tests. Acute kidney injury (AKI) is frequent in cancer patients and may occur as a consequence of the cancer itself or due to the treatment or sepsis secondary to immunosuppression caused by chemotherapy. AKI is found in up to 67% of ICU (Intensive Care Unit) patients, associated with high mortality, and resulting in increased cost and stay in the hospital. Bleeding caused by uremia is a complication that can occur in patients with renal failure. The effect of the interaction between AKI and coagulation in cancer patients has not been yet elucidated. Objectives: To analyse the coagulation profile in cancer patients with severe sepsis or septic shock and evaluate the effect of AKI in the coagulation profile. Inclusion criteria: patients older than 18 years old with solid or hematological tumors admitted to the ICU, diagnosed with severe sepsis or septic shock. Exclusion criteria: patients with chronic renal failure undergoing regular dialysis program and patients with previous coagulopathy or family history of coagulopathy. Methods: We studied patients admitted to the ICU between August 2012 and January 2014. The collection of blood samples was performed at the time of ICU admission and at the time of AKI, according to the AKIN criteria. The coagulation profile included: PT, aPTT, D-dimer, fibrinogen, factor VIII, platelet adhesion and aggregation, thromboelastography and evaluation of thrombin generation. Clinical and epidemiological data were obtained from medical records. Results: A total of 144 patients was included in the final analysis. The following characteristics were similar between groups: age, BMI, gender, and comorbidities such as hypertension and diabetes mellitus. Conventional coagulation tests results (PT, TT, aPTT) were altered in the group with AKI. However, analysis of coagulation by thromboelastography showed no difference between groups with AKI compared with the group without AKI. Platelet function analysis by Impact-R® revealed that uremia has not worsened platelet adhesion and aggregation. It was observed that there was less thrombin generation and higher D-dimer level in the AKIN3 group. Multivariate logistic regression showed that the need for mechanical ventilation, higher level of C-reactive protein, and AKI were associated with higher mortality. Higher thrombin generation was associated with lower mortality. Conclusions: AKI in critically ill cancer patients with sepsis or septic shock is associated with abnormalities of conventional coagulation tests (PT, TT, aPTT) due to some coagulation factors deficiency. However, thromboelastography which analyzes the global hemostasis presented a normal result, probably due to platelet function hyperactivation. Furthermore, the accumulation of uremic toxins due to acute kidney injury did not worsen platelet function in cancer patients
277

Aplicação de coagulantes no afluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário. / Application of coagulants to anaerobic expanded bed reactor influent fed by domestic wastewater

Hélio Rodrigues dos Santos 20 April 2001 (has links)
Os reatores anaeróbios de tratamento de esgoto possibilitam elevada remoção de matéria orgânica, com menor custo em comparação com os processos aeróbios. Entretanto, esses reatores geralmente são pouco eficientes na remoção de nutrientes e seu efluente pode apresentar valores relativamente elevados de DQO e de sólidos suspensos. Por isso, investigou-se a aplicação de cloreto férrico e auxiliares de floculação no afluente de um reator anaeróbio de leito expandido em escala real (Volume = 32 m3; TDH = 3,2 h), no intuito de elevar as eficiências de remoção de DQO, turbidez, fósforo e sólidos. Foram realizados testes de Atividade Metanogênica para avaliar a toxicidade do cloreto férrico ao lodo do reator, mas nenhum efeito tóxico foi detectado para concentrações de até 500 mg FeCl3/l. Em seguida, foram realizados testes em reator de bancada (jar test), quando foi investigado o uso de cloreto férrico (dosagens entre 40 e 200 mg/l) em conjunto com um polímero catiônico, um polímero aniônico e amido natural de batata (dosagens entre 0,5 e 2,0 mg/l), sendo obtidos os melhores resultados com cloreto férrico e polímero aniônico. As eficiências médias diárias de remoção no reator de leito expandido foram elevadas de 64% para 71%, para DQO; de 47% para 59%, para turbidez; de 17% para 31%, para fósforo; e de 52% para 77%, para SST, quando aplicadas dosagens de 40 mg/l de cloreto férrico e 1,0 mg/l de polímero aniônico. / Anaerobic reactors for wastewater treatment have high capacity in removing organic matter and lower costs in comparison with aerobic processes. Nevertheless, anaerobic reactors generally are less efficient in nutrient removal and their effluents may present relatively high COD and total suspended solid (TSS) concentrations. Hence, the application of ferric chloride (FeCl3) and flocculant aids to a full-scale (Volume = 32 m3; HRT = 3,2 h) anaerobic expanded bed reactor influent was investigated to improve removal of COD, turbidity, phosphorous and solids. Methanogenic activity tests were conducted to evaluate toxicity of ferric chloride against methanogenic anaerobic reactor sludge. Tests showed that no toxic effect occurred before concentrations of FeCl3 reached 500 mg/l. Conventional bench-scale jar tests were conducted and ferric chloride was tested in combination with a cationic polymer, an anionic polymer and natural potato starch. Best results were obtained when ferric chloride was employed with anionic polymer. Average daily removal rates were increased from 64% to 71% for COD, from 47% to 59% for turbidity, from 17% to 31% for phosphorous and from 52% to 77% for TSS when dosages close to 40 mg/l of ferric chloride and 1,0 mg/l of anionic polymer were applied to anaerobic expanded bed reactor influent.
278

Avaliação de diferentes coagulantes para remoção de sólidos por flotação e sedimentação de água residuária de uma indústria metal-mecânica / Evaluation of different coagulants for removal of solids by flotation and sedimentation of wastewater from a metal-mechanic industry

Marcelo Almir Lopes 09 December 2011 (has links)
Uma das abordagens para minimizar o volume de captação de água potável e o descarte de efluentes é o reuso da água dentro da unidade industrial através de técnicas avançadas de tratamento como o sistema de osmose reversa, porém esse sistema exige um afluente com uma baixa quantidade de sólidos, além de outros requisitos. A água residuária utilizada nesse estudo é proveniente de uma empresa do ramo metal-mecânico que utiliza processos de coagulação-floculação-sedimentação como forma de remover os sólidos antes de um sistema de osmose reversa. A proposta deste trabalho foi avaliar três diferentes coagulantes (aluminato de sódio, cloreto férrico e uma mistura de dois coagulantes comerciais, Procytrat 100A e Procytrat 300) em processos de coagulação-floculação e separação de sólidos da fase líquida por sedimentação e flotação por ar dissolvido e também comparar os custos aproximados dos processos envolvidos. Foram realizados ensaios em testes de jarros e flotateste e com os dados obtidos construíram-se diagramas de coagulação-floculação e escolhidas as regiões de maior remoção de sólidos. Através das regiões escolhidas, foram feitas as comparações de eficiência de remoção e custos para cada coagulante estudado. Verificou-se que os diagramas de coagulação-floculação-sedimentação foram os que apresentaram as regiões de maior área com turbidez remanescente menor que 2%, principalmente para os coagulantes cloreto férrico e a mistura Procytrat 100A + Procytrat 300, chegando a alcançar valores próximos a 0,5%. A opção mais econômica foi alcançada com custo de cloreto férrico, na dosagem de 200 mg/L, pH igual a 8,3 e turbidez remanescente igual a 0,6%, de R$0,47/\'M POT.3\' de água tratada. Os diagramas de coagulação-floculação-flotação apresentaram regiões de turbidez remanescente com áreas bem mais reduzidas se comparadas aos diagramas de coagulação-floculação-sedimentação, sendo que não foram atingidos valores de turbidez remanescente menores que 1,5%. Os menores valores de turbidez remanescente para o processo de flotação foram encontrados utilizando-se como coagulante a mistura Procytrat 100A + Procytrat 300, sendo a opção mais econômica alcançada para pH igual a 3,3, dosagem de 60 mg/L e turbidez remanescente igual a 1,6%, com custo de R$0,33/\'M POT.3\' de água tratada. De um modo geral, para todos os coagulantes testados, as regiões escolhidas nos diagramas de coagulação-floculação-flotação, cujos valores de turbidez remanescente foram menores, estavam concentradas em valores de pH baixos (3,2 a 5,5), dosagens de coagulante reduzidas (10 a 80 mg/L) e dosagens de alcalinizante também reduzidas (0 a 60 mg/L de Ca(\'OH)IND.2\'). Esse comportamento foi contrário ao apresentado pelos diagramas coagulação-floculação-sedimentação cujos valores de turbidez remanescente foram menores em valores de pH mais altos (6,5 a 8,5), maiores dosagens de coagulante (40 a 380 mg/L) e altas dosagens de alcalinizante (100 a 400 mg/L de Ca(\'OH)IND.2\'). / One approach to minimize the consumption of drinking water and effluent disposal is the reuse of water within the plant through advanced treatment techniques such as reverse osmosis system, however, this system requires an affluent with a low amount of solids and other requirements. The wastewater used in this study comes from a metalworking company that uses coagulation-flocculation-sedimentation process as a way to remove the solids before a reverse osmosis system. The purpose of this study was to evaluate three different coagulants (sodium aluminate, ferric chloride and a mixture of two commercial coagulants, Procytrat 100A and Procytrat 300) in the process of coagulation-flocculation and separation of solids from the liquid phase by sedimentation and dissolved air flotation and also compare the approximate costs of the processes involved. Jar tests and flotatests were performed and the coagulation-flocculation diagrams were built. In the coagulation-flocculation diagrams were selected areas of higher solids removal. Through the chosen regions, comparisons were made of removal efficiency and cost study for each coagulant. It was found that the diagrams of coagulation-flocculation-sedimentation presented the areas of higher turbidity remaining area with less than 2%, mainly for the coagulants ferric chloride and the mixture Procytrat 100A + Procytrat 300, reaching values close to 0.5 %. The most economical option was achieved at a cost of ferric chloride at a dosage of 200 mg/L, pH 8.3, and the remaining turbidity equal to 0.6%, from R$ 0.47/\'M POT.3\' treated water. The diagrams of coagulation-flocculation-flotation showed regions with turbidity remaining areas much reduced compared to the diagrams of coagulation-flocculation-sedimentation, and the turbidity remaining values were more than 1.5%. The lower values of turbidity remaining for the flotation process were found using the mixture Procytrat 100A + Procytrat 300, and the most economical option was reached for a pH of 3.3, dosage of 60 mg/L and remaining turbidity equal to e 1.6%, at a cost of R$ 0.33/\'M POT.3\' of treated water. In general, for all coagulants tested, the selected regions in the diagrams of coagulation-flocculation-flotation, whose remaining turbidity values were lower, were concentrated in low pH values (3.2 to 5.5), dosages of coagulant reduced (10 to 80 mg/L) and dosages of alkaline also reduced (0 to 60 mg/L of Ca(\'OH)IND.2\'). This behavior was contrary to the diagrams presented by coagulation-flocculation-sedimentation whose remaining turbidity values were lower in higher pH values (6.5 to 8.5), larger amounts of coagulant (40 to 380 mg/L) and high doses of alkaline (100 to 400 mg/L Ca(\'OH)IND.2\').
279

Efeito da massa molecular das substâncias húmicas na eficiência da coagulação com o reagente de Fenton, floculação e flotação de águas de mesma cor verdadeira / Humic substances molecular weigth effect on coagulation with Fenton\'s reagent, flocculation and flotation of waters with the same true color

Marcelo De Julio 25 November 2005 (has links)
A presença de substâncias húmicas em águas destinadas ao abastecimento tem ocasionado diversos problemas, entre eles a formação de subprodutos halogenados, principalmente quando se emprega a pré-oxidação com cloro. Com o reagente de Fenton não há a possibilidade de formação desses indesejáveis compostos halogenados, pois o forte poder oxidativo do reagente de Fenton é devido ao radical hidroxila (OH). Aliado a isto, com o mesmo produto químico se pode ter a pré-oxidação e coagulação de compostos orgânicos, pois o reagente de Fenton consiste na aplicação de íons de Fe+2 e peróxido de hidrogênio em meio ácido, sendo o Fe+2 oxidado a Fe+3. Como esses íons formam espécies hidrolisadas que atuam como coagulantes, o reagente de Fenton pode ter a dupla função de oxidação e coagulação nos processos de tratamento. Por isso, neste trabalho foi proposta uma metodologia para emprego do reagente de Fenton como agente coagulante no tratamento de águas contendo cor elevada causada pela introdução de substâncias húmicas extraídas de turfa. Além disto, foi estudado o efeito da massa molecular das substâncias húmicas na eficiência da coagulação, floculação e flotação de águas; para isto foram preparadas 4 águas distintas apresentado a mesma cor verdadeira, mas com substâncias húmicas de diferentes massas moleculares, obtidas por fracionamento por ultrafiltração. Por meio da otimização da dosagem de coagulante e respectivo pH de coagulação e posterior construção dos diagramas de coagulação para cada água de estudo, verificou-se que a água preparada com as substâncias húmicas de menor massa molecular apresentou maior grau de dificuldade para tratamento, requerendo dosagens de coagulante (reagente de Fenton) bem mais elevadas em relação às águas preparadas com substâncias húmicas de maior massa molecular. Adicionalmente, foram realizados ensaios de filtração em areia após a flotação, procurando-se simular tratamento em ciclo completo, tendo sido constatado que com o reagente de Fenton empregado como agente coagulante, a água filtrada atendeu ao padrão de potabilidade vigente no Brasil em relação aos parâmetros medidos (cor aparente < ou = 3 uH, turbidez < 0,5 uT e ferro total residual < 0,005 mg/L). Os valores de absorvância e carbono orgânico total da água filtrada também foram muito pequenos, indicando que a formação dos subprodutos da desinfecção com cloro seriam insignificantes. / Humic substances\' presence in water destined for supply has brought many problems, such as halogenated byproducts formation, mainly when chlorine is used as preoxidant. With Fenton\'s reagent there is no formation possibility of these undesirable halogenated compounds, since the strong oxidative power of Fenton\'s reagent is due to hydroxyl radical (OH). In addition, with the same chemical product, it is possible to have the preoxidation and coagulation of organic compounds, because Fenton\'s reagent consists of Fe+2 ions and hydrogen peroxide application under acid conditions, with Fe+2 oxidized to Fe+3. Since these ions form hydrolyzed species that act as coagulants, Fenton\'s reagent can have the double function of oxidation and coagulation on treatment processes. Because of this, the current work proposed a methodology to use Fenton\'s reagent as coagulant agent in the treatment of waters having high true color caused by the introduction of humic substances extracted by peat. Besides this, humic substances molecular weight effect on coagulation, flocculation and flotation of waters was studied; for this, 4 distinct waters having the same true color were prepared, but with different humic substances molecular weights, obtained by ultrafiltration fractioning. Through optimization of coagulant dosage and respective coagulation pH and posterior construction of coagulation diagrams for each studied water, it was verified that the water prepared withthe smallest molecular weight humic substances was more difficult to treat, requiring higher coagulant (Fenton\'s reagent) dosages compared with the waters prepared with larger molecular weight humic substances. Furthermore, experiments of filtration after flotation were carried out, trying to simulate a complete cycle treatment, which verified that with Fenton\'s reagent, employed as coagulant agent, the filtered water reached the brazilian potable standards concerning the measured parameters (apparent color < ou = 3 HU, turbidity < 0.5 TU and residual total iron < 0.005 mg/L). The absorbance and total organic carbon values of filtered water were also very low, indicating that the disinfection byproducts formation with chlorine would be insignificant.
280

Influência do tamanho molecular aparente de substâncias húmicas aquáticas na eficiência da coagulação por hidroxicloreto de alumínio / Influence of apparent molecular size from aquatic humic substances in the efficiency of coagulation by aluminum hydroxychloride

Camila Tolledo Santos 16 November 2009 (has links)
Estações de tratamento de água que tratam águas com cor elevada, causada pela presença de substâncias húmicas, e baixa turbidez têm apresentado problemas operacionais, principalmente na coagulação. As substâncias húmicas aquáticas (SHA) apresentam moléculas de massa molecular variada, grande parte entre 500 Da e 10 kDa. Por esse motivo, as condições de coagulação (tipo e dosagem de coagulante e pH de coagulação) podem ser totalmente distintas no tratamento de águas com a mesma coloração, devido à presença de SHA com propriedades estruturais diferentes, conforme já observado em pesquisas recentes. Neste contexto, o presente trabalho estudou a influência do tamanho molecular aparente das SHA na coagulação por hidroxicloreto de alumínio e fez a comparação dos custos entre este coagulante e dois estudados anteriormente - sulfato de alumínio e cloreto férrico - para mesma eficiência de remoção de cor. Para isso, realizaram-se ensaios de coagulação seguida de filtração em jarteste com quatro águas de estudo preparadas com frações de diferentes tamanhos moleculares aparentes de SHA, com cor verdadeira de 100 uH e turbidez de 5,0 uT. A partir dos resultados encontrados, pode-se afirmar que há influência do tamanho molecular aparente de diferentes frações de substâncias húmicas aquáticas na coagulação por hidroxicloreto de alumínio. Observou-se a tendência de maior consumo de coagulante para a coagulação de frações de SHA de menores tamanhos moleculares aparentes, em uma faixa determinada de pH. Em relação aos custos, o cloreto férrico foi o coagulante que apresentou menor valor para tratamento (por filtração direta) de águas com elevada cor aparente devida a presença de SHA. / The water treatment plants that treat waters with high brown color caused by the presence of humic substances, and low turbidity have been presenting operational problems, mostly in the coagulation. The aquatic humic substances (AHS) present molecules of different molecular mass, most part between 500 Da and 10 kDa. Therefore, the coagulation terms (coagulant type and dosage and coagulation pH) can be totally distinct in waters treatment with the same coloration, due to the presence of AHS with different structural properties, as already observed in recent researches. In this context, the present work presented the influence of AHS\'s apparent molecular size in the coagulation for aluminum hydroxychloride and did the costs comparison between this coagulant and two studied previously - aluminum sulfate and ferric chloride - for same efficiency of the color removal. For that, it accomplished coagulation rehearsals followed by filtration in jar-test with four waters of study prepared with fractions of different AHS\'s apparent molecular sizes, with true color of 100 uH and turbidity of 5.0 uT. From the found results, it can affirm that there is influence of the apparent molecular size of different fractions from aquatic humic substances in the coagulation for aluminum hydroxychloride. The larger coagulant consumption tendency was observed for the AHS\'s fractions coagulation of smaller apparent molecular sizes, in a range determined by pH. Regarding the costs, the ferric chloride was the coagulant that presented smaller value for treatment (for direct filtration) of waters with high brown apparent color due the presence of AHS.

Page generated in 0.0988 seconds