51 |
INFLUÊNCIA DA INCORPORAÇÃO DE UM PLASTIFICANTE E UM POLIETILENO DE ALTO PESO MOLECULAR NAS PROPRIEDADES DE UMA RESINA EXPERIMENTAL E DIMINUIÇÃO DO ESTRESSE DE CONTRAÇÃO / Influence of the incorporation of a plasticizer and high molecular weight polyethylene on the properties of an experimental resin and shrinkage stress decrease.Dominguez, John Alexis 13 August 2015 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1
John Alexis Domingues.pdf: 1971333 bytes, checksum: 6d76db539da045af70dd08f004b5c7c8 (MD5)
Previous issue date: 2015-08-13 / The objectives of this study were: 1) to evaluate the degree of conversion, shrinkage stress, flexural and compressive strength of an experimental resin with a lactic polyacid and castor oil; 2) to evaluate the cytotoxicity of an experimental resin with a lactic polyacid, and castor oil; 3) evaluate, degree of conversion,
shrinkage stress, flexural and compressive strength an experimental resin with addition of a high molecular weight polyethylene; 4) to assess the cytotoxicity of an experimental resin with addition of a high molecular weight polyethylene.
Initially, it was synthesized a poly (lactic acid) (PLA) via a polycondensation process. After 24 hours, the castor oil (OR) was incorporated by an esterification process with N, N-Dicyclonecylcarbodimide and 99% 4-Dimethylamino-Pyridine
in 40 mL of tetrahydrofuran. After this, the blend was characterized by X-ray diffraction (XRPD), Raman spectroscopy, scanning electron microscopy (SEM) and shrinkage stress, where was proven the incorporation of PLA + OR in the experimental composite resin. In the third chapter, PLA + OR were manipulated
in two concentrations (1.5% and 3%) in an experimental composite: (2,2 bis [4- (2-hydroxy-3-metacrilatoxypropoxy) phenol] (BisGMA) Triethylene glycol dimethacrylate (TEGDMA), camphorquinone (CQ), N, N-dimethylaminoethyl
methacrylate (DEMA-EMA), butylated hydroxytoluene (BHT), silanated barium borosilicate glass, and the tests of degree of conversion, compressive and flexural strength and shrinkage stress were made. The cytotoxicity assay was done; a suspension of 3 x 103 cells/mL of culture medium was prepared. For this, the cells were detached from the bottom of the bottle by the addition of trypsin with EDTA, after incubation in 5% CO2 with 3 mL Eagle's medium supplemented culture. After 24 h incubation period, the culture medium was removed and 200
uL of a solution of culture medium and methylltetrazolium salt (MTT). Subsequently, the analysis of mitochondrial activity was performed in a spectrophotometer (Biotek EL 800, Biotek, Winooski, VT, USA) with a 10 wavelength of 570 nm. The data from each test were analyzed by one-way ANOVA. No significant differences were found (p <0.005) in compressive and
degree of conversion tests, and significant differences in shrinkage stress where obtained, up to 69% decrease. and flexion, statistically significant . In the fourth chapter, it was incorporated a high molecular weight polyethylene and
polypropiylene, in the experimental resin proposed in chapter two, at two concentrations (1.5% and 3%), and tested by degree of conversion, compressive and flexural strength and shrinkage stress. The data from each test were analyzed by one way ANOVA, finding no significant difference (p> 0.005) in
degree of conversion, compressive and flexural strength, and the contraction stress showed a significant reduction of up to 40%. Conclusion: PLA + castor oil and the high molecular weight polyethylene decreases the shrinkage stress and properties like flexural and compressive strength and degree of conversion were not influenced. / Os objetivos deste estudo foram: 1) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com um poliácido lático e óleo de rícino; 2) avaliar a citotoxicidade de uma resina
experimental com um poliácido lático e óleo de rícino; 3) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com adição de um polietileno de alto peso molecular e 4) avaliar a citotoxicidade de uma resina experimental com adição de um polietileno de alto peso molecular. Previamente realizou-se a síntese de um Poli-ácido lático (PLA) por meio de um processo de policondensação. Após 24 horas, foi incorporado o óleo de rícino (OR) por meio de um processo de esterificação junto
a N,N-Diciclonecilcarbodimida e 4-Dimetilamino-Piridina a 99% em 40 mL de tetrahidrofeurano. Em seguida, o conjunto foi caracterizado por difração de espectroscopia Raman, microscopia eletrônica de varredura (MEV) e estresse
de contração, onde foi comprovada a incorporação do PLA+OR numa resina composta experimental. No terceiro capítulo foi feita a incorporação do PLA+OR em duas concentrações (1,5% e 3%) numa resina composta experimental: (2,2 bis[4-(2-hidroxi-3-metacrilatoxipropoxi)fenol](BisGMA), Trietilglicoldimetacrilato
(TEGDMA), canforoquinona (CQ), N,N– dimetilaminoetil metacrilato (DMAEMA), hidroxitolueno butilado (BHT), vidro de borossilicato de bário silanizado e foram realizados os testes de flexão, compressão, grau de conversão e estresse
de contração. Foi feito o teste de citotoxicidade, uma suspensão de 3 x 103 células/mL de meio de cultura foi preparada. Para isso, as células foram descoladas do fundo da garrafa por meio da adição de tripsina com EDTA, após incubação em estufa com 5% de CO2 e 3 mL de meio de cultura Eagle suplementado. Após o período de incubação de 24 h, o meio de cultura foi
removido e 200 μL de uma solução de meio de cultura e sal metiltetrazólio (MTT).Posteriormente, a análise da atividade mitocondrial foi realizada em espectrofotômetro (Biotek EL 800, Biotek, Winooski, VT, EUA) com comprimento
de onda de 570 nm. Os dados obtidos de cada teste foram analisados com ANOVA um fator. Não encontrou-se diferença significativa (p> 0.005) nos testes de compressão e grau de conversão; já para o teste de estresse de contração,
houve diminuição estatisticamente significativa de até 69% e no teste de resistência à flexão . No quarto capítulo foi feita a incorporação de um polipropileno (PP) e o polietileno de ultra-alto peso molecular (UTEC) a uma resina experimental com os mesmos materiais manipulados no capítulo dois, em
duas concentrações (1,5% e 3%), e realizados os testes de compressão, flexão, grau de conversão e estresse de contração. Os dados de cada teste foram analisados com ANOVA um fator. Não houve diferença significativa (p> 0.005) nos testes de compressão, flexão e grau de conversão; já para o teste de
estresse de contração houve diminuição estatisticamente significativa de até 40%. Conclusão: OPLA+óleo de rícino e o polietileno de ultra alto peso molecular em 1,5%, diminuíram o estresse de contração e propriedades como resistência à flexão, compressão e grau de conversão não foram influenciadas.
|
52 |
Avaliação numérico-experimental da distribuição de tensões geradas pela contração de polimerização de resinas compostas / Numerical-experimental evaluation of the distribution of the stresses produced by polymerization shrinkage of composite resinsBaggio, Rafael 23 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:13Z (GMT). No. of bitstreams: 1
Rafael Baggio.pdf: 2179064 bytes, checksum: 054756974bbbe9db77284217ea63ed04 (MD5)
Previous issue date: 2010-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to evaluate the distribution of the stresses generated by the polymerization shrinkage of three composite resins [FiltekTM Z250 (3M ESPE, St. Paul, Minn., USA); FiltekTM Z350 (3M ESPE, St. Paul, Minn., USA) and P-90 (3M ESPE, St. Paul, Minn., USA)], with mechanical tests and finite element analysis (FEM). Ten samples of each composite resin were prepared in metal matrix of 25 X 2
X 2 mm and were tested in the flexural 3 points bend strength in a universal testing machine and a cross-head speed of 0.5 mm / min. After, more 10 samples of each composite resin were prepared in a metal matrix in the form of an hourglass
measuring 10 x 3 x 1.5 mm with a central bottleneck of 1.5 mm were submitted to a tensile strength in an universal testing machine with a load cell of 10 N and a crosshead
speed of 1.0 mm / min until material failure occurred. After, FEM analysis was made simulating the effects of a class V restoration. In the mechanical tests of tensile strength (MPa) and 3 points bend flexural strength (MPa) respectively, all composites obtained similar results, being to FiltekTM Z-250 (36.51 ± 8.14 and 158.51 ± 31.80), to FiltekTM Z-350 (34.43 ± 6.49 and 146.65 ± 18.83) and to FiltekTM P90 (37.35 ± 7.51
and 148.00 ± 26.24) with no statistical differences by Two-way ANOVA test andBonferroni (alpha = 0.05) post-hoc. In the FEM analysis, the silorane based resin (FiltekTM P90) showed lower values of tension produced by polymerization shrinkage and better able to dissipate it by the adjacent structures. / Este trabalho tem como objetivo avaliar a distribuição de tensões geradas pela contração de polimerização de 3 resinas compostas [FiltekTM Z-250 (3M ESPE, St. Paul, Minn., USA); FiltekTM Z-350 (3M ESPE, St. Paul, Minn., USA) e P90 (3M ESPE, St. Paul, Minn., USA)], através de testes mecânicos e análise por meio do método de elementos finitos. Inicialmente, 10 cp de cada resina composta foram confeccionados em matrizes metálicas de 25 X 2 X 2 mm e submetidos ao ensaio de resistência flexural de 3 pontos em uma Máquina de Ensaios Universal à uma velocidade de 0,5 mm/min. Para o teste de resistência à tração, foram confeccionados 10 cp para cada grupo de resina composta, mas agora em uma
matriz metálica em forma de ampulheta medindo 10 x 3 x 1,5 mm com um estrangulamento central de 1,5 mm. Em seguida, as amostras foram submetidas ao teste de resistência à tração em uma Máquina de Ensaios Universal com uma célula
de carga de 10 N a uma velocidade de 1,0 mm/min até que ocorreu a fratura no material. Com os dados obtidos em laboratório, uma simulação computacional foi realizada através do MEF, simulando os efeitos de uma restauração classe V na
região cervical da face vestibular de um pré-molar. Nos testes mecânicos, após análise de variância ANOVA dois critério e pós-teste de Bonferroni com alfa igual a 0,05, não foram encontradas diferenças estatísticas para a resistência à tração (MPa) e resistência flexural (MPa) respectivamente entre as resinas FiltekTM Z-250 (36,51 ± 8,14 e 158,51 ± 31,80), FiltekTM Z-350 (34,43 ± 6,49 e 146,65 ± 18,83) e
FiltekTM P90 (37,35 ± 7,51 e 148,00 ± 26,24). Na análise pelo método de elementos finitos, a resina à base de silorano (FiltekTM P90) obteve menores valores de tensões
produzidas pela contração de polimerização e conseguiu uma melhor dissipação da mesma pelas estruturas adjacentes.
|
53 |
Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadasRastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1
MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5)
Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets
bonded with fluoride-releasing composite resins, and to compare them to a conventional resin.
For this study, sixty premolars extracted due to orthodontic reasons were used, which were
divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and
Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at
37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the
specimens were submitted to the shear bond strength test, in occluso-gingival direction, in
Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis,
Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results
demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20
MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis
determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the
averages of the three groups were significantly different among themselves (p<0.05), with the
highest resistance for the Concise Group and the lowest for the Ultrabond Group. However,
all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes
colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este
estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram
divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M),
Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os
corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados
com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram
submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina
Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos
dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste
de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ±
6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de
16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou
diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001).
O teste de Tukey evidenciou que as médias dos três grupos foram significativamente
diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para
o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva
adequada para uso clínico.
|
54 |
Avaliação do grau de conversão de uma resina composta fotoativada por lâmpada halógena e LEDs, por meio de espectrometria no infravermelho e ultravioletaDaniel, Sandra Cristina Scarbi 16 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:22Z (GMT). No. of bitstreams: 1
Sandracr.pdf: 955996 bytes, checksum: 8d2e096cd1c87011d908615d47978334 (MD5)
Previous issue date: 2006-02-16 / The aim of this study was to evaluate the quantity of residual monomers of a
microhibrid composite resin, photocured with different types of light curing units:
halogen and LEDs based on different times of photopolymerization (10, 20 and 40
seconds). Samples of the composite resin were made with Teflon bipartite matrix with
a center hole of 6 mm diameter compatible with the tips of the light curing units. The
distance of the light guide curing unit to the composite samples was 4 mm. The
average a width of the samples Charisma® composite resin color A2 and SL were 2
mm. The curing units used were Optilux 401 (Demetron) and Optilight LD III
(Gnatus). The materials were prepared and weighed on an accuracy scale and
stored in solvent, in the dark, at room temperature for 24 hours. The solvent used to
separate the organic and inorganic load was chloroform thirty six samples were
made, stored in chloroform and analysed with infrared spectroscopy (FTIR) and the
presence of carbon double bonds were found. Another solvent investigated in this
study was methanol, because it is considered an efficient solvent for extracting
present monomers in the resin, with an advantage because it acts as an inhibitor in
this type of polymerization while maintaining the characteristic of the sample for
quantitative analysis. Parallel to that, one hundred new samples were made. They
were appropriately stored in methanol and analysed with UV- visible light
spectroscopy (UV-Vis), through observance spectrum. The collected data was
analysed in Origin 5.0 programs at the peak of observance in the same wavelength.
The percentage of residual monomers was analysed by ANOVA and Games Howell
tests. The results indicated that Charisma® composite resin color A2 showed less
residual monomers. The halogen and LEDs light cure units showed the same
percentage of residual monomers results, or rather, it showed a larger conversion of
monomers in polymers. The LED based system promoted a smaller conversion
degree compared to halogen light. The 10, 20 and 40 seconds of photocured
presented the same quantity of residual monomers. / Neste trabalho foi avaliada a quantidade de monômeros residuais de uma resina
composta micro-híbrida de duas cores, com dois aparelhos: halógena e outro à base
de LEDs, em três tempos de fotoativação (10, 20 e 40 s). Para a confecção dos
corpos-de-prova foi utilizada uma matriz bipartida de teflon com orifício central de 6
mm de diâmetro, compatível com as pontas dos equipamentos fotoativadores. A
distância da ponta ativa do fotopolimerizador aos corpos-de-prova foi de 4 mm. A
espessura média dos corpos-de-prova de resina composta Charisma® (Heraeus
Kulzer) cor A2 e SL foi de 2 mm. Os aparelhos utilizados foram: lâmpada halógena
Optilux 401 (Demetron) e Optilight LD III (Gnatus), à base de LEDs. Os materiais
foram preparados e pesados em balança analítica e armazenados durante 24 horas
em solventes ao abrigo da luz e à temperatura ambiente. O solvente utilizado para
separar a fração orgânica das partículas inorgânicas foi o clorofórmio. Foram
confeccionados 36 corpos-de-prova armazenados em clorofórmio e analisados em
espectrômetro de infravermelho (FTIR) e foi verificada a presença das ligações
duplas de carbono-carbono. Outro solvente utilizado neste experimento foi o
metanol, por ser um solvente eficiente para a extração dos monômeros presentes na
resina, com a vantagem de agir como inibidor deste tipo de polimerização,
preservando as características da amostra para a análise quantitativa.
Paralelamente foram confeccionados 120 corpos-de-prova devidamente
armazenados em metanol e analisados em espectrômetro de ultravioleta-visível (UVVis)
ou equipamento de espectrometria na região do ultravioleta-visível, através de
espectros de absorvância. A leitura e interpretação dos dados obtidos foram feitos
no programa Origin 5,0 nos picos de maior absorvância (%A) no mesmo
comprimento de onda (nm). A porcentagem de monômeros residuais foi analisada
pelo teste de Variância e teste de Games Howel. Os resultados evidenciaram que a
resina composta Charisma® cor SL apresentou uma menor quantidade de
monômero residual, ou seja, apresentou uma maior conversão de monômeros em
polímeros. O sistema à base de LEDs promoveu um menor grau de conversão
comparado a lâmpada halógena. Os tempos de 10, 20 e 40 s de fotoativação
proporcionaram a mesma quantidade de monômeros residuais.
|
55 |
Avaliação espectrofotométrica da estabilidade de cor de materiais restauradores estéticosSamra, Adriana Postiglione Bührer 22 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1
AdrianaPostiglione.pdf: 1074589 bytes, checksum: ebd4e6efb3931ba759be23147fe7f4b2 (MD5)
Previous issue date: 2004-07-22 / Color match is one of the most important characteristics of the aesthetics restorative materials. Color stability is a demanding characteristic of the restorative
material as though as it indicates its chemical stability. The purpose of this research is to verify the color stability of five aesthetic restorative materials when immersed in coffee solution and the efficiency of professional prophylaxis on pigmentation
reduction after the staining. There were built 71 specimens, divided in five groups,made of one direct composite resin (Tetric Ceram – Ivoclar/Vivadent – G1), three indirect composite resins (Targis – voclar/Vivadent – G2; Resilab Master – Wilcos – G3; belleGlass HP – Kerr – G4) and one porcelain (IPS Empress 2 – Ivoclar/Vivadent – G5), with the dimensions of 17 mm x 1mm. The specimens were
immersed in staining media of coffee for 15 days, stored in controlled temperature of 37±1C at dark. In the sequency, they received a professional prophylaxis with
sodium bicarbonate. The evaluations were made after 1, 7 e 15 days and after the prophylaxis, by means of reflectance spectrophotometry. Data were submitted to two-way ANOVA (p<0,001) and post-hoc tests with estathistical difference between G1 / G3 and the other groups; G2 / G4 and the other groups; and G5 and all the others. It was concluded that G1 e G3 showed the greatest color changes, lollowed
by G2 and G4 and G5 showed the smallest changes. Professional prophylaxis was efficient to reduce the staining for all the materials tested. / A estabilidade de cor é indispensável para a durabilidade do tratamento restaurador estético. O objetivo deste trabalho é verificar a estabilidade de cor de cinco materiais restauradores submetidos a meio corante de café e a eficácia da profilaxia em reduzir a pigmentação decorrente do meio corante. Foram confeccionados 71 corpos-de-prova, divididos em cinco grupos (G1- resina composta Tetric Ceram – Ivoclar/Vivadent , G2, G3 e G4- resinas laboratoriais de
segunda geração, respectivamente Targis – Ivoclar/Vivadent; Resilab Máster – Wilcos; belleGlass HP – Kerr e G5- porcelana IPS Empress 2 – Ivoclar/vivadent) , com 17 mm de diâmetro por 1 mm de espessura. Os corpos-de-prova foram
mantidos imersos em solução de café por 15 dias, em estufa com temperatura controlada de 37± 1 C ao abrigo da luz. Na seqüência, foram submetidos a profilaxia com bicarbonato de sódio. As avaliações foram realizadas depois de 1, 7 e
15 dias e após profilaxia, por espectrofotometria de reflectância. A variável E foi avaliada em relação aos fatores período experimental e tempo, utilizando-se teste ANOVA a dois critérios (p<0,001). Ao se proceder aos testes pot-hoc constatou-se diferenças significativas entre G1 e G3 e os demais, entre G2 e G4 e os demais e entre G5 e todos os restantes. Concluiu-se que G1 e G3 apresentaram as maiores
alterações de cor, enquanto que G2 e G4, postos intermediários e G5, apresentou a menor alteração, que foi mais intensa nos períodos de 1 dia e 7 dias para todos os
materiais. A profilaxia foi eficiente para reduzir a alteração de cor.
|
56 |
Avaliação da microdureza superficial de resinas compostas extraclaras fotopolimerizadas por luz halógenas e LEDs. descrição das caracteristícas dos aparelhos fotopomerizadoresCotrina, Leyla Antoinette Delgado 23 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1
Leyla Antoinette Delgado Cotrina.pdf: 1205647 bytes, checksum: 64a5a6bbc08abd8e9aef28e74483da56 (MD5)
Previous issue date: 2004-07-23 / DELGADO, L. Evaluation of the superficial microhardness of extra-light
composite resins photocured by Halogen Light and LEDs. Description the
characteristics of the light sources. Ponta Grossa, 2004. 129 Dissertação
(Mestrado em Clínica Integrada) – Faculdade de Odontologia, Universidade Estadual
de Ponta Grossa.
The purpose of this study was to evaluate the superficial microhardness of four extralight
microhibrid composite resins photocured with different types of light curing units:
Halogen and LEDs. The emission spectrum (nm) and power (mW) of the curing units
were tested using the spectrometer USB2000 (Ocean Optics) and the Power Meter
(Ophir). The light intensity (mW/cm2) was determined through the value of power and
area the light guide of each unit (i=P/A). The resins and colors used were: Tetric®
Ceram (Ivoclar Vivadent) A2 and XL; FiltekTM Z250 (3M-ESPE) A2 and B0.5;
Charisma® (Heraeus Kulzer) A2 and SL; and Esthet X (Dentsply) A2 and XL. The
curing units used were: Curing Light 2500 (3M-ESPE) and Elipar® FreeLight (3MESPE).
Metallic matrixes were made with a hole of 5mm diameter and 2 mm thick.
Samples of the resins were made on these matrixes and were marked and storaged
in dry, dark jars for 24 hours. After this, the samples were evaluated using Vickers
microhardness test through the digital microhardmeter MMT-3 (Buehler) with 50 gf
charge for 30 seconds. Data collected was analyzed with a mutlifactorial variance
and Tukey tests. T-test was used on paired samples to determine significant
difference between surfaces. Also was calculated the percentage of depth of cure.
Results showed that the emission spectrum of the LED curing unit was more reduced
than the halogen curing unit (430–520nm and 400-520nm respectively).
Nevertheless, the halogen curing unit presented a greater power and intensity of
light. The factors analyzed (type of resin, color and light source) influenced the
microhardness values. It was found that the extra-light color resins presented the
least values of microhardness independent to the light source. The LEDs curing units
presented the least values of superficial microhardness. The Tetric® Ceram XL resin
composite showed percentage of depth of cure less 80%, independent to the light
source. The same occurred with A2 and XL colors the Charisma® resin composite
when cured with LEDs unit. / DELGADO, L. Avaliação da microdureza superficial de resinas compostas
extraclaras fotopolimerizadas por luz halógena e LEDs. Descrição das
características dos aparelhos fotopolimerizadores. Ponta Grossa, 2004. 129.
Dissertação (Mestrado em Clínica Integrada) – Faculdade de Odontologia,
Universidade Estadual de Ponta Grossa.
O objetivo deste trabalho foi avaliar a microdureza superficial de quatro resinas
compostas microhíbridas de cor extraclara quando fotopolimerizadas com duas
fontes de luz: halógena e LEDs. Paralelamente determinou-se o espectro de
emissão (nm) e a potência (W) dos aparelhos testados através do espectrômetro
USB2000 (Ocean Optics) e o Power Meter (Ophir) respectivamente. A intensidade
de luz (mW/cm2) foi calculada através do valor da potência e da área da ponta ativa
de cada aparelho (i=P/A). As resinas compostas utilizadas foram: Tetric® Ceram
(Ivoclar Vivadent) A2 e XL, FiltekTM Z250 (3M-ESPE) A2 e B0.5, Charisma® (Heraeus
Kulzer) A2 e SL e Esthet X (Dentsply) A2 e XL. Os aparelhos utilizados foram o
aparelho Curing Light 2500 (3M-ESPE) e Elipar® FreeLight (3M-ESPE). Para a
confecção dos corpos-de-prova foram utilizadas matrizes metálicas que com orifício
central de 5 mm de diâmetro por 2 mm de espessura. Os corpos-de-prova foram
identificados e armazenados em recipientes secos e ao abrigo da luz durante 24
horas. Passado este tempo, foram submetidos ao teste de microdureza Vickers
através do microdurômetro digital MMT-3 (Buehler) com carga de 50 gf durante 30
segundos. Os valores de microdureza foram analisados através da análise de
variância multifatorial e teste de Tukey. O teste t para amostras pareadas foi utilizado
para determinar diferenças entre as superfícies. Também foi calculada a
porcentagem de profundidade de polimerização. Os resultados evidenciaram que o
espectro de emissão do aparelho à base de LEDs é mais estreito do que do
aparelho de luz halógena, sendo que este último apresentou maior potência e maior
intensidade de luz. Os fatores analisados (resina composta, cor e fonte de luz)
influenciaram nos valores de microdureza. Concluiu-se que a cor extraclara obteve
os menores valores de microdureza independentemente do tipo de fonte de luz
utilizada e o aparelho à base de LEDs proporcionou os valores mais baixos de
microdureza superficial. A resina composta Tetric® Ceram cor XL atingiu
porcentagem de polimerização inferior a 80%, independentemente do tipo de fonte
utilizada. As cores A2 e XL da resina composta Charisma® não obtiveram
porcentagens de profundidade de polimerização acima de 80% quando
fotopolimerizada com o aparelho à base de LEDs.
|
57 |
Liberação de Bisfenol A de sistemas adesivos resinosos ortodônticos por meio de cromatografia gasosa - Estudo in vitro e in vivo / Release of bisphenol A resinous orthodontic adhesives by gas chromatography. In vitro and In vivo studyMarilia Rodrigues Moreira 19 March 2015 (has links)
O objetivo deste trabalho foi avaliar a liberação de Bisfenol A (BPA) de sistemas adesivos resinosos ortodônticos in vitro e in vivo. No estudo in vitro foram testadas 5 marcas comerciais de sistemas adesivos resinosos ortodônticos (Eagle Spectrum, Enlight, Light Bond, Mono Lok II e Transbond XT). Por meio da simulação de exposição intraoral, os corpos de prova foram imersos numa solução água/etanol e a liberação de BPA foi medida nos tempos de 30 minutos, 24 horas, 1 dia, 1 semana e 1 mês. No estudo in vivo utilizou-se amostra composta por 20 pacientes com indicação para tratamento ortodôntico com aparelhos fixos. Foram coletadas amostras de saliva em 5 tempos: antes, 30 minutos, 24 horas, 1 dia, 1 semana e 1 mês após a colagem dos bráquetes e as de urina em 4 tempos: antes, 1 dia, 1 semana e 1 mês após a colagem. Todos os compósitos avaliados liberaram pequena quantidade de BPA, sendo que o compósito Enlight-ORMCOR foi o que apresentou maior liberação,1020 ng/g no tempo de 1 mês. Os maiores níveis de BPA na saliva, foram encontrados no tempo de 30 minutos (1,0445 ng/mL) e na urina, 24 horas (5,035 ng/mL) após a colagem dos bráquetes. Mesmo que as quantidades de BPA liberadas fossem pequenas, houve diferença significativa quando esses valores foram comparados com os níveis iniciais, sugerindo aumento da quantidade de BPA no organismo com a colagem dos bráquetes ortodônticos. Como a literatura especializada têm destacado os potenciais tóxicos do BPA e têm sugerido alterações celulares \"com baixas\" doses, mais estudos são necessários para se chegar a um consenso no sentido de propiciar segurança no uso desses materiais. / The purpose of this study was measure the release of Bisphenol A (BPA) from the orthodontic resinous adhesive systems in vitro and in vivo. The study was divided into two stages: At in vitro study, five trademarks of Resinous Adhesive Systems (Eagle Spectrum, Enlight, Light Bond, Mono Lok II and Transbond XT) was tested. The samples were immersed in a water/ethanol solution simulating the intraoral exposition and the release of BPA was measured at times of 30 minutes, 24 hours, 1 day, 1 week and 1 month. At in vivo study, 20 patients with indication to fixed orthodontic appliances were used. Samples of saliva and urine were collected in these patients at previously determined time. To the saliva, it was collected 5 times ( before bonding the orthodontic brackets and 30 minutes, 24 hours, 1 day, 1 week and 1 month after this procedure); to the urine, it was collected 4 times ( before, 1 day, 1 week, 1 month, after bonding the orthodontic brackets). All the tested resinous adhesives released a small quantity of BPA, with peack at 1 month, with Enlight resinous presenting the highest level (1020 ng/g). The peack level in saliva (130445 ng/ml) and urine (5.035 ng/ml) were found in 30 minutes and 24 hours after the bonding of fixed appliances, respectively. However the quantities of released BPA are small which validate the security of the procedure. A significant difference was observed when these values were compared to the initial levels, suggesting a correlation of the increase of the quantity of BPA in the body and the bonding of the orthodontic appliances. As several studies have reported, the probable toxic effect of BPA and cellular changes in \"low doses\", more studies are necessary to reach a consensus. to provide security in the use of such materials.
|
58 |
An in-vitro study of the physical properties of core build-up materialsAsia, Winifred January 2017 (has links)
Magister Chirurgiae Dentium - MChD (Prosthodontics) / The aim of this study was to evaluate and compare the physical properties of two core
build-up materials (ParaCore and CoreXflow) and compare this to conventional composite
material (Filtek Supreme Plus and SDR Flow) used as core build-up material.
|
59 |
Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a compositeAdriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
|
60 |
Deflexão cuspídea e resistência à fratura em dentes restaurados /Rocha, Daniel Maranha da. January 2010 (has links)
Orientador: Maria Amelia Maximo de Araújo / Banca: Diego Klee de Vasconcelos / Banca: Sérgio Ricardo Badini / Banca: Clovis Pagani / Banca: Rebeca Di Nicoló / Resumo: A proposta desse estudo foi avaliar a deflexão cuspídea e a resistência à fratura de pré-molares, com e sem tratamento endodôntico, restaurados com diferentes técnicas e materiais restauradores. Para tal foram utilizados 60 pré-molares hígidos, extraídos por motivos ortodônticos que foram divididos em 6 grupos. Seis dentes foram mantidos hígidos, formando o grupo controle positivo (C POS), outros 6 receberam preparos tipo MOD e não receberam procedimentos restauradores formando o Grupo controle negativo (C NEG). Os demais 48 dentes foram divididos em 4 grupos de 12 dentes que foram restaurados de acordo com cada grupo. No grupo RC os dentes foram restaurados diretamente com resina composta, os demais grupos receberam tratamento endodôntico. No grupo CIV, os dentes tiveram as suas câmaras pulpares preenchidas com cimento de ionômero de vidro e posteriormente restauradas com resina composta, no grupo PM os dentes receberam pinos metálicos e foram restaurados com resina composta e por fim, os dentes do grupo PF receberam pinos de fibra de vidro e foram restaurados diretamente com resina composta. Os corpos-de-prova foram então submetidos a um ensaio não destrutivo de compressão a fim de se realizar a medição de deflexão das cúspides dos dentes de cada grupo e posteriormente, realizou-se o ensaio destrutivo a fim de registrar as medidas de resistência à fratura de cada grupo envolvido. Podem-se perceber diferenças estatisticamente significantes entre os grupos experimentais e os grupos controle, tanto para a deflexão das cúspides (CNEG: 81,0 με; CPOS: 5,20 με; RC: 17,73 με; CIV: 17,63 με; PF: 20,61 με; PM: 24,29 με) quanto para os valores de resistência à fratura (CNEG: 5,212 Kgf; CPOS: 128,22 Kgf; RC: 48,89 Kgf; CIV: 18,41 Kgf; PF: 29,81 Kgf; PM: 37,51 Kgf). Entre os grupos experimentais podem-se notar diferenças estatisticamente significantes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate de cuspal deflection and the fracture resistance of pre-molars, with and without endodontic therapy, using different restorative techniques and materials. Sixty sound teeth, extracted by orthodontic reasons were divided in 6 groups. Six teeth remained unprepared and formed the positive control group, other 6 teeth were MOD prepared and remained unrestored forming the negative control group. The remaining 48 teeth were divided in 4 groups with 12 teeth each and were restored following the groups. The RC group teeth were directly restored with composite resins. The other 3 groups received endodontic therapy. At the CIV group, the pulpal chambers of the endodontic treated teeth were fulfilled with glass ionomer cements an then directly restored with composite resin, the PM group teeth were restored with a metallic post and then directly restored with composite resin, in the PF group were used a fiber glass post and then direct composite restoration. The specimens was submitted first to non-destructive compression test due to cuspal deflection measurements, and then submitted to a destructive compression test to evaluate the fracture resistance of the specimens. Statistical differences were perceived when the experimental groups were compared to the control groups thus cuspal deflection (CNEG: 81,0 με; CPOS: 5,20 με; RC: 17,73 με; CIV: 17,63 με; PF: 20,61 με; PM: 24,29 με) and fracture resistance (CNEG: 5,212 Kgf; CPOS: 128,22 Kgf; RC: 48,89 Kgf; CIV: 18,41 Kgf; PF: 29,81 Kgf; PM: 37,51 Kgf). Differences between the experimental groups were verified both cuspal deflection, with a better performance of the RC and the CIV groups. The PM group showed the highest values of cuspal deflection. Concerning fracture resistance, the highest values were presented by the RC and CIV groups and the worst performance presented... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.1254 seconds