• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Matériau composite à base de bois et liant inorganique contribuant au confort thermique des bâtiments

Vu, Viet-Anh 19 February 2021 (has links)
Ce projet de recherche consiste à développer un nouveau matériau afin d’améliorer la performance énergétique des bâtiments, tout en réduisant l’empreinte carbone. Le nouveau matériau qui joue le rôle de revêtement mural pourrait remplacer les panneaux de gypse et permettre de réduire les écarts de température à l’intérieur des bâtiments, augmentant ainsi le confort des occupants tout en réduisant les besoins en climatisation et en chauffage. Trois objectifs spécifiques ont donc été établis dans le cadre du présent projet de recherche. Le premier consiste à développer la mise en forme et la formulation de panneaux bois-ciment-cendre de bois-poudre de pierre. Le second vise à caractériser ces panneaux quant à leurs propriétés mécaniques et thermiques, à leur résistance à l’absorption d’eau et à leur réaction au feu. Le troisième consiste à évaluer la performance thermique de ces panneaux à l’aide de deux maisonnettes expérimentales instrumentées. Le choix des matières premières a été fait sur la base de leur capacité thermique, leur densité et leur compatibilité. Ensuite, elles ont été caractérisées quant à leur composition chimique, leur granulométrie et leurs propriétés physiques. Les combinaisons de composantes qui ont été finalement retenues pour les panneaux sont les suivantes : particules de bois-ciment-cendre de bois et particules de bois-ciment-pierre de stéatite. La formulation appropriée à chaque type de panneau a été déterminée en termes de proportion massique eau/ciment, bois/ciment et produit d’addition/ciment sur la base de la maniabilité de la pâte et de la densité du matériau composite obtenu. Les panneaux composites produits ont été caractérisés quant à leurs propriétés mécaniques, physiques, thermiques et à leur comportement au feu et à leur structure interne caractérisée par microscopie électronique à balayage. Le pourcentage de remplacement optimal du ciment par de la cendre de bois est de 30%massique. À ce niveau de remplacement, les propriétés mécaniques du panneau sont légèrement réduites(réduction de 12% de la résistance à la flexion et de 21% de la résistance à l’arrachement des vis) par rapport à un panneau sans produit de remplacement. Au-delà de 30% de remplacement, les propriétés diminuent significativement. La stéatite nous offre une bonne qualité de surface du panneau, comparable à la surface de papier du gypse mais sans papier. Le pourcentage optimal de remplacement du ciment par la stéatite est de 15% massique. Les propriétés mécaniques sont améliorées (augmentation de 69% de la résistance à la flexion, de 37% de la résistance à l’arrachement des vis). Ces panneaux peuvent être coupés facilement avec une scie à main de la même manière que le panneau de gypse. Par conséquent, le processus d'installation du panneau est essentiellement le même. Ces panneaux ont une bonne résistance à l'eau. Les panneaux bois-ciment-poudre de stéatite ont de plus un meilleur comportement au feu que les panneaux de gypse. En effet, ils ne présentent pas une flamme visuelle après 20 minutes d’exposition au feu (une minute pour le panneau en gypse) sous un flux radiatif de 50 kW.m-2. Leur chaleur spécifique (15% de remplacement du ciment par la stéatite) est supérieure à celle du panneau en gypse de 38%. Des panneaux de gypse et des panneaux bois-ciment-poudre de stéatite ont été installés sur les murs intérieurs de maisonnettes expérimentales. Les résultats de mesures réalisées de mars à juillet 2019 montrent que la consommation en chauffage de la maisonnette avec des panneaux bois-ciment-poudre de stéatite a diminué de 7% par rapport à celle de la maisonnette avec panneaux intérieurs de gypse lorsque la plage de températures extérieures était de -9°C à 10°C, sans chauffage intérieur. La température intérieure de la maisonnette avec des panneaux bois-ciment-poudre de stéatite est plus confortable lors d’une journée ensoleillée. La différence des amplitudes de température intérieure quotidienne entre les deux maisonnettes a atteint 2,1°C pour une journée très chaude lorsque la température extérieure a atteint 28°C. / This research project consists to develop a new material in order to improve the energy performance of buildings but also the reduction of the carbon footprint of the materials used. The new material, used as wall covering, could help replace gypsum boards and reduce temperature differences inside buildings, thus increasing building comfort while reducing the need for air conditioning and heating. Three specific objectives have been established for this research project. The first objective is to develop the fabrication method and formulation of wood-cement-wood ash-stone powder panels. The second objective aims to characterize these panels in terms of mechanical and thermal properties, water absorption resistance, and fire resistance. The third objective consists of evaluating the thermal performance of these panels using two instrumented experimental huts. The choice of raw materials was based on their heat capacity, density, and compatibility. Then, they were characterized in terms of chemical composition, particle size, and physical properties. The components used for the composites finally selected are wood-cement-wood ash particle boards as well as wood-cementstéatite particle boards. The appropriate formulation for each type of panel was determined in terms of water / cement, wood / cement and adduct / cement mass ratio based on the workability of the paste and the density of the resulting composite material. The composite panels produced were characterized for their mechanical, physical, thermal properties, fire resistance and internal structure characterized by scanning electron microscope. The optimum percentage of replacement of cement by wood ash is 30% by mass. At this amount of replacement, the mechanical properties of the panel have been slightly reduced (12% reduction in flexural strength; 21% reduction in screw pull-out strength) compared to a panel without replacement. Beyond 30% replacement, the properties decreased significantly. Steatite gives us a good panel surface quality, comparable to the surface of gypsum panel standard but without paper. The optimal percentage of replacement of cement by steatite is 15% by mass. Mechanical properties are improved (69% increase in flexural strength, 37% increase in screw pull-out resistance). These panels can be cut easily with a handsaw in the same way as drywall. Therefore, the panel installation process is essentially the same. These panels have good water resistance. Wood-cement-steatite powder panels have better fire resistance than gypsum panels. Indeed, they do not exhibit a visual flame after 20 minutes of exposure to fire (one minute for gypsum board) under a radiative flux of 50 kW/m2 . Their specific heat (15% replacement of cement by steatite) is higher than that of gypsum board by 40%. Gypsum panels and wood-cement-steatite powder panels were installed on the interior walls of experimental huts The results obtained for March and July 2019 show that the heating consumption of the hut with wood- cement-steatite powder panels has decreased by 7% compared to that of the hut with interior gypsum panels when the outside temperature varied from -9°C to 10°C, without internal heating. The interior temperature of the hut with wood-cement-steatite panels is more comfortable on a sunny day. The difference in daily indoor temperature amplitudes between the two huts reached 2.1°C on a very hot day when the outside temperature reached 28°C.
2

Reconstruction 3D d'un bâtiment à partir de photographies prises par un mobile

Butzbach, Thomas 19 April 2018 (has links)
L’Office de l’Efficacité Energétique utilise des méthodes où l’opérateur est très sollicité pour réaliser les modèles 3D de bâtiments nécessaire pour le calcul énergétique. Cependant, les appareils mobiles sont de plus en plus présents sur le marché et pourraient être utilisé pour automatiser cette tâche. Ces appareils possèdent une caméra, et il existe des recherches sur la reconstruction 3D à partir d’images. Ces méthodes permettent d’obtenir un nuage de point et non un maillage devant répondre à certaines caractéristiques afin de pouvoir y réaliser des calculs de volumes. Ce mémoire présente une méthode permettant de réaliser l’acquisition et le traitement qui produit un modèle 3D du bâtiment qui sera utilisé pour les calculs écoénergétiques. Les méthodes de reconstruction 3D ont été passées en revue et ont permis d’imaginer une nouvelle méthode permettant de générer un nuage de points 3D qui sera utilisé pour générer le modèle 3D du bâtiment. / The Office Energy Efficiency use methods to perform 3D model of buildings. But the user is very solicited and he take a lot of time for the 3D reconstruction. The 3D model is using by software for energy calculation. They take some measure to generate an ugly 3D model. Mobile devices are increasingly present on the market at a lower price. These devices contain an integrated camera and there are multiple researches on 3D reconstruction from image. Unfortunately, these methods can generally get a points cloud rather than a mesh that must have some characteristics for accurate volume calculations. The purpose of this paper is to present a series of existing methods or not to perform data acquisition and processing needed to produce a 3D model of a building. The 3D reconstruction methods which we reviewed helped us to designed a new method based on various studies to generate a 3D points cloud. Then an algorithm based on the point cloud processing was performed to generate a 3D model of the building.
3

Simulation et optimisation de l'intégration de matériaux à changement de phase dans une zone thermique

Arnault, Axel 18 April 2018 (has links)
Ce mémoire expose les différentes opportunités d'implantation de matériaux à changement de phase (PCM) dans des zones thermiques intégrées à des bâtiments. Les avantages inhérents à l'emploi de PCM sont analysés dans l'optique de réduction de la consommation d'énergie dans les systèmes CVAC (Chauffage, Ventilation et Air Conditionné). Le travail est divisé en deux parties renvoyant chacune à un article scientifique. Le premier article analyse les impacts et les bénéfices de galvaniser la masse thermique d'une zone en y incluant des PCM. L'étude illustre en premier lieu l'influence prépondérante de l'inertie thermique sur les performances thermiques de la zone, et les possibilités d'optimisation qui en découlent. L'ajout de PCM dans la zone est ensuite formellement optimisé pour deux cas de figure distincts, à savoir l'imposition de conditions climatiques idéalisées ou réelles à la zone. Pour ces deux contextes, on démontre qu'intégrer à la surface de la zone une quantité de PCM correspondant à une fraction de son épaisseur, à une température de fusion d'environ 26°C, augmente significativement les performances de la zone (20% en moyenne). Les calculs sont effectués selon trois fonctions objectives différentes, dont la complexité et la perspective d'optimisation varient. Le chapitre suivant, où le deuxième article est présenté, étend l'analyse décrite ci-dessus à une zone tridimensionnelle. Autrement dit, il est possible d'intégrer du PCM sur le plancher, les murs, le plafond et la façade de la zone à l'étude. Les dimensions, la fenestration, la composition et l'orientation de la zone sont entièrement modulables ; dans le cadre de ce chapitre, l'analyse est restreinte à un cas particulier et démontre que si elle est judicieusement incluse, une faible quantité de PCM peut avoir des retombées énergétiques considérables sur les performances thermiques de la zone. À l'inverse, certaines configurations où l'on inclut du PCM s'avèrent peu performantes et même en deçà des résultats observés sans PCM. Ce travail conjugue une compréhension fondamentale des PCM avec une analyse scientifique rigoureuse, de manière à montrer l'étendue du potentiel de ces matériaux.

Page generated in 0.1221 seconds