Spelling suggestions: "subject:"contraste intravenosa"" "subject:"contraste intravenous""
1 |
Desenvolvimento de novo agente de contraste iodado para nano-sistemas para imageamento por raio-xBitencourt, Júlio Cesar Elói 23 March 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Programa de Pós-Graduação em Biologia Animal, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-05-20T16:15:58Z
No. of bitstreams: 1
2015_JulioCesarEloiBitencourt.pdf: 1806458 bytes, checksum: 0a8d7f915ee4b218ac6e545c68b94610 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-20T16:54:47Z (GMT) No. of bitstreams: 1
2015_JulioCesarEloiBitencourt.pdf: 1806458 bytes, checksum: 0a8d7f915ee4b218ac6e545c68b94610 (MD5) / Made available in DSpace on 2016-05-20T16:54:47Z (GMT). No. of bitstreams: 1
2015_JulioCesarEloiBitencourt.pdf: 1806458 bytes, checksum: 0a8d7f915ee4b218ac6e545c68b94610 (MD5) / Os agentes de contraste iodados atuais causam diversos efeitos adversos e não proporcionam imageamento por período maior que trinta minutos surgindo a necessidade pela busca por agentes de contraste que diminuam os efeitos adversos e propiciem um imageamento de longo prazo. Nesse sentido o desenvolvimento de um agente de contraste iodado nanoestruturado torna-se promissor uma vez que sua estrutura nano traz por si a diminuição dos efeitos adversos e esta permite controlar o tempo que o agente de contraste permanecerá no organismo fornecendo assim um imageamento mais prolongado. O presente estudo desenvolveu uma nova formulação nanoestruturada contendo agentes de contraste iodados para a utilização em raio-x utilizando duas vias de síntese, uma com carreadores nanoestruturado lipídicos, o que posteriormente demonstrou ser inviável, e a utilização das Bases de Schiff, que demonstrou ser promissora. Os carreadores nanoestruturados lipídicos demonstraram a impossibilidade de ligação covalente do iodo ao ácido graxo, fazendo com que o iodo se deslocasse facilmente para o meio, o que é inviável para um agente de contraste. As Bases de Schiff formadas se ligaram covalentemente ao iodo fazendo com que este não fosse para o meio fornecendo a formação de um agente de contraste seguro. Antes da iodação as base de Schiff foram acopladas a moléculas de ácido graxo de sete carbonos para conferir hidrofobicidade, o que é perfeito para formação de nanoemulsão. Logo após a Base de Schiff foi iodada. As estruturas, tanto lipídicas como a Base de Schiff com acoplamento com cadeia de sete carbonos e a estrutura iodada, tiveram suas capacidades de absorção de raio-x medidas no aparelho IVIS® LUMINA XR Series III. A base de Schiff iodada demonstrou uma capacidade de absorção de raio-x de cerca de 2,17 vezes maior que a água demonstrando ser excelente para a finalidade proposta. A base de Schiff iodada com cadeias C7 nanoemulsionada obteve a absorção de raio-x de cerca de 1,22 vezes maior que a água. O acoplamento com cadeias C7 à base de Schiff trouxe a inversão da densidade do óleo fazendo com que esta se tornasse mais pesado que a água provavelmente devido ao alto peso molecular conferido a base de Schiff com o acoplamento. A partir dos resultados obtidos foi observado que a base de Schiff iodada acoplada com cadeias C7 e nanoemulsionada é promissora como agente de contraste necessitando tão somente testes in vivo para completa certificação de um novo tipo de agente de contraste nanoemulsionado no mercado. / Due to the current iodinated contrast agents cause many adverse effects and not offering imaging for a period longer than thirty minutes, there is a need for the search for contrast agents that reduce the adverse effects and conducive to long-term imaging. Therefore the development of a nanostructured iodinated contrast agent becomes promising since their nano structure in itself brings the reduction of adverse effects, and this allows to control the time that the contrast agent remains in the body thereby providing a longer imaging. The objective of this study was to develop a new formulation containing nanostructured iodinated contrast agents for use in computed tomography using two synthetic routes, one with nanostructured lipid carriers, which subsequently proved to be impracticable, and another synthetic route was the use of Schiff Bases which proved to be promising. The Schiff bases had their characteristics evaluated for their preparation, iodination thereof, coupling of carbon chains to give to these lipid solubility and obtaining of X-ray image by IVIS® LUMINA XR Series III machine. The Schiff base iodinated showed an x-ray absorbing capability to approximately 2,17 times greater than the water proving to be excellent for the proposed purpose. The coupling of the C7 chains brought to the Schiff base a density inversion of the oil causing it to become heavier than water probably due to the high molecular weight given to Schiff base with the coupling. This coupled Schiff sample was taken to IVIS® LUMINA XR Series III (28 Kv 100 uA) and had demonstrated its large absorption by x-ray which shows be great for a contrast agent. The Schiff base with iodine and coupling C7 was nanoemulsioned and tested in by IVIS® LUMINA XR Series III (28 Kv 100 uA) and demonstrated x-ray absorption but not as intensely as the Schiff base iodine C7 not nanoemulsioned, probably due to the dilution that the nanoemulsion suffered. From the results obtained it was observed that the Schiff base iodinated coupled with C7 and nanoemulsioned is promising as a contrast agent requiring solely in vivo tests for full certification of a new type of contrast agent in the market nanoemulsioned.
|
2 |
Avaliação da dinâmica normal da circulação do meio de contraste em estruturas vasculares nos exames de tomografia computadorizada das artérias coronáriasMorato, Tiago Nóbrega January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Cristiane Mendes (mcristianem@gmail.com) on 2015-07-07T19:15:02Z
No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-07-08T19:08:55Z (GMT) No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Made available in DSpace on 2015-07-08T19:08:55Z (GMT). No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Introdução: O uso de agentes de contraste intravenoso é corriqueiro em pacientes submetidos à tomografia computadorizada (TC) de tórax. Sabe-se que o tempo de trânsito de contraste (TTC) do sítio de injeção até a circulação sistêmica tem relação com o débito cardíaco e pode trazer importantes informações funcionais, pouco estudadas até o momento. Objetivos: Medir o TTC entre o tronco pulmonar e aorta ascendente em exames de TC de artérias coronárias de pacientes saudáveis, definindo padrões de normalidade para estes tempos de circulação. Métodos: Pacientes ambulatoriais sadios encaminhados para realização de TC de artérias coronárias arrolados de forma consecutiva. Os TTC entre o sítio de injeção e a veia cava superior, tronco pulmonar e aorta ascendente foram medidos com base nas imagens de monitorização (bolus tracking). O débito cardíaco foi calculado a partir das imagens da TC pelo método geométrico e correlacionado com os TTC. Resultados: Foram analisados 18 pacientes. O TTC médio entre a artéria pulmonar e a aorta ascendente foi de 6,8 ± 1,6s. Não houve correlação significativa entre o TTC na circulação pulmonar e o débito cardíaco medido pelo método geométrico. Conclusão: O valor de normalidade do TTC entre a artéria pulmonar e aorta ascendente foi estabelecido, servindo de base para avaliação clínica. / Introduction: The use of contrast agents is a common radiological practice in chest tomography (CT) examinations. It’s known that the transit time of the contrast agent (TTC) between the injection site and the systemic circulation is related to the cardiac output and can add important functional information. Nevertheless, there is little information regarding the normal transit times. Objectives: Measure the TTC between main pulmonary artery and ascending aorta in coronary artery CT’s of healthy patients, defining the normality values for such circulatory times. Methods: Healthy ambulatorial patients who underwent coronary artery CT were included. The TTC’s between the injection site and inferior vena cava, main pulmonary artery and ascending aorta were measured using the bolus tracking images. The cardiac output was measured from the CT images using the geometric method. Results: 18 patients were included in the analysis. The mean TTC between the mean pulmonary artery and aorta was 6,8 ± 1,6s. There was no significant correlation between the TTC and cardiac output measured by the geometric method. Conclusion: The normal value for the TTC between main pulmonary artery and ascending aorta was determined, and can be used as a reference for future publications.
|
Page generated in 0.0854 seconds