Spelling suggestions: "subject:"sense urban context"" "subject:"denna urban context""
1 |
La ventilation naturelle dans la réhabilitation de bâtiments de bureaux en milieu urbain dense : défis et potentiel / Natural Ventilation in office building retrofit in dense urban context : challenges and potential / A ventilação natural na reabilitação de edificios de escritoriós : desafios e potencialidadesRamalho fontenelle, Marilia 30 March 2016 (has links)
À présent, la réhabilitation des bâtiments est entendue comme une opportunité d’adapter les immeubles existants aux transformations urbaines. Ces modifications ont un impact sur la performance environnementale du parc immobilier, et la ventilation naturelle est l’un des aspects les plus affectés. La densification du tissu urbain est responsable, dans certains cas, de la réduction de la vitesse de l’air, qui peut rendre difficile la dissipation de la chaleur, du bruit et des polluants. Sous un climat chaud et humide, ces facteurs provoquent fréquemment l’adoption d’une climatisation mécanique, surtout dans les bâtiments de bureaux. Étant donné l’importance du sujet, ce travail a pour objectif de discuter les défis et le potentiel d’adopter la ventilation naturelle dans les projets de réhabilitation des bâtiments de bureaux en milieu urbain dense. On soutient l’hypothèse que le projet de réhabilitation peut promouvoir l'utilisation efficace de la ventilation naturelle dans les bâtiments de bureaux, à travers son adéquation au contexte urbain et environnemental présent. La demarche adoptée est composée de quatre étapes. Tout d’abord, on effectue une revue de la littérature sur la réhabilitation des bâtiments pour comprendre le contexte spécifique sur lequel on travaille le thème de la «ventilation naturelle». Ensuite, on analyse l’état de l'art sur la ventilation naturelle dans le cadre de la réhabilitation dans les contextes nationaux et internationaux afin d'identifier les avancées atteintes. Après, on réalise une revue de la littérature sur les effets de l'urbanisation sur l’écoulement de l’air. Pour clore, on propose une réhabilitation d’un bâtiment de bureaux dans le centre-ville de Rio de Janeiro, qui permettra de vérifier les bénéfices d’une solution de ventilation pour le confort des occupants. Le travail souligne la complexité de trouver des solutions de réhabilitation qui permettent d’augmenter le débit d’air dans les bâtiments tout en conciliant l’intégralité de leur patrimoine architectural, l’adaptation aux nécéssités présentes et la possibilité des transformations futures. Le défi augmente dans les milieux urbains denses, où le bruit, la pollution de l’air et la faible perméabilité du tissu urbain peuvent poser des limitations. Dans le cadre des recherches en Europe, Asie et Amérique du Nord, plusieurs réhabilitations ont été réalisées pour analyser la performance des solutions de ventilation. Les ventilations hybride et nocturne sont les plus indiquées. Au Brésil, les recherches sur ce sujet restent balbutiantes et la climatisation mécanique est la solution 9 prédominante dans les rénovations des espaces corporatifs. L’étude de cas montre, à l’aide des modélisations CFD, que la densification de la région analysée a réduit la vitesse et le débit d’air des étages et, par conséquent, a diminué les heures de confort thermique. Les étages plus bas sont les moins favorisés par le vent et le bruit. Ce diagnostic montre la nécessité d’amplifier le débit d’air du bâtiment pendant son occupation et de rendre possible la ventilation nocturne pour dissiper la chaleur accumulée pendant la journée. Dans ce sens, on propose l’ouverture de la partie fixe supérieure de toutes les fênetres, une intervention qui préserve les caractéristiques originales des façades et ne nuit pas à la sécurité du bâtiment lorsqu’il est inoccupé. Les résultats indiquent que cette intervention a augmenté les heures de confort thermique des occupants entre 0,5 et 35%, selon l’étage et de l’indicateur utilisé dans l’interprétation des résultats. Cela renforce l’hypothèse que la ventilation naturelle, toute seule, n’est pas sufisante pour préserver le confort des occupants pendant toute l’année. Cependant, elle peut être complétée par la ventilation mécanique, a fin de concilier le bien-être des usagers et la réduction de la consommation d’énergie des bâtiments / Nowadays, retrofitting is understood as an opportunity to adapt existing buildings to the urban transformations of its surroundings. The changes in the urban fabric can cause impacts to the building environmental performance and, generally, natural ventilation is one of the most affected aspects. The densification process is responsible, in some cases, for the reduction of wind speed, which can disturb the dissipation of heat, noise and pollutants. In hot and humid climate, these factors cause frequently the adoption of mechanical ventilation, mainly in office buildings. Given the relevance of the subject, this work aims to discuss the challenges and potential of adopting natural ventilation in the retrofit of office buildings located in dense urban areas. Our hypothesis is that the retrofit project can promote the efficient use of natural ventilation in office buildings, through its adaptation to the present urban and environmental conditions. The methodology includes 4 stages. First, we carry out a literature review about building retrofits to understand the specific context with which we are dealing the subject of “natural ventilation”. Next, we analyze the state of the art of natural ventilation in the retrofit context to identify the main findings. Then, we investigate the effects of urbanization on the airflow pattern. Finally, we propose retrofitting an office building in downtown Rio de Janeiro to verify the benefits offered by a ventilation solution to the occupants’ thermal comfort. We highlight the complexity of developing solutions that increase the airflow in buildings while balancing the protection of its past, the response to the present requirements and the possibility of future changes. This challenge increases in dense urban areas, where noise, air pollution and low permeability of the urban fabric can place some limitations. As part of the research carried out by European, Asian and North American countries, several renovations were conducted to analyze the performance of ventilation solutions. Hybrid and night ventilation were indicated as the most appropriate ones. In Brazil, investigations in this subject remain incipient and air conditioning is the predominant solution in office spaces. By means of CFD simulations, the case study shows that the densification of the analyzed region reduced the wind speed and airflow in all floors and, therefore, reduced the thermal comfort hours. The lower floors are the least favored by the wind and the noise. This diagnostic points out the need to increase buildings airflow during its occupancy and allow night ventilation to dissipate the heat gains accumulated during the day. In this way, we propose to open the upper fixed 11 portion of all windows, a solution that protects the original façade features and do not harm the buildings security when it is not occupied. Thermal simulations indicate that this procedure increases the thermal comfort annual hours in 0,5-35%, depending on the floor and the adaptive comfort model used to interpret the results. We conclude that natural ventilation itself is not sufficient to ensure occupants comfort throughout the year, however it can be complemented by mechanical ventilation in order to balance thermal comfort and energy efficiency. / Atualmente, a reabilitação é entendida como uma oportunidade de adaptar os edifícios existentes às transformações urbanas sofridas pelo entorno. Tais modificações geram impactos ao desempenho ambiental do imóvel, e a ventilação natural é um dos aspectos mais afetados. O adensamento do tecido urbano é responsável, em alguns casos, pela redução da velocidade do ar, que pode dificultar a dissipação do calor, ruído e poluentes. Nos climas quentes e úmidos, esses fatores provocam frequentemente a adoção de refrigeração mecânica, especialmente em edifícios de escritórios. Dada a relevância do tema, este trabalho tem por objetivo discutir os desafios e potencialidades de adotar a ventilação natural no projeto de reabilitação de edifícios de escritórios situados em meios urbanos densos. Assume-se como hipótese que o projeto de reabilitação pode promover uma utilização eficiente da ventilação natural nos edifícios de escritórios, por meio de sua adequação ao contexto urbano presente. A metodologia adotada é composta por quatro etapas. Inicialmente, realiza-se uma revisão bibliográfica sobre a reabilitação de edifícios a fim de compreender o contexto específico sobre o qual será trabalhado o tema da ventilação natural. Em seguida, analisa-se o estado-da-arte da ventilação natural no contexto da reabilitação, buscando identificar os principais avanços obtidos no cenário nacional e internacional. Depois, efetua-se uma revisão da literatura sobre os efeitos da urbanização no escoamento do ar. Finalmente, propõe-se uma reabilitação de um edifício de escritórios no centro do Rio de Janeiro, para verificar os benefícios de uma solução de ventilação no conforto dos ocupantes. O trabalho destaca a complexidade de desenvolver soluções reversíveis que possibilitem aumentar a vazão de ar nos edifícios e preservar suas características construtivas. O desafio é ainda maior em meios urbanos densos, onde o ruído, a poluição do ar e a baixa permeabilidade do tecido urbano podem impor limitações. As pesquisas desenvolvidas na Europa, Ásia e América do Norte destacam as ventilações híbrida e noturna como as soluções mais indicadas. No Brasil, os trabalhos sobre o tema ainda são incipientes, e a refrigeração mecânica é a solução predominante nas reabilitações de espaços corporativos. O estudo de caso indica, por meio de simulações fluidodinâmicas e térmicas, que a densificação da área analisada reduziu a velocidade e vazão do ar no edifício, diminuindo as horas de conforto térmico. Os pavimentos7mais baixos são os menos favorecidos pelos ventos e ruído. Este diagnóstico indica a necessidade de aumentar a vazão de ar durante a ocupação e viabilizar a ventilação noturna para dissipar o calor acumulado durante o expediente. Neste sentido, propõe-se a abertura das folhas fixas sobre as janelas existentes, o que não compromete a preservação das características originais das fachadas e a segurança do edifício quando desocupado. Os resultados indicam que esta intervenção aumenta entre 0,5 e 35% as horas de conforto dos ocupantes. Conclui-se que a ventilação natural, por si só, não satisfaz o conforto térmico durante o ano todo, mas pode ser complementada pela ventilação mecânica, de modo a conciliar eficiência energética e bem-estar dos usuários.
|
Page generated in 0.0969 seconds