Spelling suggestions: "subject:"den."" "subject:"det.""
71 |
An?lise fotoel?stica da influ?ncia da aplica??o de carga no padr?o de distribui??o de tens?es em implantes dent?riosBarbieri, Guilherme Machado 17 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:24Z (GMT). No. of bitstreams: 1
448372.pdf: 1689966 bytes, checksum: 48a67133718d201e5dec9cece771f87c (MD5)
Previous issue date: 2013-01-17 / The aim of this study was to evaluate and compare stress distribution around implants using platform switching technique with conventional diameters, using the photoelasticity method in internal and external hex-type implants. Five models were fabricated using photoelastic resin kit FLEXIBLE G3 (POLIPOX Ind. E Com, Sao Paulo Brazil) with a single-body implant in each of them. These models were as follows: MODEL A - 4.1mm platform with 4.1mm external hex implant-abutment connection; MODEL B - 5.0mm platform with 4.1mm external hex implant-abutment connection; MODEL C - 5.0mm platform with 5.0-mm external hex implant-abutment connection; MODEL D - 4.5mm platform with 4.5mm internal hex implant-abutment connection; and MODEL E - 4.5mm platform 3.8mm internal hex implant-abutment connection. An axial load of 100N was applied in a plane polariscope to verify isochromatic fringes. The images were photographed with a digital camera CANON EOS DIGITAL REBEL XTI and viewed with software specially developed for this study. The values for total maximum shear stress for implant HISW was 20.16 kPa, HI 20.64 kPa, 21.84 kPa HESW, HE 21.70 kPa and 20.74 kPa for control implant. The internal hex implant showed better load distribution and lower stress values when the platform switching technique was used and no system was able to eliminate stress on some thirds. / O objetivo deste estudo foi avaliar e comparar a distribui??o de tens?es de implantes utilizando a t?cnica da plataforma switching com os di?metros convencionais, atrav?s do m?todo da fotoelasticidade, em implantes do tipo hex?gono externo e hex?gono interno. Cinco modelos foram constru?dos com a resina fotoel?stica KIT FLEX?VEL G3 (POLIPOX Ind. E Com., S?o Paulo Brasil), com um implante unit?rio em cada um deles. Estes modelos foram MODELO A plataforma de 4.1mm HE/pilar de 4.1mm, MODELO B plataforma de 5.0mm HE/pilar de 4.1mm, MODELO C plataforma de 5.0mm HE/ pilar de 5.0mm, MODELO D plataforma de 4.5mm HI/pilar de 4.5mm e MODELO E plataforma de 4.5mm HI/pilar de 3.8mm. Uma carga axial de 100N foi aplicada em um polarisc?pio plano para a verifica??o da franjas isocrom?ticas. As imagens foram fotografadas com uma c?mera digital CANON EOS DIGITAL REBEL XTI e visualizadas com o software especialmente desenvolvido para este trabalho. Os valores de tens?o m?xima cisalhante total para o implante HISW foi de 20,16KPa, HI 20,64KPa, HESW 21,84KPa, HE 21,70KPa e para o implante controle 20,74KPa. O implante de hex?gono interno apresentou uma melhor distribui??o de carga e menores valores de tens?o com a utiliza??o da t?cnica plataforma switching, sendo que nenhum sistema foi capaz de eliminar tens?o em algum dos ter?os.
|
72 |
Avalia??o quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanoparticulas submetidas a diferentes m?todos de polimentoCosta, Catharina Simoni da 23 September 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:29Z (GMT). No. of bitstreams: 1
452168.pdf: 1481490 bytes, checksum: ac569335421ad138a02a15752e11a756 (MD5)
Previous issue date: 2013-09-23 / Introduction : There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles.
Objective : To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles.
Materials and methods : The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanoh?brid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM.
Statistical analyses : For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%.
Results : The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins.
Conclusion : Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group. / Introdu??o : Existe no mercado odontol?gico muitos instrumentos rotat?rios para serem utilizados no polimento final de uma restaura??o adesiva. Como s?o muitas as op??es, e um mesmo fabricante tem mais de um tipo de instrumento rotat?rio para realizar a finaliza??o da restaura??o, n?o se estabelece uma conduta ?nica que determine qual o instrumento utilizar para resinas compostas que contenham nanopart?culas. Objetivo : Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superf?cie de duas resinas com nanopart?culas. Materiais e m?todos : As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanoh?brida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cil?ndricos medindo 3 mm X 6 mm. Um ?nico operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seq??ncia Laranja fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seq??ncia Laranja fina e superfina ). A rugosidade de superf?cie foi avaliada com rugos?metro (Ra), MEV e AFM. Estat?stica : Para an?lise das m?dias de rugosidade Ra (μm), os dados foram submetidos aos testes de normalidade de ANOVA, ao n?vel de signific?ncia de 5%. Uma vez verificada a distribui??o normal dos resultados, estes foram submetidos ? an?lise de vari?ncia, seguida pelo teste de Tukey com n?vel de signific?ncia de 5%. Resultados : As an?lises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex n?o mostrou diferen?a estat?stica entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferen?a estat?stica entre as resinas. Conclus?o : Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex n?o mostrou diferen?as estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superf?cie obtida foi pelo grupo controle.
|
73 |
Resist?ncia ? fratura de dentes com preparos cavit?rios MOD restaurados com resina composta e fibra de vidroRodrigues, Fausto Borges 19 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:41Z (GMT). No. of bitstreams: 1
392253.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5)
Previous issue date: 2007-01-19 / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma tran?ada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resist?ncia ? fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares h?gidos foram selecionados e montados em blocos acr?licos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se h?gidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavit?rios MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endod?nticos. Ap?s o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma tran?ada e outra unidirecional, respectivamente. Ap?s, os corpos de prova foram submetidos ao ensaio de resist?ncia ? fratura. Avaliou-se, tamb?m, qualitativamente as falhas classificando-as em fratura de c?spide, assoalho e c?spide mais assoalho, ap?s o ensaio mec?nico. Os resultados (N) obtidos foram (m?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utiliza??o de fibras tran?adas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endod?ntico n?o melhora a resist?ncia a compress?o apresentando um padr?o de fratura de assoalho mais c?spide n?o favor?vel ? recupera??o da pe?a dent?ria
|
74 |
Fatores biomec?nicos e complica??es prot?ticas : estudo prospectivo em pr?teses totais fixas implantossuportadasColtro, Maria Paula de Lima 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-06-03T16:59:51Z
No. of bitstreams: 1
DIS_MARIA_PAULA_DE_LIMA_COLTRO_COMPLETO.pdf: 1389678 bytes, checksum: 5d99119d56b120f8f2e7274e03a651bb (MD5) / Made available in DSpace on 2016-06-03T16:59:51Z (GMT). No. of bitstreams: 1
DIS_MARIA_PAULA_DE_LIMA_COLTRO_COMPLETO.pdf: 1389678 bytes, checksum: 5d99119d56b120f8f2e7274e03a651bb (MD5)
Previous issue date: 2016-02-29 / Failures in implant supported fixed complete dentures may be related to the biomechanical factors and structural quality of the prostheses. The aim of this prospective cohort study was to investigate the influence of the biomechanical and clinical factors on failures and complications observed in implant supported fixed complete dentures. The data were collected at baseline and 6, 12, 24 and 36 months after delivery of the definitive prostheses through anamneses, physical examination and measurements of maximal bite force, presence and intensity of the bruxism, quality of life (OHIP-14), distribution of the occlusal contacts and technical quality of the metallic framework. Statistical analysis was performed using the Kaplan-Meier survival analysis, multivariate analysis by a Cox regression model and a paired t-test. The convenience sample consisted of 69 patients rehabilitated with 72 fixed complete dentures with up to 47 months of follow-up. Thirteen fixed complete dentures failed (18%), occurring avulsion or fracture of the artificial denture teeth. The main results were; 1) high success index of the treatment with 100% implant survival rate in 36 months and occurrence of 18% of repairable failures in prostheses. 2) presence of bruxism or high maximal bite force do not negatively influence the occurrence of the failures. 3) the design of the metallic framework (insufficient height of the retentive pins) is the risk factor for the failures. No association was found between failures and gender, body mass index, thickness of the aesthetic coating, type of the antagonist arch or superior/inferior arch. The results suggest that a better standardization of metal framework construction is necessary, because insufficient height of the retentive pins of the denture teeth was the main factor related to the failures in evaluated prostheses. It is possible to control this factor in the laboratory and in the clinic to reduce the risk of failure and increase the longevity of the prostheses. Moreover, occlusal adjustments should be carefully observed, because the failures appear to occur more on the overloaded segment of the arch. / Falhas em pr?teses totais fixas implantossuportadas (PTFIs) podem estar relacionadas com fatores biomec?nicos e com a qualidade estrutural das pr?teses. O objetivo deste estudo de coorte prospectivo foi avaliar a influ?ncia de fatores biomec?nicos e cl?nicos em falhas e complica??es de PTFIs. Os dados foram coletados desde o momento da prova da infraestrutura met?lica e aos 6, 12, 24 e 36 meses ap?s a instala??o da pr?tese, atrav?s de anamnese, exame f?sico e medi??es de for?a m?xima de mordida, presen?a e intensidade de bruxismo, qualidade de vida (OHIP-14), distribui??o dos contatos oclusais e avalia??o do desenho da infraestrutura met?lica. A an?lise estat?stica foi realizada de forma descritiva, por an?lise de sobrevida pelo m?todo de Kaplan-Meier, an?lise multivariada atrav?s da regress?o de Cox e teste-t pareado. A amostra de conveni?ncia foi constitu?da por 69 pacientes que receberam 72 PTFIs em maxila e mand?bula e foram acompanhados por um per?odo de at? 47 meses (m?dia de 23,1 meses). Treze PTFIs falharam (18%), ocorrendo avuls?o ou fratura da faceta dent?ria acr?lica. Os principais resultados foram: 1) alto ?ndice de sucesso do tratamento com ocorr?ncia de 18% de falhas recuper?veis nas pr?teses e sobrevida de 100% dos implantes em 36 meses; 2) n?o houve influ?ncia negativa de bruxismo ou de for?a de mordida elevada na ocorr?ncia de falhas; 3) o desenho da infraestrutura met?lica (reten??es - altura inadequada dos pinos) foi o principal fator de risco para falhas. N?o houve rela??o de falhas com sexo, ?ndice de massa corporal, espessura de revestimento est?tico, tipo de arco antagonista ou arcada superior/inferior. Os resultados sugerem que h? necessidade de uma maior padroniza??o na confec??o das infraestruturas met?licas, pois a altura inadequada dos pinos para reten??o das facetas dent?rias foi o principal achado relacionado ?s falhas nas pr?teses avaliadas. Este fator ? pass?vel de ser controlado no laborat?rio e na cl?nica, possibilitando interven??o profissional para redu??o de risco de falha e aumento da longevidade da pr?tese. Al?m disso, o ajuste oclusal deve ser observado, pois as falhas nas PTFIs parecem ocorrer mais frequentemente no lado mais sobrecarregado da arcada.
|
75 |
Avalia??o in vitro do efeito de agentes clareadores externos em substrato dental bovino e humanoFracasso, Lisiane Martins 15 April 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-23T16:28:24Z
No. of bitstreams: 1
TES_LISIANE_MARTINS_FRACASSO_COMPLETO.pdf: 2024723 bytes, checksum: 86eb1d075734ce517445de104dfe5025 (MD5) / Made available in DSpace on 2016-08-23T16:28:24Z (GMT). No. of bitstreams: 1
TES_LISIANE_MARTINS_FRACASSO_COMPLETO.pdf: 2024723 bytes, checksum: 86eb1d075734ce517445de104dfe5025 (MD5)
Previous issue date: 2016-04-15 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of this study was to evaluate the effect of external bleaching agents in bovine and human dental enamel. There were evaluated different products commercially available for performing tooth whitening: whitening toothpastes and carbamide peroxide gels and hydrogen used in at-home technique, supervised by the dentist. The action of the dental bleaching creams was evaluated in two different substrates: human and bovine dental enamel. Due to differences in application protocols of bleaching products and methodologies of the studies, these were divided into three chapters: Chapter 1: Article 1: Effect of different whitening toothpastes on the roughness and surface topography of dental enamel. Chapter 2: Article 2: Effect of different whitening toothpastes on the roughness and surface topography of human tooth enamel. Chapter 3: Article 3: Analysis of color change, surface roughness and topography of bovine dental enamel submitted to different home bleaching agents. / O objetivo geral deste estudo foi avaliar o efeito de agentes clareadores externos em esmalte dental bovino e humano. Foram avaliados diferentes produtos dispon?veis comercialmente para realiza??o de clareamento dent?rio: cremes dentais clareadores e g?is de per?xido de carbamida e hidrog?nio utilizados na t?cnica caseira, supervisionada pelo cirurgi?o-dentista. A a??o dos cremes dentais clareadores foi avaliada em dois diferentes substratos: esmalte dental humano e bovino. Devido ?s diferen?as nos protocolos de aplica??o dos produtos clareadores e nas metodologias dos estudos, estes foram divididos em tr?s cap?tulos: Cap?tulo 1: Artigo 1: Avalia??o do efeito de diferentes cremes dentais clareadores na rugosidade e topografia superficial de esmalte dent?rio bovino. Cap?tulo 2: Artigo 2: Avalia??o do efeito de diferentes cremes dentais clareadores na rugosidade e topografia superficial de esmalte dent?rio humano. Cap?tulo 3: Artigo 3: An?lise da altera??o de cor, rugosidade e topografia superficial de esmalte dent?rio bovino submetido a diferentes agentes clareadores caseiros.
|
76 |
Influ?ncia da t?cnica de fabrica??o e dos materiais sobre o ajuste da interface pilar/implante em infraestruturas implantossuportadasFranca, Danilo Gonzaga Bernardo de 22 March 2013 (has links)
Made available in DSpace on 2014-12-17T15:43:52Z (GMT). No. of bitstreams: 1
DaniloGBF_DISSERT.pdf: 1485726 bytes, checksum: 4640fbe2db551567fc003e0585ff8950 (MD5)
Previous issue date: 2013-03-22 / The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Br?nemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ? 3.6, 107.2 ? 36), CoCrcad (1.2 ? 2.2, 107.5 ? 26 ), CoCrUCci (11.8 ? 9.8, 124.7 ? 74), CoCrUCc (12.9 ? 11.0, 108.8 ? 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology / O objetivo deste estudo foi comparar o desajuste vertical, horizontal e a passividade de infraestruturas fabricadas em zirc?nia e cobalto-cromo por tecnologia CAD/CAM e pelo m?todo da fundi??o convencional. Dezesseis infraestruturas em monobloco, foram obtidas a partir de uma matriz met?lica contendo tr?s implantes Br?nemark compat?veis de plataforma regular (Titamax Cortical Ti, Neodent). Oito infraestruturas foram confeccionadas pelo sistema CAD/CAM (NeoShape, Neodent): quatro em zirc?nia (Zircad) e quatro em cobalto-cromo (CoCrcad). Outras oito infraestruturas foram obtidas pelo m?todo da fundi??o convencional: quatro em cobalto-cromo com pilar UCLA cinta Co-Cr (CoCrUCci) e quatro em cobalto-cromo com pilar UCLA calcin?vel (CoCrUCc). O ajuste vertical, horizontal e a passividade pelo teste do parafuso ?nico foram mensurados usando microscopia eletr?nica de varredura com aumento de 250x. Inicialmente avaliou-se a passividade pelo teste do parafuso ?nico e posteriormente para avaliar o desajuste vertical e horizontal, apertou-se todos os parafusos, com torque de 20Ncm. M?dia, desvio padr?o, valor m?nimo e m?ximo foram calculados para cada grupo. As medidas de desajuste horizontal foram transformadas em frequ?ncia cumulativa para categoriza??o da vari?vel e posterior compara??o grupos a grupo. Para avaliar a exist?ncia de diferen?as quantitativas entre os grupos testados para desajuste vertical e passividade, foi usado o teste Kruskal-Wallis. O teste Mann-Whitney foi usado para comparar as diferen?as estat?sticas grupo a grupo (p<0,05). Foram observados os respectivos valores de m?dia e desvio padr?o em micr?metros para desajuste vertical e passividade: Zircad (5,9 ? 3,6; 107,2? 36), CoCrcad (1,2 ? 2,2; 107,5? 26), CoCrUCci (11,8 ? 9,8; 124,7? 74), CoCrUCc (12,9 ? 11,0; 108,8? 85). Observaram-se diferen?as estat?sticas para medidas de desajuste vertical (p=0,000). O teste Mann-Whitney revelou diferen?as estat?sticas (p<0,05) entre todos os grupos, exceto entre CoCrUCci e CoCrUCc (p=0,619). Nenhuma diferen?a estat?stica foi observada para a passividade das infraestruturas. Em rela??o ao desajuste horizontal, os grupos ZirCAD e CoCrcad n?o apresentaram melhores valores em rela??o a CoCrUCci e CoCrUCc. Baseado nos resultados pode-se concluir que infraestruturas confeccionadas por tecnologia CAD/CAM obtiveram melhores valores de ajuste vertical que aquelas fabricadas pelo m?todo da fundi??o, apesar disso, a passividade das infraestruturas n?o foi influenciada pela t?cnica de fabrica??o e material utilizado. O ajuste horizontal obtido pelas infraestruturas fabricadas por CAD/CAM n?o foi superior ?quelas fabricadas por fundi??o. Uma menor variabilidade no ajuste vertical e na passividade foi observada quando infraestruturas foram fabricadas por tecnologia CAD/CAM
|
77 |
Poly(L-lactic acid) membranes : abscense of genotoxic hazard and potential for drug deliveryUzun Junior, Nelson 25 June 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2017-03-13T16:56:33Z
No. of bitstreams: 1
TES_NELSON_UZUN_JUNIOR_PARCIAL.pdf: 860913 bytes, checksum: 8b7a423424bb4dfd9536bbf025f546c9 (MD5) / Made available in DSpace on 2017-03-13T16:56:33Z (GMT). No. of bitstreams: 1
TES_NELSON_UZUN_JUNIOR_PARCIAL.pdf: 860913 bytes, checksum: 8b7a423424bb4dfd9536bbf025f546c9 (MD5)
Previous issue date: 2015-06-25 / Biomaterial is defined as any substance from natural sources or synthetic, that can be used in biological tissues without causing deleterious reactions to the body. Widely used for more than four decades, the titanium has an important role in various areas of health. Its use cannot be considered completely safe. The literature reports the presence of atrophy or bone deformation when this material is used for the treatment of fractures or rehabilitation in young patients, in addition to interfering in some imaging tests and uncomfortable to touch. The absorbable polymers, in particular the PLA, are materials with the advantage of being completely absorbed by the body. Although the use of PLA as material for bone synthesis is known, research with the purpose of better understanding the behavior of this polymer front to biological tissue are necessary, because it has different physical and chemical characteristics of titanium, so that you can offer advantages in relation to the metal. These in vitro studies evaluated the behavior of titanium and the PLA at the cellular level and molecular. No cytotoxic effect or genotoxic was observed in the tests with the cells 3T3 and CHO-K1. In addition to replication and gene expression remained unchanged in both experiments with titanium as with the PLA. The latter also showed the ability to incorporate and release molecules. / Define-se biomaterial como qualquer subst?ncia proveniente de fontes naturais ou sint?ticas, que possam ser utilizados nos tecidos biol?gicos sem provocar rea??es delet?rias ao sistema. Amplamente utilizado a mais de quatro d?cadas, o tit?nio tem um papel importante nas diversas ?reas da sa?de. Ainda assim seu uso n?o pode ser considerado completamente seguro. A literatura relata a presen?a de atrofia ou deforma??o ?ssea quando este material ? utilizado para o tratamento de fraturas ou reabilita??es em pacientes jovens, al?m de interferir em alguns exames de imagem e apresentar desconforto ao toque. Os pol?meros absorv?veis, em particular o PLA, s?o materiais com a vantagem de ser completamente absorvidos pelo organismo. Embora o uso do PLA como material para s?ntese ?ssea seja conhecido, pesquisas com a finalidade de compreender melhor o comportamento deste pol?mero frente aos tecido biol?gicos s?o necess?rias, pois ele apresenta caracter?sticas f?sicas e qu?micas diferentes do tit?nio, de forma que pode oferecer vantagens em rela??o ao metal. Estes estudos in vitro avaliaram o comportamento do tit?nio e do PLA em n?vel celular e molecular. Nenhum efeito citot?xico ou genot?xico foi observado nos ensaios realizados com as c?lulas 3T3 e CHO-K1. Al?m disso a replica??o e a express?o g?nica se mantiveram inalteradas tanto nos experimentos realizados com o tit?nio como com o PLA. Este ?ltimo ainda mostrou a capacidade de incorporar e liberar mol?culas.
|
78 |
Avalia??o in vitro da citotoxicidade do formocresol, do tricresol formalina e do formalde?do em tr?s diferentes linhagens celularesThomas, Melissa Isabel 28 June 2006 (has links)
Made available in DSpace on 2015-04-14T14:51:37Z (GMT). No. of bitstreams: 1
383071.pdf: 1037097 bytes, checksum: 64845ab6c2bfb968dc78afc6dab91fc8 (MD5)
Previous issue date: 2006-06-28 / A avalia??o da citotoxicidade dos materiais dentais ? de grande import?ncia na Odontologia. O formocresol (FC) e o tricresol formalina (TC) s?o duas medica??es utilizadas na odontologia para desinfec??o do canal radicular, que cont?m formalde?do na sua formula??o. Estes produtos s?o considerados bons antimicrobianos, mas pesquisas a respeito da toxicidade destes medicamentos ainda s?o necess?rias. O presente estudo avaliou in vitro a citotoxicidade do formalde?do, do FC e do TC, utilizando tr?s linhagens celulares estabelecidas, as c?lulas HeLa, NIH3T3 e Hep2, cultivadas em condi??es padr?o. As c?lulas foram deixadas em contato com cada produto durante 1, 2, 3, 4 ou 5 minutos, sendo ent?o incubadas por 24 horas, 48 horas ou 7 dias. O teste de citotoxicidade utilizado foi o ensaio MTT. Os resultados deste estudo mostraram que os produtos testados foram t?xicos ?s diferentes linhagens celulares estabelecidas, em todas as condi??es testadas. O formocresol foi o produto que apresentou menor citotoxicidade, sendo este resultado estatisticamente significante quando comparado com o tricresol formalina e o formalde?do.
|
79 |
Toxicidade da solda de prata utilizada em ortodontia : estudo "in vitro" e "in situ"Freitas, Maria Perp?tua Mota 15 May 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:19Z (GMT). No. of bitstreams: 1
402872.pdf: 99141 bytes, checksum: 5dc4125b2c78cb76226d6ed213f92959 (MD5)
Previous issue date: 2008-05-15 / Prop?s-se neste trabalho avaliar a toxicidade da solda de prata utilizada em Ortodontia por meio do teste de citotoxicidade "in vitro", bem como pela determina??o "in situ" da concentra??o dos ?ons componentes da solda de prata, liberados na saliva humana. O ensaio de citotoxicidade foi por meio de cultura de fibroblastos, linhagem NIH/3T3, sendo montados 4 grupos (n=10, cada): controle, controle negativo (fio de a?o inoxid?vel), controle positivo (discos de am?lgama) e (solda de prata). Ap?s o cultivo das c?lulas em meio D-MEM completo e obtida conflu?ncia de 80%, a suspens?o foi adicionada sobre as placas de 24 po?os, contendo os corpos de prova, sendo incubados em estufa a 37?C, por 24 horas. Ap?s esse per?odo, as placas foram avaliadas em microsc?pio ?ptico invertido, fotomicrografadas e os resultados registrados em ?ndices de resposta, a partir de modifica??es nos par?metros de Stanford (1980), baseados no tamanho do halo de difus?o da subst?ncia t?xica e quantidade de lise das c?lulas. Os resultados mostraram ?ndice de resposta m?ximo para o grupo da solda de prata, bem como severa inibi??o da prolifera??o e crescimento celular, c?lulas mais circulares e, em grande parte, com aspecto escurecido e granular, sugerindo lise com morte celular, resultados compar?veis ao controle positivo. No estudo "in situ", a amostra foi composta por 60 indiv?duos entre 8 e 14 anos, divididos em 2 grupos (n=30, cada): controle e teste (necessidade de uso do aparelho de Hyrax). Para an?lise da libera??o dos ?ons met?licos, foram coletadas amostras da saliva de cada paciente, em 6 tempos, para ambos os grupos: inicial, 10 minutos, 24 horas, 7, 30 e 60 dias p?s-instala??o do aparelho. A avalia??o da saliva foi realizada por meio de Espectrofotometria de Absor??o At?mica com Forno de Grafite, determinando-se a concentra??o dos ?ons c?dmio, cobre, zinco e prata. Para an?lise estat?stica, foram utilizados os testes n?o-param?tricos de Friedman e Mann-Whitney, com p<0,05. As concentra??es i?nicas, no grupo controle, mostraram valores baixos para o c?dmio, cobre, zinco (p>0,05) e, principalmente para a prata, onde n?o atingiram limite de detec??o. No grupo teste, todos os ?ons mostraram concentra??es expressivas aos 10 minutos p?s- instala??o do aparelho (p<0,01), maiores m?dias para o cobre, com tend?ncia ? redu??o ap?s 24 horas. A compara??o entre os grupos mostrou diferen?as significativas para o cobre (todos os tempos), zinco (10 minutos, 24 horas, 7 e 30 dias) e, para o c?dmio, apenas aos 10 minutos. Concluiu-se que a solda de prata representa um material de alta toxicidade para as c?lulas estudadas; as diferen?as nas concentra??es i?nicas intragrupos e intergrupos mostraram, nitidamente, a influ?ncia das caracter?sticas fisiol?gicas e metab?licas individuais da cavidade oral humana sobre as ligas utilizadas nos aparelhos ortod?nticos e processo corrosivo desencadeado, assim como foi percept?vel a grande libera??o dos ?ons, com concentra??es elevadas imediatamente ap?s a instala??o do aparelho, representando risco de absor??o e reten??o desses ?ons pelo organismo humano, apesar da regress?o nas concentra??es, ainda no per?odo estudado.
|
80 |
Torque de remo??o de implantes lisos e texturizados com e sem estabilidade prim?ria associados ou n?o ao plasma rico em plaquetasSuzuki, Roberto Makoto 21 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:21Z (GMT). No. of bitstreams: 1
399345.pdf: 1607663 bytes, checksum: 3e900d3262bbff08d819d4414119f515 (MD5)
Previous issue date: 2006-12-21 / O objetivo desse estudo foi avaliar o torque de remo??o de implantes lisos e texturizados sem estabilidade prim?ria associados a plasma rico em plaquetas. Foi utilizado um total de sete coelhos f?meas, brancas da ra?a Nova Zel?ndia Branco (Oryctolagos cuniculus l.). Em cada coelho foram instalados 6 implantes, 3 para cada t?bia, de acordo com os seguintes grupos experimentais: 1- implante liso com estabilidade prim?ria e sem PRP (plasma rico em plaquetas); 2- implante liso sem estabilidade prim?ria e sem PRP; 3- implante liso sem estabilidade prim?ria e com PRP; 4- implante texturizado com estabilidade prim?ria e sem PRP; 5- implante texturizado sem estabilidade prim?ria e sem PRP; 6- implante texturizado sem estabilidade prim?ria e com PRP. Os protocolos cir?rgicos foram aplicados de acordo com cada grupo experimental e ap?s um per?odo de 9 semanas, os animais foram mortos. Logo ap?s a morte dos animais, a mensura??o do torque de remo??o foi realizada. As m?dias dos grupos foram: grupo 1, 53,01 Ncm (?9,68); grupo 2, 45,29 Ncm (?16, 90); grupo 3, 43,43 Ncm (?16,70); grupo 4, 56,60 Ncm (?16,00); grupo 5, 46,89 Ncm (?15,60) e grupo 6, 48,49 Ncm (?17,06). Os dados foram analisados atrav?s da An?lise de Vari?ncia M?ltipla, utilizando o delineamento em blocos casualizados que demonstrou n?o haver diferen?a estat?stica entre os grupos ao n?vel de 5% nas condi??es experimentais estabelecidas. As distintas condi??es experimentais n?o foram capazes de promover diferen?a no torque de remo??o.
|
Page generated in 0.0462 seconds