• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 283
  • 15
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • Tagged with
  • 300
  • 124
  • 70
  • 60
  • 59
  • 53
  • 42
  • 37
  • 36
  • 35
  • 34
  • 34
  • 34
  • 29
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

A biochemical study of human tooth pulp response to caries

Le Bell, Yrsa. January 1980 (has links)
Thesis (doctoral)--University of Turku, 1980. / Includes 6 separately published papers in support of the thesis. "Also published in Proceedings of the Finnish Dental Society, vol. 76, suppl. 1." Includes bibliographies.
162

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro

Lopes, José Fernando Scarelli [UNESP] 17 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-17Bitstream added on 2014-06-13T18:58:07Z : No. of bitstreams: 1 lopes_jfs_me_arafo.pdf: 1497511 bytes, checksum: 5cff0da20eacc454b65a7066c2aba9f6 (MD5) / O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de... / The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below)
163

Desenvolvimento de um paralelizador intra-oral e verificação de sua precisão como método de transferência de planos de guia: Estudo laboratorial

Borges, Alexandre Luiz Souto [UNESP] 25 June 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-06-25Bitstream added on 2014-06-13T20:18:34Z : No. of bitstreams: 1 borges_als_me_sjc.pdf: 930416 bytes, checksum: 633f72e6bd06c491501fafc4e1e20ee9 (MD5) / O objetivo do presente estudo foi desenvolver um aparelho intra-oral (ParalAB) e verificar sua efetividade como um método de transferência de planos de guia, comparando-o com o delineador de bancada. Foram empregados trinta modelos de gesso, divididos em dois grupos (n=15): no grupo 1 foram preparados planos de guia com delineador de bancada e no grupo 2, com o aparelho intra-oral. Em cada modelo, confeccionou-se planos de guia na face distal dos dentes 13 e 23 e nas faces proximais do dente 17. Cada superfície preparada (A, B, C e D) formou um ângulo em relação ao plano oclusal (a, b, d, q) que foram medidos com uma máquina de medidas de coordenadas tridimensionais. Os valores médios obtidos para o grupo 1 foram a= 91,19 ± 0,48o, b= 90,47 ± 0,66o, d= 90,21 ± 0,76o e q= 90,50 ± 0,73o e para o grupo 2, a= 92,18 ± 0,87o, b= 90,90 ± 0,85o, d= 90,07 ± 0,92o e q= 90,65 ± 0,73o. A aplicação do teste estatístico ANOVA two-way (5%), revelou que os efeitos tipo de aparelho, ângulos e interação apresentaram diferença significante. Ao se aplicar o teste de Tuckey (5%), verificamos que a superfície C, preparada pelo ParalAB foi mais paralela à trajetória de inserção (d= 90,07 ± 0,92o), seguida pela superfície C produzida pelo delineador de bancada (d= 90,21 ± 0,76o), e a mais concorrente foi a superfície A produzida pelo ParalAB (a= 92,18 ± 0,87o), seguida pela superfície A preparada pelo delineador de bancada (a= 91,19 ± 0,48o). As demais superfícies produzidas por ambos os aparelhos ocuparam uma posição intermediária de mesmo comportamento. Ao se aplicar o teste de Levène de comparação de variância, ambos os grupos não apresentaram diferença significante para as inclinações das superfícies por eles produzidas. Podemos concluir que o aparelho ParalAB foi capaz de preparar superfícies paralelas... / The aim of this study was to introduce a new intraoral paralleling device (ParalAB) and to verify its efficiency as a transference method of guide planes. Thirty casting models were divided into 2 groups (n=15): in the group 1, guide planes were prepared with a surveyor device and in the group 2, with the ParalAB device. In each model, guide planes were prepared at the distal face of teeth 13 and 23 and at the proximal faces of teeth 17. Each prepared surface (A, B, C and D) formed an angle related to the occlusal plane (a, b, d, q) that were measured with a tridimentional coordinate machine. The mean value for the group 1 were a= 91,19 l 0,48O, b= 90,47 l 0,66O, d= 90,21 l 0,76O and q= 90,50 l 0,73O and for the group 2 were a= 92,18 l 0,87O, b= 90,90 l 0,85O, d= 90,07 l 0,92O and q= 90,65 l 0,73O. The application of ANOVA two-way test (5%) revealed that there were significant difference in all effects: device, angle and interaction. The Tuckey test (5%) revealed that the C surface prepared with ParalAB was more parallel to the path of insertion (d= 90,07 l 0,92O), followed by C surface prepared with the surveyor device (d= 90,21 l 0,76O), and the less parallel was the A surface prepared with ParalAB (a= 92,18 l 0,87o), followed by the A surface prepared with the surveyor device (a= 91,19 l 0,48o). The other surfaces occupied the same intermediary position. The Levene test of variance comparison revealed that the surfaces prepared by devices presented no significant difference. Conclusion: ParalAB was able to prepare parallel surfaces and, although there were significant difference between the two groups, the ParalAB presented a small deviation of the absolute parallelism and can be considered a valid method to transfer the guide plans.
164

Avaliação da desadaptação e microdureza superficial de quatro resinas acrílicas para base de dentaduras utilizando métodos de polimerização e armazenagem em água

Miessi, Ana Carolina [UNESP] 29 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-29Bitstream added on 2014-06-13T19:37:36Z : No. of bitstreams: 1 miessi_ac_me_araca.pdf: 741354 bytes, checksum: ba78d27d53c30aac75b9b79cea2cc8e6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi avaliar a desadaptação e a microdureza superficial de quatro tipos de resinas acrílicas para base de dentaduras, em função de período de armazenagem em água de seis meses. Foram confeccionados vinte e cinco conjuntos modelo de gesso-base de resina, utilizando-se quatro resinas acrílicas: QC-20 que foi submetida à polimerização convencional (de acordo com as instruções dos fabricantes) e por energia de microondas (840 W por três minutos), Vipi Cril submetida à polimerização convencional (fabricante), Vipi Wave e Onda Cryl que receberam polimerização por energia de microondas conforme as recomendações dos fabricantes. Após a polimerização, os conjuntos modelo de gesso-base de resina foram seccionados na região posterior correspondente a região de post-dam para a leitura da desadaptação, com auxílio de um microscópio comparador, em três pontos referenciais: crista dos rebordos direito e esquerdo e região mediana do palato. Os conjuntos seccionados foram, então, imersos em água destilada a 35 l 2ºC por período de noventa dias, após o qual uma segunda leitura da desadaptação foi realizada. Imediatamente, os conjuntos modelo-base de resina foram separados e a bases de resina retiradas para a remoção dos excessos grosseiros da borda até o limite estabelecido pelo modelo de gesso. Posteriormente, as bases de resina acrílica foram fixadas nos respectivos modelos com adesivo de presa rápida colocado na região correspondente à crista do rebordo alveolar e uma terceira leitura para analisar a desadaptação, nos pontos referenciais, foi realizada. Após a terceira leitura, os conjuntos ficaram novamente imersos em água destilada a 35 l 2ºC e armazenados em estufa por um período de mais noventa dias, findo o qual uma quarta leitura nos pontos previamente demarcados foi... / The aim of this work was to evaluate the missfitting and the superficial microhardness of four acrylic resins types for dentures base due to storage period in six months water. 25 model sets of resin plaster-base have been confectioned using four acrylic resins: QC-20, which was submitted to the conventional polymerization (in accordance with the manufacturer's instructions) and microwaves energy polymerization (840W for three minutes) and Vipi Wave and Onda Cryl, which have received microwaves energy polymerization also in accordance with the manufacturer's recommendations. After the polymerization process, the model sets of resin plaster-base were parted in the corresponding posterior region, the post-dam region, for the missfitting analysis. This was supported by a comparing microscope in three reference points: right and left crest of ridges and palate's middle region. The parted sets have been, then, immersed in distilled water about 35 to 2°C, for a 90-day period which was followed by a second missfitting analysis. The resin base-model sets were immediately separated and the resin bases were immediately removed to promote the edge coarse excesses' removal until the limit established by the plaster model. Later, the acrylic resin bases were fixed in the respective models with fast stick adhesive, which was placed in the corresponding region to the alveolar crest of ridges. A third analysis to study the missfitting in the reference points was carried through. After the third analysis the sets were immersed again in distilled water about 35 to 2ºC and stored in a stove for a certain period, which exceeded 90 days. As soon as this period was finished, a fourth analysis was carried through in the points previously outlined (180 days total analysis period...(Complete abstract, click electronic address below)
165

Prótese parcial removível de extremidade livre associada a um implante osseointegrado: influência do ligamento periodontal na distribuição interna das tensões

Archangelo, Carlos Marcelo [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 archangelo_cm_me_araca.pdf: 2727002 bytes, checksum: 70ce356e1f90c64c2cd8afe4655ae354 (MD5) / Universidade Estadual Paulista (UNESP) / Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). / The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below)
166

Influência do processamento de próteses totais superiores em função da profundidade do palato: análise da movimentação dos dentes artificiais por computação gráfica

Vedovatto, Eduardo [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 vedovatto_e_me_araca.pdf: 3678407 bytes, checksum: 61a0add7350fb3375bfca3d4c3dcaff0 (MD5) / Universidade Estadual Paulista (UNESP) / Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. / About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis.
167

Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes /

Silva, Eduardo Galera da. January 1997 (has links)
Orientador: João Vieira de Moraes / Banca: Celso -Ite Tanaka / Banca: Maria Amélia Maximo de Araújo / Resumo: O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica / Abstract: This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements / Mestre
168

Efetividade da terapia fotodinâmica associada à soluções irrigadoras frente a dois modelos de biofilme / Effectiveness of photodynamic therapy associated with irrigants against two biofilm models

Rosa, Ricardo Abreu da January 2015 (has links)
O objetivo deste estudo foi avaliar o efeito antibacteriano e a dissolução de biofilme promovido pela terapia fotodinâmica (PDT) associada com o hipoclorito de sódio (NaOCl) 2,5% e a clorexidina (CHX) sobre biofilmes mono-espécie e multi-espécies. No modelo de biofilme mono-espécie, quarenta e seis prémolares inferiores foram contaminados com cepas de Enterococcus faecalis (ATCCC 29212) por 21 dias. Os espécimes foram divididos em três grupos de acordo com a solução irrigadora utilizada: soro fisiológico, CHX 2% e NaOCl 2,5%. Após irrigação com 5 mL de cada irrigante, a PDT foi realizada. Amostras foram coletadas previamente aos protocolos de irrigação (S1), após irrigação (S2) e após PDT (S3). No modelo de biofilme multi-espécies, sessenta blocos de dentina bovina foram infectados intraoral e divididos em seis grupos: soro fisiológico, soro fisiológico/PDT, CHX, CHX/PDT, NaOCl e NaOCl/PDT. Microscopia confocal a laser foi usada para avaliar a porcentagem e o biovolume de células vivas e o volume total de biofilme. Todos os grupos reduziram as contagens de UFCs após os procedimentos de irrigação (S1-S2); porém a CHX e o NaOCl promoveram as menores contagens de UFCs (P < 0,05). A PDT diminuiu significativamente a contagem bacteriana no grupo do soro fisiológico (S2-S3; P < 0,05). No modelo de biofilme multi-espécies, a menor quantidade de células vivas foi observada nos grupos CHX, CHX/PDT, NaOCl e NaOCl/PDT, sem diferenças entre si (P > 0,05). A PDT não reduziu o volume total de biofilme (P > 0,05); porém parece diminuir o biovolume e a quantidade de células vivas após irrigação com CHX 2% e NaOCl 2,5%. A terapia fotodinâmica associada ao soro fisiológico reduziu a carga bacteriana em canais infectados com E. faecalis. A PDT parece reduzir a quantidade e o volume de células vivas, mas não o volume total de células em biofilme multiespécies induzido in situ. Finalmente, o tipo de irrigante foi decisivo para dissolver biofilme multi-espécies. / The aim of this study was to evaluate the antibacterial effect and the biofilm dissolution promoted by photodynamic therapy (PDT) associated with 2.5% NaOCl and 2% CHX over monospecies and multispecies biofilms. In monospecies biofilm model, forty-six mandibular premolars were contaminated with Enterococcus faecalis strains (ATCC 29212) broth culture for 21 days. Specimens were divided into three groups according to the irrigant used: saline, 2% of CHX and 2.5% of NaOCl. After irrigation with 5 mL of each irrigant, PDT was performed. Samples were collected at baseline (S1), after irrigation (S2) and after PDT (S3). In multispecies biofilm model, sixty bovine dentin blocs were infected intraorally, and divided into six groups: saline, saline/PDT, CHX, CHX/PDT, NaOCl and NaOCl/PDT. Confocal laser scanning microscopy was used to assess the percentage and the biovolume of live cells and the total biovolume. All groups reduced UFC’ counts after irrigation procedures (S1-S2); however CHX and NaOCl promoted the lowest UFCs counts (P < 0.05). PDT significantly reduced the bacterial counts in saline group (S2-S3; P < 0.05). In multispecies biofilm model, the lowest amount of live cells was observed in CHX, CHX/PDT, NaOCl and NaOCl/PDT groups, with no differences among them (P > 0.05). PDT did not reduce the total biovolume (P > 0.05); however it appears to decrease the biovolume and the amount of live cells after irrigation with 2% CHX and 2.5% NaOCl. PDT associated with saline reduced the bacterial load in canal infected with E. faecalis. PDT seems to reduce the amount and the biovolume of live cells, but did not reduce the total biovolume of cells in multispecies biofilm induced in situ. Finally, the irrigant was decisive to dissolve multispecies biofilm.
169

Infiltração marginal em restaurações classe V com materiais adesivos - estudo &quot;in vitro&quot;-

Mainardi, Ana Paula Rorato January 1996 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-16T10:21:16Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T20:16:50Z : No. of bitstreams: 1 103738.pdf: 4798374 bytes, checksum: c766e51bbce856aa01557111a83bb3f0 (MD5) / Cavidades classe V, totalmente expulsivas, em forma de "V", foram preparadas nas faces vestibulares de 50 pré-molares, simulando lesões de erosão-abrasão. Os corpos de prova foram restaurados com: Scotchbond Multi-Purpose e Z100; Vitremer; VariGlass VLC; Ketac-Fil e Vitrebond, Scotchbond Multi-Purpose e Z100. Para avaliar a microinfiltração na interface dente-restauração os corpos de prova sofreram uma ciclagem térmica, totalizando 2000 ciclos, e foram imersos em uma solução aquosa de Rhodamina B a 0,1%. Os níveis de infiltração marginal mostraram-se, consideravelmente, elevados. Dos cinco sistemas restauradores adesivos estudados, pode-se considerar que o desempenho do cimento de ionômero de vidro Ketac-Fil, quanto à capacidade de selamento marginal, foi melhor em comparação ao dos outros materiais empregados neste estudo in vitro.
170

Vibrador portátil para vazamento de gesso

Andrade, Pâmela Cândida Aires Ribas de 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T22:51:54Z (GMT). No. of bitstreams: 1 279304.pdf: 1211484 bytes, checksum: 7676c2e7e604389e18e926d70a3edc81 (MD5) / Vazamentos de modelo para confecção de prótese sobre implante podem alterar a posição do análogo, tendo como consequência problema de desajuste da prótese. A proposta do presente estudo foi testar um vibrador portátil para vazamento de gesso (desenvolvido para esse fim), comparando-o com outras técnicas de vazamento com vibradores convencionais. A partir de um modelo mestre com 2 implantes, 30 moldagens de transferência foram realizadas e divididas em três grupos: Grupo I (GI): vazamento feito em laboratório de prótese terceirizado, com vibrador convencional (10 modelos); Grupo II (GII): vazamento no laboratório da Universidade Federal de Santa Catarina, com vibrador convencional (10 modelos); Grupo III (GIII): vazamento com vibrador portátil fabricado para este estudo (10 modelos). A posição dos análogos e adaptação marginal da infraestrutura foram verificadas pelo teste do parafuso único no modelo mestre e subsequentes modelos de trabalho, e a mensuração do desajuste foi realizada por um microscópio de precisão e unidade analisadora Quadra-Check 200. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e teste Holm-Sidak (? = 0,05). Os valores médios (?m) foram (média±dp): GI: 19,19±4,73?m, GII: 21,72±5,41?m, GIII: 13,5±2,39?m, sendo estes os valores estatisticamente inferiores aos dois primeiros grupos. Dentro das condições deste estudo, foi possível concluir que a maior precisão dos modelos de trabalho foi conseguida quando se utilizou o vibrador portátil para vazamento dos moldes.

Page generated in 0.079 seconds