• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 278
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 281
  • 115
  • 107
  • 104
  • 101
  • 80
  • 78
  • 70
  • 64
  • 41
  • 35
  • 35
  • 35
  • 30
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação da união zircônia-cimento resinoso-dentina com diferentes estratégias de cimentação e de envelhecimento

Castro, Humberto Lago de [UNESP] 22 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-04-22Bitstream added on 2014-06-13T20:25:48Z : No. of bitstreams: 1 000757377.pdf: 1274710 bytes, checksum: 63373d7b950cbcf3c95f4712d9137691 (MD5) / Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva () de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- Panavia F) entre a dentina e uma cerâmica à base de zircônia estabilizada por óxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados, planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤ 45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinosocerâmica foram cortados no sentido x e y, produzindo, aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento: armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); e termociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey (=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de  (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de . O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de  nos grupos RX / The aim of this study was to evaluate the bond strength () of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanavia F) to dentin and yttria-stabilized zirconia-based ceramic (YZIn- Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers’ instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²). Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12). The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA 30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups
72

Avaliação da biocompatibilidade e do processo de reparo dos cimentos endodônticos: MTA Fillapex, Endo-CPM-Sealer e Sealapex

Watanabe, Simone [UNESP] 05 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-05Bitstream added on 2014-06-13T21:07:35Z : No. of bitstreams: 1 watanabe_s_dr_araca.pdf: 1959528 bytes, checksum: 1744de13ccd7ec1e15e0ab0dbd88c788 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar a resposta tecidual frente ao implante de tubos de polietileno preenchidos pelos cimentos Sealapex®, Endo-CPM-Sealer® e MTA Fillapex® em tecido subcutâneo de ratos, bem como avaliar o processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, obturados com os mesmos cimentos. Para o teste de biocompatibilidade foram utilizados 30 ratos, os quais receberam individualmente três implantes de tubos de polietileno contendo os cimentos a serem testados e mais um tubo vazio como controle. Os períodos de avaliação foram de 7, 15, 30, 60 e 90 dias. Os espécimes foram processados laboratorialmente e analisados nas colorações de Hematoxilina e Eosina, Von Kossa e sem coloração para análise sob luz polarizada. Foram atribuídos escores e os dados obtidos foram analisados pelo teste Kruskal Wallis. Todos os materiais causaram reações moderadas no tempo experimental de 7 dias. A resposta foi moderada e similar para o grupo controle no 15° dia com Sealapex® e Endo-CPM-Sealer®. O grupo MTA Fillapex® apresentou reações leves a partir do 15° dia. Mineralizações e granulações brirrefringentes à luz polarizada foram observadas com todos os materiais. Foi possível concluir que todos os materiais testados apresentaram resultados similares, sendo considerados biocompatíveis e estimulantes de mineralização. Para a avaliação do processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, foram empregados 62 canais radiculares de 2 cães machos da raça Beagle. Os animais foram anestesiados, as polpas foram extirpadas e os canais ficaram expostos ao meio oral para o desenvolvimento de lesões periapicais. Após 6 meses os dentes foram tratados endodonticamente e foram divididos em 5 grupos experimentais... / The aim of this study was to evaluate the tissue response to implanted polyethylene tubes filled with Sealapex®, Endo-CPM-Sealer® and MTA Fillapex® in rat subcutaneous tissue, and to evaluate the healing process of dogs' teeth with experimental periapical lesions filled with the same sealers. For the biocompatibility test, it were used thirty rats, which received three individual implants of polyethylene tubes containing the sealers to be tested and an empty tube as control. Evaluations periods were on 7, 15, 30, 60 and 90 days. The specimens were laboratory processed and analyzed in Hematoxylin and Eosin, Von Kossa and without staining for polarized light. Scores were assigned and data were analyzed by Kruskal Wallis test. Both materials caused mild to moderate reactions on 7 days. The response was moderate and similar to the control at the 15th day with Sealapex® and Endo-CPM-Sealer®. MTA Fillapex® evoked mild reactions from the 15th day on. Mineralization and granulations birefringent to the polarized light were observed with all materials. It was possible to conclude that all materials tested showed similar results and they are considered biocompatible and stimulating mineralization. For the evaluation of the healing process of dogs' teeth with periapical lesions, sixty-two roots canals of two male beagle dogs were used. The animals were anesthetized, pulpectomy were performed and the canals remained open and exposed to the oral environment to induce a periapical lesion. After 6 months the teeth were endodontically treated and divided into 5 experimental groups, according to the filling material: Group I Sealapex®; Group II – Endo-CPM-Sealer®; Group III – MTA Fillapex®; Group IV – positive control; Group V – negative control. After 180 days, the animals were killed, the specimens were removed... (Complete abstract click electronic access below)
73

Resistência de união de cimentos resinosos em superfície de cerâmica de Y-TZP após aplicação de filme vitrocerâmico

Antunes, Débora Pinto [UNESP] 08 April 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-08Bitstream added on 2015-05-14T16:59:11Z : No. of bitstreams: 1 000822661.pdf: 3005956 bytes, checksum: aa617124450c9641b6ecb66c3cbbdaa9 (MD5) / Comparou-se a resistência de união (RU) dos cimentos resinosos Panavia F (P) (Kuraray) e RelyX U200 (R) (3M ESPE) à cerâmica zircônia através de três diferentes métodos de tratamento da superfície: 1- silicatização triboquímica (ST) (Rocatec Soft - 3M ESPE); 2- glaze (G) (Akyzent glaze spray- VITA); 3- aplicação de vidro bioativo (VBA). Blocos pré-sinterizados do sistema Zirkonzahn (Zirkonzahn) foram seccionados de modo a produzir 90 blocos menores (5 x 4 x 3 mm). Os blocos foram polidos em Politriz com lixas d’água de granulação fina 1000 e 1200 (3M ESPE) e limpos em banho ultrassônico contendo álcool isopropílico a 96% durante 5 min. Após a sinterização dos blocos cerâmicos, foi realizada a aplicação do tratamento de superfície. O Rocatec Soft foi jateado com 2,8 bar, ângulo de incidência perpendicular e distância padrão de 10 mm por 25 s em movimentos circulares. O Akyzent Glaze Spray foi pulverizado por 2 s e em seguida sinterizado em forno Vacumat (Vita) de acordo com recomendações do fabricante. Após a aplicação de 1 gota do vidro bioativo, procedeu-se a secagem e sinterização a 1200 ºC deste material. Em todos os grupos aplicou-se agente de união silano Monobond-S (Ivoclar Vivadent). Nos grupos 3, 4, 5 e 6 a superfície foi primeiramente condicionada com ácido hidrofluorídrico (HF) a 5% durante 2 min, lavada e depois silanizada. A cimentação foi realizada com um dispositivo (Ultradent), produzindo cilindros de cimento resinoso com 2 x 1mm.! Após 24 h os espécimes foram envelhecidos em termocicladora com 5.000 ciclos com banhos de temperatura entre 5 e 55 ºC e submetidos ao ensaio de cisalhamento na Shear Bond Tester (Bisco). O VBA foi analisado qualitativamente por meio de análise térmica diferencial (DTA), através de difração de raios-x (DRX)(Panalytical) e espectroscopia de energia dispersiva de raio-x (EDS) (Oxford Instruments)... / The bond strength of resin cements Panavia F (P) (Kuraray) and RelyX U200 (R) (3M ESPE) to zirconia using three different surface treatments: 1 - triboquemical silicatization (ST); 2 - glaze (G) 3 - bioactive glass (VBA) was compared. Blocks of Zirkonzahn system were cut producing 90 smaller blocks (5 x 4 x 3 mm). The blocks were polished with water finegrained 1000 and 1200 sandpaper in Politriz and cleaned with 96% isopropyl alcohol for 5 min. The Rocatec Soft was etched with 2.8 bar, in a perpendicular way and a distance of 10 mm for 25 s in a circular motion. The Akyzent Glaze Spray was sprayed by 2s and then sintered in oven Vacumat (Vita) according to manufacturer's recommendations. After application of 1 drop of bioactive glass, the material was dried and sintered at 1200 °C. In all groups was applied silane coupling agent Monobond- S (Ivoclar Vivadent). In groups 3, 4, 5 and 6 the surface was first etched with 5% hydrofluoric acid (HF) and then silanized. The cementing was carried out with a device (Ultradent), producing cured cement cylinders of 2 x 1mm. After 24 h the specimens were aged in thermocycler with 5,000 cycles at a temperature of 5 and 55 ºC and subjected to microshear test on Shear Bond Tester (Bisco). VBA was analyzed by means of DTA, XRD and EDS. Optical profilometry (PO) was performed to obtain roughness. After fracture the samples were analyzed through SEM. It was found that XRD revealed the formation of a glass ceramic film. DTA shows that the temperature of 1200 °C is the most suitable for sintering. DRX showed the formation of a glass ceramic film. According to ANOVA, the interaction effect was significant (p = 0.003 < 0.05). The test for multiple comparison of means, Tukey (5%) showed that the TBS (MPa) for VBA were significantly higher than the other groups (with 26.94 ± 3.50 to P and 28.36 ± 3.32 to R), regardless cement kind used. The lowest result...
74

Análise comparativa da ação antimicrobiana dos cimentos endodônticos Acroseal, Sealapex e AH plus pós presa em biofilme de enterococcus faecalis

Rezende, Gabriely Cristinni [UNESP] 23 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-23. Added 1 bitstream(s) on 2015-06-18T12:47:49Z : No. of bitstreams: 1 000830347.pdf: 242986 bytes, checksum: 3957e431d5fb3368b3a93a697bd645dd (MD5) / Enterococcus faecalis é uma bactéria Gram-positiva que pode resistir ao tratamento endodôntico e manter a infecção presente no sistema de canais radiculares. Assim, o uso de cimentos endodônticos com atividade antimicrobiana pode ajudar a eliminar microrganismo residuais que sobreviveram após o tratamento endodôntico. Diante dessa realidade, o presente estudo teve por objetivo avaliar comparativamente a ação antimicrobiana dos cimentos endodônticos Acroseal, Sealapex e AH Plus em um modelo de biofilme in vitro. Para a realização do estudo foram confeccionados 144 espécimes de dentina bovina, sendo doze blocos para cada cimento em cada tempo experimental que permaneceram em placas contendo meio de cultura inoculado com E. faecalis (ATCC 51299) para permitir a formação de biofilme. Decorrido 14 dias, os espécimes foram transferidos para outra placa onde discos dos cimentos testados foram colocados sobre o biofilme formado. As placas de cultura foram deixadas em estufa a 37°C e 5% de CO2 por 2, 7 e 14 dias. Espécimes sem aplicação dos cimentos foram utilizados como controle para cada período. Após cada tempo experimental, as amostras foram agitados em sonicador. As suspensões foram agitadas em vortex e foi realizada uma diluição seriada decimal em solução salina, sendo estas diluições plaqueadas em triplicata em meio de cultura m-Enterococcus ágar. As unidades formadoras de colônia foram contadas e os dados analisados estatisticamente usando os teste ANOVA, Shapiro-Wilk e Kruskal-Wallis one-way (p<0,05) para determinação do potencial antimicrobiano. Resultados: O Sealapex apresentou diferença estatística em todos os tempos experimentais quando comparado com os demais grupos. O AH Plus e o Acroseal mostraram atividade antimicroabina apenas no 14o dia de experimento. Conclusão: Nenhum... / Enterococcus faecalis is a gram positive bacteria that can resist to the endodontic therapy and maintain the infection present in the root canal system. Therefore, the use of endodontic sealers with antimicrobial activity could help to eliminate residual microorganism that have survived after endodontic treatment. The present study aimed to compare the antimicrobial activity of the endodontic sealers Acroseal, Sealapex and AH Plus in vitro biofilm model. It were prepared 144 bovine dentin specimens, twelve blocks for each cement in each experimental time that remained in plates containing culture medium inoculated with E. faecalis (ATCC 51299) for biofilm formation. After 14 days, the samples were transferred to another plate with test sealers and were kept at 37oC and 5% CO2 for 2, 7 and 14 days. Specimens without sealers were used as a control for each period. After each experimental, the samples were agitated in sonicator. The suspensions were agitated in vortex and serially diluted in saline and triple plaqued in m-Enterococcus agar. Colony forming unit were counted and the data were statistically analyzed using ANOVA, Shapiro-Wilk and Kruskal-Wallis one-way test (p<0.05) for the antimicrobial potential determination. Results: Sealapex showed significant difference in all experimental times in comparison to all other groups. AH Plus and Acroseal showed antimicrobial activity just at 14th experimental day. Conclusion: Neither of sealers setting tested was able to remove biofilm . The Sealapex showed higher antimicrobial activity in all experimental periods. All sealers examined the antimicrobial effectiveness was higher with over time
75

Abordagens estatísticas em testes de resistência de união entre dentina bovina, sistema adesivo e resina composta

Balducci, Ivan [UNESP] 25 April 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-25. Added 1 bitstream(s) on 2015-09-17T15:47:55Z : No. of bitstreams: 1 000844174.pdf: 1728436 bytes, checksum: 6c4b793420a35ded6629f8099de66606 (MD5) / O objetivo deste estudo foi empregar diferentes abordagens estatísticas em dados obtidos em ensaios de micro e macrotração, em dois períodos de tempo de armazenamento, a fim de descrever e quantificar a variabilidade comumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmalte e as faces vestibulares foram desgastadas expondo superfície de dentina plana. Os dentes foram embutidos em resina acrílica e aleatoriamente designados a quatro grupos (n = 12) para avaliação da resistência de união (RU). Para o teste de microtração foi aplicado o adesivo Adper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguido de jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foi obtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmo resultados. Pode-se concluir: as diferentes... / The aim of this study was to use different statistical approaches on data obtained from micro and macrotensile tests in two periods of time storage, in order to describe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibull analysis for the data of BS (MPa) of the experimental conditions were: G1 (module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%), complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison betw...
76

Influência do tempo de endurecimento no comportamento físico e biológico de sete cimentos endodônticos

França, Monique Costa Moreira [UNESP] 18 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-18. Added 1 bitstream(s) on 2015-09-17T15:47:05Z : No. of bitstreams: 1 000843350.pdf: 2776777 bytes, checksum: 117622a7940320916a6831aad9adae9a (MD5) / Objetivo: O objetivo deste estudo foi avaliar a influência do tempo de endurecimento sobre as propriedades físicas (teste de push-out) e biológicas (XTT, MNT) de sete cimentos endodônticos: Apexit Plus, Real Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone N e o cimento biocerâmico iRoot SP. Material e Métodos: Para a análise da citotoxicidade (XTT), foram utilizados fibroblastos do ligamento periodontal humano (PDLF). Para o número de micronúcleos (MNT), este estudo avaliou culturas de células expostas a diluições dos cimentos testados sobre células V79 No teste de push-out foram usados cento e quarenta dentes humanos unirradiculares que tiveram suas coroas removidas. Os canais radiculares foram preparados biomecanicamente com o sistema rotatório Mtwo (VDW GmbH, München, Alemanha) até o número de série 702 a 25 mm (25-40). Durante todo o preparo biomecânico, os canais foram irrigados com 2 ml de hipoclorito de sódio. Os espécimes foram seccionados em fatias de 2 mm nos terços cervical, médio e apical. O teste de Push-out foi realizado a uma velocidade de 1 mm / min e célula de carga de 50 Kgf. Os testes biológicos foram avaliadas após 24 h, 72 h, 1 semana, 1 mês, 3 meses, 6 meses e um ano após a manipulação e o teste de push-out 15 dias e 1 ano.Os dados foram analisados pelo teste de Kruskal-Wallis e teste de Dunn (p = 0,05). Resultados: IRooot SP, Roeko seal, Apexit Plus, AH Plus e Real Seal não mostraram citotoxicidade nas células PDLF. AH Plus, Real Seal, IRooot SP e Endomethasone N não apresentaram genotoxicidade. Roeko Seal e Apexit Plus mostraram ser genotóxico e EndoRez apresentou alta genotoxicidade. Roeko Seal, IRooot SP e EndoRez tiveram menor resistência à tração nos terços apical, médio e cervical, tanto em 15 dias e 1 ano de análise. Além disso, Endomethasone N, Real Seal e AH Plus apresentaram uma força de adesão satisfatória após 1 ano em todos os terços. Conclusão: conclui-se que... / Objective: The aim of this study was to evaluate the influence of curing time on physical (push-out test) and biological properties (XTT, MNT) of seven sealers: Apexit Plus, Royal Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone, and bioceramic cement iRoot SP. Material and Methods: To the citotoxity analysis (XTT), fibroblasts of the human periodontal ligament were used (PDLF). To the number of micronuclei (MNT), this study evaluated cell cultures exposed to dilutions of the tested sealers, among them from causing excessive cytotoxic effects on V79 cells. To push-out test was used one hundred and forty single-rooted teeth which had the crowns removed. The root canals were prepared biomechanically with the rotary system Mtwo (VDW GmbH, München, Alemanha) until to series number 702 to file 25 mm (25-40). Throughout the biomechanical preparation, the canals were irrigated with 2 ml of sodium hypochlorite. The specimens were sectioned in slices of 2 mm in cervical, middle and apical. The push-out test was performed at speed of 1 mm/min and 50 kgf load cell. The tests were evaluated after 24 h, 72 h, 1 week, 1 month, 3 months, 6 months and one year after manipulation. Data were analyzed by Kruskal-Wallis and Dunn test (p = 0.05). Results: IRooot SP, Roeko Seal, Apexit Plus, AH plus and Real Seal showed no cytotoxicity in PDLF cells. AH plus, Real Seal, IRooot SP and Endomethasone N showed no genotoxicity. Roeko Seal and Apexit Plus have shown to be genotoxic and EndoRez showed high genotoxicity. Roeko Seal, IRooot SP and EndoRez had lower bond strength in the apical, middle and cervical thirds in both the 15-day and 1 year analysis. Apexit Plus, Endomethasone N, Real Seal and AH plus had a satisfactory bond strength after 1 year in all thirds. Conclusion: It is conclude that AH plus and Real Seal were the sealer with lower cytotoxicity and genotoxicity, with good values of bond strength in all third, keeping as the material of choice for....
77

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental

Crastechini, Érica [UNESP] 14 January 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-14Bitstream added on 2014-08-13T17:59:38Z : No. of bitstreams: 1 000776317.pdf: 1195102 bytes, checksum: 85fc35fb403e655b035d4a9783d36061 (MD5) / O objetivo deste estudo foi avaliar a eficácia do laser Nd:YAG associado a diferentes sistemas adesivos autocondicionantes, na prevenção do desgaste erosivo e abrasivo do esmalte dental. Foram preparados 160 espécimes de esmalte bovino, polidos e submetidos a uma erosão inicial em ácido cítrico a 0,3 % por 5 min. Os perfis iniciais da superfície de esmalte foram medidos utilizando um perfilômetro, cuja unidade de medida é em micrométros (μm). Os espécimes foram distribuídos aleatóriamente em oito grupos (n=20): SB - Aplicação do adesivo Single Bond Universal (3M/Espe) e fotopolimerização; SB+L - Aplicação do adesivo Single Bond Universal, irradiação do laser de Nd:YAG (80 mJ,10 Hz) e fotopolimerização; FB - Aplicação do adesivo Futura Bond U (Voco) e fotopolimerização; FB+ L - Aplicação do adesivo Futura Bond U, irradiação do laser de Nd:YAG e fotopolimerização; GEN - Aplicação do adesivo G-aenial Bond (GC) e fotopolimerização; GEN +L - Aplicação do adesivo G-aenial Bond, irradiação do laser de Nd:YAG e fotopolimerização; L - Apenas irradiação do laser Nd:YAG; C - nenhum tratamento (Controle). Em seguida foram realizados diariamente os desafios erosivo, utilizando ácido cítrico a 0,3% (pH 2,6) por 2 min, e abrasivo realizado em uma máquina de escovação (40 ciclos, carga 200 g) com dentifrício diluído em saliva artificial (1:3 peso/peso). Foram realizados quatro ciclos por dia, durante 5 dias. Os perfis das superfícies do esmalte foram novamente avaliados utilizando um perfilômetro. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. O nível de significância foi de 5 %. Para a ANOVA foram observadas diferenças estatisticamente significantes (p= 0,0000) de desgaste. Os valores de média (±dp) e os resultados do teste Tukey foram: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN .... / The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles, load of 200 g) with toothpaste diluted in artificial saliva (1:3 wt/wt), were performed. Four cycles a day were performed during 5 days. The profiles of the enamel surfaces were again measured using the profilometer. Data were analyzed using analysis of variance (ANOVA) and Tukey statistical tests. The level of significance was 5%. When ANOVA (one factor) test was applied, it was observed statistical difference (p=0,0000) of surface wear. Mean values (± SD) and results of the Tukey test were: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN + L – 5,46 (±1,27) abc; SB + L – 5,78 (±1,12) abc; FB + L – 6,23 (±1,25) bc; SB - 6,35 (±1,11) c; C .....
78

Influência do tratamento de superfície e do tipo de cimento na retenção de coroas YTZP

Rippe, Marília Pivetta [UNESP] 28 November 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-11-28Bitstream added on 2014-08-13T17:59:34Z : No. of bitstreams: 1 000776628.pdf: 1391190 bytes, checksum: 0560fce743da2fc01c2682581e067e18 (MD5) / Comparar a retenção de coroas de zircônia YTZP em função do protocolo de cimentação. Foram preparados para coroa total 108 molares extraídos (n = 12). Pinos de fibra de vidro foram cimentados e núcleos de resina composta construídos. Infraestruturas de zircônia YTZP foram fresadas e 72 espécimes foram alocados em 6 grupos conforme os fatores: cimento - Multilink (Mult) e Relyx ARC (Rel); e tratamento de superfície da zircônia – álcool (controle) (C), silicatização (S) e vitrificação (V). Os outros 36 espécimes foram divididos em 3 grupos cimentados com Relyx Luting (Ion), Relyx U100 (Self) e fosfato de zinco (Zinc) sem tratamento da zircônia. Todos os espécimes foram termociclados (5 - 55 ºC, 6000 ciclos) e os dados do teste de tração foram analisados pelo teste de Kruskal Wallis e Dunn. Os valores da mediana e distância interquartil foram os seguintes: MultC: 20,0 (± 5,5); MultS: 28,5 (± 22,0); MultV: 32,5 (± 28,5); RelC: 21,5 (± 8,5); RelS: 22,0 (± 10,0); RelV: 24,0 (± 7,3); Ion: 5,1 (± 6,4); Self: 3,5 (± 5,2); Zinc: 7,7 (± 14,2). O tipo de cimento resinoso (a base de Bis-GMA e HEMA) não afetaram os valores de retenção das coroas. O tratamento de superfície da cerâmica vitrificação somente foi capaz de melhorar os valores de retenção para o cimento a base de HEMA. Para superfícies cerâmicas não tratadas, os cimentos resinosos mostraram significantemente maiores valores de retenção do que aqueles obtidos para os cimentos auto-adesivo, de inonômero de vidro e de fosfato de zinco / To compare the retention of YTZP zirconia crowns cemented to different cementation protocols. 108 extracted molars were prepared for full crown (n = 12); and the core was reconstructed with glass fiber post and composite resin core. YTZP zirconia copings were milled and 72 specimens were divided into 6 groups according to the factors: cements- Multilink (Mult) and Relyx ARC (Rel); and zirconia surface treatments- alcohol (control) (C), silica coating (S) and vitrification (V). The remaining 36 specimens were divided into 3 groups cemented with Relyx Luting (Ion), Relyx U100 (Self) and Zinc phosphate (Zinc) on untreated zirconia. The specimens were thermally cycled (5 - 55 °C, 6000 cycles) and data from the tensile test were analyzed by Kruskal Wallis and Dunn test. The median and interquartil range were: MultC: 20.0 (± 5.5); MultS: 28.5 (± 22.0); MultV: 32.5 (± 28.5); RelC: 21.5 (± 8.5); RelS: 22.0 (± 10.0); RelV: 24.0 (± 7.3); Ion: 5.1 (± 6.4); Self: 3.5 (± 5.2); Zinc: 7.7 (± 14.2). The type of resin cement (BIS-GMA- or HEMA- based) did not affect the crown retention values. The treatment involving vitrification of the cementation surface was only capable to improve the retention force for the HEMA based-cement. For untreated intaglio surfaces of YTZP crowns, resin cements showed significantly higher retention than those obtained for self-adhesive, glass ionomer and zinc phosphate cements
79

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23)

Pontes, Elaine Cristina Voltolini [UNESP] 25 February 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-25Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000796605.pdf: 2231117 bytes, checksum: 2cb8d762ad76e855d47d13daf8e4e4f2 (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells.
80

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes

Figueiredo, Aldari Raimundo [UNESP] 27 June 1997 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-27Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000126156.pdf: 4088167 bytes, checksum: 897cd22c86f9dc36f2eb1dddb6805462 (MD5) / Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White)

Page generated in 0.0532 seconds