• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 39
  • 16
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 113
  • 113
  • 62
  • 47
  • 40
  • 39
  • 35
  • 28
  • 25
  • 17
  • 14
  • 13
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Guide plane retention in removable partial dentures

Mothopi, Matshediso M January 2011 (has links)
A research report submitted for partial completion of Masters in Dentistry in Prosthodontics / Purpose: The purpose of this study was to measure and compare the influence of abutment teeth guide planes and partial denture guiding surfaces on the retention of removable partial dentures. Method: An upper typodont model was modified by removing both second premolars and first molars, thus creating two bounded saddles. An impression of the model was made with irreversible hydrocolloid and a cast poured, on which an acrylic resin based removable partial denture (RPD) was made. To this denture a hooking device was added so that the model and denture could be placed on a custom-made platform and jig on a universal testing machine (Instron, UK). The RPD was then removed from the model along its path of insertion (perpendicular to the occlusal plane) as well as at 2° and 5° and the maximum load recorded. The typodont model was then modified by making guide planes on the abutment teeth, and a second RPD made and the procedure repeated. This RPD was then modified by creating guiding surfaces directly against the guide planes using autopolymerising resin, and the procedure again repeated. Each measurement was made 10 times at each path of insertion/withdrawal, resulting in 90 measurements. Results There were some differences between the different paths of withdrawal in each of the three situations, explicable by the lack of ideal contact in the first two dentures, and the much improved contact in the third, which caused the teeth in the model to move on withdrawal. Overall,there were significant differences between the three models. There 5 was a significant increase in retentive force of 1.6 times from denture 1 to denture 2, of 7.6 times from denture 2 to denture 3, and 12.3 times from denture 1 to denture 3. Conclusion This study confirmed that guide planes increase the retention of an RPD, but that when guiding surfaces of the denture are adapted closely to the guide planes on the teeth, there is a considerable increase in retention
2

The efficiency of an indirect retainer a thesis submitted in partial fulfillment ... in denture prosthodontics ... /

Fisher, Richard L. January 1972 (has links)
Thesis (M.S.)--University of Michigan, 1972.
3

The superplant A clinical, radiologic, histologic and bacteriologic follow-up investigation of a type of fixed saddle-bridge.

Izikowitz, Lennart. January 1966 (has links)
Akademisk avhandling--Karolinska Mediko-Kirurgiska Institutet, Stockholm. / Extra t.p., with thesis statement, inserted. Bibliography: p. 156-159.
4

Die Verankerungsmittel für die partielle Prothese mit besonderer Berücksichtigung der Attachments Inaugural-Dissertation zur Erlangung der Doktorwürde in der Zahnheilkunde einer Hohen Medizinischen Fakultät der Georg-Auguest-Universität zu Göttingen /

Ludewig, Ernst, January 1932 (has links)
Thesis (doctoral)--Universität Göttingen, 1932. / At head of title: Aus der Abteilung für Zahn- und Kieferesatz ... des Zahnärtzlichen Instituts an der Georg-August-Universität zu Göttingen. "Lebenslauf": p. [29].
5

Distribution of load with the lower free-end partial denture Some factors of importance for the distribution of load to the saddle base and the supporting teeth in the light of model experiments.

Hekneby, Magne. January 1969 (has links)
Akademisk avhandling--Karolinska Institutet. / Extra t.p., with thesis statement, inserted. "Errata": leaf inserted. Bibliography: p. 187-190.
6

Levensduur en nabehandelingen van kronen en conventionele bruggen in de algemene praktijk Survival rate and retreatments of crowns and conventional bridges in general practice = Lebensdauer und nachbehandlung von Kronen und konventionellen Brücken in der allgemeinen Praxis /

Leempoel, Petrus Johannes Balthasar. January 1900 (has links)
Thesis (doctoral)--Katholieke Universiteit te Nijmegen, 1987. / Text in Dutch, with summaries in English and German. Vita. Includes bibliographical references (p. 185-193).
7

The partial denture its origin and development : thesis /

Applegate, Oliver C. January 1937 (has links)
Thesis (M.S.)--University of Michigan, 1937.
8

The efficiency of an indirect retainer a thesis submitted in partial fulfillment ... in denture prosthodontics ... /

Fisher, Richard L. January 1972 (has links)
Thesis (M.S.)--University of Michigan, 1972.
9

Klinische und experimentelle Untersuchungen von V2A-Stahldraht und seiner Verwendungsmöglichkeit zur Verankerung von Teilprothesen

Mayr, Kornel. January 1934 (has links)
Thesis (doctoral)--München, 1934.
10

Geteilte Wipla-Stahldrahtklammern im Vergleich zur Schleifenklammer

Hagelstein, Hans. January 1933 (has links)
Thesis (doctoral)--Universität Hamburg, 1933.

Page generated in 0.0629 seconds