• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo in vitro do efeito de agentes anti-hiperestésicos na permeabilidade dentinária por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica / In vitro study of the effect of anti-hyperesthesic agents in dentin permeability through hydraulic conductance and electrochemical impedance spectroscopy

Canova, Giovana Calicchio 20 September 2007 (has links)
O objetivo do presente estudo foi quantificar, in vitro, a permeabilidade da dentina tratada com dois agentes anti-hiperestésicos à base de oxalato e um à base de fosfato de cálcio, por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica e, ainda, determinar se espectroscopia de impedância eletroquímica pode ser considerada um método alternativo para avaliar a capacidade obstrutiva de agentes antihiperestésicos. Para o teste de condutividade hidráulica foram utilizados vinte quatro discos de dentina, obtidos de terceiros molares humanos extraídos, que foram divididos em três grupos de oito espécimes, correspondentes aos três materiais testados: gel Experimental, Sensi Kill e BisBlock. Outros dezoito discos foram selecionados para o teste de espectroscopia de impedância eletroquímica, sendo divididos em três grupos de seis espécimes, correspondentes aos três agentes anti-hiperestésicos citados anteriormente. Para ambos os testes as medidas foram realizadas nas seguintes condições: na presença de smear layer; após condicionamento com ácido fosfórico a 37% e após a aplicação dos materiais na superfície oclusal dos discos de dentina. Com base na análise estatística dos resultados, verificou-se, por meio dos dois métodos utilizados, que o gel Experimental e o BisBlock apresentaram efeitos estatisticamente semelhantes na redução da permeabilidade e foram significantemente mais eficientes que o Sensi Kill. Pode-se concluir que os agentes anti-hiperestésicos Experimental e BisBlock mostraram-se efetivos na redução da permeabilidade dentinária, pelos dois métodos de avaliação, e que o método de espectroscopia de impedância eletroquímica pode ser considerado um método alternativo para a avaliação da capacidade obstrutiva de agentes anti-hiperestésicos. / The aim of the present study was to quantify in vitro the dentin permeability of dentin treated with two potassium oxalate dentin desensitizers and one calcium phosphate agent through hydraulic conductance (Lp) and eletrochemical impedance spectroscopy (EIS) tests and, yet, to determine whether EIS may be considered a suitable alternative method to evaluate the occlusive capacity of the dentin desensitizers. For the hydraulic conductance, twenty-four dentin discs were obtained from extracted human third molars, which were divided into three groups of eight specimens, corresponding to the materials to be tested: Experimental gel, Sensi Kill and BisBlock. Other eighteen dentin discs were selected for theEIS and divided into three groups of six specimens corresponding to the three dentin desensitizers mentioned before. For both tests, the following conditions were measured: in the presence of smear layer, after 37% phosphoric acid etching and after the application of the tested materials in the occlusal surfaces of dentin discs. Based upon the statistical analysis of the results, it was demonstrated by both methods that Experimental gel and BisBlock performed statistically similarly in reducing dentin permeability and were significantly more efficient that Sensi Kill. It can be concluded that the dentin desensitizers Experimental e BisBlock were demonstrated to be effective in the reduction of dentin permeability by both experimental methods and that EIS may be considered as an alternative method for the evaluation of the obstructive capacity of dentin desensitizers.
2

Estudo in vitro do efeito de agentes anti-hiperestésicos na permeabilidade dentinária por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica / In vitro study of the effect of anti-hyperesthesic agents in dentin permeability through hydraulic conductance and electrochemical impedance spectroscopy

Giovana Calicchio Canova 20 September 2007 (has links)
O objetivo do presente estudo foi quantificar, in vitro, a permeabilidade da dentina tratada com dois agentes anti-hiperestésicos à base de oxalato e um à base de fosfato de cálcio, por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica e, ainda, determinar se espectroscopia de impedância eletroquímica pode ser considerada um método alternativo para avaliar a capacidade obstrutiva de agentes antihiperestésicos. Para o teste de condutividade hidráulica foram utilizados vinte quatro discos de dentina, obtidos de terceiros molares humanos extraídos, que foram divididos em três grupos de oito espécimes, correspondentes aos três materiais testados: gel Experimental, Sensi Kill e BisBlock. Outros dezoito discos foram selecionados para o teste de espectroscopia de impedância eletroquímica, sendo divididos em três grupos de seis espécimes, correspondentes aos três agentes anti-hiperestésicos citados anteriormente. Para ambos os testes as medidas foram realizadas nas seguintes condições: na presença de smear layer; após condicionamento com ácido fosfórico a 37% e após a aplicação dos materiais na superfície oclusal dos discos de dentina. Com base na análise estatística dos resultados, verificou-se, por meio dos dois métodos utilizados, que o gel Experimental e o BisBlock apresentaram efeitos estatisticamente semelhantes na redução da permeabilidade e foram significantemente mais eficientes que o Sensi Kill. Pode-se concluir que os agentes anti-hiperestésicos Experimental e BisBlock mostraram-se efetivos na redução da permeabilidade dentinária, pelos dois métodos de avaliação, e que o método de espectroscopia de impedância eletroquímica pode ser considerado um método alternativo para a avaliação da capacidade obstrutiva de agentes anti-hiperestésicos. / The aim of the present study was to quantify in vitro the dentin permeability of dentin treated with two potassium oxalate dentin desensitizers and one calcium phosphate agent through hydraulic conductance (Lp) and eletrochemical impedance spectroscopy (EIS) tests and, yet, to determine whether EIS may be considered a suitable alternative method to evaluate the occlusive capacity of the dentin desensitizers. For the hydraulic conductance, twenty-four dentin discs were obtained from extracted human third molars, which were divided into three groups of eight specimens, corresponding to the materials to be tested: Experimental gel, Sensi Kill and BisBlock. Other eighteen dentin discs were selected for theEIS and divided into three groups of six specimens corresponding to the three dentin desensitizers mentioned before. For both tests, the following conditions were measured: in the presence of smear layer, after 37% phosphoric acid etching and after the application of the tested materials in the occlusal surfaces of dentin discs. Based upon the statistical analysis of the results, it was demonstrated by both methods that Experimental gel and BisBlock performed statistically similarly in reducing dentin permeability and were significantly more efficient that Sensi Kill. It can be concluded that the dentin desensitizers Experimental e BisBlock were demonstrated to be effective in the reduction of dentin permeability by both experimental methods and that EIS may be considered as an alternative method for the evaluation of the obstructive capacity of dentin desensitizers.

Page generated in 0.0443 seconds