• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Efeito da desinfecção química e do envelhecimento acelerado sobre a, estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor de silicone para próteses faciais com distintas pigmentações

Pesqueira, Aldieris Alves [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 pesqueira_aa_me_araca.pdf: 540641 bytes, checksum: 5dfe2f80d73fb4a9cb52016d432619cf (MD5) / Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor, de um silicone facial, com distintas pigmentações, sob a influência da desinfecção e do envelhecimento acelerado. Para isso foram obtidos 60 corpos-de-prova, utilizando o silicone Silastic MDX 4- 4210, divididos em 3 grupos: sem pigmentação, pigmentado com pó de maquiagem e pigmentado com cerâmica. Metade dos corpos-de-prova de cada grupo foram submetidas à desinfecção com Efferdent e a outra metade com sabão neutro por 60 dias. Após esse período todos os corpos-de-prova (n=10) foram levados a uma câmara de envelhecimento acelerado para corpos não metálicos. Os ensaios de deterioração, estabilidade dimensional, reprodução e manutenção de detalhes, dureza Shore A e estabilidade de cor foram realizados após sua confecção, desinfecção e nos intervalos de cada ciclo de envelhecimento acelerado (252, 504 e 1008 horas). Os corpos-de-prova foram analisados, em computador pelo sistema AutoCAD para verificação da alteração dimensional linear e observados, em lupa estereoscópica para a análise da reprodução de detalhes. A dureza dos materiais foi analisada em durômetro Shore A e pesados em balança digital de precisão para análise da deterioração. A estabilidade de cor foi analisada por meio de espectrofotometria. Os valores encontrados dos testes de estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore a“ e estabilidade de cor foram submetidos à análise de variância e teste de Tukey em nível de 1% de probabilidade. Para a análise da reprodução e manutenção de detalhes foi utilizado escore. Pôde-se observar que os fatores desinfecção química e o envelhecimento acelerado influenciaram estatisticamente na deterioração, estabilidade dimensional, dureza... / The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details, Shore A hardness, deterioration and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated wheatering. 60 samples were obtained, using silicone Silastic MDX 4-4210, divided in 3 groups: nonpigmented, pigmented with make-up powder and pigmented with ceramics. The half of the samples of each group was submitted to the disinfection with Efferdent and another one with neutral soap per 60 days. After this period all the samples were taken to a chamber of accelerated wheatering for not metallic bodies (n=10). The tests of deterioration, dimensional stability, maintenance of the details, Shore A hardness and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated wheatering (252, 504 e 1008 horas). Samples were weighty in digital balance for analysis of deterioration. Analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. Materials hardness was analyzed in Shore A durometer and the color stability by means of spectrophotometer. The values had been submitted to the analysis of variance and Tukey test (1%). It can be observed that the factors: chemical disinfection and the accelerated wheatering had influenced statistically in deterioration, dimensional stability, Shore A hardness and color stability of the materials independently of the pigmented. With relation to the reproduction and maintenance of details, the values did not change independently of the pigmented, disinfection and accelerated wheatering.
252

Desinfecção de próteses totais por micro-ondas : efeito da frequência de irradiação no tratamento da estomatite protética /

Silva, Mariana Montenegro. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Elaine Maria Sgavioli Massucato / Banca: Helena de Freitas Oliveira Paranhos / Banca: Karin Hermana Neppelenbroek / Resumo: A estomatite protética é uma infecção fúngica que acomete entre 60% e 72% dos indivíduos portadores de próteses removíveis, sobretudo idosos do gênero feminino. Atualmente, a desinfecção de próteses totais por meio da irradiação por micro-ondas tem sido recomendada para tratamento e prevenção da estomatite protética. Considerando esses aspectos, esse estudo in vivo avaliou a efetividade da frequência da desinfecção de próteses totais por micro-ondas (3 min/650 W) em relação à terapia antifúngica tópica para o tratamento da estomatite protética, além de verificar a prevalência de Candida nos pacientes avaliados. Para isso, foram selecionados 60 indivíduos, portadores de próteses totais superiores e com diagnóstico clínico de estomatite protética. Esses pacientes foram aleatoriamente distribuídos em 3 grupos (n=20), de acordo com o tratamento instituído: Terapia Antifúngica Tópica (Grupo I) - utilização de nistatina (suspensão oral, 100.000 UI/mL), 4 vezes ao dia durante 15 dias; Irradiação por Micro-ondas - imersão das próteses totais em água e irradiação das próteses por micro-ondas durante 3 minutos a 650 W, 1 ou 3 vezes por semana (Grupos II e III, respectivamente) por um período de 15 dias. Para avaliação da efetividade dos tratamentos instituídos, foram realizadas culturas micológicas quantitativas e identificação das espécies de Candida, utilizando-se o meio CHROMagar Candida, análise de microcultivo, teste de triagem em caldo hipertônico e o sistema bioquímico de identificação ID 32C. Coletas de biofilme das superfícies internas das próteses totais superiores e das mucosas palatinas de todos os pacientes, foram realizadas previamente ao tratamento (dia 0) e após 15 dias do seu início. Com o objetivo de avaliar a efetividade dos tratamentos em longo prazo, a quantificação de colônias viáveis de Candiada spp... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Denture stomatitis is a fungal infection that affects 60% to 72% of individuals who use removable dentures, primarily elderly women. Currently, the disinfection of complete dentures using microwave irradiation has been recommended to treat and prevent denture stomatitis. Considering these aspects, this in vivo study evaluated the effectiveness of the frequency of complete denture disinfection using microwaves (3 min/650 W) compared to antifungal therapy for the treatment of denture stomatitis. It also verified the prevalence of Candida spp. in the evaluated patients. This study used a sample of 60 healthy individuals who use complete upper dentures and have received a clinical diagnosis of denture stomatitis. Patients were randomly distributed into three groups (n=20), based on the treatment used: Topical Antifungal Therapy (Group I) - use of nystatin (oral suspension, 100.000 UI/mL), four times a day for 15 days; Irradiation with Microwaves - irradiation of the dentures by microwaves for three minutes at 650 W, one time or three times per week (Groups II and III, respectively) for a period of 15 days. In order to evaluate the effectiveness of the treatments used, quantitative mycological cultures were collected and the Candida species were identified using the CHROMagar Candida method, microculture analysis, screening test in hypertonic broth and the ID 32C biochemical identification system. Biofilm samples were collected from the inner surfaces of the complete upper dentures and from the palatal mucosa of all patients before (day 0) and after 15 days of treatment. In order to evaluate the effectiveness of the treatments over the long term, the quantification of the viable Candiada spp. colonies was repeated 30, 60 and 90 days after starting the treatment. For each consultation (days 0, 15, 30, 60 and 90), a clinical evaluation was also performed through intra-oral photography... (Complete abstract click electronic access below) / Doutor
253

Avaliação da resistência térmica, ácida e a desinfetantes de cepas de Escherichia coli O157:H7 isoladas no sul do Brasil

Paula, Cheila Minéia Daniel de January 2014 (has links)
Escherichia coli O157:H7 é um dos patógenos alimentares mais importantes da atualidade, e, recentemente, diversas cepas desse microrganismo foram isoladas no sul do Brasil. O objetivo deste trabalho foi caracterizar duas cepas de E. coli O157:H7, através da avaliação de sua resistência térmica, ácida e comportamento frente a diferentes desinfetantes e procedimentos de higienização de vegetais folhosos. Resultados demonstraram a redução significativa das contagens bacterianas, após 3 minutos a 60ºC, 2 minutos a 65º, 1 minuto a 70, 72º C e 75ºC. Contudo, após adaptação ácida, nenhuma das cepas foi inativada a 60ºC, por até 3 minutos. A 70ºC foi observado aumento significativo da resistência térmica apenas para a CC. Em relação à resistência ácida, ambas as cepas sobreviveram quando expostas ao meio TSBm a diferentes pH entre 2,0 a 9,5 ajustados com ácido clorídrico e ácido propiônico (AP). Apenas, o meio com pH 2,0, ajustado com AP, foi capaz de reduzir significativamente às contagens de ambas as cepas. Na avaliação da resistência aos desinfetantes, álcool etílico (96ºGl e 70%) e quaternário de amônio foram capazes de inativar ambas as cepas, mesmo na presença de matéria orgânica. O ácido orgânico, na concentração recomendada pelo fabricante e o dobro dessa concentração, reduziu cerca de 90% das contagens, após 5 minutos de exposição. O dicloroisocianurato de sódio só apresentou reduções significativas quando foram utilizadas duas vezes a concentração recomendada pelo fabricante. Todos os procedimentos de lavagem e desinfecção de alfaces, artificialmente contaminadas com E. coli O157:H7, reduziram as contagens em 2,97±1,21logUFC/g, apenas o tratamento conduzido a 10ºC, diferiu significativamente dos demais, apresentando maior redução 6,27±0,50logUFC/g. Esses resultados demonstram que as cepas de E. coli O157:H7 foram resistentes a diferentes situações de estresse, sendo portanto importantes do ponto de vista epidemiológico, visto que estão presentes no sul do Brasil e podem se tornar agentes etiológicos de surtos alimentares. / Escherichia coli O157:H7 is a major food pathogens today, and recently, several strains of this organism were isolated in southern Brazil. The objective of this study was to characterize two strains of E. coli O157: H7, by evaluating its thermal and acid resistance and behavior among different disinfectants and cleaning procedures on leafy vegetables. The results showed a significant reduction in bacterial counts after 3 minutes at 60 ° C, 2 min at 65 ° and 1 min at 70, 72 º C and 75 º C. However, after acid adaptation, none of the strains was inactivated at 60 ° C among 3 minutes. At 70 ° C significant increase in heat resistance was observed only for CC. Regarding acid resistance, both strains survived when exposed to TSBm medium at different pH adjusted from 2.0 to 9.5 with hydrochloric acid and propionic acid (PA). Only when the medium was adjusted with AP at pH 2.0 it was able to significantly reduce the counts of both strains. Evaluating the resistance to disinfectants, Ethyl Alcohol Free (96ºGl and 70 %) and quaternary ammonium were able to inactivate both strains, even in the presence of organic matter. For the orgnic acid in the concentration recommended by the manufacturer and at the double concentration there was reduced around 90 % of the counts after 5 minutes of exposure. The sodium dichloroisocyanurate only showed significant reductions when used in the double concentration recommended by the manufacturer. All procedures for cleaning and disinfecting the lettuces artificially contaminated with E. coli O157 : H7 counts decreased by 2.97 ± 1.21 log CFU / g , only the treatment conducted at 10 ° C reduced significantly from the others (6 , 27 ± 0.50 log CFU / g). The results demonstrate that the strains of E. coli O157 : H7 were resistant to different stress situations and therefore are important as an epidemiological point of view, as it is present in southern Brazil and can become etiologic agents of food borne outbreaks.
254

Avaliação da resistência térmica, ácida e a desinfetantes de cepas de Escherichia coli O157:H7 isoladas no sul do Brasil

Paula, Cheila Minéia Daniel de January 2014 (has links)
Escherichia coli O157:H7 é um dos patógenos alimentares mais importantes da atualidade, e, recentemente, diversas cepas desse microrganismo foram isoladas no sul do Brasil. O objetivo deste trabalho foi caracterizar duas cepas de E. coli O157:H7, através da avaliação de sua resistência térmica, ácida e comportamento frente a diferentes desinfetantes e procedimentos de higienização de vegetais folhosos. Resultados demonstraram a redução significativa das contagens bacterianas, após 3 minutos a 60ºC, 2 minutos a 65º, 1 minuto a 70, 72º C e 75ºC. Contudo, após adaptação ácida, nenhuma das cepas foi inativada a 60ºC, por até 3 minutos. A 70ºC foi observado aumento significativo da resistência térmica apenas para a CC. Em relação à resistência ácida, ambas as cepas sobreviveram quando expostas ao meio TSBm a diferentes pH entre 2,0 a 9,5 ajustados com ácido clorídrico e ácido propiônico (AP). Apenas, o meio com pH 2,0, ajustado com AP, foi capaz de reduzir significativamente às contagens de ambas as cepas. Na avaliação da resistência aos desinfetantes, álcool etílico (96ºGl e 70%) e quaternário de amônio foram capazes de inativar ambas as cepas, mesmo na presença de matéria orgânica. O ácido orgânico, na concentração recomendada pelo fabricante e o dobro dessa concentração, reduziu cerca de 90% das contagens, após 5 minutos de exposição. O dicloroisocianurato de sódio só apresentou reduções significativas quando foram utilizadas duas vezes a concentração recomendada pelo fabricante. Todos os procedimentos de lavagem e desinfecção de alfaces, artificialmente contaminadas com E. coli O157:H7, reduziram as contagens em 2,97±1,21logUFC/g, apenas o tratamento conduzido a 10ºC, diferiu significativamente dos demais, apresentando maior redução 6,27±0,50logUFC/g. Esses resultados demonstram que as cepas de E. coli O157:H7 foram resistentes a diferentes situações de estresse, sendo portanto importantes do ponto de vista epidemiológico, visto que estão presentes no sul do Brasil e podem se tornar agentes etiológicos de surtos alimentares. / Escherichia coli O157:H7 is a major food pathogens today, and recently, several strains of this organism were isolated in southern Brazil. The objective of this study was to characterize two strains of E. coli O157: H7, by evaluating its thermal and acid resistance and behavior among different disinfectants and cleaning procedures on leafy vegetables. The results showed a significant reduction in bacterial counts after 3 minutes at 60 ° C, 2 min at 65 ° and 1 min at 70, 72 º C and 75 º C. However, after acid adaptation, none of the strains was inactivated at 60 ° C among 3 minutes. At 70 ° C significant increase in heat resistance was observed only for CC. Regarding acid resistance, both strains survived when exposed to TSBm medium at different pH adjusted from 2.0 to 9.5 with hydrochloric acid and propionic acid (PA). Only when the medium was adjusted with AP at pH 2.0 it was able to significantly reduce the counts of both strains. Evaluating the resistance to disinfectants, Ethyl Alcohol Free (96ºGl and 70 %) and quaternary ammonium were able to inactivate both strains, even in the presence of organic matter. For the orgnic acid in the concentration recommended by the manufacturer and at the double concentration there was reduced around 90 % of the counts after 5 minutes of exposure. The sodium dichloroisocyanurate only showed significant reductions when used in the double concentration recommended by the manufacturer. All procedures for cleaning and disinfecting the lettuces artificially contaminated with E. coli O157 : H7 counts decreased by 2.97 ± 1.21 log CFU / g , only the treatment conducted at 10 ° C reduced significantly from the others (6 , 27 ± 0.50 log CFU / g). The results demonstrate that the strains of E. coli O157 : H7 were resistant to different stress situations and therefore are important as an epidemiological point of view, as it is present in southern Brazil and can become etiologic agents of food borne outbreaks.
255

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas

Basso, Michael Frederico Manzolli [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 basso_mfm_dr_arafo.pdf: 618642 bytes, checksum: a30b4dfd3eaaae29f0c670dfb57dbd55 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... / Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below)
256

Influência de aplicações do laser érbio:YAG sobre a viabilidade microbiana, sua resistência a drogas e atividade hemolítica

Lopes, Angélica Marquezim [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T19:57:14Z : No. of bitstreams: 1 lopes_am_me_araca.pdf: 932429 bytes, checksum: 58f57b4ef355fad92340a3819101663b (MD5) / A atividade antimicrobiana do laser Er:YAG foi avaliada sobre biofilme bacteriano constituído por Escherichia coli ATCC 8739, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 6538 e 3 cepas de Fusobacterium nucleatum e sobre biofilme de microrganismos salivares. Os biofilmes foram submetidos à ação do laser a 1,2 W e 10 Hz por 5, 10, 15, 20, 30 e 60 s e fez-se a avaliação da microbiota residual em ágar sangue, em anaerobiose. O biofilme salivar se mostrou mais sensível nos primeiros tempos de irradiação. A redução microbiana em relação ao controle foi estatisticamente significativa entre todos os tempos testados. Avaliou-se também a ação do laser Er:YAG sobre 7 cepas de Fusobacterium nucleatum inoculadas sobre a superfície de corpos-de-prova (5mmX4mm) de dentes extraídos. Fez-se a aplicação do laser nos mesmos parâmetros físicos mencionados anteriormente, durante 15 s, levando à eliminação total do conteúdo séptico. O estudo avaliou também a irradiação do laser de Er:YAG durante tempos subinibitórios sobre a atividade hemolítica e susceptibilidade de 9 cepas de Fusobacterium nucleatum a amoxicilina, eritromicina, metronidazol e tetraciclina. Após a irradiação do laser, determinou-se a concentração inibitória mínima (CIM) para as drogas através do método de diluição em ágar. A ação do laser sobre a atividade hemolítica foi determinada em sangue humano. Verificou-se que o laser Er:YAG não afetou a atividade hemolítica de Fusobacterium nucleatum, que se mostrou α-hemolítica, tampouco a susceptibilidade a drogas dos isolados testados. / Antimicrobial activity of Er:YAG laser was evaluated on a bacterial biofilm constituted by Escherichia coli ATCC 8739, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 6538 and 3 strains of Fusobacterium nucleatum and on biofilm produced by salivary microorganisms. Biofilms were irradiated by Er:YAG laser, 1,2 W and 10 Hz, for 5, 10, 15, 20, 30, and 60 s and the evaluation of residual contamination was performed on blood agar, under anaerobiosis. It was verified that salivary biofilm showed to be more susceptibility to the Er:YAG laser in shorter periods of laser irradiation. Bacterial reduction was significative in all tested periods of irradiation. The activity of Er:YAG laser was also evaluated on 7 strains of Fusobacterium nucleatum inoculated on samples of human dentin (5mm X 4mm), obtained from extracted teeth. The laser was used following the same physical parameters, as previously described, for 15 s, leading to complete elimination of their septic content. The study also evaluated the effects of subinibitory irradiation of Er:YAG laser on bacterial susceptibility of 9 strains of Fusobacterium nucleatum to antimicrobial drugs (amoxicillin, erythromycin, metronidazole, tetracycline) and hemolysis. Thus, after laser irradiation, the minimal inhibitory concentration of antimicrobial drugs was determined by using an agar dilution method. The influence of laser on hemolysis was carried out on human blood. It was verified that Er:YAG laser did not produce any measurable effect on hemolytic activity and the microbial susceptibility to tested antimicrobial drugs.
257

Influência da rugosidade de superfície e ação de diferentes desinfetantes na formação de biofilme em resina acrílica para prótese ocular e sua biocompatibilidade em contato com células da conjuntiva humana / Influence of surface roughness and action of different disinfectants on the formation of biofilm in acrylic resin for ocular prosthesis and their biocompatibility in contact with cells human conjunctiva cells

Andreotti, Agda Marobo [UNESP] 31 August 2017 (has links)
Submitted by Agda Marobo Andreotti (36897500836) on 2017-10-19T21:29:31Z No. of bitstreams: 1 TESE DOUTORADO AGDA MAROBO ANDREOTTI.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-23T18:36:23Z (GMT) No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Made available in DSpace on 2017-10-23T18:36:23Z (GMT). No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) Previous issue date: 2017-08-31 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O controle da formação de biofilme é essencial para manter a saúde da cavidade anoftálmica dos portadores de prótese ocular. As propriedades físicas da resina acrílica, como a sua rugosidade, podem interferir na adesão de microrganismos nas próteses e na formação de biofilmes. Sendo assim, é necessário utilizar soluções de limpeza eficazes e que não causem irritação tecidual na conjuntiva ocular. O objetivo desse trabalho foi verificar a influência da rugosidade de superfície da resina acrílica utilizada na confecção de próteses oculares na formação de biofilme bacteriano, bem como avaliar a eficácia antimicrobiana e citotoxicidade de diferentes soluções para desinfecção de próteses oculares. Para a análise da rugosidade, corpos de prova de resina acrílica foram confeccionados e divididos em 5 grupos de acordo com a granulação de lixa de polimento utilizada: 120, 400, 800, 1200 e 1200S (lixa + sílica). A rugosidade dos corpos de prova foi mensurada por meio de perfilômetro e imagens de Microscopia de Força Atômica foram obtidas para cada grupo. O crescimento das espécies Staphylococcus aureus e Staphylococcus epidermidis sobre os corpos de prova foi avaliado após 4 e 24h, por meio da contagem das Unidades Formadoras de Colônia (UFC)/mL. O efeito dos seguintes tratamentos: soro fisiológico, sabão neutro, clorexidina 4%, pastilhas efervescentes Efferdent®, triclosan 1% e citronela sobre biofilme formado sobre os corpos de prova de resina acrílica também foi avaliado por meio da determinação do número de UFC/mL. A citotoxicidade dos agentes antimicrobianos foi avaliada por meio dos testes de MTT e Neutral Red, após tratamento dos corpos de prova, diariamente, por 1, 7, 15, 30, 60 e 90 dias com as soluções já citadas, sendo avaliados ao fim de cada período. Os dados obtidos foram submetidos à análise estatística adequada, considerando se provinham de dados paramétricos ou não paramétricos. Os resultados demonstraram que os menores valores de rugosidade foram encontrados no grupo 800, 1200 e 1200S. A contagem microbiana foi menor no grupo 1200S e esta diferiu estatisticamente (p>0,05) do controle para ambos os tempos de avaliação e bactérias. Na análise da ação antimicrobiana das soluções para desinfecção, todos os protocolos promoveram redução do crescimento dos microrganismos testados comparados ao controle (crescimento sem a presença do antimicrobiano), sendo que os grupos submetidos ao tratamento com clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% eliminaram o biofilme (p>0,01). Ainda nos ensaios de citotoxicidade, em todos os grupos foi observada proliferação celular das células da conjuntiva acima de 84% (p>0,05). Dessa forma, conclui-se que a rugosidade não interfere significativamente na adesão bacteriana e formação de biofilme, exceto para o grupo 1200S, e que os protocolos de limpeza com imersão em clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% são totalmente eficazes na desinfecção e não apresentam citotoxicidade para com as células da conjuntiva humana, sugerindo sua indicação para desinfecção de próteses oculares. / The control of biofilm formation is essential to maintain the health of anophthalmic cavity of ocular prosthesis wearers. The physical properties of the acrylic resin, such as surface roughness, may interfere with the adhesion of microorganisms to the prostheses. Therefore, it is necessary to use cleaning solutions that are effective and do not cause tissue irritation in ocular conjunctiva. The aim of this study was to verify the influence of surface roughness of the acrylic resin used in the preparation of ocular prosthesis in the formation of bacterial biofilm, as well as to evaluate the antimicrobial efficacy and cytotoxicity of different disinfectants in ocular prostheses. For roughness analysis, acrylic resin samples were prepared and divided into 5 groups according to the granulation of polishing sandpaper used: 120, 400, 800, 1200 and 1200S (sandpaper + silica). The roughness of the samples was measured using a profilometer and Atomic Force Microscopy images were obtained for each group. The microbial growth for Staphylococcus aureus and Staphylococcus epidermidis on the samples was evaluated after 4 and 24 h by counting the Colony Forming Units (CFU)/mL. The effect of the following solutions was also evaluated by CFU/mL: non treated group (immersed in saline solution), neutral soap, 4% chlorhexidine, Efferdent® effervescent tablets, 1% triclosan and citronella. The cytotoxicity of the solutions was evaluated by MTT and Neutral Red after treating the samples daily for 1, 7, 15, 30, 60 and 90 days with the solutions already mentioned, being evaluated at the end of each period. Data were submitted to proper statistical analysis, considering whether data were parametric or non-parametric. The results showed that the lowest roughness values were found in groups 800, 1200 and 1200S. 1200S group also presented the lowest values of microbial growth statistically different from control group (p>0,05), for both periods and bacteria evaluated. In the analysis of the solutions, compared to the control group (microbial growth without the presence of the antimicrobial), all protocols promoted a reduction in the growth of the microorganisms, and the groups submitted to disinfection with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan eliminated the biofilm (p>0,01). In addition, all groups showed cell proliferation of conjunctival cells above 84% in the cytotoxicity assays (p>0,05). Thus, it was concluded that the roughness does not significantly interfere in the adhesion of the microorganisms, except for group 1200S, and that the cleaning protocols with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan are totally effective in the disinfection and do not present cytoxicitiy with human conjunctive cells, what suggests their indication for cleaning of ocular prosthesis. / CNPq: 141722/2015-0
258

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese /

Seó, Rosangela Seiko. January 2006 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Banca: Rodrigues Nunes Rached / Resumo: O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / Abstract: This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection. / Doutor
259

Higienização das viaturas móveis de atendimento pré-hospitalar:intervenção educativa / Cleaning of ambulances of the pre hospital care: an educational intervention

Karina Suzuki 28 September 2015 (has links)
Discussões sobre prevenção e controle de Infecção Relacionada à Assistência à Saúde (IRAS) deve ser irrestrita e ampliada a outros estabelecimentos de saúde. A literatura sobre controle de infecção é tradicionalmente fundamentada na prática do contexto hospitalar, e há uma lacuna quando se trata de atendimento pré-hospitalar. Além dos profissionais da área saúde, outros profissionais compõem a equipe entre eles, bombeiros e policiais militares, rodoviários e outros, que não tiveram em sua formação profissional conteúdo específico que lhes fornecesse conhecimento sobre a prevenção e o controle de infecções nas situações de atendimento a vítimas com potencial risco de contaminação por fluidos biológicos, sendo a educação, portanto, a arma contra a disseminação de doenças infecciosas. Objetivo: avaliar a eficácia de uma intervenção educativa utilizando mapas conceituais e indicadores de conformidade para higienização das viaturas móveis do Atendimento Pré-Hospitalar de uma capital da região centro-oeste do Brasil. Método: Estudo de natureza quantitativa, quase-experimental, a coleta de dados foi de julho de 2014 a janeiro de 2015. Participaram do estudo 34 bombeiros do Batalhão de Salvamento em Emergência (BSE) do Corpo de Bombeiros Militar do Estado de Goiás (CBMGO) que atuam nas viaturas de suporte básico e avançado de vida. O estudo foi desenvolvido em quatro fases: Elaboração e validação de conteúdo do indicador de conformidade para higienização das viaturas; Avaliação da conformidade da higienização das viaturas antes da capacitação; Intervenção Educativa e Avaliação da conformidade da higienização das viaturas após intervenção. Foi aplicado um questionário antes da intervenção e 30 dias depois. Os indicadores de conformidade foram validados por um corpo de oito juízes com cálculo do Índice de Validade de Conteúdo (IVC 70%). A avaliação da eficácia da capacitação foi feita pelo teste de McNemar, sendo considerado p 0,05. A capacitação dos profissionais foi baseada na teoria da aprendizagem significativa de David Ausubel e da construção de um mapa conceitual idealizado por Joseph Novak. Resultados: Dos 71 indicadores de conformidade, foram excluídos 26, totalizando 45 indicadores. Na avaliação pré-intervenção, somente um (2,9%) socorrista sabia definir limpeza, quatro (11,8%) sabiam o conceito de desinfecção, 14 (41,2%) sabiam da importância de se higienizar a viatura e do uso de EPI. Após intervenção no total três (8,8%) bombeiros sabiam conceituar limpeza, cinco (14,7%), desinfecção, quanto à importância da limpeza e desinfecção 16 (47,1%) e em relação à importância do uso de EPI foram 15 (44,1%) A observação do procedimento de higienização melhorou quanto aos parâmetros de secagem da viatura após a lavagem (p=0,004) e desinfecção da viatura (p=0,002). Os dados mostram que após o curso teve uma ligeira melhora no número de questões corretas, sendo estatisticamente significativa (p=0,021). Conclusão: a intervenção educativa utilizando uma metodologia ativa com a construção de mapas conceituais não se mostrou totalmente eficaz. A observação dos procedimentos de higienização das viaturas manteve-se no mesmo padrão, exceto para secagem e desinfecção; os bombeiros socorristas não melhoraram o conhecimento da definição de limpeza e desinfecção e o entendimento da importância de se higienizar a viatura e o uso de EPIs. / Discussions on prevention and control of infection Related to Health Care (IRHC) should be unrestricted and expanded to other health care facilities. The literature on infection control is traditionally based on the practice of hospital context, and there is a gap when it comes to pre-hospital care. In addition to health care professionals, other professionals make up the team, firefighters, police officers and others who have not taken their training specific content to provide them with knowledge about prevention and control of infections in situations with potential risk of contamination by biological fluids, therefore, education is the weapon against the spread of infectious diseases. Objective: To evaluate the effectiveness of an educational intervention using concept maps and compliance indicators for cleaning of mobile cars of Prehospital care from a capital of the midwestern region of Brazil. Method: quantitative study, quasi-experimental, data collection was from July 2014 to January 2015. The study included 34 firefighters Rescue Battalion Emergency (BSE) of the Fire Brigade of the State of Goiás working in basic and advanced life support vehicles. The study was developed in four phases: Development and content validity of compliance indicator for cleaning of vehicles; Conformity assessment of the cleaning of vehicles before training; Educational Intervention and Conformity assessment of the cleaning of vehicles after intervention. A questionnaire was applied before the intervention and 30 days after. Compliance indicators were validated by an 8 experts judge with Content Validity Index (IVC 70%). The evaluation of training effectiveness was taken by McNemar test, being considered p 0.05. The training of professionals was based on the theory of meaningful learning of David Ausubel and the construction of a conceptual map designed by Joseph Novak. The data show that after the course there was a slight improvement in the number of correct questions, being statistically significant (p = 0.021) and that the course brought a homogenization knowledge given to reducing the standard deviation. Results: Of the 71 indicators of compliance, 26 were excluded, totaling 45 indicators.The pre-intervention assessment, only one (2.9%) rescuer knew cleaning definition, four (11.8%) knew the concept of disinfection, 14 (41.2%) knew the importance of sanitize the vehicle and the use of PPE. After intervention a total of three (8.8%) firefighters knew conceptualize cleanliness, five (14.7%), disinfection, on the importance of cleaning and disinfection 16 (47.1%) and of the importance of the use of PPE were 15 (44.1%). The observation of the cleaning procedure improved regarding these parameters drying after washing (p=0,004) and disinfection of the vehicle (p=0,002) Conclusion: The educational intervention using an active methodology and the construction of conceptual maps was not fully effective. The observation of the vehicles cleaning procedures remained the same pattern, except for drying and disinfecting rescuers firefighters have not improved the knowledge of the definition of cleaning and disinfection and understanding of the importance of sanitizing the vehicle and the use of PPE.
260

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Silvia Cristina Mafra Cecchini 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.

Page generated in 0.0776 seconds