• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 72
  • 1
  • Tagged with
  • 74
  • 53
  • 12
  • 11
  • 9
  • 9
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Extrusão de debris, desvio apical, capacidade de centralização e área de desgaste promovidos por instrumentos rotatórios e reciprocantes indicados para canais amplos

Costa, Elielton Lima 09 March 2016 (has links)
Submitted by Izabel Monteiro (izabel_22@hotmail.com) on 2016-06-17T13:48:46Z No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-23T20:16:09Z (GMT) No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-23T20:21:23Z (GMT) No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Made available in DSpace on 2016-06-23T20:21:23Z (GMT). No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) Previous issue date: 2016-03-09 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The aim of the study was to evaluate the extrusion of debris, apical transportation, centering ability and wear area further by Rotary and reciprocating instruments used in large root canals. Forty-five mandibular premolar with only single-rooted teeth and single canal and apical diameter largest that 300 μm. In order of the standardization the samples were fixed in acrylic resin and placed in styrofoam platform. Cone-beam computed tomography analysis was perfomed before and after instrumentation for apical third images acquisition for to appoint the anatomic and surgical diameter. The extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions. Group 1 (Protaper Universal - PTU): All PTU instruments were used to the full length of the canals according to the manufacturer’s instructions using a gentle in-and-out motion. The instrumentation sequence was S1, S2, F1, F2, F3, F4 and F5. Group 2 (Protaper Next - PTN): All PTN instruments were used to the full length of the canals according to the manufacturer’s instructions using a gentle in-and-out motion. The instrumentation sequence was X1, X2, X3, X4 and X5. Group 3 (Reciproc R50 – R50): Reciproc file was used in a reciprocating, slow in-and-out pecking motion according to the manufacturer’s instructions. The flutes of the instrument were cleaned after 3 in-and-outmovements (pecks). In each sample, a total of 1-mL distilled water was used as the irrigant solution between files. Before weighing the dry debris, the tubes were stored in na incubator at 70 °C for 5 days to evaporate the distilled water. The quantitative evaluation of apically extrued debris was analyzed by weight difference before and after instrumentation. Apical transportation, centering ability and wear area were analyzed for images of the cone-beam computed tomography worked in the software OsiriX. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test). The results showed that the group PTN produced significantly more debris compared with both groups (P<0.01). All groups had apical transportation values in the 2°, 3° e 4° mm apical, with no significant difference among them (P>0.05). No technique had perfect centering abitity (=1.0). the group R50 showed largest wear area, with significant difference (P<0.05) compared with both groups. In conclusion, under the condition of this study, the group PTN produced more debris compared with both groups. The R50 intrumentation showed largest wear area that both Group PTN and PTU, with significant difference. All technique showed no had perfect centering abitity and showed apical transportation, no with significant difference between them. / O objetivo do presente trabalho foi avaliar o extravasamento apical de debris, desvio apical, capacidade de centralização e área de desgaste promovidos por sistemas de instrumentação rotatórios e reciprocante indicados para canais amplos. Foram selecionados 45 pré-molares inferiores com único canal e raiz e diâmetro apical maior que 300 μm. Com intuito de padronização das amostras fixou-se os espécimes em base de resina acrílica e posicionou-os em plataforma de isopor. Os espécimes foram submetidos a tomografia computadorizada antes e após a instrumentação para determinação do diâmetro anatômico e cirúrgico a fim de favorecer as mensurações do estudo. Durante a instrumentação os dentes foram fixados em frascos de vidro para a pesagem dos debris apicais. Os dentes selecionados foram distribuídos em três grupos (n=15) e instrumentados de acordo com as indicações dos respectivos fabricantes dos sistemas. Grupo I (Protaper Universal - PTU): todos os instrumentos, S1, S2, F1, F2, F3, F4 e F5, foram inseridos no comprimento de trabalho real com avanço progressivo e movimentos de vai e vem no interior dos canais. Grupo II (Protaper Next - PTN): instrumentos X1, X2, X3, X4, X5 foram inseridos no comprimento de trabalho real com avanço progressivo e movimentos de vai e vem no interior dos canais. Grupo III (Reciproc – R50): Reciproc R50 foi inserido progressivamente no canal, inseria-se e removia-se o instrumentos e limpava-o com gaze. Esse procedimento foi repetido até o alcance do comprimento de trabalho, em três avanços. Utilizou-se 1 mL de água bidestilada como solução irrigante a cada troca de instrumento. Os frascos de vidro contendo debris foram armazenados em estufa a 70 °C por 5 dias até a secagem completa da água. Determinou-se a quantidade de debris pelo cálculo da diferença dos pesos iniciais e finais dos frascos. As imagens tomográficas foram manipuladas no programa OsiriX a fim de se determinar o desvio apical, capacidade de centralização e área de desgaste. Os dados foram submetidos ao teste não-paramétrico de Kruskal-Wallis e teste de Múltiplas Comparações de Dunn. Os resultados do extravasamento de debris mostraram que o grupo da PTN apresentou maior quantidade de extravasamento, com diferença estatisticamente significante (P<0.01) em relação aos outros grupos. Todas as técnicas apresentaram desvio apical nos 2°, 3° e 4° milímetros apicais, porém sem diferença estatística significante (P>0.05). Nenhuma técnica apresentou centralização perfeita (=1.0). O grupo da R50 apresentou maior área de desgaste, com diferença estatisticamente significante (P<0.05) em relação ao demais grupos. Com base na metodologia empregada e nos resultados obtidos, concluiu-se que o sistema PTN apresentou estatisticamente maior quantidade de extravasamento de debris quando comparado aos demais grupos. O grupo R50 apresentou maior área de desgaste que os grupos PTN e PTU com diferença estatística significativa. Todas as técnicas tiveram tendência a centralização e apresentaram desvio apical, porém sem diferenças estatísticas entre si.
22

Estudo de transistores de tunelamento induzido por efeito de campo (TFET) construídos em nanofio. / Study of nanowire tunneling field effect transistors (TFET).

Sivieri, Victor De Bodt 26 February 2016 (has links)
Esse trabalho de mestrado teve como estudo o transistor Túnel-FET (TFET) fabricado em estrutura de nanofio de silício. Este estudo foi feito de forma teórica (simulação numérica) e experimental. Foram estudadas as principais características digitais e analógicas do dispositivo e seu potencial para uso em circuitos integrados avançados para a próxima década. A análise foi feita através da extração experimental e estudo dos principais parâmetros do dispositivo, tais como inclinação de sublimiar, transcondutância (gm), condutância de saída (gd), ganho intrínseco de tensão (AV) e eficiência do transistor. As medidas experimentais foram comparadas com os resultados obtidos pela simulação. Através do uso de diferentes parâmetros de ajuste e modelos de simulação, justificou-se o comportamento do dispositivo observado experimentalmente. Durante a execução deste trabalho estudou-se a influência da escolha do material de fonte no desempenho do dispositivo, bem como o impacto do diâmetro do nanofio nos principais parâmetros analógicos do transistor. Os dispositivos compostos por fonte de SiGe apresentaram valores maiores de gm e gd do que aqueles compostos por fonte de silício. A diferença percentual entre os valores de transcondutância para os diferentes materiais de fonte variou de 43% a 96%, sendo dependente do método utilizado para comparação, e a diferença percentual entre os valores de condutância de saída variou de 38% a 91%. Observou-se também uma degradação no valor de AV com a redução do diâmetro do nanofio. O ganho calculado a partir das medidas experimentais para o dispositivo com diâmetro de 50 nm é aproximadamente 45% menor do que o correspondente ao diâmetro de 110 nm. Adicionalmente estudou-se o impacto do diâmetro considerando diferentes polarizações de porta (VG) e concluiu-se que os TFETs apresentam melhor desempenho para baixos valores de VG (houve uma redução de aproximadamente 88% no valor de AV com o aumento da tensão de porta de 1,25 V para 1,9 V). A sobreposição entre porta e fonte e o perfil de dopantes na junção de tunelamento também foram analisados a fim de compreender qual combinação dessas características resultariam em um melhor desempenho do dispositivo. Observou-se que os melhores resultados estavam associados a um alinhamento entre o eletrodo de porta e a junção entre fonte e canal e a um perfil abrupto de dopantes na junção. Por fim comparou-se a tecnologia MOS com o TFET, obtendo-se como resultado um maior valor de AV (maior do que 40 dB) para o TFET. / This Master thesis focused in the study of the NW-TFET. The study was performed either by simulation as by experimental measurements. The main digital and analog characteristics of the device and its potential for use in advanced integrated circuits for the next decade were studied. The analysis was performed by extracting and studying the devices main parameters, such as subthreshold swing, transconductance (gm), output conductance (gd), intrinsic voltage gain (AV) and transistor efficiency. The experimental measurements were compared with the results obtained by simulation. Utilizing different simulation fitting parameters and models, the device behavior (observed in the experimental measurements) was understood and explained. During the execution of this work, either the influence of the source material on the device performance, as the impact of the nanowire diameter on the transistor main analog parameters, were studied. The devices with SiGe source presented higher values of gm and gd than those with silicon source. The percentual difference among the values of transconductance for the different source materials varied from 43% to 96%, being dependent on the method utilized for the comparison, and the percentual difference among the values of output conductance varied from 38% to 91%. A degradation of AV was also observed with the nanowire diameter reduction. The gain calculated from the experimental measurements for the device with 50 nm of diameter is approximately 57% lower than the gain corresponding to the diameter of 110 nm. Furthermore, the impact of the diameter considering different gate biases (VG) was analysed. It was concluded that TFETs show improved performance for lower values of VG (a reduction of approximately 88% of AV was observed for an increase of the gate voltage from 1.25 V to 1.9 V). The gate/source overlap length and the dopant profile at the tunneling junction were also analyzed in order to understand which combination of this features would result in a better performance of the device. It was observed that the best results were related to an alignment between the gate electrode and the source/channel junction and to an abrupt dopant profile at the junction. Finally, the MOS technology was compared with TFET, resulting in a higher AV (higher than 40 dB) for the TFET.
23

Análise preditiva da resistência à deflexão dos instrumentos rotatórios de NiTi em diferentes diâmetros nominais, conicidades e temperaturas. / Predicted analyze of the resistance to the deflection of the NiTi rotary instruments in different nominal diameters, taper and temperatures.

Barbosa, Luciana Aparecida Pereira 17 March 2008 (has links)
O objetivo deste trabalho foi avaliar a resistência à deflexão dos instrumentos endodônticos rotatórios K3 SybronEndo, de vários diâmetros nominais - padrão ISO - e diferentes conicidades, .02, .04 e .06. Avaliar se as alterações de temperatura de 25°C (ambiente) para 37°C (corpórea) e uma baixa temperatura 0°C influenciam de maneira significante na resistência à deflexão dos mesmos; e por último estabelecer uma equação para prever o comportamento desses instrumentos em relação a sua resistência à deflexão em diferentes ângulos de curvaturas. Foram utilizados cinco instrumentos K3 nos diâmetros nominais: #15, 20, 25, 30, 35, 40 e 45 nas três conicidades: .06, .04, .02 totalizando 105 instrumentos que foram submetidos a um teste de deflexão numa máquina universal, onde se avaliou a resistência à deflexão destes instrumentos de 0° (instrumentos sem deflexão, reto) até um ângulo de deflexão de 16° nas três diferentes temperaturas: 27°C, 37°C e 0°C. Foram obtidos resultados onde a resistência à deflexão dos instrumentos não foi influenciada de modo significante nas alterações de temperatura analisadas e não seguem um padrão linear. O diâmetro nominal e principalmente a conicidade (taper) dos instrumentos influenciam de maneira significante na resistência à deflexão dos mesmos. Um teste de regressão linear por função polinomial de primeiro grau indicou que esses instrumentos apresentavam uma resistência à deflexão que segue um padrão linear, e pôde ser predito através da seguinte equação: RD = a + bx onde se é possível calcular a resistência à deflexão de um instrumento em um determinado ângulo de curvatura do canal radicular. / The aim of this work was to evaluate the resistance to the deflection of the SybronEndo K3 NiTi rotary instruments in relation to the nominal diameter standard ISO in the three tapers: .06, .04, .02; to evaluate if the temperature changes of 25°C (room temperature) to 37°C (body temperature) and a low temperature 0°C influence the resistance to the deflection of these instruments in a significant way; and at last, to establish an equation to foresee the behaviour of these instruments in relation to their resistance to the deflection in different angles of curvatures. Five K3 instruments were used in the nominal diameters: #15, 20, 25, 30, 35, 40, and 45 in the three tapers: .06, .04, .02 adding up 105 instruments, which were subjected to an deflection test in an universal machine, where it was evaluated the resistance to the deflection of these instruments of 0° (instruments without deflection, straight) until a angle of deflection of 16° in the three different temperatures: 27°C, 37°C and 0°C. It was obtained a result where the resistance to the deflection of the instruments was not influenced, in significant way, the analyzed temperature changes, and they do not follow a linear standard. The nominal diameter and mainly the taper of the instruments influence, in significant way, the Abstract resistance to the deflection of them. A linear regression test for polynomial function of first degree indicated that these instruments presented a resistance to the deflection that follows a linear standard, and it could be predicted through the equation: RD = a + bx where it is possible to calculate the resistance to the deflection of an instrument in a determinate angle of curvature of root canal.
24

Relação hipsométrica de eucalipto clonal no sul do Tocantins

Schmitt, Thaís 14 September 2017 (has links)
Este trabalho foi estruturado em dois capítulos, utilizando 11 parcelas retangulares e permanentes de 348 m² cada, de um plantio clonal de Eucalyptus camaldulensis e Eucalyptus urophylla na região Sul do Estado do Tocantins. O primeiro capítulo objetivou a melhor forma de ajuste de modelos hipsométricos, analisando a acurácia do melhor modelo, e aplicando-o em uma situação florestal diferente. Os dados foram divididos em um lote de ajuste e outro de aplicação, com três classes de diâmetro e três classes de altura dominante. Inicialmente determinou-se o coeficiente de determinação ajustado em porcentagem (R²aj), erro-padrão da estimativa em porcentagem (Syx%), e análise gráfica residual. Posteriormente realizou-se um teste de identidade de modelos, seguido de um delineamento inteiramente casualizado (DIC) no esquema de parcelas subdivididas, juntamente com o teste de Dunnet. No final da análise, para avaliar a estabilidade dos modelos em um teste de validação, foram utilizados os critérios: coeficiente de determinação da predição (R²), soma de quadrados do resíduo relativo (SQRR), raiz quadrada do erro médio (RQEM), erro médio percentual (EMP). Concluiu-se que a melhor forma de ajuste foi realizar um ajuste por classe, sendo o modelo regional o mais adequado a se utilizar. O segundo capítulo aborda a avaliação de modelos hipsométricos aplicando a técnica de validação cruzada, e a comparação dos resultados com aqueles obtidos no capítulo 1, visando obter o melhor modelo a ser utilizado na região sob diferentes aspectos de seleção. Inicialmente aplicaram-se os critérios de precisão: coeficiente de determinação ajustado, erro padrão da estimativa e análise gráfica residual. Em seguida foram aplicados os critérios de estabilidade realizando a validação cruzada entre os dois lotes de dados, que foram estes: erro médio absoluto, raiz do quadrado médio e soma de quadrados do erro médio. Os modelos selecionados foram submetidos a uma nova análise, utilizando-se os lotes de dados do capítulo 1, onde se aplicou os mesmos critérios de precisão e estabilidade utilizados anteriormente, resultando na comparação entre os capítulos. Concluiu-se que o melhor modelo local foi o 14 de Chapman-Richards, o melhor modelo regional foi o parabólico 03, e na comparação com os modelos selecionados no capítulo 01, o mais adequado para o plantio foi o modelo regional parabólico 3, proveniente do capítulo 02. / Hypsometric relations of clonal eucalyptus in south of Tocantins. This work was structured in two chapters, using 11 rectangular and permanent plots of 348 m² each, from a clonal plantation of Eucalyptus camaldulensis and Eucalyptus urophylla in the southern region of the state of Tocantins. The first chapter aimed at the best way of adjusting hypsometric models, analyzing the accuracy of the best model, and applying it in a different forest situation. The data were divided into one set of adjustment and another of application, with three classes of diameter and three classes of dominant height. The coefficient of determination adjusted in percentage (R²aj), standard error of the estimate in percentage (Syx%), and residual graphical analysis were determined initially. A model identity test was then performed, followed by a completely randomized design (DIC) in the subdivided plot scheme, along with the Dunnet test. At the end of the analysis, to evaluate the stability of the models in a validation test, the following criteria were used: prediction determination coefficient (R²), sum of squares of the residual residue (SQRR), square root mean error (RQEM) mean error (EMP). It was concluded that the best form of adjustment was to perform an adjustment by class, being the regional model the most appropriate to be used. The second chapter deals with the evaluation of hypsometric models applying the cross validation technique, and the comparison of the results with those obtained in chapter 1, aiming to obtain the best model to be used in the region under different aspects of selection. Initially the precision criteria were applied: adjusted coefficient of determination, standard error of the estimate and residual graphical analysis. Then, the stability criteria were applied by performing cross-validation between the two batches of data, which were: absolute mean error, mean square root, and mean square error sum. The selected models were submitted to a new analysis, using the data bundles of chapter 1, where the same criteria of precision and stability previously used were applied, resulting in the comparison between the chapters. It was concluded that the best local model was Chapman-Richards 14, the best regional model was parabolic 03, and in comparison with the models selected in chapter 01, the most suitable for planting was the regional parabolic model 3, of chapter 02.
25

Gastrosquise fetal isolada: relação entre dilatação intestinal e resultados perinatais adversos / Isolated fetal gastroschisis: relation between bowel dilation and adverse perinatal outcome

Luciana de Freitas Garcia 30 November 2011 (has links)
Objetivos: Este estudo foi desenvolvido para avaliar o diâmetro transverso da alça intestinal exteriorizada como fator preditor de resultado adverso, nas gestações com gastrosquise fetal isolada. Métodos: Estudo retrospectivo envolvendo 94 gestações únicas. Foi realizada a medida do diâmetro transverso da alça intestinal (DTA) herniada, por meio da ultrassonografia antenatal, até 3 semanas antes do parto. Foi considerado resultado perinatal adverso: óbito intra-útero, óbito neonatal e complicações intestinais. Resultados: a última medida ultrassonográfica do DTA foi realizada com 35,6 ± 1,6 semanas e o tempo médio do intervalo entre a última medida e o parto foi de 6,2 ± 5,0 dias. Ocorreram 10 (10,6%) casos de óbitos intraútero e neonatal; foram observadas complicações intestinais em 8 (8,5%) casos. DTA 15, 20, 25 e 30 mm foram identificadas em 87, 46, 13 e 4% das gestações com prognóstico favorável, respectivamente. O DTA 25 mm apresentou valores de sensibilidade de 38%, e, valores preditivo positivo e preditivo negativo de 38% e 87%, na predição de resultados adversos. Para o DTA 30 mm, os valores foram: 19, 50 e 85%. A área sob a curva ROC do valor observado/esperado do DTA para cada idade gestacional foi de 0,67, sendo o melhor ponto-de-corte em 1,39; e, seus valores preditivos foram semelhantes aos do DTA 25 mm. Dilatação intestinal esteve significantemente associada com baixa taxa de fechamento primário da parede abdominal, longo período para iniciar a dieta via oral e internação hospitalar prolongada. Conclusões: Dilatação intestinal demonstrada até 3 semanas antes do parto é preditora de complicações intestinais e está associado a baixa taxa de fechamento primário da parede abdominal, longo período para iniciar a dieta via oral e de internação hospitalar / Objectives: Evaluate bowel diameter as a predictor of adverse outcome in isolated fetal gastroschisis. Methods: Retrospective study involving 94 singleton pregnancies. Ultrasound measurements of herniated bowel transverse diameter (BTD) were performed up to 3 weeks before delivery. Adverse outcome was intrauterine/ neonatal death and/or bowel complications. Results: Last BTD was recorded at 35,6 ± 1,6 weeks and mean interval to delivery was 6,2 ± 5,0 days. Intrauterine/ neonatal death occurred in 10 (10,6%) cases; bowel complications were observed in 8 (8,5%). BTD 15, 20, 25 and 30mm were found in 87, 46, 13 and 4% of pregnancies with a favorable outcome, respectively. BTD 25 mm sensitivity was 38%, positive and negative predictive values, 38% and 87%. For BTD 30 mm, the values were: 19, 50 and 85%. Observed/expected BTD ROC curve showed an area of 0,67, with best cut-off at 1,39; prediction values were similar to those for BTD 25 mm. Bowel dilatation was also significantly associated with lower rate of primary surgical closure, longer period to full oral feeding and prolonged hospital stay. Conclusions: Bowel dilatation demonstrated up to 3 weeks before delivery is a predictor of intestinal complications and is associated with lower rate of primary surgical closure, longer period to achieve full oral feeding and hospital stay
26

Análise preditiva da resistência à deflexão dos instrumentos rotatórios de NiTi em diferentes diâmetros nominais, conicidades e temperaturas. / Predicted analyze of the resistance to the deflection of the NiTi rotary instruments in different nominal diameters, taper and temperatures.

Luciana Aparecida Pereira Barbosa 17 March 2008 (has links)
O objetivo deste trabalho foi avaliar a resistência à deflexão dos instrumentos endodônticos rotatórios K3 SybronEndo, de vários diâmetros nominais - padrão ISO - e diferentes conicidades, .02, .04 e .06. Avaliar se as alterações de temperatura de 25°C (ambiente) para 37°C (corpórea) e uma baixa temperatura 0°C influenciam de maneira significante na resistência à deflexão dos mesmos; e por último estabelecer uma equação para prever o comportamento desses instrumentos em relação a sua resistência à deflexão em diferentes ângulos de curvaturas. Foram utilizados cinco instrumentos K3 nos diâmetros nominais: #15, 20, 25, 30, 35, 40 e 45 nas três conicidades: .06, .04, .02 totalizando 105 instrumentos que foram submetidos a um teste de deflexão numa máquina universal, onde se avaliou a resistência à deflexão destes instrumentos de 0° (instrumentos sem deflexão, reto) até um ângulo de deflexão de 16° nas três diferentes temperaturas: 27°C, 37°C e 0°C. Foram obtidos resultados onde a resistência à deflexão dos instrumentos não foi influenciada de modo significante nas alterações de temperatura analisadas e não seguem um padrão linear. O diâmetro nominal e principalmente a conicidade (taper) dos instrumentos influenciam de maneira significante na resistência à deflexão dos mesmos. Um teste de regressão linear por função polinomial de primeiro grau indicou que esses instrumentos apresentavam uma resistência à deflexão que segue um padrão linear, e pôde ser predito através da seguinte equação: RD = a + bx onde se é possível calcular a resistência à deflexão de um instrumento em um determinado ângulo de curvatura do canal radicular. / The aim of this work was to evaluate the resistance to the deflection of the SybronEndo K3 NiTi rotary instruments in relation to the nominal diameter standard ISO in the three tapers: .06, .04, .02; to evaluate if the temperature changes of 25°C (room temperature) to 37°C (body temperature) and a low temperature 0°C influence the resistance to the deflection of these instruments in a significant way; and at last, to establish an equation to foresee the behaviour of these instruments in relation to their resistance to the deflection in different angles of curvatures. Five K3 instruments were used in the nominal diameters: #15, 20, 25, 30, 35, 40, and 45 in the three tapers: .06, .04, .02 adding up 105 instruments, which were subjected to an deflection test in an universal machine, where it was evaluated the resistance to the deflection of these instruments of 0° (instruments without deflection, straight) until a angle of deflection of 16° in the three different temperatures: 27°C, 37°C and 0°C. It was obtained a result where the resistance to the deflection of the instruments was not influenced, in significant way, the analyzed temperature changes, and they do not follow a linear standard. The nominal diameter and mainly the taper of the instruments influence, in significant way, the Abstract resistance to the deflection of them. A linear regression test for polynomial function of first degree indicated that these instruments presented a resistance to the deflection that follows a linear standard, and it could be predicted through the equation: RD = a + bx where it is possible to calculate the resistance to the deflection of an instrument in a determinate angle of curvature of root canal.
27

Gastrosquise fetal isolada: relação entre dilatação intestinal e resultados perinatais adversos / Isolated fetal gastroschisis: relation between bowel dilation and adverse perinatal outcome

Garcia, Luciana de Freitas 30 November 2011 (has links)
Objetivos: Este estudo foi desenvolvido para avaliar o diâmetro transverso da alça intestinal exteriorizada como fator preditor de resultado adverso, nas gestações com gastrosquise fetal isolada. Métodos: Estudo retrospectivo envolvendo 94 gestações únicas. Foi realizada a medida do diâmetro transverso da alça intestinal (DTA) herniada, por meio da ultrassonografia antenatal, até 3 semanas antes do parto. Foi considerado resultado perinatal adverso: óbito intra-útero, óbito neonatal e complicações intestinais. Resultados: a última medida ultrassonográfica do DTA foi realizada com 35,6 ± 1,6 semanas e o tempo médio do intervalo entre a última medida e o parto foi de 6,2 ± 5,0 dias. Ocorreram 10 (10,6%) casos de óbitos intraútero e neonatal; foram observadas complicações intestinais em 8 (8,5%) casos. DTA 15, 20, 25 e 30 mm foram identificadas em 87, 46, 13 e 4% das gestações com prognóstico favorável, respectivamente. O DTA 25 mm apresentou valores de sensibilidade de 38%, e, valores preditivo positivo e preditivo negativo de 38% e 87%, na predição de resultados adversos. Para o DTA 30 mm, os valores foram: 19, 50 e 85%. A área sob a curva ROC do valor observado/esperado do DTA para cada idade gestacional foi de 0,67, sendo o melhor ponto-de-corte em 1,39; e, seus valores preditivos foram semelhantes aos do DTA 25 mm. Dilatação intestinal esteve significantemente associada com baixa taxa de fechamento primário da parede abdominal, longo período para iniciar a dieta via oral e internação hospitalar prolongada. Conclusões: Dilatação intestinal demonstrada até 3 semanas antes do parto é preditora de complicações intestinais e está associado a baixa taxa de fechamento primário da parede abdominal, longo período para iniciar a dieta via oral e de internação hospitalar / Objectives: Evaluate bowel diameter as a predictor of adverse outcome in isolated fetal gastroschisis. Methods: Retrospective study involving 94 singleton pregnancies. Ultrasound measurements of herniated bowel transverse diameter (BTD) were performed up to 3 weeks before delivery. Adverse outcome was intrauterine/ neonatal death and/or bowel complications. Results: Last BTD was recorded at 35,6 ± 1,6 weeks and mean interval to delivery was 6,2 ± 5,0 days. Intrauterine/ neonatal death occurred in 10 (10,6%) cases; bowel complications were observed in 8 (8,5%). BTD 15, 20, 25 and 30mm were found in 87, 46, 13 and 4% of pregnancies with a favorable outcome, respectively. BTD 25 mm sensitivity was 38%, positive and negative predictive values, 38% and 87%. For BTD 30 mm, the values were: 19, 50 and 85%. Observed/expected BTD ROC curve showed an area of 0,67, with best cut-off at 1,39; prediction values were similar to those for BTD 25 mm. Bowel dilatation was also significantly associated with lower rate of primary surgical closure, longer period to full oral feeding and prolonged hospital stay. Conclusions: Bowel dilatation demonstrated up to 3 weeks before delivery is a predictor of intestinal complications and is associated with lower rate of primary surgical closure, longer period to achieve full oral feeding and hospital stay
28

Influência do alargamento cervical na determinação do instrumento apical inicial utilizado para instrumentação dos canais radiculares de primeiros molares superiores: análise por microscopia eletrônica de varredura / Influence of cervical preflaring on determination of apical file size using to instrumentation in root of first maxillary molars: SEM analysis

Doglas Cecchin 02 February 2009 (has links)
O objetivo deste estudo foi avaliar ex vivo a influência do alargamento cervical na determinação do instrumento apical inicial (IAI), no comprimento de trabalho (CT), dos canais radiculares de primeiros molares superiores, e determinar a forma do canal a 1 mm do ápice. Cinqüenta dentes foram divididos aleatoriamente em 5 grupos (n=10) de acordo com o preparo dos terços cervical e médio do canal: GI- sem alargamento; GII- brocas Gates- Glidden (#2, #3) (GG); GIII- AET (S1, SC, S2 e S3); GIV- GT Rotary File (20/06, 20/08, 20/10 e 20/10) (GT); GV- LA Axxess (20.06, 35.06) (LA). Os canais foram explorados com lima tipo K inserindo-se passivamente a lima 08 no CT, e limas de diâmetros sucessivamente maiores até obter a sensação de travamento. Foram feitas secções transversais no CT, analisadas em MEV e a área do IAI e a área do canal radicular foram medidas para verificar a porcentagem que o IAI ocupou no interior do canal em cada amostra. A forma do canal radicular foi classificada em circular, oval e achatada. A análise de variância indicou diferença estatisticamente significante entre a área ocupada pelo IAI entre os grupos experimentais (p<0,0001). Os resultados mostraram que, para o canal mésio-vestibular, os valores decrescentes em porcentagem que o IAI ocupou no interior do canal foram: LA Axxess (66,70 ± 7,10) > GT (44,16 ± 9,35) = AET (44,10 ± 8,88) > GG (33,17 ± 6,68) = sem alargamento (23,85 ± 6,86); para o canal disto-vestibular: LA Axxess (75,12 ± 8,56) > GT (58,68 ± 7,70) = AET (54,66 ± 7,12) > GG (39,76 ± 7,52) > sem preparo (26,90 ± 6,10); e para o canal palatino: LA Axxess (66,55 ± 11,40) > AET (51,98 ± 10,67) = GT (49,50 ± 10,05) > GG (35,70 ± 7,62) > sem preparo (21,43 ± 2,79). A forma do canal foi predominantemente achatada para o canal mésio-vestibular, circular para o canal distovestibular e oval para o canal palatino. Pode-se concluir que o preparo dos terços cervical e médio do canal radicular permite melhor determinação do IAI, e que o preparo cervical com brocas LA Axxess apresentou a melhor adaptação do IAI no CT. / The aim of this study was to investigate ex vivo the influence of cervical preflaring on determination the initial apical file (IAI), in the working length (WL), of the root canals of the maxillary first molars and to determine the shape of the canal at 1 mm from the apex. Fifty teeth were randomly divided into 5 groups (n=10) in accordance with the preflaring of the cervical and middle thirds of the canal: GI - without preflaring; GII - Gates-Glidden burs (#2, #3) (GG); GIII - AET (S1, SC, S2 and S3); GIV - GT Rotary File (20/06, 20/08, 20/10 and 20/10) (GT); GV - LA Axxess burs (20.06, 35.06) (LA). The canals were sized with the type K-file, passively inserting the file 08 in the WL and files with successively greater diameters until a binding sensation was felt. Cross sections were made in the WL, analyzed by SEM and the IAI area and the area of the root canal were measured to verify the percentage that the IAI occupied inside the canal in each sample. The shape of the root canal was classified as circular, oval and flattened. The analysis of variance indicated a statistically significant difference between the area occupied by the IAI and the experimental groups (p<0.0001). The results showed that for the mesiobuccal canal, the decreasing values by percentage that the IAI occupied inside the canal were: LA Axxess (66.70 ± 7.10) > GT (44.16 ± 9.35) = AET (44.10 ± 8.88) > GG (33.17 ± 6.68) = without preflaring (23.85 ± 6.86); for the distobuccal canal: LA Axxess (75.12 ± 8.56) > GT (58.68 ± 7.70) = AET (54.66 ± 7.12) > GG (39.76 ± 7.52) > without preflaring (26.90 ± 6.10); and for the palatal canal: LA Axxess (66.55 ± 11.40) > AET (51.98 ± 10.67) = GT (49.50 ± 10.05) > GG (35.70 ± 7.62) > without preflaring (21.43 ± 2.79). The shape of the canal was predominantly flattened for the mesiobuccal canal, circular for the distobuccal canal and oval for the palatal canal. It may be concluded that the preflaring of the cervical and middle thirds of the root canal allows better determination of the IAI and that the cervical preflaring with LA Axxess burs presented better adaptation of the IAI in the WL.
29

Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos / Influence of dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings with electronic apex locators.

Orosco, Fernando Accorsi 19 November 2010 (has links)
Este trabalho teve como objetivo avaliar a influência da espessura de dentina radicular apical, da constrição apical e do diâmetro do forame apical na precisão de leituras realizadas com os localizadores foraminais eletrônicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraídos, com raízes íntegras e ápices completamente formados e portadores de um único canal. Por meio de um paquímetro, as espessuras radiculares dos dentes foram medidas, no sentido mésio-distal a 1,0 e a 4,0mm aquém do forame apical. Após a abertura coronária, uma lima tipo K no 10, munida de limitador de penetração, foi introduzida no canal radicular até que sua extremidade pudesse ser visualizada na altura do forame, com o auxílio de um microscópio óptico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatação do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numérica decrescente, da número 5 até a número1, até 4,0mm aquém do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medição com os localizadores foraminais eletrônicos. Tal modelo era constituído por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orifício lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletrônico e, para a medição, no seu interior, foi colocado alginato e, então, encaixado o componente de menor diâmetro, fazendo com que o ápice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se a seqüência de instrumentação e medida até a lima tipo K no 130; a lima tipo K no 10 foi utilizada em todos os diâmetros. Terminada essa fase, os dentes tiveram os canais sobreinstrumentados, isto é, a ponta da lima ultrapassou o forame apical em 1,0mm, a partir da lima tipo K no 25 e seguindo até a lima tipo K no 130; novas medidas foram obtidas com cada lima que sobreinstrumentou o forame e a lima no 10 foi utilizada em todos os diâmetros. Em todos os casos o canal radicular estava preenchido com hipoclorito de sódio a 1%. Para a análise estatística foram empregados os testes de Análise de Variância a dois critérios e de Tukey. Os resultados indicaram que as variáveis capazes de influenciar a recisão das leituras com os localizadores foraminais eletrônicos foram a eliminação da constrição apical com o consequente aumento do diâmetro do forame apical, ao contrário da espessura da parede dentinária do canal radicular, que não interferiu significativamente na precisão das leituras. / This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm beyond the apical foramen, beginning with 25 K file up to 130 K file; new measurements were obtained with each file overinstrumenting the apical foramen, and the 10 K file was used in all diameters. In all cases, the root canal was irrigated with 1% sodium hypochlorite. Statistical analysis was performed by two-way analysis of variance and the Tukey test. The results indicated that the variables that may influence the accuracy of readings with the electronic apex locators were the elimination of apical constriction with consequent increase in the diameter of the apical foramen, different from the thickness of the root canal dentinal wall, which did not significantly influence the accuracy of readings.
30

Propagação por estaquia de Ochroma pyramidale (Cav. ex Lam.) Urban. (Pau de balsa) / Propagation by cutting of Ochroma pyramidale (Cav. exLam.) Urban. (Balsa wood)

Modenezi, Raul Marcílio 28 January 2019 (has links)
O pau de balsa é uma espécie arbórea que apresenta importância econômica principalmente pelos diversos usos da madeira, e ecológica por sua participação na sucessão florestal. Até o presente momento o principal meio de multiplicação desta espécie tem sido por sementes. A obtenção de mudas clonais é a principal dificuldade para o cultivo em larga escala dessa espécie. Portanto, o uso da técnica de propagação vegetativa para a silvicultura clonal, como por exemplo, o processo de estaquia, torna-se uma ferramenta útil para superar as possíveis dificuldades que as mudas produzidas a partir de sementes trazem para a silvicultura. Este trabalho teve como objetivo avaliar o efeito do diâmetro da estaca, o tratamento com promotor de enraizamento (AIB), diferentes tipos de substrato e o uso da câmara úmida, avaliando-se o enraizamento, a formação de calos e sobrevivência de estacas de Ochroma pyramidale. Para tanto, quatro experimentos foram instalados, o primeiro foi realizado para avaliar a interação entre o diâmetro das estacas a serem divididas entre o fino, médio e espesso, relacionado ao uso de AIB nas concentrações de 0 e 5.000 mg.L-1. No segundo experimento avaliou-se a interação entre a aplicação de AIB nas concentrações de 0, 1000, 2000 e 4000 mg.L-1 e a região de origem das estacas no ramo, em basal, mediana e apical. No terceiro experimento foram avaliados os tipos de substrato (Areia, Carolina II, Fibra de coco e Vermiculita) em interação com as estacas das duas diferentes origens do ramo (mediana e apical). Por fim, no quarto experimento avaliou-se o uso de ambiente protegido por câmara úmida e a aplicação de diferentes concentrações de AIB (0, 2000, 4000 e 6000 mg.L-1). Concluiu-se que a sobrevivência das estacas é maior entre estacas de diâmetros médio e espesso (1 a 2 cm de diâmetro) e entre estacas provenientes da parte basal do ramo. Quanto ao uso de AIB, os maiores índices de sobrevivência são apresentados quando se aplica 1000 mg.L-1 de AIB, e também sem o uso de ambiente protegido por câmara úmida. A formação de calos é maior entre as estacas de diâmetros médio e espesso (1 a 2 cm de diâmetro) e entre as estacas da parte basal do ramo. Em relação à formação de calos e utilização de AIB, as maiores taxas ocorreram na ausência, 1000 e 4000 mg.L-1 de AIB. O enraizamento das estacas O. pyramidale ocorreu quando 6000 mg.L-1 de AIB foi aplicado. / The balsa wood is a tree species that has economic importance mainly by the many uses of wood, and ecological for its participation in the forest succession. Until the present time, the main way of multiplication of this species have been by seeds. Obtaining clone stakes is the main difficulty for large-scale cultivation of this species. Therefore, the use of the vegetative propagation technique for the clonal silviculture, as for example by cuttings process, becomes useful tools for overcome the possible difficulties that seedlings produced from seeds bring to forestry. This work aimed to evaluate the effect of the diameter of the cutting, the treatment with rooting promoter (IBA), different types of substrate and the use of the chamber moist, by evaluating the rooting, the callus formation and the survival of cuttings of O. pyramidale. For this purpose, four experiments were set up, the first one was carried out to evaluate the interaction between the diameter of the cuttings to be divided between thin, medium and thick, related to the use of AIB in the concentrations of 0 and 5,000 mg.L-1. In the second experiment was evaluated the interaction between the application of IBA at the concentrations of 0, 1000, 2000 and 4000 mg.L-1 and the source region of the cuttings in the branch, in basal, median and apical. In the third experiment was evaluated the types of substrate (Sand, Carolina II, Fiber of coconut, and Vermiculite) in interaction with cutting of the two different origins of the branch (median and apical). Finally, in the fourth experiment we evaluated the use of protected environment by the chamber moist and the application of different IBA concentrations (0, 2000, 4000 and 6000 mg.L-1). It was concluded that the survival of the cutting is higher among the cutting of diameters of medium and thick (1 to 2 cm in diameter) and between the cutting originating from the basal branch. As to the use of IBA, the highest rates of survival are shown when applied to 1000 mg.L-1 of IBA, and without the use of environment-protected chamber moist. The callus formation is greater between medium and thick diameters cuttings (1 to 2 cm in diameter) and between cuttings from the branch basal part. Regarding to callus formation and IBA utilization, the highest rates occurred in the absence, 1000 and 4000 mg.L-1 of IBA. The O. pyramidale cuttings rooting occurred when 6000 mg.L-1 of IBA was applied.

Page generated in 0.0555 seconds