• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 400
  • 400
  • 400
  • 200
  • 179
  • 91
  • 63
  • 61
  • 59
  • 54
  • 54
  • 49
  • 46
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Valor da ecocardiografia tridimensional em tempo real em portadores de cardiomiopatia hipertrófica. Comparação com a ecocardiografia bidimensional e a ressonância magnética cardiovascular / Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with twodimensional echocardiography and magnetic resonance imaging

Bicudo, Leticia Santos 30 November 2007 (has links)
INTRODUÇÃO: A ecocardiografia tridimensional em tempo real (E3DTR) vem provando sua acurácia para quantificar os volumes do ventrículo esquerdo (VE), fração de ejeção (FEVE) e massa em pacientes com cardiomiopatia. Na cardiomiopatia hipertrófica (CMH), onde a morfologia ventricular pode estar muito alterada, a análise das estruturas cardíacas é fundamental para indicação da terapêutica ideal. A ressonância magnética cardiovascular (RMC) é um método superior na análise segmentar do VE em comparação a ecocardiografia bidimensional (E2D), mas com alta complexidade e existente em poucos centros diagnósticos, com contraindicações e limitações para a sua realização. MÉTODOS: Estudo transversal, comparativo, duplo cego, em 20 portadores de CMH, com E2D, E3DTR e RMC realizados com intervalo máximo de 06 meses e armazenados em formato digital. A espessura das paredes, volumes, função sistólica e massa ventricular esquerda foram analisados pelos métodos ecocardiográficos e pela RMC, assim como o movimento anterior sistólico da valva mitral, o índice geométrico do VE e o índice sistólico de dissincronia do VE. ANÁLISE ESTATÍSTICA: Análise estatística pelo coeficiente de concordância de Lin, correlação linear de Pearson e modelo de Bland-Altman. RESULTADOS: Foi obtida exeqüibilidade elevada acima de 94%, dependente do parâmetro avaliado. Concordância satisfatória e forte correlação linear evidenciada para a análise segmentar (Rc>0.84 e r>0.85; p<0.0001) observada para os métodos ecocardiográficos comparados à RMC, com concordância excelente entre os métodos ecocardiográficos (Rc=0,92 e r=0,92, p<0,0001). Concordância satisfatória e forte correlação linear para a fração de ejeção do VE (Rc=0.83 e r=0.93; p<0.0001) pela E3DTR comparada à RMC. Concordância excelente e forte correlação linear para o VDFVE e VSFVE pela E3DTR comparada à RMC e pela E2D comparada à E3DTR (Rc>0.90 and r>0.95; p<0.0001), assim como para a massa do VE, para os métodos E3DTR e RMC (Rc=0.96 e r=0.97; p<0.0001). Evidenciada maior exeqüibilidade da análise do MAS pela E3DTR. O índice geométrico do VE foi >0,15mmxm²xml-1 para todos os métodos. Observada correlação negativa entre o índice de dissincronia do VE e o percentual de fibrose miocárdica, sem significância estatística. CONCLUSÕES: A E3DTR é precisa e superior à E2D na avaliação da distribuição da hipertrofia miocárdica, quantificação dos volumes, função e massa ventricular esquerda em pacientes com CMH quando comparada à RMC, e parece ser superior na análise do MAS, pela melhor visão espacial da valva mitral.Todas as medidas do índice geométrico do ventrículo esquerdo estavam acima de 0,15mmxm²xml-1, compatível com CMH. Não foi identificada correlação entre o índice sistólico de dissincronia ventricular esquerda e a fibrose miocárdica. / INTRODUCTION: Real-time three-dimensional echocardiography (RT3D) has been demonstrated an accurate technique for the quantification of left ventricular (LV) volumes, ejection fraction (LVEF), and mass. In patients with hypertrophic cardiomyopathy (HCM), in which alterations of ventricular morphology are common, cardiac structural analysis is of utmost importance for guiding adequate therapy. Although magnetic resonance imaging (MRI) seems to have better definition for segmental analysis than two-dimensional echocardiography, (2D-E), it is considered a complex test with low availability and some limitations for use. METHODS: Comparative and double-blinded study in 20 patients with HCM. All patients underwent 2DE, RT3D and MRI within maximal interval of 6 months. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, systolic function, LV mass, systolic anterior motion of mitral valve, LV geometric index and LV dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. RESULTS: Feasibility for measurements by MRI and echocardiography was 94%. There was good agreement and linear correlation between segmental analysis by echocardiography and MRI (Rc>0.84 and r>0.85; p<0.0001) and excellent correlation between 2DE and RT3DE (Rc=0.92 and r=0.92; p<0.0001). We also observed good agreement and linear correlation between RT3DE and MRI for ejection fraction (Rc=0.83 and r=0.93; p<0.0001) and excellent agreement and linear correlation between RT3DE and MRI for LV end diastolic volume and LV end systolic volume determinations (Rc>0.90 and r>0.95; p<0.0001) and mass (Rc=0.96 and r=0.97; p<0.0001). The feasibility for systolic anterior motion of mitral valve was higher by RT3DE (91%) than 2DE (64%). LV geometric index was >0.15 mmxm²xml-1 for all techniques. There was no correlation between LV dyssynchrony index and the percentage of myocardial fibrosis. CONCLUSIONS: RT3D is an accurate technique with superior performance than 2DE for the evaluation of myocardial hypertrophy localization, LV volume and functional determination as well as for LV mass assessment in patients with HCM in comparison with MRI. In addition, it seems to be superior for the analysis of systolic anterior motion due to its better spatial view of mitral valve. All measurements of LV geometric index were above the value of 0.15 mmxm²xml-1, and such findings are compatible with HCM. No correlation between LV dyssynchrony index by RT3D and the percentage of myocardial fibrosis determined by MRI was identified.
282

Determinação do tamanho e extensão do infarto agudo do miocárdio pela ecocardiografia com perfusão em tempo real em seres humanos: comparação com a ressonância magnética / Determination of size and extent of acute myocardial infarction by real time myocardial contrast echocardiography in humans: a comparison with magnetic resonance imaging

Trindade, Maria Luciana Zacarias Hannouche da 08 July 2005 (has links)
O objetivo da reperfusão mecânica ou medicamentosa em pacientes com infarto agudo do miocárdio (IAM) é a restauração do fluxo sangüíneo na artéria relacionada ao infarto, a fim de limitar a necrose miocelular e preservar a função contrátil, que são os maiores preditores de sobrevida após o IAM. Entretanto, seu sucesso é indicado pela reperfusão nos capilares miocárdicos e não pela recanalização da artéria relacionada ao infarto. A ecocardiografia com perfusão miocárdica em tempo real pode ser usada para avaliar a perfusão nos capilares miocárdicos e estimar o tamanho do infarto em vários estudos experimentais. O objetivo deste estudo foi determinar a área do miocárdio infartado e sua extensão transmural pela ecocardiografia com perfusão miocárdica em tempo real, em pacientes hospitalizados nos primeiros dias após primo infarto agudo do miocárdio, tendo como padrão de referência a ressonância magnética de perfusão. Prospectivamente, foram estudados 20 pacientes (12 homens), com idade média de 64,2 ± 13,3, dentro de 12 horas de reperfusão mecânica ou medicamentosa. Os exames de ecocardiografia e ressonância magnética foram realizados do segundo ao quinto dia de infarto. O contraste \"PESDA (perfluorocarbon-exposed sonicated dextrose albumin)\" foi administrado em veia periférica, na dose de 0,1ml/Kg, em infusão contínua. A análise ecocardiográfica foi feita por uma análise qualitativa (visual) denominada escala de cinza e por uma análise quantitativa, chamada imagem paramétrica. A área de infarto média foi de 3,03 ± 2,77 cm2 para a escala de cinza (r=0,97), de 3,36 ± 2,82 cm2 para a imagem paramétrica (r= 0,99) e de 3,42 ± 2,80 cm2 para a ressonância magnética. O porcentual médio da área de infarto pela ecocardiografia em escala de cinza foi de 15,22% ± 14,84% (r= 0,97), pela imagem paramétrica foi de 16,46% ± 14,41% (r= 0,99) e pela ressonância magnética foi de 16,76% ± 14,48%. A extensão transmural do infarto em cada segmento infartado pela escala de cinza,apresentou uma correlação menor (r=0,77) em relação à imagem paramétrica (r=0,93). Em conclusão, este estudo mostrou uma excelente correlação entre ecocardiografia com perfusão miocárdica em tempo real (sobretudo pela imagem paramétrica) e ressonância magnética nas medidas da área de infarto e seu porcentual, assim como na determinação de sua extensão transmural em pacientes internados por infarto agudo do miocárdio / The aim of mechanical or pharmacological reperfusion in patients with AMI is to restore blood flow through the infarct related artery in order to limit myocellular necrosis and ultimately preserve myocardial contractile function, which is still the most powerful predictor of survival after acute myocardial infarction. The success of reperfusion, however, is indicated by perfusion of myocardial capillaries rather than simply patency of the infarct related artery. Myocardial contrast echocardiography (MCE) can be used to assess myocardial capillary perfusion and ultimately the infarct size in animals. The aim of this study was to determine by MCE the transmural extent and infarct size using magnetic resonance imaging (MRI) as a gold standard. We prospectively studied 20 patients (12 men; mean age 64.2 ± 13.3) admitted for a first acute myocardial infarction, within 12 hours after mechanical or pharmacological reperfusion. The MCE and MRI were performed between the 3rd and 5th day of acute myocardial infarction (AMI). A suspension of 0.1 ml/kg of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) ultrasound contrast agent was administered as a continuous infusion. The interpretation of perfusion images by MCE was assessed by qualitative analysis (visual- VIS) and a quantitative one called parametric image (PI). The average infarct area showed by VIS was 3.03 ± 2.77 cm 2, by PI was 3.36 ± 2.82 cm 2 and by MRI was 3.42± 2.80cm 2. The average percentage of infarct area by VIS was 15.22% ± 14.84%, by PI was 16.46% ± 14.41% and by MRI was 16.76% ± 14.48%. The transmural extent was calculated in each infarcted segment by VIS, with a worse correlation (r=0,77) than PI (r=0,93). In conclusion, this study showed that MCE, in special PI, correlates well with MRI in detecting infarct size, percentage of infarct size and transmural extent in patients with acute myocardial infarction
283

Análise de medidas lineares da mandíbula em modelos tridimensionais reformatados a partir da tomografia computadorizada de feixe cônico / Mandibular linear measurements on 3D CBCT models

Poleti, Marcelo Lupion 10 December 2012 (has links)
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula em modelos tridimensionais gerados a partir da tomografia computadorizada de feixe cônico (TCFC) em dois programas (Dolphin®. Material e Métodos: Dez mandíbulas com marcadores de sílica foram submetidas à TCFC seguindo o protocolo de voxel 0,3 mm do aparelho i-CAT Classic®. Vinte medidas lineares foram realizadas duas vezes, de maneira aleatória, nos modelos tridimensionais nos programas Dolphin®, nos filtros Translúcido e Sólido-1, e InVesalius®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas por um segundo examinador. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse, teste de Bland-Altman e erro absoluto e percentual foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Alta precisão foi encontrada no programa Dolphin®, filtro Translúcido e Sólido-1 e InVesalius®, com diferença máxima entre as mensurações de 0,27; 0,26 e 0,17 mm, respectivamente. Com relação à acurácia, 10 variáveis no filtro Translúcido; oito no filtro Sólido-1 e 13 no programa inVesalius® foram diferentes estatisticamente em relação as medidas físicas. Porém, 95%, 100% e 90% das medidas apresentaram valores abaixo do valor considerado clinicamente relevante (1 mm) nos filtros Translúcido e Sólido-1 e no programa InVesalius®, respectivamente. Conclusão: Os modelos tridimensionais com marcadores hiperdensos, gerados pelos programas Dolphin®, filtro Translúcido e Sólido-1, e InVesalius® podem ser utilizados com precisão e acurácia para a obtenção de medidas lineares. / Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different software (Dolphin® and InVesalius®). Methods: Ten dry human mandibles were scanned at voxel size of 0.3 mm (i-CAT Classic®). Twenty measurements were made twice, randomized, on 3D model generated by the software Dolphin (filter Translucent and Solid-1) and InVesalius. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) BlandAltman, absolute and percentage mean error were used for evaluating accuracy and reliability (p<0.05). Results: Excellent reliability values were found for linear measurements from CBCT volume rendering images in all methods (Dolphin Translucent, Solid-1 and InVesalius), with the mean measurement of 0.27; 0.26 and 0.17 mm, respectively. Ten measurement errors for Dolphin Translucent, eight for Solid-1 and 13 for InVesalius were statistically significant different from physical measurements; however, 95%, 100% and 90% of the measurements were, respectively, below the value clinically relevant (1 mm). Conclusion: Linear measurements on 3D model generated by the software Dolphin (Translucent and Solid-1) and InVesalius are reliable and accurate and can be used for linear measurements.
284

Estudo comparativo da espessura do músculo masseter em seres humanos através de exames de tomografia computadorizada e ultrassonografia / Comparative study of the thickness of the masseter muscle in human beings with exams of computerized tomography scan and ultrasonography

Pastore, Gabriel Pires 01 February 2005 (has links)
A articulação tempo-mandibular vem sendo cada vez mais motivo de interesse e pesquisa por parte dos cirurgiões-dentistas, a gama de exames que favorecem o diagnostico dessas patologias é vasta, porém alguns exames são inacessíveis ao paciente ou de difícil interpretação pelo profissional. Neste estudo realizamos o estudo comparativo do músculo masseter em 14 voluntários que foram submetidos a exames de tomografia computadorizada e ultra-sonografia, para mensuração do diâmetro transverso do citado músculo em diferentes posições. Os resultados indicam diferença estatisticamente significante quando comparadas às diferenças da espessura do masseter pelos métodos citados. A realização do exame de ultra-sonografia deve ser realizado de forma criteriosa, seus valores apresentam-se específicos e quando comparados aos valores obtidos na tomografia computadorizada podem traduzir dados importantes para o diagnóstico. A ultra-sonografia como método de diagnóstico para a ATM acrescenta dados que facilitam o diagnóstico precoce lesões que acometem a musculatura mastigatória, além de ser um exame de baixo custo, alta especificidade, não invasivo e realizado em tempo real / The temporo mandibular joint it is being more and more reason interest for researches on the part of the dentistry, the range of exams that favor it I diagnose of those pathologies it is vast, however some exams are inaccessible to the patient or of difficult interpretation for the professional. In this study we accomplished the comparative study of the masseter muscle in 14 volunteers that they were submitted to exams of computerized tomography scan and ultrasonography, for measured of the cross section of the mentioned muscle in different positions. The results indicate difference significant when compared to the differences of the thickness of the masseter by the mentioned methods. The accomplishment of the ultrasonography exam should be accomplished in a discerning way, your values come specific and when compared to the values obtained in the computerized tomography scan they can translate important data for the diagnosis. The ultrasonography as diagnosis method for temporo mandibular joint increases data that facilitate the diagnosis precocious lesions that attack the Thickness musculature, besides being a low cost exam, high specifity, non invasive and accomplished in real time
285

Inovação em serviços médicos de diagnóstico por imagem no Brasil: um estudo de caso de parceria fornecedor - cliente final

Barberio, Paulo de Tarso 19 March 2014 (has links)
Made available in DSpace on 2016-04-25T16:44:38Z (GMT). No. of bitstreams: 1 Paulo de Tarso Barberio.pdf: 1628573 bytes, checksum: 1e556fde0f4352a86f3ad203fbbbef6b (MD5) Previous issue date: 2014-03-19 / In the search for competitive advantage, companies in the service sector begin to look with greater attention to the need for innovation as vital to the survival or even to differentiate within the current business landscape. The ability or competence to innovate has become an essential ingredient of the current dynamics of the business segment. Innovation in services is a real phenomenon and is integrated into the services used in everyday people from using mobile internet to the hiring of distance learning. It is no different in medical diagnostic imaging services in Brazil, where companies seek to improve the perception of customers regarding services through new and innovative processes. In this context, the aim of the study was to investigate ways and alternatives for small and medium companies in the medical services diagnostic imaging industry create value from the perpective of customers, providing unique solutions and innovative services. The literature review included the historical evolution of diagnostic medicine, as well as the development of the medical equipment market. Regarding innovation, the study reviewed general aspects of the subject, and then the phenomenon of innovation in services, in particular, the main modes of innovation proposed by Gallouj and Weinstein (1997). The literature considered allows a better view of the possibilities of implementing innovative processes within organizations, as well as widen the debate about what can be considered innovation in services. Thus, the case study, in that it analyzes the entire process of implementing new services, it seems feasible as research into alternative implementation and understanding of the main obstacles commonly found for making changes in organizational culture / Na busca por vantagem competitiva, as empresas do segmento de serviços começam a olhar com maior atenção para a necessidade da inovação como elemento vital para a sobrevivência ou mesmo para se diferenciar dentro do atual panorama empresarial. A habilidade ou competência para inovar tornou-se um ingrediente fundamental da dinâmica atual dos negócios no segmento. A inovação em serviços é um fenômeno real e está integrada nos serviços utilizados no dia a dia das pessoas, desde a utilização de internet móvel até a contratação de ensino a distância. Não é diferente no segmento de serviços médicos de diagnóstico por imagem no Brasil, onde as empresas buscam melhoria na percepção dos clientes em relação aos serviços prestados através de novos e inovadores processos. Nesse contexto, o objetivo do estudo foi investigar alternativas para pequenas e médias empresas do setor de serviços médicos de diagnóstico por imagem criarem valor a partir da perpectiva dos clientes, oferecendo soluções diferenciadas e serviços inovadores. A revisão da literatura contemplou a evolução histórica da medicina diagnóstica, assim como o desenvolvimento do mercado de equipamentos médicos no país. No tocante a Inovação, o estudo revisou aspectos gerais sobre o tema e, posteriormente o fenômeno da inovação em serviços, em especial, os principais modos de inovação propostos por Gallouj e Weinstein (1997). A literatura considerada permite uma melhor visão das possibilidades de implementação de processos inovadores dentro das organizações, bem como amplia o debate sobre o que pode ser considerado inovação em serviços. Dessa forma, o estudo de caso, na medida em que analisa todo processo de implementação de novos serviços, se mostrou viável quanto a investigação de alternativas de implementação e no entendimento dos principais obstáculos comumente encontrados para realização de mudanças na cultura organizacional
286

Shear wave elastography with two-dimensional ultrasound transducer. / Elastografia por onda de cisalhamento com transdutor de ultrassom bidimensional.

Santos, Djalma Simões dos 30 July 2018 (has links)
Chronic liver diseases are the eighth leading cause of death in Brazil and a major public health problem in the world. Liver biopsy is the best available reference standard for evaluating and classifying stages of liver diseases, but it presents limitations and complications that are common in invasive methods. In recent years, elasticity imaging methods have been the focus of intense research activity with the ability to measure mechanical properties of soft tissues in a non-invasive way. Shear wave elastography is one of the most promising methods because it enables to quantitatively assess tissue elasticity. However, the current depth range of shear wave elastography impedes its application in obese patients, which have a great risk of developing liver disease. The aim of this study is to investigate the use of shear wave elastography in deeper tissues using a two-dimensional ultrasound transducer array. An efficient transducer array arrangement was simulated, fabricated and characterized. The results show that the proposed transducer configuration presents enhanced transmitting capabilities for generating tissue displacement in deeper tissues. In addition, numerical simulations were performed in order to track the tissue deformation and reconstruct its elastic properties. / Doenças crônicas do fígado são a oitava causa de morte no Brasil e um dos principais problemas de saúde pública do mundo. A biópsia do fígado é o melhor padrão de referência disponível para avaliação e classificação dos estágios das doenças hepáticas, mas apresenta limitações e complicações que são comuns nos métodos invasivos. Nos últimos anos, métodos de imagem por elasticidade têm sido o foco de intensa atividade de pesquisa, pois têm a capacidade de medir propriedades mecânicas dos tecidos moles de maneira não invasiva. A elastografia por ondas de cisalhamento é um dos métodos mais promissores, pois permite avaliar quantitativamente a elasticidade do tecido. No entanto, a atual faixa de profundidade da elastografia por ondas de cisalhamento impede sua aplicação em pacientes obesos, que apresentam grande risco de desenvolver doença hepática. O objetivo deste estudo é investigar o uso da elastografia por onda de cisalhamento em tecidos mais profundos usando um transdutor de ultrassom bidimensional. Uma configuração eficiente de transdutores matriciais foi simulada, fabricada e caracterizada. Os resultados mostram que o transdutor proposto possui capacidade de transmissão melhorada para gerar deslocamento em tecidos profundos. Além disso, simulações numéricas foram realizadas para monitorar a deformação do tecido e reconstruir suas propriedades elásticas.
287

Estudo venográfico dos dígitos de bovinos jovens antes e após aplicação intrarruminal de oligofrutose / Venographic study of foot of young bovine before and after intrarruminal oligofructose application

Freitas, Sabrina Lucas Ribeiro de 11 September 2015 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-01-05T14:15:02Z No. of bitstreams: 2 Dissertação - Sabrina Lucas Ribeiro de Freitas - 2015.pdf: 1727922 bytes, checksum: 3502487e7bd9da8dda2d7674ddde726a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-06T09:24:49Z (GMT) No. of bitstreams: 2 Dissertação - Sabrina Lucas Ribeiro de Freitas - 2015.pdf: 1727922 bytes, checksum: 3502487e7bd9da8dda2d7674ddde726a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-06T09:24:49Z (GMT). No. of bitstreams: 2 Dissertação - Sabrina Lucas Ribeiro de Freitas - 2015.pdf: 1727922 bytes, checksum: 3502487e7bd9da8dda2d7674ddde726a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-09-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The real etiopathogeny of many digital diseases of cattle is still reason to many questions. It can´t be ignored that compromising perfusion and draining of digital vasculature have close relation with some disorders of the digit in this specie. Therefore, a solid knowledge on digital vasculature of the bovine can lead to better understanding of diseases like laminitis. This study intended to decribed venographic findings of the digits of young crossbred (Bos indicus X Bos taurus) cattle, before and after intrarruminal administration of oligofructose as na alternative to the study of laminitis etiopathogenesis a help the study of vascular anatomy of the digits. In the study was used seven crossbred (Bos indicus X Bos taurus) steers, non castrated, aging 12,6±0,9 months and weigthing 156±37,8 kg. Animals were sorted in two groups (GI and GII) receiving 13 and 17 g/kg respectively of intrarruminal oligofructose. Venography were done in the digit of cattle in five different moments, 15 days before (M0), 36 hours (M1), seven (M2), 15 (M3) and 30 (M4) days after intrarruminal administration of high fermentative carboidrate. Venography examination intended to evaluate topographic anatomy and possible vascular changes in the distal pelvic limb of the animals. Description of topographic anatomy was done based on radiographs obtained in all moments and to vascular changes in the distal limb was evaluated diferences among moments, having M0 as control. In the evaluation of vascular changes, main veins and regions like coronary corium were evaluated. Three veins were chosen to measurement of its diameter and data was analysed using ANOVA and T test at 5% significance level. Main veins and regions of coronary region, in diferente moments, were evaluated descriptively. Were identified changes in vascularization at diferente moments, like vasodilation 36 hours after oligofructose administration and vasoconstriction in the other moments, in the main veins and regions of coronary corium and bulbs. Animals from GII, changes were more accentuated. There was statistical difference for common digital dorsal III vein beteween M1 and M4 in each group, with dilation in M1 and constriction in M4. For the palmar branch to the digital cushion of medial digit the existing difference was between the groups in M4, with the constriction of the vein more accentuated in GII. It was concluded that venogtraphic exam of digits in pelvic limbs of young crossbred (Bos indicus X Bos taurus) cattle, examining before and after intrarruminal administration of oligofructose permited description of local vascular anatomy and identified changes compatible with laminits in this specie. / A etiopatogenia de várias doenças podais dos bovinos ainda é motivo de especulação. Mas não se pode ignorar que o comprometimento da irrigação e da drenagem sanguínea dos dígitos tem uma relação estreita com diversas alterações que acometem os dígitos dessa espécie animal. Portanto, o conhecimento sólido da vascularização da extremidade distal dos membros locomotores de bovinos pode nortear o entendimento de enfermidades como a laminite. Esse estudo objetivou descrever achados venográficos dos dígitos dos pés de bovinos jovens, mestiços (Bos indicus X Bos taurus), antes e após aplicação intrarruminal de oligofrutose como alternativas ao estudo da etiopatogenia da laminite e auxiliar no estudo da anatomia vascular dos dígitos. No estudo foram empregados, sete animais mestiços (Bos indicus X Bos taurus), inteiros, com 12,6±0,9 meses de idade e peso de 156±37,8 kg. Distribuiu-se por sorteio os animais em dois grupos (GI e GII) que receberam 13 e 17 g/kg de oligofrutose via intrarruminal, respectivamente. Realizou-se venografia dos dígitos dos bovinos, em cinco momentos distintos, sendo 15 dias antes (M0), 36 horas (M1), sete (M2), quinze (M3) e trinta (M4) dias após aplicação intrarruminal do carboidrato de alta fermentação. A venografia teve a finalidade de avaliar a anatomia topográfica e possíveis alterações vasculares da extremidade distal dos membros pélvicos destes animais. A descrição da anatomia topográfica foi realizada com base nas radiografias obtidas em todos os momentos. Para as alterações vasculares da extremidade distal avaliou-se as diferenças entre os momentos, tendo o M0 como controle. Nesta avaliação veias principais e regiões como a rede do cório coronário foram avaliadas. Escolheu-se três veias para proceder a mensuração dos seus diâmetros e analisá-los utilizando-se a Análise de Variância (ANOVA) e o Teste t, com nível de significância de 5%. As veias principais e da região do cório coronário, nos diferentes momentos, foram avaliados de forma descritiva. Identificaram-se alterações na vascularização nos diferentes momentos, como vasodilatação com 36 horas após aplicação de oligofrutose e vasoconstrição nos demais momentos, nas veias principais e das regiões do cório coronário e rede bulbar. Nos animais do GII as alterações foram mais acentuadas. Houve diferença estatística para a veia digital dorsal comum III entre M1 e M4 dentro de cada grupo, sendo que em M1 estava dilatada e M4 constrita. Para o ramo plantar para o coxim digital do dígito medial a diferença existente foi entre os grupos no momento M4, sendo a constrição desta veia mais acentuada no GII. Concluiu-se que o exame venográfico dos dígitos dos membros pélvicos de bovinos jovens, mestiços (Bos indicus X Bos taurus), realizado antes e após aplicação intrarruminal de oligofrutose possibilitou a descrição da anatomia vascular local e identificou alterações compatíveis com a laminite nessa espécie animal.
288

Ultrassonografia abdominal de tamanduás-bandeira (Myrmecophaga tridactyla) machos e fêmeas / Abdominal ultrassonography of giant anteater (Myrmecophaga tridactyla) males and females

Albuquerque, Luíza Lucena de 26 June 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-07-27T15:32:25Z No. of bitstreams: 2 Dissertação - Luíza Lucena de Albuquerque - 2017.pdf: 5105413 bytes, checksum: 31eb52779b210ea8fba7b2359d7ad846 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-07-27T15:35:39Z (GMT) No. of bitstreams: 2 Dissertação - Luíza Lucena de Albuquerque - 2017.pdf: 5105413 bytes, checksum: 31eb52779b210ea8fba7b2359d7ad846 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-07-27T15:35:39Z (GMT). No. of bitstreams: 2 Dissertação - Luíza Lucena de Albuquerque - 2017.pdf: 5105413 bytes, checksum: 31eb52779b210ea8fba7b2359d7ad846 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-06-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The giant anteater (Myrmecophaga tridactyla) is a wild mammal of the superorder of Xenarthras, native to Central and South America, which is currently classified as vulnerable in the list of endangered species. A fact that can have as causes, from the territorial advance of the agricultural activities to the constructions of roads and fires. Scientific research is of great importance for the conservation of species included in this list and there is a dearth of data about the anteater. Among these information to be collected, there is little information about ultrasound examination in this species. The absence of a reference standard for performing and evaluating ultrasonographic examination for specific species may limit the application of this test and disrupt the establishment of an accurate diagnosis. For these reasons, the aim of this study was to establish a reference standard for the ultrasonographic evaluation of the abdomen of male and female giant anteaters. For this, 10 adult animals, five females and five males, clinically healthy, were used from the Fundação Jardim Zoológico de Brasília. The animals were anesthetized using the Foundation's own protocol, the animals were placed in dorsal decubitus position, and then a wide tricotomy of the abdomen was performed to allow abdominal scanning. The visible structures were established in the abdominal ultrasound examination of the anteaters, have also been established: topographic position, anatomical relationships, ecotexture and echogenicity of: urinary vesicle, uterus, testes, kidneys, spleen, liver, stomach and intestines. It has also been described the presence of alterations in some animals, such as: an animal with intrauterine fluid; an animal with hepatomegaly; an animal with splenomegaly; and thre animals with abdominal fluid. It has been verified that the abdominal ultrasound examination of anteater can be performed according to what is already recommended for dogs and cats and its evaluation and interpretation can be compared with the examinations of domestic mammals as well as descriptions already documented in other species of mammals Wild. / O tamanduá-bandeira (Myrmecophaga tridactyla) é uma mamífero silvestre, da superordem Xenarthras, nativo das Américas Central e do Sul e que está, atualmente, classificado como vulnerável na lista de espécies ameaçadas de extinção, fato que pode ter como causas, desde o avanço territorial das atividades agropecuárias às construções de estradas e queimadas Pesquisas científicas são de suma importância para a conservação de espécies inclusas nessa lista e existe uma escassez de dados acerca dos tamanduás-bandeira. Dentre essas informações a serem coletadas, existem poucas informações acerca do exame ultrassonográfico nesta espécie. A ausência de um padrão de referência para a realização e avaliação do exame ultrassonográfico para espécies específicas pode limitar a aplicação deste exame e impedir o estabelecimento de um diagnóstico preciso. Por estes motivos, objetivou-se nesse estudo estabelecer um padrão de referência para a avaliação ultrassonográfica do abdômen de tamanduás-bandeira machos e fêmeas. Para isso, foram utilizados 10 animais adultos, cinco fêmeas e cinco machos, clinicamente saudáveis, provenientes da Fundação Jardim Zoológico de Brasília. Os animais foram anestesiados utilizando protocolo da própria Fundação, os animais foram posicionados em decúbito dorsal e, em seguida, foi realizada a tricotomia ampla do abdômen para possibilitar a varredura abdominal. Foram estabelecidas as estruturas visíveis no exame ultrassonográfico abdominal dos tamanduás, bem como descritas: posição topográfica, relações anatômicas, ecotextura e ecogenicidade de vesícula urinária, útero, testículos, rins, baço, fígado, estômago e alças intestinais. Também foi descrita a presença de alterações em alguns animais, como: líquido intra-uterino; hepatomegalia; esplenomegalia; líquido-livre abdominal. Verificou-se que o exame ultrassonográfico abdominal de tamanduás-bandeira pode ser realizado segundo o que já é preconizado para cães e gatos e sua avaliação e interpretação podem ser comparadas tanto com os exames de mamíferos domésticos quanto com descrições já documentadas em outras espécies de mamíferos silvestres.
289

Referências cefalométricas tridimensionais da simetria dentoesquelética / Three-dimensional cephalometric reference of dentoskeletal symmetry

Porto, Olavo Cesar Lyra 01 November 2012 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2014-10-14T12:59:09Z No. of bitstreams: 2 Dissertacao - Olavo Cesar Lyra Porto - Ciencias da Saude.pdf: 4368065 bytes, checksum: a20fe24dfaac1aa5700048dbfddaf49d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-17T21:35:10Z (GMT) No. of bitstreams: 2 Dissertacao - Olavo Cesar Lyra Porto - Ciencias da Saude.pdf: 4368065 bytes, checksum: a20fe24dfaac1aa5700048dbfddaf49d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-17T21:35:10Z (GMT). No. of bitstreams: 2 Dissertacao - Olavo Cesar Lyra Porto - Ciencias da Saude.pdf: 4368065 bytes, checksum: a20fe24dfaac1aa5700048dbfddaf49d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-11-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Objective: To evaluate dentoskeletal symmetry in cone beam computed tomography (CBCT) scans of Brazilian individuals with Angle class I malocclusion. Materials and methods: Forty seven patients (22 girls) aged 11 to 16 years (14 years) seen in a private radiology service (CIRO, Goiânia, GO, Brazil). All the CBCT images were acquired from January 2009 to December 2010. Cephalometric measurements were made by multiplanar reconstructions (axial, coronal and sagittal) using Vista Dent3DPro 2.0 (Dentsply GAC, New York, USA). The minimum, maximum, mean and standard deviation values were described in tables, and the Student t test was used to define statistical significance (p<0.05). Results: Data were homogeneous, and the differences between right and left sides were not significant. Conclusion: The cephalometric measures of Brazilian individuals with Angle class I malocclusion can be used to define facial symmetry and three-dimensional standard references, which might be useful for orthodontic and surgical planning. / Objetivo: verificar a simetria facial e dentoesquelética por meio de fotografia frontal e tomografia computadorizada de feixe cônico, respectivamente, em indivíduos brasileiros portadores de má oclusão Classe I de Angle. Material e Método: a amostra do estudo foi selecionada de um banco de imagens de 47 pacientes (22 mulheres e 25 homens) com idade entre 11 e 16 anos em um serviço privado de radiologia. Todas as imagens foram obtidas de pacientes com indicação de tratamento ortodôntico no período de janeiro de 2009 a dezembro de 2010. Medidas cefalométricas foram obtidas por meio de reconstruções multiplanares (axial, coronal e sagital) com auxilio do programa Vista Dent3DPro 2.0. O valor mínimo, o máximo, a média e o desvio-padrão das medidas foram determinados e a diferença estatística entre as medidas do lado esquerdo e direito foi analisada por meio do teste-t e Mann-Whitney. Foram considerados significativos valores de p < 0,05. Resultados: As medidas cefalométricas mostraram dados homogêneos. O lado direito e esquerdo exibiram variações nas análises cefalométricas tridimensionais. 61,70% dos pacientes foram considerados simétricos na avaliação fotográfica frontal. Conclusão: Indivíduos brasileiros com classe I de Angle apresentaram simetria facial na maioria dos pacientes, com variações entre o lado direito e esquerdo.
290

Avaliação clínica e radiográfica de pacientes com estenose do canal lombar submetidos a técnica de artrodese lateral minimamente invasiva / Clinic and radiological evaluation of patients with lumbar canal stenosis submitted to lateral minimally invasive technic

Coutinho, Thiago Pereira 30 July 2019 (has links)
Introdução: O acesso lombar transpsoas extremo lateral (LLIF) é uma abordagem retroperitoneal para artrodese intersomática que constitui num implante (cage) o qual se sustenta nas duas margens laterais do anel epifisário, maximizando o apoio na placa terminal. Há também a descompressão indireta das estruturas nervosas através da discectomia e restauro da altura discal pelo cage. Objetivo: Avaliar a eficácia clínica e radiológica da descompressão indireta após o LLIF para estenose do canal lombar. Métodos: Estudo prospectivo clínico e radiológico em único centro, com 20 pacientes portadores de estenose do canal lombar, sem resposta ao tratamento clínico, submetidos à cirurgia de artrodese por via lateral transpsoas minimamente invasiva. Foram coletados dados clínicos e radiológicos no período pré-operatório, em 6 semanas, em três meses, seis e doze meses após a cirurgia. Dados radiológicos medidos em RNM incluíram área e altura dos forâmens, área do canal, diâmetro do canal e altura anterior e posterior do disco intervertebral. Questionários clínicos incluíram EVA e ODI. A incidência de complicações e re-operações foram descritas. Resultados: A idade média do grupo foi de 57,8 anos. Foram tratados ao todo 25 níveis. As cirurgias decorreram sem complicações intra-operatórias. Um caso (5%) recebeu re-operação. A área do canal aumentou de 109 mm para 149mm (p < 0,001) e de 9,3mm para 12,2mm (p < 0,001) em diâmetro anteroposterior. Os valores de área dos forâmens também demonstraram o efeito da descompressão indireta em ambos lados (p < 0,001). A altura do forâmen mostrou ganhos significativos, de 2,8mm de média (p < 0,001). A altura discal foi aumentada em média 25% (p < 0,001). Os resultados de questionários EVA e ODI respondidos pelos pacientes confirmaram o efeito clínico da descompressão indireta demonstrada radiologicamente. Conclusão: Observamos que a descompressão indireta pelo método de LLIF apresenta resultados que comprovam a melhora tanto radiológica quanto clínica com baixa taxa de complicações e re-operações / Background: Lateral transpsoas lateral access (LLIF) is a retroperitoneal approach for intersomatic arthrodesis that constitutes an implant, which is supported on the two lateral margins of the epiphyseal ring, maximizing the support in the terminal plate. There is also indirect decompression of nerve structures through discectomy and restoration of disc height by cage. Aim: Evaluate the clinical and radiological improvement of the indirect decompression after LLIF for lumbar canal stenosis. Methods: Prospective clinical and radiological study in a single center, with 20 patients with lumbar canal stenosis, without response to clinical treatment, submitted to minimally invasive transpsoas lateral lumbar interbody fusion (LLIF) surgery. Clinical and radiological data were collected in the preoperative period, at 6 weeks, at three, six and twelve months after surgery. Radiological data measured on MRI included area and height of foramen, canal area, canal diameter and anterior and posterior height of the intervertebral disc. Clinical questionnaires included VAS and ODI. Complications and re-operations were described. Results: The mean age of the group was 57.8 years. A total of 25 levels were treated. Surgeries were performed without intraoperative complications. One case (5%) received reoperation. The canal area increased from 109 mm to 149 mm (p < 0.001) and from 9.3 mm to 12.2 mm (p < 0.001) in the anteroposterior diameter. The values of the foramen area also demonstrated the effect of indirect decompression on both sides (p < 0.001). The height of the foramen showed significant gains, of 2.8 mm of mean (p < 0.001). Disc height was increased by an average of 25% (p < 0.001). The results of VAS and ODI questionnaires answered by the patients confirmed the clinical effect radiologically demonstrated of indirect decompression. Conclusion: We observed that indirect decompression by the LLIF method is feasible radiologically and clinically with a low rate of complications and reoperations

Page generated in 0.1234 seconds