• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 400
  • 400
  • 400
  • 200
  • 179
  • 91
  • 63
  • 61
  • 59
  • 54
  • 54
  • 49
  • 46
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Validação de imagens panorâmicas digitais para avaliação da morfologia da cabeça da mandíbula por meio de tomografia computadorizada de feixe cônico / Validation of digital panoramic images in the evaluation of mandibular condylar morphology by means of cone-beam computed tomography

Ladeira, Daniela Brait Silva, 1977- 21 August 2018 (has links)
Orientador: Solange Maria de Almeida / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:44:21Z (GMT). No. of bitstreams: 1 Ladeira_DanielaBraitSilva_D.pdf: 1652412 bytes, checksum: 0ae9510fef9efe770e30ce2487fa964d (MD5) Previous issue date: 2013 / Resumo: O objetivo da presente pesquisa foi avaliar a validade da radiografia panorâmica digital para o diagnóstico de alterações morfológicas da cabeça da mandíbula, utilizando as imagens de tomografia computadorizada de feixe cônico (TCFC) como padrão ouro. Foram selecionados exames de 212 indivíduos, que possuíam tanto imagens panorâmicas digitais quanto de TCFC. Nas imagens panorâmicas, 4 avaliadores analisaram a cabeça da mandíbula dos lados direito e esquerdo individualmente, determinando o tipo de alteração observada quando presente. As imagens tomográficas foram avaliadas por 2 radiologistas, que analisaram os cortes coronais e parassagitais de cada cabeça da mandíbula, determinando o tipo de alteração observada. Quando havia discordância entre os resultados do diagnóstico, um terceiro radiologista era consultado. Foram realizadas as análises de concordância, por meio do coeficiente Kappa e análises de desempenho da radiografia panorâmica, utilizando os testes diagnósticos com nível de significância de 5% (? = 0,05). A análise dos resultados mostrou que houve concordância entre os dois métodos, mas a força de concordância nos diferentes grupos variou de moderada a ruim. Já a concordância entre os avaliadores foi fraca. As alterações com baixa prevalência foram erosão, capuz ósseo, concavidade posterior, côndilo bífido e cisto subcondral dos lados direito e esquerdo, e fratura condilar do lado direito, e a acurácia de diagnostico usando a radiografia panorâmica variou de 93,4% a 99,53%. As alterações de maior prevalência foram o osteófito (mais de 30%) e o aplainamento (mais de 80%). Nestes casos a acurácia de diagnostico usando a radiografia panorâmica variou em torno de 40% para o aplainamento condilar, e a sensibilidade para diagnóstico de osteófito variou de 4 a 8%. Concluiu se que a radiografia panorâmica digital tem pouca validade para o diagnóstico de alterações morfológicas da cabeça da mandíbula e não deve ser indicada como método de escolha para diagnóstico nesta região / Abstract: The aim of this study was to assess the validity of digital panoramic radiography to diagnose morphological alterations in the mandible condyle using cone-beam computed tomography images as the gold standard. Examinations of 212 individuals were selected, who had both digital panoramic and cone-beam computed tomographic images. The panoramic images were assessed by 4 examiners who analyzed the mandibular condyle on the right and left sides individually to determine the type of alterations, when present. The tomographic images were assessed by 2 radiologists who analyzed the coronal and parasagittal sections of each mandibular condyle to determine the type of alterations found. When there was disagreement among the diagnostic results, a third radiologist was consulted. The agreement analysis was performed using the Kappa coefficient and the performance analysis of the panoramic radiography was performed using diagnostic tests at a level of significance of 5% (? = 0.05). The results showed that there was agreement between the panoramic and tomographic methods, but strong agreement in the different groups ranged from moderate to poor. The agreement among the examiners for the panoramic method was poor. Low-prevalence alterations were erosion, bony cap, posterior concavity, bifid condyle and subchondral cyst, the right and left sides, and fracture of the right condyle, and the diagnostic accuracy using panoramic radiography ranged from 93.4% to 99.53%. The high-prevalence alterations were osteophyte (approximately 30%) and flattening (approximately 80%). The cases of diagnostic accuracy using panoramic radiography varied 40% for condylar flattening and diagnostic sensitivity for osteophyte ranged from 4 to 8%. It was concluded that digital panoramic radiography has little validity to diagnose morphological alterations of the mandibular condyle and it should not be indicated as the method of choice for diagnosing this region / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica
332

Determinação do tamanho e extensão do infarto agudo do miocárdio pela ecocardiografia com perfusão em tempo real em seres humanos: comparação com a ressonância magnética / Determination of size and extent of acute myocardial infarction by real time myocardial contrast echocardiography in humans: a comparison with magnetic resonance imaging

Maria Luciana Zacarias Hannouche da Trindade 08 July 2005 (has links)
O objetivo da reperfusão mecânica ou medicamentosa em pacientes com infarto agudo do miocárdio (IAM) é a restauração do fluxo sangüíneo na artéria relacionada ao infarto, a fim de limitar a necrose miocelular e preservar a função contrátil, que são os maiores preditores de sobrevida após o IAM. Entretanto, seu sucesso é indicado pela reperfusão nos capilares miocárdicos e não pela recanalização da artéria relacionada ao infarto. A ecocardiografia com perfusão miocárdica em tempo real pode ser usada para avaliar a perfusão nos capilares miocárdicos e estimar o tamanho do infarto em vários estudos experimentais. O objetivo deste estudo foi determinar a área do miocárdio infartado e sua extensão transmural pela ecocardiografia com perfusão miocárdica em tempo real, em pacientes hospitalizados nos primeiros dias após primo infarto agudo do miocárdio, tendo como padrão de referência a ressonância magnética de perfusão. Prospectivamente, foram estudados 20 pacientes (12 homens), com idade média de 64,2 ± 13,3, dentro de 12 horas de reperfusão mecânica ou medicamentosa. Os exames de ecocardiografia e ressonância magnética foram realizados do segundo ao quinto dia de infarto. O contraste \"PESDA (perfluorocarbon-exposed sonicated dextrose albumin)\" foi administrado em veia periférica, na dose de 0,1ml/Kg, em infusão contínua. A análise ecocardiográfica foi feita por uma análise qualitativa (visual) denominada escala de cinza e por uma análise quantitativa, chamada imagem paramétrica. A área de infarto média foi de 3,03 ± 2,77 cm2 para a escala de cinza (r=0,97), de 3,36 ± 2,82 cm2 para a imagem paramétrica (r= 0,99) e de 3,42 ± 2,80 cm2 para a ressonância magnética. O porcentual médio da área de infarto pela ecocardiografia em escala de cinza foi de 15,22% ± 14,84% (r= 0,97), pela imagem paramétrica foi de 16,46% ± 14,41% (r= 0,99) e pela ressonância magnética foi de 16,76% ± 14,48%. A extensão transmural do infarto em cada segmento infartado pela escala de cinza,apresentou uma correlação menor (r=0,77) em relação à imagem paramétrica (r=0,93). Em conclusão, este estudo mostrou uma excelente correlação entre ecocardiografia com perfusão miocárdica em tempo real (sobretudo pela imagem paramétrica) e ressonância magnética nas medidas da área de infarto e seu porcentual, assim como na determinação de sua extensão transmural em pacientes internados por infarto agudo do miocárdio / The aim of mechanical or pharmacological reperfusion in patients with AMI is to restore blood flow through the infarct related artery in order to limit myocellular necrosis and ultimately preserve myocardial contractile function, which is still the most powerful predictor of survival after acute myocardial infarction. The success of reperfusion, however, is indicated by perfusion of myocardial capillaries rather than simply patency of the infarct related artery. Myocardial contrast echocardiography (MCE) can be used to assess myocardial capillary perfusion and ultimately the infarct size in animals. The aim of this study was to determine by MCE the transmural extent and infarct size using magnetic resonance imaging (MRI) as a gold standard. We prospectively studied 20 patients (12 men; mean age 64.2 ± 13.3) admitted for a first acute myocardial infarction, within 12 hours after mechanical or pharmacological reperfusion. The MCE and MRI were performed between the 3rd and 5th day of acute myocardial infarction (AMI). A suspension of 0.1 ml/kg of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) ultrasound contrast agent was administered as a continuous infusion. The interpretation of perfusion images by MCE was assessed by qualitative analysis (visual- VIS) and a quantitative one called parametric image (PI). The average infarct area showed by VIS was 3.03 ± 2.77 cm 2, by PI was 3.36 ± 2.82 cm 2 and by MRI was 3.42± 2.80cm 2. The average percentage of infarct area by VIS was 15.22% ± 14.84%, by PI was 16.46% ± 14.41% and by MRI was 16.76% ± 14.48%. The transmural extent was calculated in each infarcted segment by VIS, with a worse correlation (r=0,77) than PI (r=0,93). In conclusion, this study showed that MCE, in special PI, correlates well with MRI in detecting infarct size, percentage of infarct size and transmural extent in patients with acute myocardial infarction
333

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.
334

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.
335

Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas / Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeries

Tonelotto, Bruno Francisco de Freitas 03 December 2018 (has links)
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar / Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
336

Avaliação do seio maxilar e estruturas adjacentes em indivíduos edêntulos total ou parcial na região posterior da maxila / Evaluation of the maxillary sinus and adjacent structures in total or partial edentulous individuals in the posterior maxila

Terrero Perez, Angel 03 April 2018 (has links)
Os seios maxilares são os maiores seios paranasais e seu desenvolvimento apresenta uma variabilidade entre os indivíduos, já que sofre um processo de expansão progressiva durante a vida toda, principalmente nos casos de perdas dentárias, provocando pneumatização do seio em direção ao rebordo alveolar, reduzindo sua altura. Quando essa altura óssea alveolar residual é insuficiente, uma cirurgia de levantamento de seio pode ser realizada para ganhar altura óssea e posterior instalação de implantes dentários. Em alguns casos, podem apresentar variações anatômicas, levando ao insucesso da técnica cirúrgica, por desconhecimento ou falta de planejamento através de exames complementares. Para evitar esse tipo de acidentes e complicações em implantodontia é preciso a ajuda de exames complementares para um melhor planejamento cirúrgico e protético, como é o caso da tomografia computadorizada de feixe cônico, que fornece imagens em três dimensões, possibilitando uma melhor avaliação do seio maxilar. Portanto, o objetivo deste estudo foi descrever as diferentes variações anatômicas apresentadas no seio maxilar em pacientes edêntulos total e parcial da região posterior da maxila, realizar mensurações do osso alveolar residual, paredes do seio e determinar a relação da artéria alveolar superior posterior com o seio maxilar, através da avaliação de tomografia computadorizada de feixe cônico disponíveis nos arquivos de imagens digitais do departamento de Cirurgia, Estomatologia, Patologia e Radiologia da Faculdade de Odontologia de Bauru da Universidade de São Paulo FOB/USP. / The maxillary sinus is the largest of the paranasal sinuses and its development presents a variability among the individuals, since it undergoes a process of progressive expansion during the whole life, mainly in the cases of dental losses, provoking pneumatization of the sinus toward the alveolar ridge, reducing your Height. When this residual alveolar bone height is insufficient, a sinus lift surgery can be performed to gain bone height and subsequent installation of dental implants. In some cases, they may present anatomic variations, leading to the failure of the surgical technique, due to lack of knowledge or lack of planning through complementary tests. To avoid such accidents and complications in implantology, it is necessary the help of complementary examinations for a better surgical and prosthetic planning, as is the case of conical beam CT, which provides images in three dimensions, allowing a better evaluation of the maxillary sinus. Therefore, the objective of this study was to describe the different anatomical variations presented in the maxillary sinus in total and partial edentulous patients of the posterior maxillary region, to perform measurements of the residual alveolar bone, sinus walls and to determine the relation of the posterior superior alveolar artery with the sinus maxillary, through the evaluation of conical beam computed tomography available in the digital images archives of the Department of Surgery, Stomatology, Pathology and Radiology of the Faculty of Dentistry of Bauru of the University of São Paulo FOB / USP.
337

Contribuição dos métodos de imagem no estudo das glândulas suprarrenais em pacientes com hiperplasia congênita de suprarrenal, com ênfase nas técnicas quantitativas por ressonância magnética / The role of imaging in evaluation of the adrenal glands in congenital adrenal hyperplasia, with an emphasis on quantitative magnetic resonance imaging

Teixeira, Sara Reis 02 September 2014 (has links)
Hiperplasia congênita de suprarrenal (CAH) compreende um grupo de transtornos hereditários decorrentes de erros inatos do metabolismo dos esteróides adrenais. O aumento das dimensões das glândulas suprarrenais é um marco morfológico na CAH que pode ser avaliado por métodos de imagem com signifitiva correlação com o controle hormonal dos pacientes. Porém, técnicas de imagem que forneçam informações qualitativas e quantitativas relativas à citoarquitetura das glândulas ainda não foram estabelecidas neste contexto. A difusão por ressonância magnética (DWI) é uma técnica que pode fornecer informações quantitativas dos tecidos através do valor do coeficiente de difusão aparente (ADC). O papel do ADC na avaliação de lesões tumorais adrenais já foi estudado, no entanto, o valor do ADC das glândulas suprarrenais normais ainda não foi descrito. O objetivo geral desta tese foi investigar a utilidade dos métodos de imagem na avaliação da CAH. Os objetivos específicos foram apresentar uma revisão dos métodos por imagem já estabelecidos para avaliação da CAH, validar o cálculo do ADC da glândula suprarrenal e avaliar se o ADC e as dimensões das glândulas suprarrenais poderiam auxiliar no manejo de pacientes com CAH, correlacionando-os com controle hormonal. Esta tese é baseada em artigos, nos quais estão mostrados a metodologia, resultados e discussões relativos a cada uma das etapas. O primeiro artigo, The role of imaging in congenital adrenal hyperplasia, trata de uma revisão sistemática de imagem em CAH, com ênfase em genitografia, ultrassonografia, tomografia computadorizada e ressonância magnética (MRI). O segundo artigo, Apparent Diffusion Coefficient (ADC) of the normal adrenal glands: premilinary results, teve como principal objetivo validar o método de medida do ADC das glândulas suprarrenais. No terceiro artigo, Quantitative magnetic resonance imaging in the evaluation of adrenal glands in children and young adults with congenital adrenal hyperplasia due to 21-hydroxylase deficiency, foram estudados os parâmetros quantitativos por MRI (ADC, volume e medidas lineares) das glândulas suprarrenais que poderiam estar relacionados ao controle hormonal dos pacientes com CAH. Medir o ADC das suprarrenais normais é factível e reprodutível. Em indivíduos saudáveis após a adrenarca o ADC é significativamente menor. Todavia, o ADC não foi capaz de diferenciar indivíduos controles de pacientes com CAH, assim como não apresentou correlação com o status hormonal dos pacientes. O volume e as medidas lineares das glândulas adrenais foram os melhores parâmetros quantitativos por MRI para diferenciar pacientes de indivíduos controles, com correlação positiva com o status hormonal recente dos pacientes com CAH. As dimensões das glândulas suprarrenais avaliadas por MRI podem ser utilizadas como ferramenta auxiliar no acompanhamento dos pacientes e mostrar rapidamente os efeitos da exposição a altos níveis de hormônio adrenocorticotrópico. Apesar de ocorrerem modificações celulares na CAH e de ter sido mostrado neste estudo que em pacientes sem doença hormonal conhecida o ADC é mais baixo após a adrenarca, estas alterações celulares que ocorrem na CAH não foram detectadas pelas medidas de ADC. / Congenital adrenal hyperplasia (CAH) is an autossomic recessive disorder caused by impaired steroidogenesis. A morphological hallmark in CAH is enlarged adrenal glands. Imaging studies have addressed mainly morphological aspects and dimensions of the adrenal glands, which correlate to the patients hormonal statuses. However, no imaging technique was used to evaluate changes in the adrenal glands at a cellular level in these patients. Diffusion-weighted magnetic resonance imaging (DWI) is a magnetic resonance imaging (MRI) technique with the ability to provide quantitative information about intracellular and extracellular space, given by the apparent diffusion coefficient (ADC) values. The role of ADC in evaluation of adrenal lesions has already been studied. However, ADC of the normal adrenals has not yet been described. The main purposes of this study were: to investigate the role of imaging in CAH, to validate the method of calculating ADC values of the normal adrenal glands and to assess hormonal status in patients with CAH and its correlation to quantitative MRI. This is an article-based thesis divided in three articles. The first article, The role of imaging in congenital adrenal hyperplasia, is a systematic review of imaging in congenital adrenal hyperplasia, with emphasis on genitography, ultrasonography, computed tomography and MRI. The article Apparent diffusion coefficient (ADC) of the normal adrenal glands: premilinary results aimed to validate the method of measuring ADC of the adrenal glands. The study of quantitative parameters (ADC, volume and linear measurements) of the adrenals evaluated by MRI that correlate with hormonal status in patients with CAH is described in the third article, Quantitative magnetic resonance imaging in evaluation of the adrenal glands in children and young adults with congenital adrenal hyperplasia due to 21-hydroxylase deficiency. Measuring ADC of the normal adrenal glands is feasible and reproducible. In healthy subjects, ADC values were significantly lower after adrenarche. However, neither a difference between ADC values of controls and patients, nor correlations with patients hormonal statuses were found. Volume and linear measurements of the adrenal glands were the best parameter to differentiate patients from controls. Moreover, a positive correlation was found between short-term hormonal control status and adrenal size. Adrenal size assessed by MRI might be a useful tool in the follow-up of patients with CAH. Although adrenal cell structure modifications in patients with CAH have been described, they were not detectable by DWI.
338

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Medeiros, Felipe de Araujo Andrade 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
339

Estudo das alterações inflamatórias dos seios maxilares por meio da análise qualitativa e quantitativa da difusibilidade das moléculas de água em ressonância magnética / Inflammatory alterations of the maxillary sinuses by qualitative and quantitative analysis of the water molecules diffusibility in magnetic resonance imaging

Munhoz, Luciana 08 June 2018 (has links)
Os seios maxilares constituem cavidades multifuncionais que apresentam íntima relação como elementos dentários súpero-posteriores e/ou o osso alveolar desta região, tornando-os susceptíveis a infecções de origem odontológica; ou, mediante a presença de sinusopatias de diversas naturezas, resultando em insucesso de procedimentos de abordagem direta destes ou em áreas adjacentes. O estudo imaginológico das cavidades dos seios maxilares previamente a procedimentos odontológicos na região dos seios maxilares é indispensável para garantir-se a evolução pós-operatória favorável. A anatomia complexa destas cavidades requer o uso de ferramentas tridimensionais, como a tomografia computadorizada e a ressonância magnética. Recentemente, novas modalidades técnicas, objetivando otimizar o diagnóstico por ressonância magnética, tem sido investigadas em processos patológicos diversos, incluindo aqueles que podem acometer os seios maxilares. Uma dessas modalidades, é o estudo qualitativo e quantitativo da difusibilidade das moléculas de água, que propõe-se a descrever características celulares e funcionais de tecidos, sob o ponto de vista imaginológico. Essencialmente, a ideia do estudo da celularidade e fisiologia dos tecidos é distinguir processos patológicos diferentes, provendo hipóteses diagnósticas acuradas. Não obstante, existem poucos estudos que analisam as doenças inflamatórias e infecciosas dos seios maxilares, que são as afecções mais usuais nestas cavidades. Assim sendo, o objetivo primordial deste estudo foi analisar os valores quantitativos dos coeficientes de difusibilidade das moléculas de água (ADC) em grupos de alterações imaginológicas nos seios maxilares que correspondem à sinais imaginológicos de sinusopatias inflamatórias e/ou infecciosas, afim de verificar se existem diferenças significativas entre estes valores que poderiam auxiliar no diagnóstico por meio da ressonância magnética. Para desenvolver este objetivo, foram analisados 98 seios maxilares de pacientes que realizaram exames de ressonância magnética, classificando as alterações observáveis nesta cavidade em 4 grupos: presença de espessamento da mucosa sinusal, pólipos ou cistos, nível hidroaéreo, presença de conteúdo de sinal heterogêneo em imagens ponderadas em T2 associado a erosões ósseas e presença de calcificações distróficas. Os valores de ADC foram aferidos nos seus respectivos mapas de ADC. Diferenças estatisticamente significativas foram verificadas comparando-se os 4 grupos; ademais, os seios maxilares foram classificados de acordo com o grau de acometimento destas alterações em: ausência de opacificação, totalmente opacificado, parcialmente opacificado e presença de espessamento da mucosa sinusal. Verificou-se que o grau de opacificação mais prevalente na amostra estudada foi o parcialmente opacificado. Os valores de ADC do espessamento da mucosa sinusal são estatisticamente menores do que os dos demais grupos, indicando menor difusibilidade das moléculas de água do espessamento em relação às demais alterações. Concluiu-se que é possível utilizar os valores de ADC na diferenciação do espessamento da mucosa sinusal das demais alterações dos seios maxilares. / The maxillary sinuses are multifunctional cavities closed related with upper- posterior teeth and / or this region alveolar bone, which can lead to susceptibility to sinusal dental origin infections; or, due to the sinus disease, leading to failure in sunuses direct approach or in adjacent areas procedures. The imaging study of maxillary sinus cavities prior to procedures in the region of the maxillary sinuses is indispensable to ensure favorable postoperative evolution. The complex anatomy of these cavities requires the use of three-dimensional tools, such as computed tomography and magnetic resonance imaging. Recently, new technical modalities aiming to optimize the diagnosis by magnetic resonance have been investigated in diverse pathological processes, including those that can affect the maxillary sinuses. One of these modalities is the qualitative and quantitative study of the diffusibility of water molecules, which proposes to describe celularity and functional characteristics of tissues from an imaginary point of view. Essentially, the idea cellularity and tissue physiology study is to distinguish different pathological processes, providing accurate diagnostic hypotheses. Nevertheless, there are few studies that analyze the inflammatory and infectious diseases of the maxillary sinuses, which are the most common affections in these cavities. Thus, the main objective of this study was to analyze the quantitative values of the water molecule diffusibility coefficients (ADC) in groups of imaging alterations in the maxillary sinuses that correspond to signs of inflammatory and / or infectious sinusopathies, in order to verify if there are any significant differences between these values that could aid in the diagnosis through magnetic resonance imaging. To develop this objective, 98 maxillary sinuses of patients that underwent magnetic resonance imaging were evaluated. The maxillary sinuses were classified according to the inflammatory / infectious changes detected in 4 groups: presence of sinus mucosal thickening, polyps or cysts, air-fluid levels, T2 weighted heterogeneous signal associated with erosions and the presence of dystrophic calcifications. The ADC values were measured on their respective ADC maps. Statistically significant differences were observed comparing the 4 groups; In addition, the maxillary sinuses were classified according to the degree of involvement of these alterations in: absence of opacification, totally opacified, partially opacified and presence of mucous thickening. It was verified that the most prevalent degree of opacification in the studied sample was partially opacified. ADC values of the sinus mucosa thickening are statistically lower than those of the other groups, indicating less diffusibility of the thickening water molecules in relation to the other alterations. It was concluded that it is possible to use the ADC values in the differentiation of the mucous thickening of the other alterations of the maxillary sinuses.
340

Sistematização da percepção médica na construção de sistemas para recuperação de imagens por conteúdo / Systematization of medical perception in implementing of content-based image retrieval systems

Silva, Marcelo Ponciano da 27 February 2014 (has links)
Nos últimos anos o mundo tem vivenciado uma avalanche de novas tecnologias para auxílio ao diagnóstico médico. Esses esforços buscam um diagnóstico rápido e preciso através de exames e informações sobre a condição física do paciente. Através do uso de imagens médicas, a radiologia busca a visualização de órgãos ou estruturas internas do corpo humano para encontrar respostas às suspeitas de problemas físicos expressos por sinais e sintomas relatados pelo paciente. Nessa área, os Sistemas de Comunicação e Armazenamento de Imagens (PACS) têm ajudado no armazenamento e organização do crescente número de imagens geradas pelos exames realizados nos hospitais. Trabalhos de pesquisa médica têm evidenciado o potencial de uso dessas imagens como auxílio à prática da Medicina Baseada em Casos Similares (MBCS). Por esse motivo, há na literatura um esforço contínuo em desenvolver técnicas computacionais para recuperação de imagens baseada em conteúdos similares (CBIR) em grandes conjuntos de dados. As consultas por similaridade são essenciais para apoiar a prática da MBCS e a descoberta de comportamentos de lesões causadas por diversas doenças. A evolução e intensificação das pesquisas em CBIR têm encontrado vários desafios. Um desses é a divergência entre os resultados obtidos automaticamente e aqueles esperados pelos radiologistas (descontinuidade semântica). Outro desafio é a falta de estudos sobre a viabilidade clínica dessas ferramentas como forma de auxílio ao diagnóstico. Esses obstáculos são dois dos principais responsáveis pela não efetivação dessa tecnologia no ambiente médico-hospitalar. Mediante o exposto acima, este trabalho de pesquisa propõe um mecanismo para contornar essa descontinuidade semântica e ao mesmo tempo aproximar o CBIR do ambiente real de aplicação. A contribuição principal deste trabalho foi o desenvolvimento de uma metodologia baseada em parâmetros perceptuais que aproximam o sistema ao nível de percepção do usuário médico. Em seguida, foi realizado um estudo sobre a viabilidade clínica do sistema CBIR no Hospital das Clínicas de Ribeirão Preto. A metodologia proposta foi aplicada e os resultados comprovaram a aplicabilidade de Sistemas CBIR como ferramenta de auxílio ao diagnóstico em um ambiente clínico real / In recent years the world has experienced an avalanche of new technologies to aid medical diagnosis. These efforts seek a quick and accurate diagnosis through exams and information about the patient\'s physical condition. The radiology studies the visualization of the organs or structures through the use of images. In this area, the Picture Archiving and Communication Systems (PACS) have helped in the storage and organization of the growing number of images generated by exams performed in hospitals. Medical research papers have shown the potential use of these images as an aid to the Similar Case-Based Reasoning (SCBR) practice in Medicine. For this reason, there is an ongoing effort in the literature to develop computational techniques for Content-Based Image Retrieval (CBIR) in large data sets. Similarity queries are essential to support the practice of SCBR. The evolution and intensification of research in CBIR have encountered several challenges. One of these is the discrepancy between the results obtained automatically and those expected by radiologists (semantic gap). Another challenge is the lack of studies on the clinical viability of these tools as a way to assist in diagnosis. These obstacles are the two main responsible for reservation in using this technology in the medical hospital environment. Considering this scenario, this research proposes a mechanism to overcome this semantic gap and bring the real environment to the CBIR application. The main contribution for this research was the development of a methodology based on Perceptual Parameters to approximate the system to the level of user perception. Then we conducted a study on the clinical viability of a CBIR system at the Clinical Hospital of the University of São Paulo at Ribeirão Preto. The proposed methodology was applied and the results showed the applicability of CBIR systems as a computer aided diagnosis tool in a real clinical environment

Page generated in 0.0938 seconds