• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 4
  • Tagged with
  • 79
  • 64
  • 33
  • 32
  • 15
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Desenvolvimento de um sensor capacitivo de medição da massa específica de sementes para automação da mesa de gravidade / Development of a capacitive sensor to measure the specific gravity of seeds for automation of the gravity table,

Araújo, Ádamo de Sousa 01 March 2017 (has links)
Submitted by Gabriela Lopes (gmachadolopesufpel@gmail.com) on 2018-07-17T18:53:09Z No. of bitstreams: 1 Tese - Ádamo Araújo.pdf: 1178543 bytes, checksum: 202c2d206529085740d4a2fd31f87d53 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-07-17T21:43:50Z (GMT) No. of bitstreams: 1 Tese - Ádamo Araújo.pdf: 1178543 bytes, checksum: 202c2d206529085740d4a2fd31f87d53 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-07-17T21:46:16Z (GMT) No. of bitstreams: 1 Tese - Ádamo Araújo.pdf: 1178543 bytes, checksum: 202c2d206529085740d4a2fd31f87d53 (MD5) / Made available in DSpace on 2018-07-17T21:49:04Z (GMT). No. of bitstreams: 1 Tese - Ádamo Araújo.pdf: 1178543 bytes, checksum: 202c2d206529085740d4a2fd31f87d53 (MD5) Previous issue date: 2017-03-01 / A automação das operações unitárias de beneficiamento de sementes é uma necessidade real para aperfeiçoar o funcionamento, a operação e o ajuste das máquinas. A massa específica das sementes pode apresentar associação com o vigor, pois sementes com problema de enchimento, atacadas por insetos ou até mesmo quebradas, sofrem redução da massa específica, consequentemente decréscimo de qualidade fisiológica do lote de sementes. O objetivo do trabalho foi desenvolver um sensor capacitivo para medição da massa específica de sementes e analisar a associação entre a permissividade dielétrica relativa e a qualidade fisiológica de sementes beneficiadas em mesa de gravidade. No experimento empregaram-se sementes de soja e de coentro. Foi utilizado a correlação de Pearson para analisar as variáveis de massa específica (), teor de água () e temperatura () com a permissividade dielétrica relativa total (), real (′) e imaginária (′′) nas frequências de 1 kHz, 10 kHz e 100 kHz. A correlação de Pearson foi utilizada para análise da associação entre a permissividade relativa e os atributos fisiológicos e físicos das sementes. A permissividade dielétrica relativa, atributos fisiológicos e físicos foram submetidos a análise de variância e, se significativos, as variáveis foram comparadas pelo teste de Tukey a 5% de probabilidade. Houve alta correlação entre as variáveis com as permissividades relativas analisadas em quase todas as frequências, contudo, há uma melhora na estabilidade dos dados com ao aumento da frequência. O sensor mostrou-se eficiente para a determinação da massa específica das sementes, conhecendo previamente o teor de água e a temperatura das sementes. Pelo do teste de Tukey a permissividade relativa permitiu o ranqueamento das bicas de descarga, semelhante aos atributos fisiológicos e físicos exceto a emergência. A regressão linear indicou que com aumento da frequência melhora na conformidade de valores de permissividade. O sensor mostrou-se relativamente eficiente para a determinação da massa específica. / The automation of unit operations for seed processing is a real necessity to improve the operation, operation and adjustment of the machines. The specific gravity of the seeds may be associated with vigor, because seeds with problems of filling, attacked by insects or even broken, suffer a reduction of the specific gravity, consequently a decrease in the physiological quality of the seed lot. The objective of this work was to develop a capacitive sensor to measure the specific gravity of seeds and analyze the association between the relative dielectric permittivity and the physiological quality of seeds benefited in a gravity table. In the experiment soybean and coriander seeds were used. Pearson correlation was used to analyze the variables of specific gravity (ρ), water content () and temperature () with the total relative (), real (′) and imaginary (ε'') In the frequencies of 1 kHz, 10 kHz and 100 kHz. Pearson correlation was used to analyze the association between relative permittivity and the physiological and physical attributes of the seeds. Relative dielectric permissiveness, physiological and physical attributes were submitted to analysis of variance and, if significant, the variables were compared by the Tukey test at 5% probability. There was a high correlation between the variables with the relative permissivity analyzed at almost all frequencies, however, there is an improvement in the stability of the data with increasing frequency. The sensor was efficient for the determination of the specific gravity of the seeds, previously knowing the water content and the temperature of the seeds. By the Tukey's test the relative permissiveness allowed the rank of discharge nozzles, similar to the physiological and physical attributes except emergency. The linear regression indicated that with increasing frequency, the compliance of permissiveness values improved. The sensor was relatively efficient for determining the specific gravity.
72

Desempenho do reflectômetro no domínio do tempo na detecção de variações de umidade do solo. / Performance of a time domain reflectometer in the detection of soil moisture variations.

Gilberto Oliveira Joaquim Júnior 21 July 2003 (has links)
O objetivo do trabalho foi avaliar o desempenho do reflectômetro no domínio do tempo (TDR) comparativamente ao tensiômetro com manômetro de mercúrio (considerado como instrumento padrão), dando-se ênfase na sensibilidade de detecção de variações na umidade do solo sob condições de molhamento e secagem. Foi instalado um experimento em um solo classificado como Nitossolo Vermelho distrófico latossólico de textura muito argilosa, localizado próximo ao Posto Meteorológico do Departamento de Ciências Exatas, ESALQ/USP, Piracicaba (SP), Brasil, 22 o 42’ 30’’ de latitude sul e 47 o 38’ 00’’ de longitude oeste. Com dados de um ensaio de determinação da condutividade hidráulica do solo pelo Método do Perfil Instantâneo, de um período de secagem e de inundações intermitentes do solo, analisou-se a concordância entre a constante dielétrica obtido pelo TDR e o potencial matricial da água no solo obtido pelo tensiômetro, além dos valores de umidade volumétrica obtidos pelas mesmas técnicas. Concluiu-se que o desempenho do TDR foi superior ao do tensiômetro sob condições de secagem do solo e na detecção de variações de umidade. / The performance of a time domain-reflectometer (TDR) was compared with a mercury tensiometer (considered to be the norm), emphasizing the detection of variations in soil water content under wetting and drying conditions (as in instantaneous profile method to determine soil hydraulic conductivity). An experiment was performed in a Nitossolo Vermelho distrófico latossólico argiloso (Brazilian classification system), close to the meteorological observatory of the ESALQ/USP, Piracicaba (SP), Brazil, latitude 22 o 42’30’’ S, longitude 47 o 38’00’’ W. Data of matric potential, dieletric constant and water content during a dry period and water application were analyzed. The TDR cable tester was better than the tensiometer to detect the soil moisture variation.
73

SENSOR CAPACITIVO PARA MONITORAMENTO DO TEOR DE ÁLCOOL ETÍLICO ANIDRO COMBUSTÍVEL (AEAC) EM AMOSTRAS DE GASOLINA COMERCIAL / CAPACITIVE SENSOR FOR MONITORING OF THE LEVEL OF ANHYDROUS ETHYL ALCOHOL FUEL (AEAF) IN SAMPLES OF COMMERCIAL GASOLINE

Souza, Darlan Carvalho de 12 July 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:45Z (GMT). No. of bitstreams: 1 Dissertacao Darlan.pdf: 2834733 bytes, checksum: f7d35c098bddf8713fbdbe733565fdef (MD5) Previous issue date: 2013-07-12 / During several years, adulterated gasoline has been commercialized across all Brazil. Often such product has higher alcohol content, water traces or organic solvents insertion (e.g. paint thinner and/or turpentine). The use of nonconforming gasoline, in the short and long terms, has several problems for consumers, for the vehicle and the environment. Thus, this work aims to propose a low cost technique for analyzing gasoline blends, in relation to its oxygenated addition. Both capacitance and dielectric constant (relative permittivity) were determined by means of a high precision LCR-meter, using a metal concentric sensor. Therefore, gasoline blends were prepared by adding 16, 18, 20, 22, 24, 26, 28 and 30% of AEAF to the initial petroleum-based fuel and their dielectric constants were measured at frequencies of 0.3, 0.4, 0.5 and 0.6 kHz. The same samples were analyzed by the reference method, the Test Tube Test. According to statistical modeling, the frequency of 0.6 kHz showed the most significant results for all samples. The results show that at 95% confidence level, there is no significant difference between the two methods, indicating a good correlation between the proposed method and then standard one. However, when the density was used as evaluating parameter, instead of dielectric constant, for the same samples, a substantial discrepancy of the obtained values were observe, suggest a low sensibility of such methodology. / Vários são os casos de não conformidade da gasolina comercial, principalmente pelo excesso de etanol, ou ainda pela adição de água ou solventes leves como thinner e aguarrás. O uso de gasolina não conforme, a curto e longo prazo, traz diversos problemas para o consumidor, para o veículo e ao meio ambiente. No presente trabalho estudou-se a qualidade da gasolina tipo C, comercializada nos postos revendedores de combustível, no que diz respeito à concentração de álcool etílico anidro combustível (AEAC). Análises estas, realizadas através de medidas de constante dielétrica (permissividade relativa) utilizando sensor capacitivo. Misturas de gasolina A e AEAC foram preparadas nas concentrações de 16, 18, 20, 22, 24, 26, 28 e 30% de AEAC, sendo suas constantes dielétricas medidas nas frequências de 0,3; 0,4; 0,5 e 0,6 kHz. Utilizando tratamento estatístico verificou-se que a frequência de 0,6 kHz apresentou resultados mais significativos para leitura de AEAC das misturas preparadas. Nessa mesma frequência, amostras comerciais de gasolina e amostras de gasolinas não conformes contaminadas com gasolina A e AEAC foram submetidas à análise. As mesmas amostras foram submetidas à análise pelo método de referência, o Teste da Proveta. Os resultados obtidos mostram que, no nível de confiança de 95%, não há diferença significativa entre os dois métodos. Medidas de massas específicas também foram realizadas com as misturas gasolina A e AEAC (16 a 30%) para modelamento de curva de calibração com finalidade de determinar o teor de AEAC e posterior comparação com os resultados oriundos da constante dielétrica e do teste da proveta, entretanto, o método não se mostrou eficiente para análise das amostras de gasolina comercial e amostras de gasolinas não conformes analisadas.
74

Avaliação de uma sonda TDR helicoidal para a estimativa do teor de umidade de solos em campo e laboratório / Evaluation of a helicoidal TDR probe to estimate the soil water content in laboratory and in situ

Cleber Decarli de Assis 09 May 2008 (has links)
Este trabalho de pesquisa apresenta a avaliação de uma sonda TDR helicoidal para estimar o teor de umidade dos solos, em diferentes profundidades, através da técnica da reflectometria no domínio do tempo (TDR). Essa sonda, desenvolvida especificamente para esse fim, foi devidamente calibrada em laboratório para diferentes tipos de solo. O processo de calibração consistiu na determinação da constante dielétrica aparente (Ka) e condutividade elétrica volumétrica (ECb) de um mesmo solo com diferentes teores de umidade. Posteriormente foram buscadas correlações entre Ka e o teor de umidade gravimétrico (w), obtido em estufa. São propostas correlações entre w e Ka, entre w e \'KA POT. 1/2\' e entre teor de umidade volumétrico (\'teta\') e Ka. Também foram consideradas as correlações propostas por Yu e Drnevich (2004), visando estimar também a massa específica seca dos solos. Foram realizados ensaios de campo para a validação das equações de calibração. Os valores dos teores de umidade estimados através da técnica da reflectometria no domínio do tempo, tanto em laboratório como em campo, foram comparados com os valores de teor de umidade obtidos com o método da estufa. Com base nos resultados foram determinados os erros referentes às calibrações. Nos ensaios de campo, os teores de umidade obtidos através da correlação entre w e \'KA POT. 1/2\' apresentaram melhores resultados, quando comparados com aqueles estimados com as outras correlações. Pelos resultados obtidos conclui-se que a técnica TDR é uma alternativa viável para a estimativa em campo do teor de umidade em grandes profundidades. / In this work is presented the evaluation of a recently developed helicoidal probe used for estimating the soil water content through the time domain technology (TDR). This probe has been calibrated in laboratory for different types of soils. The calibration process consisted in assessing the values of the apparent dielectric constant (Ka) and the bulk electric conductivity (ECb) of a specific soil at different levels of water content (w). Subsequently, correlations between the apparent dielectric constant and the water content have been established. The same has done with the bulk electric conductivity. Correlations between Ka and w, \'KA POT. 1/2\' and w, \'teta\' (volumetric water content) and Ka have been proposed. Also, the correlations proposed by Yu and Drnevich (2004) have been considered. To validate the proposed correlations, tests using the helicoidal probe were performed in the field. Estimated values of field water content, using the TDR technology have been compared to the correspondent oven water content values. Based on these comparisons, errors regarding the calibrations have been calculated. In the field tests, the correlations between \'KA POT. 1/2\' and w have presented more accurate results than those obtained with the other correlations. Experimental results have shown that the TDR technology for estimating water content at different depths in the field is feasible and expedite.
75

Dielectric barrier discharge plasma actuators applied to high-lift devices for aerodynamic noise reduction / Atuadores de plasma de descarga de barreira dielétrica aplicados a dispositivos hipersustentadores para redução de ruído aerodinâmico

Silva, Gabriel Pereira Gouveia da 15 February 2019 (has links)
Since the 1970s, when the reaction engines had their noise reduced by the increase in their bypass ratio, airframe became the most prominent aerodynamic noise source during the approach to landing. From the airframe noise sources, the high-lift devices are one of the most significant. The most studied and applied solutions for these noise sources refer to passive flow control, and there are relatively few studies related to active flow control. Active flow control is achieved by adding energy to the flow in order to manipulate it. One way to accomplish this is through the dielectric barrier discharge plasma actuators. These devices create an intense electric field between two electrodes separated by a dielectric. This strong electric field ionizes and accelerates the air through collision of charged particles of the plasma with neutral air molecules. Thus, a wall jet is produced without using moving parts. In this research, plasma actuators were installed at the flap side edge, at the cove and at the cusp of the slat. Wind tunnel tests have demonstrated the potential of these devices for high-lift noise reduction, allowing for a decrease up to 0.75 dB in the overall flap noise and up to 3.3 dB in overall slat noise (with a reduction of 12 dB at the higher peak). / Desde a década de 1970, quando os motores a reação tiveram seu ruído reduzido devido ao aumento da razão de derivação, o ruído de célula se tornou o mais proeminente durante a fase de aproximação para pouso. Do ruído de plataforma aeronáutica, destacam-se os ruídos gerados pela interação do escoamento com os dispositivos hipersustentadores. As soluções mais estudadas e aplicadas para estas fontes de ruído se referem a controle passivo do escoamento, havendo relativamente poucos estudos relacionados a controle ativo. Controle ativo do escoamento é obtido adicionando-se energia ao mesmo, e uma forma de realizar isto é através dos atuadores de plasma de descarga de barreira dielétrica. Nestes dispositivos um intenso campo elétrico entre dois eletrodos separados por um dielétrico é gerado, ionizando e acelerando o ar através da colisão de partículas carregadas do plasma com moléculas neutras. Desta forma, um jato de parede é produzido sem o uso de partes móveis. Nesta pesquisa, atuadores de plasma foram instalados na borda lateral do flape, na cova e na cúspide do eslate. Ensaios em túnel de vento demonstraram o potencial destes dispositivos para redução de ruído de hipersustentadores, permitindo a redução de até 0.75 dB no ruído global de flape e de até 3.3 dB no ruído global de eslate (com redução de 12 dB no maior pico).
76

Desenvolvimento de uma sonda TDR helicoidal para uso em conjunto com o ensaio CPT / Developing a coil TDR probe to use together with the CPT test

Guerrero Doria, Katerin 21 August 2015 (has links)
A reflectometria no domínio do tempo permite estimar o teor de umidade de um meio através da sua correlação com a constante dielétrica. Uma sonda helicoidal TDR, que pode ser cravada em conjunto outros ensaios de penetração in situ para a estimativa do teor de umidade em diversas profundidades, tem aplicação interessante para a investigação geotécnica do subsolo. No presente trabalho, uma sonda TDR foi adaptada e utilizada em conjunto ao ensaio CPT para caracterização de um perfil de solo arenoso não saturado que ocorre na região de Bauru (SP). A calibração dessa sonda foi feita em laboratório especificamente para esse solo. As equações de calibração que mostraram os melhores resultados foram definidas correlacionando a constante dielétrica, condutividade elétrica aparente e a massa específica seca com o teor de umidade. Com o intuito de melhorar a acurácia na determinação do teor de umidade em campo e eliminar possíveis interferências no registro da onda eletromagnética, foram efetuadas modificações em algumas características do projeto original dessa sonda. Tais modificações consistiram em separar os eletrodos condutores e as partes metálicas da sonda, e eliminar o cabo coaxial de extensão, conectando a sonda diretamente a um cabo coaxial de 12 m de comprimento. Tais mudanças levaram a uma melhoria significativa na determinação do perfil de teor de umidade do local estudado. Os valores de teor de umidade de campo determinados usando o TDR ao longo de 8 m de profundidade foram comparados com os valores de referência obtidos de amostras deformadas retiradas com trado mecânico. O erro médio na estimativa do perfil de teor de umidade gravimétrico utilizando a sonda TDR helicoidal foi de 1.61%, na última campanha de ensaios realizados. Os resultados dessa pesquisa indicam que esta ferramenta é adequada para estimar do perfil de teor de umidade para uso em conjunto com o ensaio CPT. / The time domain reflectometry allows estimating the moisture content of a medium by means of its correlation with the dielectric constant. A coil TDR probe, which can be driven into the ground together with others in situ penetration tests, can be used to estimate the moisture content at different depths. It is an interesting approach for geotechnical site characterization. In this work, a coil TDR probe was adapted and used in combination with the CPT test for the site characterization of an unsaturated sandy soil profile which occurs in the region of Bauru (SP). The probe calibration was performed in laboratory specifically for that soil. The calibration equation, which presented the best results, were defined correlating the dielectric constant, electrical conductivity and dry density with the moisture content. In order to improve the accuracy for determining the water content in the field and to eliminate possible interference on the electromagnetic wave registration, modifications were made in some characteristics of the original design of this probe. Such modifications consisted in separating the conductive electrodes from the metal parts of the probe, and eliminating the coaxial extension cable, connecting the probe directly to a coaxial cable 12 m long. Such changes have led to a significant improvement in the determination of the moisture content profile of the studied site. The moisture content values determined in situ by using the TDR along 8 m depth were compared with reference values obtained from disturbed soil samples collected using mechanical augers. The root mean square error of the gravimetric water content profile using the TDR coil probe was 1.61% in the last test campaign. The results of this research indicate that this tool is suitable to estimate the gravimetric moisture content together with the CPT test.
77

Desenvolvimento de uma sonda TDR helicoidal para uso em conjunto com o ensaio CPT / Developing a coil TDR probe to use together with the CPT test

Katerin Guerrero Doria 21 August 2015 (has links)
A reflectometria no domínio do tempo permite estimar o teor de umidade de um meio através da sua correlação com a constante dielétrica. Uma sonda helicoidal TDR, que pode ser cravada em conjunto outros ensaios de penetração in situ para a estimativa do teor de umidade em diversas profundidades, tem aplicação interessante para a investigação geotécnica do subsolo. No presente trabalho, uma sonda TDR foi adaptada e utilizada em conjunto ao ensaio CPT para caracterização de um perfil de solo arenoso não saturado que ocorre na região de Bauru (SP). A calibração dessa sonda foi feita em laboratório especificamente para esse solo. As equações de calibração que mostraram os melhores resultados foram definidas correlacionando a constante dielétrica, condutividade elétrica aparente e a massa específica seca com o teor de umidade. Com o intuito de melhorar a acurácia na determinação do teor de umidade em campo e eliminar possíveis interferências no registro da onda eletromagnética, foram efetuadas modificações em algumas características do projeto original dessa sonda. Tais modificações consistiram em separar os eletrodos condutores e as partes metálicas da sonda, e eliminar o cabo coaxial de extensão, conectando a sonda diretamente a um cabo coaxial de 12 m de comprimento. Tais mudanças levaram a uma melhoria significativa na determinação do perfil de teor de umidade do local estudado. Os valores de teor de umidade de campo determinados usando o TDR ao longo de 8 m de profundidade foram comparados com os valores de referência obtidos de amostras deformadas retiradas com trado mecânico. O erro médio na estimativa do perfil de teor de umidade gravimétrico utilizando a sonda TDR helicoidal foi de 1.61%, na última campanha de ensaios realizados. Os resultados dessa pesquisa indicam que esta ferramenta é adequada para estimar do perfil de teor de umidade para uso em conjunto com o ensaio CPT. / The time domain reflectometry allows estimating the moisture content of a medium by means of its correlation with the dielectric constant. A coil TDR probe, which can be driven into the ground together with others in situ penetration tests, can be used to estimate the moisture content at different depths. It is an interesting approach for geotechnical site characterization. In this work, a coil TDR probe was adapted and used in combination with the CPT test for the site characterization of an unsaturated sandy soil profile which occurs in the region of Bauru (SP). The probe calibration was performed in laboratory specifically for that soil. The calibration equation, which presented the best results, were defined correlating the dielectric constant, electrical conductivity and dry density with the moisture content. In order to improve the accuracy for determining the water content in the field and to eliminate possible interference on the electromagnetic wave registration, modifications were made in some characteristics of the original design of this probe. Such modifications consisted in separating the conductive electrodes from the metal parts of the probe, and eliminating the coaxial extension cable, connecting the probe directly to a coaxial cable 12 m long. Such changes have led to a significant improvement in the determination of the moisture content profile of the studied site. The moisture content values determined in situ by using the TDR along 8 m depth were compared with reference values obtained from disturbed soil samples collected using mechanical augers. The root mean square error of the gravimetric water content profile using the TDR coil probe was 1.61% in the last test campaign. The results of this research indicate that this tool is suitable to estimate the gravimetric moisture content together with the CPT test.
78

Análise de falhas em transformadores de distribuição por metodologia forense / Analysis of distribution transformers failure by forensic methodology

Ferreira, Daniel Augusto Pagi 26 September 2013 (has links)
A maior parte das concessionárias de energia elétrica brasileiras normalmente não trata as falhas em transformadores de distribuição como um problema relevante sob ponto de vista financeiro, uma vez que qualquer ação preventiva para minimizar o problema dentro da realidade atual pode ser mais onerosa. Portanto, políticas adequadas para investigar as falhas de transformadores de distribuição são geralmente relegadas a segundo plano ou às vezes nem existem. Neste contexto, a informação existente em falhas de transformadores pode não conter dados importantes. No entanto, novas leis que afetam as concessionárias de energia estão mais severas e demandam por maior eficiência por parte delas. Neste novo cenário, uma metodologia forense, criada há muitos anos por várias concessionárias para analisar falhas em transformadores de distribuição, foi recentemente resgatada com a análise de 3159 equipamentos. Essa metodologia é conhecida como Metodologia Forense para Transformadores de Distribuição (MFTD) e será utilizada como ferramenta de diagnóstico para estudos de casos. Novos testes e ensaios como medição de resistência de isolamento, índice de absorção dielétrica e polarização, análise físico-química entre outros, serão agregados à metodologia forense para aprimorá-la. Além disso, os para-raios, sendo parte do sistema de proteção de transformadores de distribuição, também são estudados com o objetivo de verificar possíveis falhas de projeto e desafios a serem superados. / Most Brazilian utility companies normally do not treat failures in distribution transformers as a relevant problem in large financial point of view, since any preventive action to minimize them within the current reality can be more costly. Thus, proper policies for investigating faults in distribution transformers are usually disregarded by the power utilities and sometimes policies may not even exist. In this context, existing information on faulty distribution transformers may not contain important data. However, new laws affecting power distribution companies are becoming more severe and there are demands for greater efficiency. In this new scenario, a forensic methodology to analyse faults in distribution transformers, created some years ago by many utilities, has recently been resurrected with the analysis of 3,159 distribution transformers. This methodology is known as Forensic Analysis Applied to Distribution Transformers (FAADT). New tests and trials as measuring insulation resistance, polarization index and dielectric absorption, physical and chemical analysis among others, will be added to the forensic methodology to improve it. Moreover, the surge-arresters, being part of the system of protection of distribution transformers, are also studied in order to evaluate possible design flaws and challenges to overcome.
79

Análise de falhas em transformadores de distribuição por metodologia forense / Analysis of distribution transformers failure by forensic methodology

Daniel Augusto Pagi Ferreira 26 September 2013 (has links)
A maior parte das concessionárias de energia elétrica brasileiras normalmente não trata as falhas em transformadores de distribuição como um problema relevante sob ponto de vista financeiro, uma vez que qualquer ação preventiva para minimizar o problema dentro da realidade atual pode ser mais onerosa. Portanto, políticas adequadas para investigar as falhas de transformadores de distribuição são geralmente relegadas a segundo plano ou às vezes nem existem. Neste contexto, a informação existente em falhas de transformadores pode não conter dados importantes. No entanto, novas leis que afetam as concessionárias de energia estão mais severas e demandam por maior eficiência por parte delas. Neste novo cenário, uma metodologia forense, criada há muitos anos por várias concessionárias para analisar falhas em transformadores de distribuição, foi recentemente resgatada com a análise de 3159 equipamentos. Essa metodologia é conhecida como Metodologia Forense para Transformadores de Distribuição (MFTD) e será utilizada como ferramenta de diagnóstico para estudos de casos. Novos testes e ensaios como medição de resistência de isolamento, índice de absorção dielétrica e polarização, análise físico-química entre outros, serão agregados à metodologia forense para aprimorá-la. Além disso, os para-raios, sendo parte do sistema de proteção de transformadores de distribuição, também são estudados com o objetivo de verificar possíveis falhas de projeto e desafios a serem superados. / Most Brazilian utility companies normally do not treat failures in distribution transformers as a relevant problem in large financial point of view, since any preventive action to minimize them within the current reality can be more costly. Thus, proper policies for investigating faults in distribution transformers are usually disregarded by the power utilities and sometimes policies may not even exist. In this context, existing information on faulty distribution transformers may not contain important data. However, new laws affecting power distribution companies are becoming more severe and there are demands for greater efficiency. In this new scenario, a forensic methodology to analyse faults in distribution transformers, created some years ago by many utilities, has recently been resurrected with the analysis of 3,159 distribution transformers. This methodology is known as Forensic Analysis Applied to Distribution Transformers (FAADT). New tests and trials as measuring insulation resistance, polarization index and dielectric absorption, physical and chemical analysis among others, will be added to the forensic methodology to improve it. Moreover, the surge-arresters, being part of the system of protection of distribution transformers, are also studied in order to evaluate possible design flaws and challenges to overcome.

Page generated in 0.0506 seconds