• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do parâmetro H/w sobre o auto amortecimento de cabos condutores de energia

Miranda, Thiago Barbosa de 04 August 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-10-17T18:05:22Z No. of bitstreams: 1 2017_ThiagoBarbosadeMiranda.pdf: 3222848 bytes, checksum: b1768afccba836859c987449bd139eb2 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-10-24T16:18:03Z (GMT) No. of bitstreams: 1 2017_ThiagoBarbosadeMiranda.pdf: 3222848 bytes, checksum: b1768afccba836859c987449bd139eb2 (MD5) / Made available in DSpace on 2017-10-24T16:18:03Z (GMT). No. of bitstreams: 1 2017_ThiagoBarbosadeMiranda.pdf: 3222848 bytes, checksum: b1768afccba836859c987449bd139eb2 (MD5) Previous issue date: 2017-10-24 / Nesse trabalho foi realizada uma comparação do auto amortecimento dos cabos condutores Tern, Orchid e CAL 900, tendo como parâmetro de avaliação a relação H/w. Para tal, foram geradas curvas de auto amortecimento, a partir do Método da Potência, para os três cabos em níveis de H/w de 1820 m, 2144 m e 2725 m, considerando três diferentes frequências de excitação e cinco amplitudes de deslocamento. Foi avaliado a influência da frequência e amplitude de vibração no auto amortecimento de cada cabo condutor, sendo observado um crescimento exponencial da potência dissipada com a variação desses parâmetros. Foi feita uma comparação entre as curvas de potência dissipada dos diferentes cabos, quando submetidos as mesmas condições de vibração e nível de H/w, o cabo condutor Tern obteve o maior auto amortecimento, o CAL 900 obteve valores intermediários e o Orchid teve os menores valores de potência em todos os ensaios. Finalmente, foi realizada uma correlação entre o auto amortecimento e vida em fadiga dos cabos condutores na linha de transmissão quando submetidos as mesmas condições dos ensaios experimentais, nesse estudo o cabo Orchid apresentou o melhor resultado para o caso analisado e o cabo CAL 900 teve um resultado inferior aos demais, apresentando uma estimativa de vida menor que os demais. / In this work, a comparison of the self-damping of the overhead conductors Tern, Orchid and CAL 900 was carried out, using the H/w ratio as an evaluation parameter. Therefore, the self-damping curves were generated using the Power Method for the three cables at H/w levels of 1820 m, 2144 m and 2725 m, and considering three different excitation frequencies at five different displacement amplitudes for each H/w level. The influence of the frequency and amplitude of vibration on the self-damping of each conductor was evaluated. One could observe an exponential growth of the power dissipated with the variation of these parameters. Additionally, a comparison between the power-dissipated curves of the different cables was made considering the same conditions of vibration and H/w level. The Tern conductor cable has a higher self-damping value meanwhile the CAL 900 presents an intermediate value and the Orchid has a lower values for all tests. Finally, a correlation between the self-damping and fatigue life of the cables in the transmission line when subject to the same conditions of the experimental tests were submitted. In this study Orchid cable presented a good result for the analyzed case and the cable CAL 900 has a bad result to the others, presenting a smaller life estimate than the others.
2

Análise numérica e experimental na determinação da potência térmica dissipada em componentes eletrônicos

Sousa, Reginaldo Ribeiro de [UNESP] 28 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-28Bitstream added on 2014-06-13T19:55:37Z : No. of bitstreams: 1 sousa_rr_me_ilha.pdf: 2111422 bytes, checksum: 55ec661a37c8225f8f3075712c8ec225 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Os objetivos deste trabalho são determinar a potência térmica dissipada dos componentes eletrônicos de forma experimental e verificar a eficácia do método através de simulações numéricas computacionais utilizando o software comercial ANSYS. O Software ANSYS foi usado como ferramenta de Dinâmica de Fluidos Computacional neste trabalho. Para a realização deste trabalho um ensaio experimental foi executado a fim de obter alguns dados para o cálculo da potência térmica dissipada, outros foram fornecidos pelo CPqD e Trópico. Foi montado um Laboratório Computacional com o apoio da Trópico e do CPqD na UNESP, campus de Ilha Solteira para a simulações numéricas. O método de cálculo de potência apresentou-se eficaz, de modo na melhor situação os resultados apresentaram um erro relativo médio de 1,94%. / The purpose of this study is to determine the thermal power dissipation of electronic components through an experimental test and verify the effectiveness of the method through numerical simulations using the computational software ANSYS commercial. Software ANSYS was used as a tool for Computational Fluid Dynamics for this work. For this work an experimental test was done to obtain some data to calculate the thermal power dissipation, others were supplied by CPqD, Nilko and Trópico. It was dubbed a Computer Laboratory with the support of the Trópico, CPqD and at UNESP, campus de Ilha Solteira for the numerical simulations. The method of calculation of power proved to be effective, that the better the results showed a mean relative error is 1.94%.

Page generated in 0.0456 seconds