• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simulação computacional de um tomógrafo capacitivo elétrico paralelo aplicado ao processo adsortivo / Computer simulation of an parallel electrical capacitive tomography applied to adsorptive process

Cavalcanti, Vladyr Yuri Soares de Lima 30 April 2009 (has links)
Made available in DSpace on 2015-05-08T15:00:00Z (GMT). No. of bitstreams: 1 parte1.pdf: 2338507 bytes, checksum: 6275f329bc4f4dc275a86cd47c9ba994 (MD5) Previous issue date: 2009-04-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This thesis aims to computationally simulate the electronic transducer for a parallel electrical capacitance tomography, can generate a voltage level used for image reconstruction of the adsorption phenomenon occurred in the adsorptive bed. This simulation was performed using a computer program like SPICE (Simulation Program with Integrated Circuit Emphasis) for the purpose of defining the parameters for its construction, dedicated to the application of the adsorptive bed bench in a glass case studies of the adsorptive process. This technique uses capacitive sensors coupled to an electronic transducer that will generate a voltage signal associated with the distribution of dielectric permittivity of the medium. The simulation is developed to simulate the main circuit, a differentiator, fitted with high frequency OPA 2690. The simulated model is a simple circuit with a transmitter and a receiver. The results show the technical feasibility of the project being proposed for future work to implement a prototype of the electronic transducer of electrical capacitance tomography applied to the study of the adsorption process. / Esta dissertação tem como objetivo simular computacionalmente o transdutor eletrônico para um tomógrafo capacitivo elétrico paralelo capaz de gerar um nível de tensão utilizado para a reconstrução da imagem do fenômeno de adsorção ocorrido no leito adsortivo. Esta simulação foi realizada em um programa computacional do tipo SPICE (Programa de Simulação com Ênfase em Circuito Integrado) com a finalidade de definir os parâmetros para a sua construção, voltado para a aplicação no leito adsortivo de uma bancada em vidro para estudos do processo adsortivo. Esta técnica utiliza sensores capacitivos acoplados a um transdutor eletrônico que vão gerar um sinal de tensão associado à distribuição da permissividade dielétrica do meio. A simulação desenvolvida consiste em simular o circuito principal, um diferenciador, montado com OPA 2690 de alta freqüência. Simulou-se de um modelo de circuito simples, com um transmissor e um receptor. Os resultados apresentados mostram a viabilidade técnica do projeto, sendo proposto para trabalhos futuros a implementação de um protótipo do transdutor eletrônico do tomógrafo capacitivo elétrico aplicado ao estudo do processo de adsorção.
2

Estudo de um tomógrafo capacitivo elétrico paralelo aplicado ao processo adsortivo / Study of a parallel electrical capacitance tomographer applied to adsorption process

Soares., Manoel Brasileiro 30 April 2009 (has links)
Made available in DSpace on 2015-05-08T15:00:04Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2331376 bytes, checksum: b24878b19226d38bdcde15cfe285f7cb (MD5) Previous issue date: 2009-04-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Adsorption refrigeration systems are supposed to complement or even substitute the ordinary systems based on vapour compression. This work aims to study the application of a new technique of Electrical Capacitive Tomography - a parallel approach on the visualization of the adsorption process which occurs in the sorption bed of an adsorption refrigerator. To archive this goal, a sorption bed glass prototype was developed and it allows the utilization of the Parallel ECT to map the spatial distribution of methanol into the activated charcoal inside the sorption bed and makes it feasible to optimise the process. The principles of the adsorption phenomenon are explained regarding the adsorption refrigeration cycle. The Parallel ECT system is based on a wideband electronic differentiator which is supposed to be immune to stray capacitances often encountered in ordinary ECT systems, to have a high sensitivity, good signal-to-noise ratio, accuracy, and to be faster then the serial tomography. The various components of a tomographic system are analyzed as well as the results obtained from PSPICE electronic simulations and the making process of the printed circuit boards for the modules of an ECT system is also shown. / Sistemas de refrigeração por adsorção se constituem numa das alternativas para a complementação, ou mesmo, substituição de sistemas convencionais por compressão de vapor. Este trabalho visa estudar a aplicação de uma nova técnica de Tomografia Capacitiva Elétrica (TCE) na visualização do processo adsortivo que ocorre no leito adsorvedor durante um ciclo de operação de um de refrigerador por adsorção. Para esta finalidade, foi desenvolvido um protótipo do leito adsorvedor em vidro que permite a utilização da TCE Paralela para mapear a distribuição espacial do metanol no carvão ativado no adsorvedor e possibilita sua otimização. Os princípios do fenômeno de adsorção são também abordados, no que se refere ao ciclo de refrigeração por adsorção. É descrito um novo tipo de TCE através do processamento paralelo de sinal e utilizando um circuito transdutor constituído de um diferenciador de alta taxa de subida e grande largura de banda. A este sistema é creditada a imunidade a capacitâncias parasitas, comum aos sistemas usuais de TCE, além de alta sensibilidade, boa relação sinal-ruído, exatidão e por ser mais rápido que a tomografia serial. Os diversos componentes deste sistema tomográfico são analisados, bem como os resultados obtidos através de simulação eletrônica do tipo PSPICE e também o processo de confecção das placas de circuito impresso para os módulos de um sistema TCE

Page generated in 0.0853 seconds