• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5783
  • 109
  • 97
  • 84
  • 84
  • 83
  • 55
  • 37
  • 29
  • 21
  • 21
  • 18
  • 3
  • 3
  • 1
  • Tagged with
  • 6029
  • 3373
  • 2538
  • 1559
  • 1414
  • 1184
  • 959
  • 777
  • 749
  • 729
  • 672
  • 662
  • 615
  • 611
  • 525
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
841

Conversor CC-CC bidirecional DAB monofásico baseado na célula de comutação de três estados / Single phase bidirectional DAB DC-DC converter based on three state switching cell

Mazza, Luan Carlos dos Santos 15 December 2014 (has links)
MAZZA, L. C. S. Conversor CC-CC bidirecional DAB monofásico baseado na célula de comutação de três estados. 2014. 213 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-06-09T17:51:35Z No. of bitstreams: 1 2014_dis_lcsmazza.pdf: 7314394 bytes, checksum: 9224557c46db00f9fbbcede414d715c4 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-06-10T17:44:38Z (GMT) No. of bitstreams: 1 2014_dis_lcsmazza.pdf: 7314394 bytes, checksum: 9224557c46db00f9fbbcede414d715c4 (MD5) / Made available in DSpace on 2015-06-10T17:44:38Z (GMT). No. of bitstreams: 1 2014_dis_lcsmazza.pdf: 7314394 bytes, checksum: 9224557c46db00f9fbbcede414d715c4 (MD5) Previous issue date: 2014-12-15 / This work presented is DC-DC isolated ZVS Bidirectional Dual Active Bridge (DAB) single phase converter, based three-state switching cell is presented. The proposal is to apply it in photovoltaic systems with battery bank into smart networks. Basically the drive control is the duty cycle (D) of the switches and the Phase Shift (φ) of the fundamental tensions between the bridges. The gyrator modeling of the converter is presented, highlighting its natural operating characteristic as gyrator. Shows the qualitative and quantitative analysis of the converter, realizing the full study of the stages of operation of the topology and checking all sixteen regions of operation. To obtain the regions of soft-switching, the fundamental model is applied. The design procedure of the converter is presented, and the results of simulations. A 2kW prototype was developed, aimed at obtaining experimental results validate the theoretical analysis / Neste trabalho é apresentado o conversor CC-CC ZVS isolado bidirecional Dual Active Bridge (DAB) monofásico, baseado na célula de comutação de três estados. A proposta é aplicá-lo em sistemas fotovoltaicos com banco de baterias em redes inteligentes. Basicamente o controle do conversor consiste na razão cíclica (D) dos interruptores e o Phase Shift (φ) entre as componentes fundamentais das tensões entre as pontes. A modelagem por gyrator do conversor é apresentada, destacando-se sua característica natural de funcionamento como gyrator. Mostra-se a análise qualitativa e quantitativa do conversor, realizando o estudo completo das etapas de operação da topologia e verificando todas as dezesseis regiões de operação. Para obtenção das regiões de comutação suave, é aplicado o modelo fundamental. O procedimento de projeto do conversor é apresentado, além dos resultados de simulações. Um protótipo de 2 kW foi desenvolvido, visando a obtenção dos resultados experimentais e validando a análise teórica
842

Microinversor monofásico baseado na derivação da topologia flyback para sistema de geração fotovoltaica / Microinversor single phase based on the drifting of flyback topology for generating system photovoltaic

Freire, Fábio José Lima 30 April 2015 (has links)
FREIRE, F. J. L. Microinversor monofásico baseado na derivação da topologia flyback para sistema de geração fotovoltaica. 2015. 132 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-06-17T12:36:34Z No. of bitstreams: 1 2015_dis_fjlfreire.pdf: 3547231 bytes, checksum: edcc290f551a4b302ada79ab7833da29 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-06-17T14:23:49Z (GMT) No. of bitstreams: 1 2015_dis_fjlfreire.pdf: 3547231 bytes, checksum: edcc290f551a4b302ada79ab7833da29 (MD5) / Made available in DSpace on 2015-06-17T14:23:49Z (GMT). No. of bitstreams: 1 2015_dis_fjlfreire.pdf: 3547231 bytes, checksum: edcc290f551a4b302ada79ab7833da29 (MD5) Previous issue date: 2015-04-30 / The study proposes the design and implementation of a single phase inverter of single stage obtained the derivation of four flybacks converters CC - CC operating in discontinuous mode and associated in parallel modules. This arrangement reduces the amount of magnetic and decreases current efforts in primary transformers and minimizes fluctuations i n photovoltaic module. Among the main properties of micro inverter flyback (MIF) this research, the primary keys work with SPWM switching at high frequency and lagged in one hundred and eighty degrees, while the secondary keys are controlled by PWM's compl ementary. To validate the research, we will develop a prototype that will effect the processing power connecting a photovoltaic panel with 200W power in resistive loads with senoidais characteristics. The proposed system is based on the configuration of th e integrated module drive (MIC), which, in turn, has lower losses in the semi - conductors and magnetic elements of the topology, when compared to complex centralized photovoltaic systems. Among the applications of micro inverter flyback are: supply of remote systems, power electronics devices, small water pumping stations, connections to the grid, among others. Despite the low power, micro inverter has electrical characteristics essential for the insertion in the energy matrix, such as: insulation betwe en the source and the load, types of voltages and currents waves in output with little distortion and frequency of the network. The results obtained in the laboratory show that the micro inverter flyback operating in open loop gets yields close to 90% bein g delivered to the load about 180W. Thus, the ease of construction, the use of fewer components and results collected experimentally enable the micro inverter flyback to perform the CC - CA conversion of photovoltaic systems of small powers connected in sing le - phase linear loads with senoidais characteristics or interconnected to the electric grid / A pesquisa desenvolve o projeto e a implementação de um microinversor monofásico de estágio único obtido da derivação de quatro conversores flybacks CC-CC operando no modo descontínuo e associado em módulos paralelos. Este arranjo reduz o volume dos magnéticos, diminui os esforços de correntes nos primários dos transformadores, bem como minimiza as oscilações no módulo fotovoltaico. Em meio as principais propriedades do microinversor flyback (MIF) desta pesquisa, as chaves dos primários atuam com comutação SPWM em alta frequência e defasadas em cento e oitenta graus, enquanto as chaves dos secundários são comandadas por PWM’s complementares. Para validar a pesquisa será desenvolvido um protótipo que efetuará o processamento de energia interligando um painel fotovoltaico com 200 W de potência, em cargas resistivas com características senoidais. O sistema proposto está fundamentado na configuração módulo inversor integrado (MIC), que por sua vez, possui menores perdas nos semicondutores e elementos magnéticos da topologia, quando comparado aos complexos sistemas fotovoltaicos centralizados. Dentre as aplicações do microinversor flyback encontram-se: abastecimento de sistemas remotos, alimentação de aparelhos eletroeletrônicos, pequenas estações de bombeamentos de água, conexões a rede elétrica, entre outros. Apesar da baixa potência, o microinversor apresenta características elétricas essenciais a inserção na matriz energética, tais como: isolação entre a fonte e a carga, formas de ondas de tensões e correntes na saída com pequenas distorções e na frequência da rede. Os resultados obtidos em laboratório revelam que o microinversor flyback operando em malha aberta obtém rendimentos próximos a 90%, sendo entregue à carga cerca de 180 W. Sendo assim, a facilidade na construção, a utilização de poucos componentes e os resultados coletados experimentalmente habilitam o microinversor flyback a realizar a conversão CC-CA de sistemas fotovoltaicos de pequenas potências conectados em cargas lineares monofásicas com características senoidais ou interligados à rede elétrica
843

Desempenho técnico-financeiro de sistema híbrido eólico-solar aplicado ao bombeamento de água / Technical and financial performance of wind-solar hybrid system applied to water pumping

Arruda, Marcelo Ferreira de 05 August 2015 (has links)
ARRUDA, M. F. Desempenho técnico-financeiro de sistema híbrido eólico-solar aplicado ao bombeamento de água. 2015. 134 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-08-21T18:10:57Z No. of bitstreams: 1 2015_dis_mfarruda.pdf: 9045547 bytes, checksum: 247514da0899dae08d1f74dd28d181cf (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-08-26T17:33:53Z (GMT) No. of bitstreams: 1 2015_dis_mfarruda.pdf: 9045547 bytes, checksum: 247514da0899dae08d1f74dd28d181cf (MD5) / Made available in DSpace on 2015-08-26T17:33:53Z (GMT). No. of bitstreams: 1 2015_dis_mfarruda.pdf: 9045547 bytes, checksum: 247514da0899dae08d1f74dd28d181cf (MD5) Previous issue date: 2015-08-05 / This work has as main objective the installation and technical - financial evaluation of a hybrid wind - photovoltaic system applied to water pumping . In addition, a sizing methodology is proposed based on renewable sources considering low cost and available potential. The hybrid system was installed in front of the Pici Campus reservoir of the Federal Univers ity of Ceará (UFC) in Fortaleza /CE, Brazil. The hybrid system consists of 01 wind turbine of 1 kW, 04 photovoltaic modules of 87 Wp, a battery bank with 05 units of 150 Ah. The pumping system con sists of a motor - pump 0, 5 cv . Technical analysis was performed by analyzing the data (electric and non - electric) collected by sensors to a supervisory system. The results indicate that the wind resource variation for the site is higher, when compared to the solar resource, and the availability of the potential of both resources are concomitant during the daytime period, a characteristic also observed in the anal yzed period. T he generation system with battery bank, operating in either the hybrid configuration or individual, assured the supply of electricity to the pumping system during operating time . From the indicators of efficiency, it was found that the conver sion units showed divergence between estimated and measured electricity generation, and wind unit which presented greater divergence. The electricity cost of the hybrid system (wind - solar) installed with battery bank is 0.86 R$/kWh. The sizing of the generating system indicated that the hybrid configuration at the site does not fit due to the high solar potential available and the low availability of wind resources in the 1 st trimester of the year . The sizing generation system indicated that th e hybrid configuration has the lowest cost (1.52 R$/kWh) when sizing with the resources of October month . Indicating thus , that when more than one renewable source stands out , the hybrid configuration can be viable alternative / A presente dissertação apresenta como objetivo principal a instalação e avaliação de desempenho técnico-financeiro de um sistema híbrido eólico-fotovoltaico aplicado ao bombeamento de água. Adicionalmente, é proposta uma metodologia de dimensionamento de sistema híbrido de geração baseado em fontes renováveis em função do menor custo e do potencial disponível. O sistema de geração híbrido foi instalado na jusante do açude do Campus do Pici da Universidade Federal do Ceará (UFC), em Fortaleza/CE, Brasil. O sistema híbrido é composta por 01 aerogerador de 1 kW, 04 módulos fotovoltaicos de 87 Wp, sistema de banco de baterias com 05 unidades de 150 Ah. O sistema de bombeamento é composto por um conjunto moto-bomba de 0,5 cv. A análise técnica foi efetuada mediante análise dos dados (elétricos e não elétricos) coletados através de sensores instalados a um sistema supervisório. Os resultados indicam que a variação do recurso eólico para o local é mais elevada, quando comparado ao recurso solar, e que a disponibilidade do potencial de ambos os recursos são praticamente concomitantes ao longo do período diurno, característica esta também observada no período analisado. O sistema de geração com banco de baterias, operando tanto na configuração híbrida ou individual, assegurou o fornecimento de eletricidade para o sistema de bombeamento no período de funcionamento da carga. A partir dos indicadores de eficiência, verificou-se que as unidades de conversão apresentaram divergência entre a geração de eletricidade estimada e a mensurada, tendo a unidade eólica a qual apresentou maior divergência. O custo da energia elétrica do sistema híbrido instalado (eólico-solar) com banco de baterias é de 0,86 R$/kWh. O dimensionamento do sistema de geração indicou que a configuração híbrida para o local não se ajusta em virtude do elevado potencial solar disponível e da baixa disponibilidade do recurso eólico no 1º trimestre do ano. O dimensionamento indicou que a configuração híbrida foi a de menor custo (1,52 R$/kWh) quando dimensionada em função dos recursos do mês de Outubro. Indicando assim que quando mais de uma fonte renovável se destaca a configuração híbrida pode ser sim uma alternativa viável
844

Uma Nova perspectiva de eletrificação rural em corrente contínua: uma experiência no Estado do Piauí / A New perspective in rural electrification in DC voltage: an experience in the State of Piauí

Soares, Emanoel Augusto Paulo 21 November 2011 (has links)
SOARES, E. A. P. Uma Nova perspectiva de eletrificação rural em corrente contínua: uma experiência no Estado do Piauí. 2011. 81 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-09-02T18:18:47Z No. of bitstreams: 1 2011_dis_eapsoares.pdf: 2379493 bytes, checksum: a0360e962d008eb23a020e4aab9195a2 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-09-28T18:06:03Z (GMT) No. of bitstreams: 1 2011_dis_eapsoares.pdf: 2379493 bytes, checksum: a0360e962d008eb23a020e4aab9195a2 (MD5) / Made available in DSpace on 2015-09-28T18:06:03Z (GMT). No. of bitstreams: 1 2011_dis_eapsoares.pdf: 2379493 bytes, checksum: a0360e962d008eb23a020e4aab9195a2 (MD5) Previous issue date: 2011-11-21 / This work presents the studies, specifications, installation and operation of a photovoltaic system in order to provide electricity to a public school located in an isolated area of the southern state of Piauí. The system was proposed and its prototype constituted by photovoltaic panel, battery bank, charger from the battery bank and converter DC / DC elevator, that feed the chargers in direct current designed for a range of three days, even in minimum solar radiation. The solar energy captured by solar panel is stored in a stationary batteries, lead acid type. The battery charger working at maximum power point (MPP) of the panel is responsible for load bank. The load is supplied by the DC / DC converter lift high gain (24 Vdc to 311 Vdc). The complete design system and its control are presented throughout this work, as well as presented the main results of the experimental prototype shown and installed in the field / O presente trabalho apresenta os estudos, especificações, instalação e operação de um sistema fotovoltaico com a finalidade de fornecer energia elétrica a uma escola pública, localizada em uma área isolada do sul do Estado do Piauí. O sistema foi proposto e seu protótipo constituído por painel fotovoltaico, banco de baterias, carregador do banco de bateria e conversor CC/CC elevador, que alimenta as cargas em corrente contínua, projetado para uma autonomia de três dias, mesmo em condições mínimas de radiação solar. A energia solar capturada pelo painel solar é armazenada em um banco de baterias estacionárias do tipo chumbo-ácido. O carregador de baterias trabalhando no ponto de máxima potência (MPP) do painel é responsável pelo carregamento deste banco. A carga é suprida pelo conversor CC/CC elevador de alto ganho (24 Vdc para 311 Vdc). O projeto completo do sistema é apresentado ao longo deste trabalho, bem como são apresentados os principais resultados experimentais do protótipo mostrado e instalado em campo
845

Confiabilidade das determinações de localizadores eletrônicos foraminais : estudos ex vivo e in vivo / Reliability of electronic foramen locators determinations: an ex vivo and in vivo studies

Vasconcelos, Bruno Carvalho de January 2011 (has links)
VASCONCELOS, Bruno Carvalho de. Confiabilidade das determinações de localizadores eletrônicos foraminais : estudo ex vivo e in vivo. 2011. 75 f. Tese (Doutorado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T14:00:58Z No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T16:16:39Z (GMT) No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) / Made available in DSpace on 2012-02-02T16:16:39Z (GMT). No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) Previous issue date: 2011 / The electronic foramen locators (EFLs) currently available are based on different methods for determination of the distance between the apical foramen and a coronal reference, consequently presenting the real root canal length. Each of these methods aim to offer greater precision while presenting lower sensitivity to potential interferences found in the root canal system. With this in mind, the goal of this work was to evaluate the precision of some of these EFLs ex vivo and in vivo for electronic measurement of the root canal length at two different positions (0.0 mm and -1.0 mm) and under clinical conditions, respectively. In the ex vivo study, 42 mandibular bicuspids had their actual lengths compared to electronic measurements performed by the following EFLs: Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15. Initial measurements were performed to positions identified by the devices as 1.0 mm short of the apical foramen (AF), and subsequent measurements were at the AF (0.0 mm). For the in vivo study, ten patients with bicuspids referred for extraction as part of their orthodontic clinical planning had electronic root length measurements using two EFLs, Propex II and Root ZX, prior to extraction. The last files used were fixated to the teeth, which were then extracted. Then, the apical 4 mm of the canals were exposed to allow assessment of the distance between the tip of the file and the AF. The percentages of precision from the ex vivo electronic measurements at 0.0 mm and -1.0 mm considering each device were: 70.6% and 47.1% (Root ZX); 61.8% and 52.9% (Mini Apex Locator); 67.6% and 38.2% (Propex II); 61.8% and 38.2% (iPex); and 73.5% and 38.2% (RomiApex A-15), respectively (±0.5 mm). Statistical differences were observed for Propex II, iPex, and RomiApex A-15 when measurements at both positions were compared (0.0 mm X -1.0 mm). No significant differences between the EFLs were observed at 0. 0 mm. However, at -1.0 mm, the precision of iPex was statistically lower compared with the other devices. Regarding the in vivo study, the AF was located in 75% (Root ZX) and 66.7% of the teeth (Propex II), under a tolerance margin of ±0.5 mm. Statistically significant differences were observed between the two EFLs. Based on the results obtained and considering the conditions of this work, it was concluded that EFLs are reliable tools for determining the real length of the canal, but are not infallible. It was also observed in the ex vivo experiments that all EFLs had decreased precision in measurements with the instruments short of the AF, with significant differences observed between Propex II, iPex, and RomiApex A-15. Moreover, it was concluded that under clinical conditions, Root ZX was more reliable than Propex II. / Os localizadores eletrônicos foraminais (LEFs) disponíveis atualmente utilizam diversos métodos de determinação eletrônica da posição foraminal, qual seja a medida entre o forame apical e uma referência incisal/oclusal, definindo consequentemente o comprimento do canal radicular. Cada um desses métodos procura oferecer maior precisão e menor sensibilidade a possíveis interferências no sistema de canais radiculares. Desta forma, procurou-se avaliar a precisão de alguns destes LEFs ex vivo e in vivo na realização de odontometrias eletrônicas em diferentes posições (0,0 mm e -1,0 mm) e em condições de uso clínico, respectivamente. No estudo ex vivo, 42 pré-molares inferiores tiveram seus comprimentos reais comparados a odontometrias eletrônicas realizadas com os LEFs Root ZX, Mini Apex Locator, Propex II, iPex e RomiApex A-15. Inicialmente, em função dos displays dos aparelhos, determinaram-se medições 1,0 mm aquém do forame apical (FA), e posteriormente as medições no FA. Para o estudo in vivo, dez pacientes que apresentavam pré-molares com indicação de exodontia como parte de seus planejamentos clínicos ortodônticos tiveram odontometrias eletrônicas realizadas com os LEFs Propex II e Root ZX previamente a exodontia. Os últimos instrumentos utilizados foram fixados aos dentes que foram então extraídos e tiveram 4,0 mm apicais de suas raízes expostos e analisados quanto à distância entre as pontas dos instrumentos e os FA. No estudo ex vivo, considerando as medições realizadas por cada um dos aparelhos a 0,0 mm e a -1,0 mm, a precisão dos LEFs foi: 70,6% e 47,1% (Root ZX), 61,8% e 52,9% (Mini Apex Locator), e 67,6% e 38,2% (Propex II), 61,8% e 38,2% (iPex), e 73,5% e 38,2% (RomiApex A-15), respectivamente (±0,5 mm). Diferenças estatísticas foram encontradas para o Propex II, iPex e RomiApex A-15, quando comparadas suas leituras nas duas posições (0,0mm X -1,0 mm). Não foram encontradas diferenças entre os LEFs a 0,0 mm, porém, a -1,0 mm o iPex foi estatisticamente inferior aos demais. Já no estudo in vivo, o FA foi localizado em 75% (Root ZX) e 66,7% (Propex II), considerando margem de ±0,5 mm, tendo sido encontrada diferença estatisticamente significante entre os LEFs. Diante do exposto, nas condições do estudo, pode-se concluir que os LEFs são ferramentas confiáveis na determinação de comprimentos reais, todavia, não são infalíveis; que em condições ex vivo, quando mantidos aquém do FA, todos os LEFs reduziram sua precisão, tendo o Propex II, iPex e RomiApex A-15 apresentado diferenças significantes; e que em condições de uso clínico, o Root ZX apresentou maior confiabilidade do que o Propex II.
846

Sistema para seleção automática de grupos de ajustes em relés de proteção / System for automatic selection of groups of settings in protective relays

Silveira, José Giordane 11 1900 (has links)
SILVEIRA, J. G. Sistema para seleção automática de grupos de ajustes em relés de proteção. 2011. 98 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-01-16T17:43:25Z No. of bitstreams: 1 2011_dis_jgsilveira.pdf: 3681383 bytes, checksum: fef266008a88b934c39f8845a1091bfa (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-01-16T17:43:53Z (GMT) No. of bitstreams: 1 2011_dis_jgsilveira.pdf: 3681383 bytes, checksum: fef266008a88b934c39f8845a1091bfa (MD5) / Made available in DSpace on 2012-01-16T17:43:53Z (GMT). No. of bitstreams: 1 2011_dis_jgsilveira.pdf: 3681383 bytes, checksum: fef266008a88b934c39f8845a1091bfa (MD5) Previous issue date: 2011-11 / The modern systems of measurement, protection, command, control and supervision (MPCCS) have contributed in a meaningful way to increase the security and reliability of the power systems. The most important part of this multifunctional system is the protection system, which has as the main goal to maintain the power system integrity when it is under a disturbance, assuring the people‟s safety as well as the continuation of the services to the part of the system not involved in the disturbance. For this, the protection system must fulfill some basic requirements such as: proper selectivity and coordination, prompt response, sensitivity to protect the largest zone as possible and reliability. In a system protection, one component takes on a prominent position, given its functional importance: the digital protection relay. It is in this device where the necessary adjustments are configured for proper operation of the protection scheme of a given electrical power system. The digital relays are devices that have several protection functions, with multiple levels of settings, measurements, oscillography, supervision, control and communication. Besides all these features, the digital relays have multiple groups of settings that can be previously configured and switched among them, according to operational needs. The changing of setting group in a relay is a very important resource at a protection system, extensively used by protection sectors of companies in the power sector, allowing the optimization of the protection system setting, making it compatible to a new topology taken on by the system after a fault or an intentional removal of some system component. Nowadays this procedure is performed manually, making it vulnerable to human errors that might occur as a consequence of an outage, with serious effect in the system performance indices. In this sense this work presents a system, based on Colored Petri Nets, able to automatically change the setting groups of a protection system when the power network topology changes. This system monitors in real time the status of the circuit breakers in order to take the decision whether a meaningful change in the network topology has taken place. If so, a command is automatically sent to the relays to change the active group setting so as to maintain a suitable coordination of the protection system. / Os modernos sistemas de medição, proteção, comando, controle e supervisão (MPCCS) têm contribuído de forma significativa para o aumento da segurança, confiabilidade e continuidade de serviço dos sistemas elétricos de potência. O sistema de proteção é parte relevante desse sistema multifuncional, o qual tem como objetivo principal manter a integridade do sistema elétrico quando submetido a um distúrbio, garantindo a segurança de pessoas e assegurando a continuidade de serviço da porção não envolvida no problema. Para tanto, o sistema de proteção deve atender a alguns requisitos básicos tais como: boa seletividade e coordenação, rapidez na atuação, sensibilidade para proteger a maior zona de proteção possível e confiabilidade. No sistema de proteção, um componente assume uma posição de destaque: o relé de proteção digital. É neste componente que são configurados os ajustes necessários para o correto funcionamento do esquema de proteção de um dado sistema elétrico. Os relés de proteção digitais são equipamentos multifuncionais, que possuem diversas funções de proteção, medição de grandezas elétricas, registros oscilográficos, supervisão, controle e comunicação. Além de todos estes recursos, os relés digitais dispõem de múltiplos grupos de ajustes que podem ser previamente configurados conforme necessidade operacional. A mudança de grupo de ajuste de um relé é um recurso amplamente utilizado pelas áreas de proteção das empresas do setor elétrico, possibilitando uma otimização do ajuste do sistema de proteção, compatibilizando-o às diversas topologias assumidas pelo sistema elétrico após uma falta ou retirada intencional de algum componente da rede. Atualmente este procedimento é realizado de forma manual, tornando-o vulnerável à falha humana, podendo ter como consequência desligamentos de grandes blocos de carga por falha de coordenação, com graves prejuízos para os indicadores da qualidade de serviço de duração e frequência de interrupção, DEC e FEC, e para a imagem da empresa. Neste trabalho é apresentado um sistema, baseado em Redes de Petri Coloridas, capaz de realizar a mudança automática entre grupos de ajustes de um sistema de proteção a partir da mudança de topologia do sistema elétrico. O sistema desenvolvido monitora a topologia da rede elétrica, em tempo real, a partir das informações de estado dos disjuntores. Para qualquer alteração na configuração da rede elétrica, que caracterize necessidade de alteração no sistema de proteção, automaticamente são enviados sinais de comando para os relés, alterando os grupos de ajustes ativos de um conjunto predefinido, de modo a se obter a melhor graduação de proteção possível para a porção correspondente do sistema elétrico afetado pela alteração de topologia.
847

Controle PID e preditivo: aspectos teóricos e de implantação prática

Adão, Aurélio Agostinho 09 1900 (has links)
ADÃO, A. A. Controle PID e preditivo: aspectos teóricos e de implantação prática. 2011. 85 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-03-12T14:53:30Z No. of bitstreams: 1 2011_dis_aaadao.pdf: 2439084 bytes, checksum: 395d539f6ea85cc18be20a49e4ab8654 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-03-12T14:54:58Z (GMT) No. of bitstreams: 1 2011_dis_aaadao.pdf: 2439084 bytes, checksum: 395d539f6ea85cc18be20a49e4ab8654 (MD5) / Made available in DSpace on 2012-03-12T14:54:58Z (GMT). No. of bitstreams: 1 2011_dis_aaadao.pdf: 2439084 bytes, checksum: 395d539f6ea85cc18be20a49e4ab8654 (MD5) Previous issue date: 2011-09 / Nowadays, we observe the exponential increasing of demand for performance optimization in all areas of modern life. This search for better performances is also occurring in all industry sectors, either factory or energy activities. This best performances reflects an increase is all levels and achieve enormously the process control systems. With more strict performance requirement, technique formerly studied only in academic circle has been migrate for industry area, opening new horizons and establishing new concepts in general. It is not different with the process control systems, even in particular at the lowest level of implementation (factory’s floor) has been noted a constantly update. This paper is inserted into this last concept, in other words, into the project of loop control process at lowest level of the plant. Thus the aspect of tuning of conventional multivariable like PID (Proportional, Integral, Derivative) controllers (MIMO) and MIMO predictive controllers based on models like GPC (Generalized Predictive Control) type are studied aiming to the practical implementation. Several system control aspects, such as identification of process through parametric and nonparametric technical with different representations and aspects of decoupling between the process loop, as it is MIMO system, are also dealt, discussed and implemented. For that purpose, two plants were developed at IFPI’s NEE (Núcleo de Engenharia Elétrica) laboratory. The first platform consists of MIMO system of ventilation and heating; the second platform is a system of coupled double tanks. As a conclusion of the study of practical experiments conducted, can be established that the best control for a process depends on the application for which it is destined and for the proper functioning is necessary the theoretical and practical knowledge of the dynamic of the process. Thus an appropriated controller depends also on the use of a good identification technique. / Atualmente se observa o incremento exponencial das exigências pela otimização de desempenho em todos os setores da vida moderna. Esta busca por melhor desempenho também tem ocorrido em todos os setores da indústria, seja ela de atividade fabril ou de energia. Melhor desempenho no setor industrial se reflete em melhorias em todos os níveis e isto alcança de sobremaneira os sistemas de controle de processos. Com requisitos de desempenho mais rígido, técnicas antigamente estudadas somente em meio acadêmico tem migrado para a indústria abrindo novos horizontes e estabelecendo novos conceitos de uma forma geral. Com os sistemas de controle de processos não é diferente e em particular em seu mais baixo nível de implementação (chão de fábrica) tem se observado uma atualização constante. Esta dissertação está inserida neste último contexto ou seja no projeto das malhas de controle de um sistema de controle de processos. Desta forma aspectos de sintonia de controladores convencionais do tipo PID (Proporcional, Integral, Derivativo) multivariáveis (MIMO) e controladores MIMO preditivo baseado em modelos do tipo GPC (Generalized Predictive Control) são estudados visando a implementação prática. Vários aspectos do sistema de controle tais como a identificação do processo através de técnicas paramétricas e não paramétricas com diferentes representações e aspectos do desacoplamento entre as malhas do processo, por se tratar de sistemas MIMO, são também abordadas, discutidas e implementadas. Para este propósito duas plataformas de desenvolvimento foram desenvolvidas no laboratório do Núcleo de Engenharia Elétrica NEEL do IFPI. A primeira plataforma consiste em sistema MIMO de ventilação e aquecimento, a segunda plataforma um sistema de tanques duplo acoplados. Como conclusão do estudo dos experimentos práticos realizados pode-se estabelecer que o melhor controle para um processo depende da aplicação ao qual este é destinado e para o bom funcionamento é necessário o conhecimento teórico e prático da dinâmica do processo. Assim um bom controlador depende também do emprego de uma técnica de identificação adequada.
848

Técnicas de modulação aplicada às estruturas de multiníveis com neutro grampeado e capacitor flutuante para redução de perdas e distorção harmônica / Modulation techniques applied to the multilevel structures with neutral clipped and floating capacitor for loss reduction and harmonic distortion

Henn, Gustavo Alves de Lima 30 April 2012 (has links)
Henn, G. A. de L. Técnicas de modulação aplicada às estruturas de multiníveis com neutro grampeado e capacitor flutuante para redução de perdas e distorção harmônica. 2012. 126 f. Tese (Doutorado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-17T18:00:37Z No. of bitstreams: 1 2012_tese_galhenn.pdf: 5303778 bytes, checksum: d9acd631a399249e02fb33418b525597 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T19:19:49Z (GMT) No. of bitstreams: 1 2012_tese_galhenn.pdf: 5303778 bytes, checksum: d9acd631a399249e02fb33418b525597 (MD5) / Made available in DSpace on 2012-09-25T19:19:49Z (GMT). No. of bitstreams: 1 2012_tese_galhenn.pdf: 5303778 bytes, checksum: d9acd631a399249e02fb33418b525597 (MD5) Previous issue date: 2012-04-30 / In order to overcome the challenge of processing electric energy in high power systems with minimal losses and high energy quality, this work presents the implementation and analysis of a modulation technique applicable on both most well-known multilevel inverter structures - neutral point-clamped (NPC), and flying capacitors (FC) - to reduce the stresses across the semiconductors devices, and to improve the total harmonic distortion of the output voltage. Throughout the work, the necessity to digitalize the proposed technique has been evidenced due to the high complexity and low reliability inherent to the analogical approach. Thus, the digital controller FPGA has been chosen, as it is easy to program and reconfigure, works at high speed, and has a lot of input and output pins. Additionally, other modulation techniques were also implemented to compare their performance with the proposed one, presenting the switching patterns and the behavior of the electrical currents through the semiconductors for each modulation. A theoretical analysis was also performed for both topologies and their respective operation principle, characteristics, and equations used on the losses analysis for the different combinations of modulation applied to each structure. Finally, the digital development of the various techniques has proved to be correct by observing the waveforms obtained through the digital/analogical circuit. Besides, the comparison of the modulation techniques on 6 kW NPC and FC three-level prototype inverters proved to be favorable to the proposed technique in terms of efficiency and total harmonic distortion reduction on both topologies, confirming its usefulness on high power multilevel converters. At last, it was presented the application of the proposed modulation technique to inverters with more than three levels, where it was observed its eligibility for n-levels topologies. / Visando superar os desafios inerentes à conversão de energia elétrica em sistemas de alta potência, minimizando as perdas e melhorando a qualidade da energia processada, este trabalho tem por objetivo analisar e implementar uma técnica de modulação para ser aplicada nas duas topologias de inversores multiníveis mais disseminadas - com neutro grampeado (NPC), e com capacitor flutuante (FC) - a fim de reduzir os esforços nos semicondutores, bem como melhorar o índice de distorção harmônica da tensão de saída. Ao longo do trabalho foi evidenciada a necessidade da digitalização da técnica proposta, visto que o desenvolvimento analógico da mesma acarretaria em um circuito complexo e de baixa confiabilidade. Dessa forma, escolheu-se como plataforma digital um FPGA, devido à sua facilidade de programação e reconfiguração, além da alta velocidade e quantidade de pinos de entrada e saída. Além da técnica proposta, foram também desenvolvidas outras modulações para fins de comparação, apresentando os padrões de chaveamento para cada uma delas, bem como o comportamento da corrente através dos semicondutores em cada período de chaveamento. Foi também realizada a análise teórica das topologias e suas respectivas etapas de operação, características e levantamento das equações que ditam a análise das perdas para as diferentes situações de técnicas aplicadas a cada uma das estruturas. O desenvolvimento digital das técnicas mostrouse correta através da análise das formas-de-onda colhidas por meio de um circuito digitalanalógico. Além disso, a comparação da aplicação dessas modulações em inversores a três níveis NPC e FC de 6 kW mostrou-se favorável à técnica proposta em termos de eficiência e redução da distorção harmônica em ambas as topologias, comprovando sua utilidade em conversores multiníveis de alta potência. Por fim, foi apresentado o desenvolvimento da técnica proposta em inversores com mais de três níveis, onde se pode comprovar sua eficiente aplicação para tais fins, bem como sua expansibilidade para inversores de n níveis.
849

Estudo de um sistema de nível com dois tanques interligados sujeito a perturbações utilizando desigualdades matriciais lineares / Study of a level system with two interconnected tanks subject to disturbances using linear matrix inequalities

Leite, Kelson de Sousa January 2012 (has links)
LEITE, K. de S. Estudo de um sistema de nível com dois tanques interligados sujeito a perturbações utilizando desigualdades matriciais lineares. 2012. 118 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-27T14:27:02Z No. of bitstreams: 1 2012_dis_ksleitel.pdf: 704572 bytes, checksum: dfae414bf5b1ba73b30022713f47b10c (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-27T16:28:29Z (GMT) No. of bitstreams: 1 2012_dis_ksleitel.pdf: 704572 bytes, checksum: dfae414bf5b1ba73b30022713f47b10c (MD5) / Made available in DSpace on 2012-09-27T16:28:29Z (GMT). No. of bitstreams: 1 2012_dis_ksleitel.pdf: 704572 bytes, checksum: dfae414bf5b1ba73b30022713f47b10c (MD5) Previous issue date: 2012 / The robust control theory has evolved considerably over the past decades, providing solutions for various problems of analysis, synthesis and performance of uncertain linear systems. The linear matrix inequalities (LMI) and its techniques have emerged as powerful tools in various areas of control engineering for structural projects. An important property of LMIs is the fact that its solution set is convex. This property is crucial in order to be able to make robust control problems as convex optimization problems that minimize an objective function. Given these statements the present work uses a liquid level system with two tanks connected to the plant where it was modeled, and then a controller is designed to ensure quadratic stability when subjected to external disturbances defined in an uncertain polytope. We used the linear quadratic regulator with integral action (LQI) as a controller, however, the concept of optimal LQR does not take into account the parametric uncertainties in the existing plant design, with it, was presented a method of solving the LQR using convex optimization. LQR optimized via LMI allows the addition of uncertainty to obtain the state feedback gain. The results obtained proved that the strategy of LQI control via LMI resolution is effective as robust control, because it can include features related to the imprecision of the process, moreover, the LQI control ensures the optimality of control. / A teoria de controle robusto evoluiu consideravelmente ao longo das últimas décadas, apresentando soluções para vários tipos de problemas de análise, desempenho e síntese de sistemas lineares incertos. As desigualdades matriciais lineares (LMIs) e suas técnicas surgiram como poderosas ferramentas em diversas áreas de engenharia de controle para projetos estruturais. Uma propriedade importante das LMIs reside no fato de que o seu conjunto solução é convexo. Esta propriedade é fundamental para que se possam formular problemas em controle robusto como sendo problemas de otimização convexa que minimizam uma função objetivo. Diante destas afirmações o presente trabalho utiliza um sistema de nível de líquido com dois tanques interligados como planta onde a mesma foi modelada, e, em seguida, foi desenvolvido um controlador para garantir a sua estabilidade quadrática, quando submetido a perturbações externas incertas definidas em um politopo. Utilizou-se o regulador linear quadrático com ação integral (LQI) como controlador, porém, o conceito ótimo do LQR não leva em consideração as incertezas paramétricas existentes nas plantas de projeto, com isso, foi apresentado um método de resolução do LQR utilizando otimização convexa. O LQR otimizado via LMIs permite a adição de incertezas para a obtenção do ganho de realimentação de estado. Os resultados obtidos comprovaram que a estratégia de controle LQI via resolução LMI é eficaz como controle robusto, pois é capaz de incluir características referentes à imprecisão do processo, além disso, o controle LQI garante a otimalidade do controle.
850

Sistema fotovoltaico de pequeno porte interligado à rede elétrica / A low power, grid-connected photovoltaic system

Terán, Eldin Mario Miranda 02 March 2012 (has links)
TERÁN, E. M. M. Sistema fotovoltaico de pequeno porte interligado à rede elétrica. 2012. 145 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-10-04T11:58:13Z No. of bitstreams: 1 2012_dis_emmterán.pdf: 3871183 bytes, checksum: 8eb985f68c890f6ca1b1c0134204761c (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-10-10T14:18:02Z (GMT) No. of bitstreams: 1 2012_dis_emmterán.pdf: 3871183 bytes, checksum: 8eb985f68c890f6ca1b1c0134204761c (MD5) / Made available in DSpace on 2012-10-10T14:18:02Z (GMT). No. of bitstreams: 1 2012_dis_emmterán.pdf: 3871183 bytes, checksum: 8eb985f68c890f6ca1b1c0134204761c (MD5) Previous issue date: 2012-03-02 / In the 21st century, the need of a more clean and environment friendly power matrix has become a very important issue. Therefore this work presents a two stage cc-ac converter for connecting a photovoltaic array to the electrical grid. The 1st stage it’s an isolated boost converter, based in the Three Stage Switching Cell (TSSC), in charge of boosting the photovoltaic array voltage from 48 Vcc to 400 Vcc and to track its maximum power point. The 2nd stage is a single-phase cc-ac Full-Bridge converter responsible of injecting the photovoltaic power into the low voltage power grid (220 Vac, 60 Hz). Both, theoretical analysis and designs examples of power and control circuits are presented for the two stages and, in order to validate the analysis, simulation results complemented with experimental results from an 850 W laboratory prototype are presented. The overall efficiency obtained from the prototype was 86.5% while the total harmonic distortion of the current obtained via simulation was 3.8% at full load. / A necessidade de obter uma matriz energética menos poluente e em harmonia com o meio ambiente é um tópico muito importante no século XXI. Este trabalho apresenta um conversor cc-ca de dois estágios para injetar a energia de um arranjo de painéis fotovoltaicos à rede elétrica. O primeiro estágio é um conversor elevador, isolado, baseado na Célula de Comutação de Três Estados (CCTE), responsável por elevar a tensão dos painéis fotovoltaicos de 48 Vcc para 400 Vcc e de extrair a máxima potência disponível deles. O segundo estágio consiste em um conversor monofásico cc-ca, ponte completa, responsável por injetar a energia na rede elétrica de baixa tensão (220 Vca, 60 Hz). São apresentados estudos teóricos e exemplos de projeto dos circuitos de potência e controle para ambos os estágios e, com o objetivo de validar a análise, são apresentados resultados de simulação computacional, complementados com resultados experimentais, correspondentes a um protótipo de laboratório de 850 W. O rendimento global obtido experimentalmente é aproximadamente 86,5% enquanto que a distorção harmônica total da corrente entregue à rede elétrica obtida via simulação computacional é 3,8% a plena carga.

Page generated in 0.0626 seconds