1 |
Parallel operation of A-C and D-C power transmissionPhadke, Arun G. January 1964 (has links)
Thesis (Ph. D.)--University of Wisconsin, 1964. / Typescript. Vita. eContent provider-neutral record in process. Description based on print version record. Bibliography: leaves 136-139.
|
2 |
Otimização do uso da linha de transmissão através do monitoramento em tempo real / Optimizing the use of transmission lines by real time monitoringCastilho, Renato Maioli 17 August 2018 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-17T05:27:30Z (GMT). No. of bitstreams: 1
Castilho_RenatoMaioli_M.pdf: 2356762 bytes, checksum: ada04c502811c2989682af0e17b5a512 (MD5)
Previous issue date: 2010 / Resumo: Este trabalho apresenta um método de análise do carregamento de linhas de transmissão aérea em tempo real o qual relaciona o respectivo carregamento da linha de transmissão com fatores externos que, direta ou indiretamente, exercem influência sobre os limites de operação da linha. Através da implementação de um sistema de monitoramento em uma linha de 230 kV da
Eletronorte, informações atmosféricas e da própria linha foram coletadas e transmitidas via cabo OPGW para um centro de controle onde, a partir de um software, obteve-se a ampacidade da linha em tempo real. Fazendo uso do banco de dados gerado com as informações coletadas pelo sistema de monitoramento e utilizando técnicas de redes neurais artificiais, foi desenvolvido um módulo preditor da temperatura superficial do cabo, possibilitando estimar a ampacidade da linha no curto prazo. A pesquisa se deu em três fases, na primeira foi feito o desenvolvimento dos equipamentos que compõem o sistema de monitoramento, na segunda fase foi feita a implementação do sistema na linha de 230 kV e na terceira fase foi dado o tratamento matemático às informações coletadas. A abordagem realizada dos dados obtidos pelo sistema de monitoramento proposto gerou resultados interessantes no que tange a busca pelo melhor aproveitamento da linha e mostrou ser um sistema bastante útil para a operação no despacho de carga. O sistema de monitoramento analisado neste trabalho de pesquisa, foi desenvolvido pelo Centro de Pesquisa e Desenvolvimento em Telecomunicações - CPqD em parceria com a Universidade Federal do Pará - UFPA e faz parte do programa de pesquisa e desenvolvimento das Centrais Elétricas do Norte do Brasil S.A. - Eletronorte. / Abstract: This paper presents a method of transmission line load analysis in real time, which relates of the transmission line loading with external factors that directly or indirectly exert influence over the operating range of the line. By setting up a monitoring system in a line of 230 kV, weather and line parameters information were collected and transmitted via OPGW cable to a control center where, using dedicated software, we obtained the ampacity of the line in real time.
Making use of the database generated with information collected by the monitoring
system and using techniques of artificial neural networks, we developed a predictor module surface temperature of the cable, allowing use to estimate the ampacity of the line in the short term. The research was divided in three phases, at first was developed the equipment that make up the monitoring system in the second round was implemented the monitoring system at 230 kV line and in the third stage was given the mathematical treatment of collected information. The data obtained by the proposed monitoring system, has generated interesting results allowing an optimized use of the line the system proved to be very useful for the line loading operation. The monitoring system of loading examined in this research work was developed by the Center for Research and Development in Telecommunications - CPqD in partnership with the Federal University of Pará - UFPA and is part of Centrais Elétricas do Norte do Brasil S.A - Eletronorte research and development program. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
3 |
Análise dos parâmetros elétricos e transitórios eletromagnéticos de linhas de transmissão compostas por torres com altura elevada / Analysis of the electrical parameters and electromagnetic transients of transmission lines consisting of towers with high heightPinto, André Jinno Gomes, 1983- 04 July 2011 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T03:00:37Z (GMT). No. of bitstreams: 1
Pinto_AndreJinnoGomes_M.pdf: 60896723 bytes, checksum: 8ce23cc18a981b5042b135acfc03ec42 (MD5)
Previous issue date: 2011 / Resumo: As redes de transmissão de energia elétrica estão entre as grandes contribuições que a engenharia ofereceu à civilização moderna. Se tornando aparentes, pelas expressivas linhas de transmissão de alta tensão apoiadas sobre elevadas torres de aço que cruzam o território nacional em todas as direções. No corrente trabalho tem-se por objetivo tratar das alternativas não-convencionais de transmissão de energia elétrica. Comparando o desempenho dessas novas estruturas com o comportamento das estruturas atualmente utilizadas no sistema de transmissão convencional. Para tal são descritos alguns dados da atual configuração do sistema de transmissão nacional. Ademais, breves descrições técnicas serão apresentadas sobre os principais componentes de linhas de transmissão convencionais, tais como: condutores múltiplos, isoladores e anéis anticorona. Tais definições serão introduzidas com o âmbito de proporcionar uma maior familiaridade com o tema em estudo. Uma análise minuciosa é traçada no cálculo dos parâmetros elétricos na frequência, seguido de um estudo dos transitórios eletromagnéticos no domínio do tempo. Causados por sinais de tensão aplicados a entrada das linhas de transmissão / Abstract: The transmission of electric energy is among the great contributions that engineering offered to modern civilization. Becoming apparent, by the expressive lines of high voltage transmission supported on large steel towers that crisscross the country in all directions. In the current work has been aimed at dealing with alternative non-conventional electric power transmission. Comparing the performance of these new structures with the behavior of the structures currently used in conventional transmission system. For such thing are described some of the current configuration of the national transmission system. In addition, brief technical descriptions are presented on the main components of conventional transmission lines, such as multiple conductors, insulators and anti-corona rings. Such definitions will be introduced to the scope of providing a greater familiarity with the subject under study. A detailed analysis is plotted on the calculation of electrical parameters on frequency, followed by a study of electromagnetic transient time domain. Caused by voltage signals applied to the input of the transmission lines / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
4 |
Modelagem de torres de transmissão utilizando análise numérica dos campos eletromagnéticos e funções racionais / Transmission towers modeling using numerical analysis of electromagnetic fields and rational functionsPinto, André Jinno Gomes, 1983- 24 August 2018 (has links)
Orientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T10:02:40Z (GMT). No. of bitstreams: 1
Pinto_AndreJinnoGomes_D.pdf: 9708757 bytes, checksum: 84772389fed6b8c0c68adcdd4db7cd9b (MD5)
Previous issue date: 2014 / Resumo: A análise do comportamento dinâmico da torre de transmissão de energia elétrica e torres de telecomunicações é de interesse nos estudos de proteção relacionados com descargas atmosféricas. Normalmente, a impedância de surto da torre no domínio do tempo é usada para caracterizar o comportamento dinâmico da torre. A principal desvantagem na definição de tais impedâncias de surto é a dependência da forma de onda de excitação, e não há consenso sobre a forma de onda de corrente a ser usada. Além disso, não há concordância sobre uma definição única da tensão envolvida. A fim de contornar tais limitações e problemas, o modelo aplicado ao estudo faz uso das análises no dominio da frequência, onde a impedância de surto da torre depende somente da geometria da estrutura e das características eletromagnéticas do meio. Ademais, as limitações associadas com as abordagens simplificadas são enfatizadas no decorrer do presente trabalho. Os resultados apresentados fazem uso de ferramentas computacionais como o código NEC-2 (Numerical Electromagnetic Code) que se baseia na análise numérica da dinâmica do campo eletromagnético. Com a utilização desse código, correntes são geradas e posteriormente utilizadas para o cálculo da impedância de surto da torre. Posteriormente, é gerado um circuito RLC representativo das características da estrutura metálica, obtidas pelo método de vector fitting que aproxima a função impedância de surto da torre por funções racionais. Por fim, o circuito RLC gerado pode ser aplicado nas análises diretamente no domínio do tempo com o uso de programas computacionais como o EMTP (Electromagnetic Transients Program), sem a necessidade do uso de transformadas para alterar o domínio de análise / Abstract: The dynamic analysis of the behavior in power transmission towers and telecommunications towers is of interest in studies related to lightning protection. Normally, the surge impedance of the tower in the time domain is used to characterize the dynamic behavior of the tower. The main disadvantage of these definition of surge impedances is the dependence on the waveform of excitation, and there is no consensus on which current wave to be used. Furthermore, there is no agreement on a single definition of the voltage involved. In order to overcome such limitations and problems, the model applied to the study makes use of the analysis in the frequency domain, where tower¿s surge impedance depends only on the geometry of the structure and electromagnetic characteristics of the medium. Moreover, the limitations associated with the simplified approaches are emphasized in the course of this work. The results presented make the use of computer code as NEC-2 (Numerical Electromagnetic Code) based on the numerical analysis of the electromagnetic field dynamics. Using this code, currents are generated and then used to calculate the surge impedance of the tower. Subsequently, an RLC circuit is generated representating the characteristics of the metal structure, obtained by vector fitting method, that approximates the surge impedance function of the tower by means of rational functions. Finally, the generated RLC circuit can be applied directly in analyzes in the time domain using computer programs such as EMTP (Electromagnetic Transients Program) without the need of using transforms to change domain analysis / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
5 |
Otimização de linhas de transmissão para manobra de abertura monopolar - análise da influência dos parâmetros transversais do sistema de compensação reativa / Optimization of transmission lines to single-phase opening maneuver - analysis of the influence of transversal parameters of shunt reactive compensation systemZevallos Alcahuaman, Milton Elvis, 1974- 03 January 2013 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:28:30Z (GMT). No. of bitstreams: 1
ZevallosAlcahuaman_MiltonElvis_D.pdf: 2479285 bytes, checksum: 4c1c5f42e8da1a073caee7cb88308479 (MD5)
Previous issue date: 2013 / Resumo: Uma solução bastante utilizada para reduzir a corrente de arco secundário nas linhas aéreas de transmissão em extra-alta-tensão após a ocorrência de faltas monofásicas não permanentes é a inserção de um reator de neutro no arranjo dos reatores dos bancos de compensação reativa em derivação da linha. Muitas vezes estes reatores de neutro não são otimizados, de modo que reatores com valores típicos são especificados nos projetos de linhas de transmissão aéreas, baseados simplesmente no seu nível de tensão, mas sem considerar as especificidades das linhas, como as suas características físicas ou o seu comprimento. A especificação inadequada do reator de neutro pode resultar em correntes de arco secundário elevadas, o que, em última análise, pode reduzir a taxa de sucesso da manobra de religamento monopolar. Além disto, o custo do sistema de compensação pode ser maior do que o necessário. A tese apresenta uma extensa análise de sensibilidade dos principais parâmetros que influenciam no dimensionamento de um tronco de transmissão longo, especificamente do nível de compensação mais adequado e do valor ótimo do reator de neutro. Destaca-se na pesquisa o desenvolvimento de uma representação dos componentes de um sistema de transmissão através de quadripolos trifásicos com o intuito de obter a resposta sustentada durante o desequilíbrio. Através desta representação foi possível identificar a relação entre o reator de neutro ótimo e os parâmetros transversais da linha de transmissão, assim como a influência direta entre o nível de compensação do sistema com o valor do reator de neutro otimizado. Adicionalmente foram identificados comprimentos limites para linhas não compensadas de diferentes níveis de tensão de modo a ainda apresentar alta probabilidade de sucesso para a manobra monopolar. Simulações de faltas monofásicas foram realizadas utilizando dados provenientes de linhas típicas do sistema elétrico brasileiro / Abstract: A widely used solution to reduce secondary arc current in the overhead transmission lines in EHV after single-phase non permanents faults is the insertion of a neutral reactor in the arrangement forming part of the shunt reactive compensation of the line. Frequently in Brazilian electrical system, neutral reactors are not optimized, so that reactors with typical values are specified in the project of overhead transmission lines based on their voltage level, but without considering the specifics line parameters, as their physical characteristics or their length. The specification of unsuitable neutral reactor can result in high secondary arc currents, which eventually diminishes the success rate of single-phase automatic reclosure (SPAR) maneuver. Moreover, the cost of the compensation system may be larger than necessary. This paper presents an extensive sensitivity analysis of the main parameters that influence the project of a long transmission trunk, specifically the most appropriate level of compensation and the optimal value of the neutral reactor. It is noteworthy the development of a transmission system components representation using three-phase two-ports networks in order to obtain sustained response during unbalance. Through this analysis it was possible to identify the relationship between the shunt reactor and the optimized neutral parameter and the influence of the compensation level with the neutral reactor optimized value. Additionally the maximum lengths of non-compensated lines that would have high probability of success of SPAR maneuver were identified. Simulations of single-phase faults were performed using data from typical lines of the Brazilian electric system / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
6 |
Caracterização de materiais descartados de redes de distribuição de eletricidade para fins de reciclagem /Rodrigues, Luciane Lopes. January 2010 (has links)
Orientador: Sandro Donnini Mancini / Banca: Maria Zanin / Banca: Helio Wiebeck / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Uma empresa que atua no setor de subtransmissão, tranformação e distribuição de eletricidade gera grandes quantidades de resíduos sólidos com a intalação, manutenção e reforma das suas redes elétricas. A destinação correta desses resíduos acarreta num custo associado para a empresa e preocupações concernentes à saúde pública. Através de pesquisa realizada em artigos científicos nacionais e internacionais verificou-se que existem muitos estudos sobre REEEs, porém não se encontrou estudo específico sobre os resíduos de redes de transmissão e distribuição de eletricidade. O objetivo deste trabalho foi realizar uma caracterização dos resíduos gerados, bem como estudos pontuais sobre algunsde modo a apontar procedimentos que visem a diminuição da geração e/ou a sua valorização enquanto sucata. Por exemplo, em 2009 o alumínio recoberto por polímero foi vendido por R$2,57/kg, já o nu por R$4,38/kg de modo que a sua separação do polímero poderia gerar uma receita de no mínimo 10% superior à obtida atualmente. Da separação do item "plásticos", que foi comercializado por R$0,006/kg, poderiam ser obtidas receitas da venda de polímeros valorizados no mercado de reciclagem, como o PET, policarbonato, PVC, polietileno. Para uma diminuição da geração de resíduos de equipamentos de proteção individual (EPIs) poderia haver a implementação de um padrão para evitar o descarte de produtos que ainda podem ser considerados em "bom estado". Foram escolhidos 3 resíduos para um estudo mais aprofundado sobre potencial de reciclagem a partir da comparação de propriedades fisico-químicas destes com materiais semelhantes antes do uso: isoladores poliméricos, isoladores de porcelana e abraçadeira ferrosa. O polímero do isolador foi identificado por ensaios de queima/fumaça, de espectroscopia no infravermelho e raios-X via microscopia eletrônica de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A company that operates in the sector os sub- transmission, transformation and distribution of electricy generates great amount of solid residues with the installation, maintenance and repair of your eletric lines. The correct diposal of this residues generates a associated cost to the company and concerns about public health. It was verified through a survey done in national and international scientific articles that there are manu studies about WEEEs, but a specific study about residues of transmission and distribution electricity lines wasn't found. The objective of this work to carry out a characterization of the residues generated, to execute specific studies on some residues to indicate procedures that aim at the reduction of the generation and/or the valorization of the scrap materials. In 2009, for instance, aluminum covered by polymer was sold at R$2.57/kg, while naked aluminum is sold at R$4.38/kg. Separation of the polymer would generate a gain of at least 10% above that of the current procedure. By separation of the "plastic" items, which were sold at R$0,06/kg, gains in polymer sales could obtained by recycling such materials as PET, polycarbonate, PVC and polyethylene. A suggestion the reduction in the generation of waste derived from personal protective equipmente would be to implement a standard to avoid discarding products considered in "good condition". Three residues had been chosen for a more in-depth study about the potential for recycling, comparing their physical and chemical properties with similar materials before usage: polymeric insulators, pordelain insaulators and ferrous cramp. The insulator polymer was identified by incinerationg assay, infrared spectroscopy and X-ray by scanning electron microscopy as silicon elastomer. Through density, thermogravimetry and differential scanning calorimetry it was verified that some degradation could have occurred during ... (Complete abstract click electronic access below) / Mestre
|
7 |
Wake-Induced Oscillations in Cable Structures: Finite Element ApproachSnegovskiy, Dmitri 11 June 2010 (has links)
In this work we consider the overhead power transmission lines (OHL). Their specifics are related to the presence of cables (conductors) whose length between supporting towers may extend to dozens of thousand meters. The OHL components are exposed to a combination of natural actions wind, rain, ice / snow / frost deposits. Compared to other structural parts, conductors have the highest flexibility and very low structural self-damping (of the order of 0.1 % of critical damping or lower, depending on frequencies). They are among structural elements the most sensitive to these actions.
Since early fifties the increased energy demand gave a rise to large construction of high-voltage and extra-high-voltage overhead lines equipped with bundled electrical conductors. For such arrangements there was noticed a kind of wind-induced oscillations originated by a zone of disturbed and retarded air flow (wake), that the cables located upwind(windward) cast onto the downwind (leeward) ones. The effect of this phenomenon called Wake-Induced Oscillations (WIO) resulted in fatigue damages of conductors, failures of insulator strings and cable suspension hardware and fatigue failures of spacers.
There have been identified analogues to transmission lines WIO in other regular structures subjectto the cross-flow of viscous fluids (air, gas, water etc.): heat exchanger tubes, clusters of fuel rods of nnuclear reactors, groups of chimneys, buildings. Early works in this field relate to the aerodynamics of tandem and staggered twin struts to support the wings of biplanes and published by Pannell, Griffits and Coales in 1915. Other cable structures like suspenders in suspension bridges or stays in cable-stayed bridges may be also subject to wake-induced oscillations. In each of these cases, conditions of oscillations occurrence and structural response depend on cables specific mass and stiffness, kind of fixation, dimension scale versus fluid viscosity and velocity (Reynolds number) etc. The cables separation plays important role, as there are different kinds of wake interference especially when the cables are closely spaced.
A number of research projects were entertained to study the wake-induced oscillations of different structures, which brought to development of analytical and experimental models and methods of protection against this phenomenon. A particular solution to overhead lines was found by unevenly distributing the spacers along the line span. To achieve that, no unique approach exists; virtually each grid company, or manufacturer of spacers proceeds with its own method. It may rely on different basis, either field experience or analytical study or a mixture of them. And, despite advances in numerical modelling of latest decades, few publications uncover phenomenological side of WIO.
The issues of modelling WIO in a view of helping to develop methods for protection of line against WIO are a main subject of this work.
Original advances studied in this thesis include:
- Current state-of-the art for analytical calculation of WIO, including the loads in the wake
- Overview of classic theory of wake-induced flutter and its evaluation from the standpoint of modern numerical tools for analytical applications (e.g., Matlab)
- Nonlinear Finite-Element Modelling of WIO using classic theory of wake-induced flutter,
study of its domains of application, advantages and limitations, including validation upon field experiments
- Foundation of basic methodology for optimal placement of spacers over the bundle conductor span
|
8 |
Caracterização de materiais descartados de redes de distribuição de eletricidade para fins de reciclagemRodrigues, Luciane Lopes [UNESP] 17 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:13Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-08-17Bitstream added on 2014-06-13T20:55:53Z : No. of bitstreams: 1
rodrigues_ll_me_bauru.pdf: 2682943 bytes, checksum: 5802af0dd19d1fa17fd905cc10b7f650 (MD5) / Eletropaulo / Uma empresa que atua no setor de subtransmissão, tranformação e distribuição de eletricidade gera grandes quantidades de resíduos sólidos com a intalação, manutenção e reforma das suas redes elétricas. A destinação correta desses resíduos acarreta num custo associado para a empresa e preocupações concernentes à saúde pública. Através de pesquisa realizada em artigos científicos nacionais e internacionais verificou-se que existem muitos estudos sobre REEEs, porém não se encontrou estudo específico sobre os resíduos de redes de transmissão e distribuição de eletricidade. O objetivo deste trabalho foi realizar uma caracterização dos resíduos gerados, bem como estudos pontuais sobre algunsde modo a apontar procedimentos que visem a diminuição da geração e/ou a sua valorização enquanto sucata. Por exemplo, em 2009 o alumínio recoberto por polímero foi vendido por R$2,57/kg, já o nu por R$4,38/kg de modo que a sua separação do polímero poderia gerar uma receita de no mínimo 10% superior à obtida atualmente. Da separação do item plásticos, que foi comercializado por R$0,006/kg, poderiam ser obtidas receitas da venda de polímeros valorizados no mercado de reciclagem, como o PET, policarbonato, PVC, polietileno. Para uma diminuição da geração de resíduos de equipamentos de proteção individual (EPIs) poderia haver a implementação de um padrão para evitar o descarte de produtos que ainda podem ser considerados em bom estado. Foram escolhidos 3 resíduos para um estudo mais aprofundado sobre potencial de reciclagem a partir da comparação de propriedades fisico-químicas destes com materiais semelhantes antes do uso: isoladores poliméricos, isoladores de porcelana e abraçadeira ferrosa. O polímero do isolador foi identificado por ensaios de queima/fumaça, de espectroscopia no infravermelho e raios-X via microscopia eletrônica de... / A company that operates in the sector os sub- transmission, transformation and distribution of electricy generates great amount of solid residues with the installation, maintenance and repair of your eletric lines. The correct diposal of this residues generates a associated cost to the company and concerns about public health. It was verified through a survey done in national and international scientific articles that there are manu studies about WEEEs, but a specific study about residues of transmission and distribution electricity lines wasn't found. The objective of this work to carry out a characterization of the residues generated, to execute specific studies on some residues to indicate procedures that aim at the reduction of the generation and/or the valorization of the scrap materials. In 2009, for instance, aluminum covered by polymer was sold at R$2.57/kg, while naked aluminum is sold at R$4.38/kg. Separation of the polymer would generate a gain of at least 10% above that of the current procedure. By separation of the plastic items, which were sold at R$0,06/kg, gains in polymer sales could obtained by recycling such materials as PET, polycarbonate, PVC and polyethylene. A suggestion the reduction in the generation of waste derived from personal protective equipmente would be to implement a standard to avoid discarding products considered in good condition. Three residues had been chosen for a more in-depth study about the potential for recycling, comparing their physical and chemical properties with similar materials before usage: polymeric insulators, pordelain insaulators and ferrous cramp. The insulator polymer was identified by incinerationg assay, infrared spectroscopy and X-ray by scanning electron microscopy as silicon elastomer. Through density, thermogravimetry and differential scanning calorimetry it was verified that some degradation could have occurred during ... (Complete abstract click electronic access below)
|
9 |
Controle adaptativo para religamento tripolar aplicado a linhas de transmissão com compensação reativa em derivação / Adaptive control for three phase reclosing applied to shunt reactor compensated transmission linesMestas Valero, Patricia 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T10:56:05Z (GMT). No. of bitstreams: 1
MestasValero_Patricia_D.pdf: 4018272 bytes, checksum: 38a65b52b68046f67c3791c9b6ea2f7d (MD5)
Previous issue date: 2011 / Resumo: O presente trabalho descreve um novo método de controle adaptativo para chaveamento sincronizado de disjuntores durante a manobra de religamento tripolar de linhas de transmissão com compensação reativa em derivação. O objetivo principal do método desenvolvido é controlar as sobretensões transitórias e reduzir o tempo morto antes do religamento. Diferentes estratégias para controlar sobretensões decorrentes do religamento tripolar são descritas com a finalidade de diferenciar as vantagens do chaveamento sincronizado. Os benefícios potenciais a serem obtidos a partir do religamento tripolar rápido são expostos. O método de controle adaptativo desenvolvido consiste em identificar com antecedência a região ótima para o religamento, permitindo fechar o disjuntor já no primeiro mínimo do batimento da tensão entre os contatos do disjuntor após o tempo morto de atuação da proteção. Após os testes realizados utilizando um programa para simulação de transitórios eletromagnéticos (PSCAD/EMTDC), o método proposto foi implementado em protótipo (controlador). Este protótipo foi testado utilizando o Simulador Digital em Tempo Real (RTDS). As simulações em tempo real demonstraram a eficiência do método no controle das sobretensões e na redução do tempo morto. Finalmente, o método foi avaliado parametricamente para uma série de condições simuladas, incluindo diferentes níveis de compensação reativa em derivação, a influência da compensação série, a influência da transposição da linha de transmissão e os efeitos da variação do comprimento da linha. Além disto, outras simulações foram realizadas para comparar o desempenho dos métodos de controle existentes e do método proposto / Abstract: The present thesis describes a new adaptive control method for synchronous switching of circuit breakers during three-phase reclosing of shunt compensated transmission lines. The main objective of the developed method is to control the overvoltages and to reduce the dead time prior of reclosing. Several strategies to control overvoltages resulting from three-phase reclosing are described in order to differentiate the benefits of the proposed method. The potential benefits obtained from the developed controlled reclosing method are exposed. The proposed algorithm identified, in advance, the optimal region for reclosing of transmission line, allowing closing the circuit breaker at the first minimum voltage beat across circuit breaker, after protection dead time. After off-line testing using electromagnetic transients simulation program (PSCAD/EMTDC), the proposed method was also implemented in physical hardware. This hardware was then tested on a real-time transients simulator (RTDS). The real time simulations demonstrate the method efficiency to control overvoltages and to reduce the dead time. Finally, the method has been parametrically evaluated for a range of simulated conditions, including different shunt compensation levels, influence of series compensation, influence of transmission line transposition, effect of line lengths. In addition, simulations have been conducted to compare the performance of existing control method and the proposed method / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
10 |
Influência da condutividade e permissividade do solo em função da frequência no cálculo da impedância longitudinal e admitância transversal de linhas aéreas de transmissão / Influence of earth's conductivity and permittivity frequency dependence on longitudinal impedance and transversal admittance transmission line's parameters calculationGertrudes, João Bosco 16 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T03:57:35Z (GMT). No. of bitstreams: 1
Gertrudes_JoaoBosco_D.pdf: 5500576 bytes, checksum: ef85206048f845d1bff89f7c8948d288 (MD5)
Previous issue date: 2010 / Resumo: Esta tese tem como objetivo o desenvolvimento de modelos mais precisos para o cálculo de parâmetros elétricos de linhas aéreas de transmissão para estudos de transitórios na faixa de frequência 0 a 2 MHz. Esta faixa de frequência cobre a maioria das perturbações eletromagnéticas nos sistemas elétricos: energização, faltas simétricas e assimétricas, rejeições de carga, descargas atmosféricas, perturbações harmônicas, etc. Na faixa de frequência citada, em consequência da dependência dos parâmetros do solo com a frequência, a condutividade elétrica do solo (sg) tem a mesma ordem de grandeza que o produto entre a frequência angular do sinal incidente no solo (w) e a permissividade elétrica do solo (eg). Portanto, as suposições de baixa frequência tradicionalmente adotadas - sg constante e weg desprezível (sg >> weg) - podem levar a modelos que não representam de forma adequada a resposta da linha no caso de transitórios rápidos (com espectro de frequência acima de 1 kHz). O objetivo central desta tese é verificar a influência da dependência dos parâmetros do solo no cálculo da impedância longitudinal e admitância transversal por unidade de comprimento em comparação com os modelos tradicionais de cálculo. As análises são feitas inicialmente para o caso de um único condutor acima do solo e posteriormente através de um estudo para uma linha de transmissão trifásica, 440 kV, em operação no sistema elétrico brasileiro. As impedâncias longitudinais e as admitâncias transversais de retorno pelo solo são avaliadas através de métodos tradicionais de cálculo e através de integração numérica das formulações de Carson modificadas para inclusão do modelo de solo que considera a depêndencia de sg e weg em função da frequência / Abstract: This thesis aims to propose more accurate models for calculating the electrical parameters of overhead power transmission lines. The influence of earth's conductivity and permittivity frequency dependence is evaluated when calculating transversal and longitudinal transmission lines' parameters in the frequency range 0 to 2 MHz. This frequency range covers the majority of the electromagnetic transients in electrical systems (switching transients, faults' transients, load rejections, harmonic disturbances, etc). Between 1 kHz to 2 MHz, the product of the signal angular frequency (w) by the dielectric constant (eg) of the soil may have the same order of magnitude as the conductivity (sg), due to the variation of these parameters with frequency. Therefore, the assumptions of low frequency traditionally used - the soil conductivity (sg) considered as constant and weg that can be negligible (sg >> weg) - can lead to incorrect models that do not adequately represent the transmission line's response, in cases of fast transients phenomena (with frequency spectrum above 1 kHz). The importance of properly considering the frequency dependent soil model is presented for the one-conductor case and for a single three-phase transmission line (440 kV, considered ideally transposed). The aim is to compare the transmission line parameters calculated considering the conductivity and weg frequency dependence ground model in relation to the common ground representation, with constant conductivity and weg that may be neglected. It is also compared the results obtained from the complex plane method with those obtained from the Carson's modified expressions for longitudinal parameters and between Carson's modified potential-coefficient correction factors and from the most common approximated methods for transversal admittance parameters / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|