81 |
Eletronarcose no abate de frangos de corte: Iderlipes Luiz Carvalho Bossolani. -Bossolani, Iderlipes Luiz Carvalho [UNESP] 26 May 2015 (has links) (PDF)
Made available in DSpace on 2016-05-17T16:51:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-05-26. Added 1 bitstream(s) on 2016-05-17T16:54:42Z : No. of bitstreams: 1
000864242.pdf: 1971708 bytes, checksum: b9c287857eb37a0b68b044b0e18c35fa (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Eletronarcosis by water bath is the electrical stunning method most widely accepted and used in chicken slaughterhouses in most countries of the world. Although it is provided for Brazilian law, legislation that rules the stunning methods for humanitarian slaughter, this method causes stress for the birds, such as hanging and drowning. This study aimed to investigate the feasibility and effectiveness of an electrical stunning device, by direct contact, using alternating current (AC) applied in the bird standing, and evaluate their implications on the intrinsic characteristics of chicken meat. Fifty six birds (Cobb 500, 42 days of age) were slaughtered, in a completely randomized design featuring factorial arrangement 2 by 2 by 2, being two forms of electrical current application, two frequency parameters, and both sexes. The results were analyzed based on the ANOVA methodology, with a significance level of 5% and Duncan's test. There is a significant linear correlation between the amperage and the weight of the animals. There was no statistical difference in terms of blood glucose level, meat color, drip loss of fluid content, water holding capacity, cooking loss, and shear force for both sexes submitted to the different methods of electrical stunning. The stunning system by direct contact is viable as regards the humanitarian slaughter assurance for the birds, without damage in the quality of the final product. However, studies involving its mechanization, in order to integrate into the packing industry, are needed / FAPESP: 2013/07186-2
|
82 |
Estudo randomizado do uso da estimulação elétrica nervosa transcutânea (TENS) no alívio da dor no trabalho de partoCappeli, Angela Juliana January 2018 (has links)
Orientador: Vera Therezinha Medeiros Borges / Resumo: Objetivo: Avaliar a eficácia da aplicação da estimulação elétrica nervosa transcutânea (TENS) no controle da dor durante o período da dilatação do trabalho de parto. Método: Foi realizado um ensaio clínico, paralelo e randomizado. Sessenta e oito parturientes com gestação única, de baixo risco, no termo, com dilatação cervical ≥ 4 cm e ≤ 7 cm e sem uso de medicação analgésica prévia. Foram randomizadas em dois grupos: TENS (n=34) e placebo (n=34) e avaliados os desfechos primários (intensidade da dor após a intervenção, grau de desconforto e grau de satisfação materna) e secundários (uso de outros métodos não farmacológicos para alívio da dor, fármacos no parto vaginal, taxa de cesárea e duração do trabalho de parto). A TENS foi aplicada por 30 minutos, entre T10 – L1 e S2 – S4. A intensidade da dor e o grau de desconforto foram avaliados por meio da escala visual analógica (EVA) e o grau de satisfação materna por nota de 0 a 10. Considerando a diferença de 34% entre os grupos para detectar efetividade do tratamento e assumindo a margem de erro de 10% e confiabilidade de 95%, o tamanho amostral calculado foi de 34 parturientes por grupo. Os resultados foram analisados estatisticamente para comparação entre os grupos estudados, adotando-se o limite mínimo de significância de 95% (p<0,05) Resultados: No grupo TENS houve maior número de parturientes classificando a dor como leve/moderada (RR= 2,4; IC95%: 1,6-3,7), melhora do grau de desconforto (RR= 4,1; IC95%: 2,1-8,1), maior n... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To evaluate the efficacy of transcutaneous electrical nerve stimulation (TENS) in the control of pain during the period of labor. Method: A clinical, parallel and randomized trial was performed. Sixty-eight parturients with single, low-risk pregnancies at term, with cervical dilatation ≥ 4 cm and ≤ 7 cm and without previous analgesic medication. They were randomized into two groups: TENS (n = 34) and placebo (n = 34) and primary outcomes (pain intensity after intervention, degree of discomfort and degree of maternal satisfaction) and secondary outcomes (use of other non-pharmacological methods for pain relief, vaginal delivery drugs, cesarean section rate and duration of labor). The TENS was applied for 30 minutes between T10 - L1 and S2 - S4. The intensity of the pain and the degree of discomfort were evaluated through the visual analogue scale (VAS) and the degree of maternal satisfaction by grade from 0 to 10. Considering the difference of 34% between the groups to detect treatment effectiveness and assuming the margin of error of 10% and reliability of 95%, the sample size calculated was 34 parturients per group. The results were statistically analyzed for comparison between the groups studied, adopting the minimum significance level of 95% (p <0.05). Results: In the TENS group, there was a higher number of parturients classifying pain as mild / moderate (RR = 2.4, 95% CI: 1.6-3.7), improvement in the degree of discomfort (RR = 4.1, 95% CI, (RR = 2.8, 95% CI: 1... (Complete abstract click electronic access below) / Mestre
|
83 |
Estimulação transcraniana por corrente contínua em voluntárias com disfunção temporomandibular do tipo muscular: ensaio clínico aleatorizado do tipo cruzado duplo cegoBrandão Filho, Rivail Almeida 10 December 2015 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2016-08-30T16:25:53Z
No. of bitstreams: 1
Rivail Almeida Brandão Filho-Tese.pdf: 2200723 bytes, checksum: ae639ad771ff38a9deb4b4fcdaa9eeae (MD5) / Made available in DSpace on 2016-08-30T16:25:53Z (GMT). No. of bitstreams: 1
Rivail Almeida Brandão Filho-Tese.pdf: 2200723 bytes, checksum: ae639ad771ff38a9deb4b4fcdaa9eeae (MD5) / As disfunções temporomandibulares são um grupo de condições de dor orofacial comuns na
população em geral. Assim como muitas outras disfunções com dor crônica, a DTM parece
estar associada ao quadro de ansiedade/depressão. Este pode estar relacionado com alterações
na atividade do córtex pré-frontal dorsolateral. Em alguns casos, os medicamentos que atuam
no sistema nervoso central são úteis, apesar dos efeitos adversos associados que produzem.
No entanto, a medicação não é eficaz para todos os casos. Alguns estudos demonstraram
melhora clínica em pacientes com dor crônica, submetidos à neuromodulação terapêutica. A
estimulação transcraniana por corrente contínua é uma técnica de estimulação cerebral não
invasiva que permite a modulação das membranas neuronais. Esta terapia pode aumentar ou
inibir o potencial de ação dos neurônios corticais. Assim, torna-se importante testar se a
ETCC catódica sobre o CPFDL direito, área que modula a emoção e a excitabilidade do
córtex motor, tem efeito analgésico em voluntárias com DTM muscular. Dezoito mulheres
(36,5 anos, dp= 12,3), com DTM muscular crônica, participaram deste ensaio clínico
controlado aleatorizado do tipo cruzado duplo cego. Foram incluídas voluntárias que tiveram
pontuação da escala visual analógica de dor de 4 a 10, presente nos últimos 6 meses, e com
pontuação do Iventário de Depressão e Ansiedade- Traço-Estado superior a 42. Cada
voluntária recebeu ETCC ativa (1 mA e 2 mA) e sham (placebo). A influência da ETCC foi
avaliada mediante EVA-dor, IDATE, testes sensoriais quantitativos e eletroencefalograma
quantitativo. Usando os testes de Wilcoxon e de Friedman, não se observaram diferenças
significativas dentro e entre os três grupos de tratamento para EVA e testes sensoriais. O
IDATE diminuiu significativamente após todos os parâmetros de ETCC (p <0,01), mas não
houve diferença entre os tipos de intervenção (p = 0,86). Com base nos resultados do EEGq
para um subgrupo de nove voluntárias, não houve efeito de quaisquer parâmetros de ETCC
em teta, alfa e beta. Em conclusão, não se observou efeito analgésico da ETCC catódica sobre
a CPFDL direito das voluntárias com DTM muscular crônica. Dada a amostra de
conveniência, os resultados dos ensaios devem ser interpretados com cautela.
|
84 |
Influência da estimulação elétrica transcutânea sobre a ossificação heterotópica : estudo esperimental em ratos / Talita Gianello Gnoato ; orientador, Josuê Bruginski de PaulaGnoato, Talita Gianello January 2011 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Bibliografia: f. 74-88 / A ossificação heterotópica (OH) é definida como um processo biológico metaplásico, no qual há neoformação de osso em tecidos moles adjacentes às grandes articulações, onde normalmente o tecido ósseo não é Encontrado, o que acarreta em déficit da mobilidad / Heterotopic ossification (HO) is defined as a metaplastic biological process in which there is newly formed bone in soft tissues adjacent to large joints, usually where no bone tissue is found, resulting in joint mobility deficit and, in some cases, inten
|
85 |
Efeitos imediatos do “Biofeedback” e da eletroestimulação anorretal no tratamento da contração paradoxal da musculatura puborretal em mulheres com evacuação obstruída / Immediate effects of the "Biofeedback and electrostimulation in treating anorectal paradoxical contraction of the muscles in women with blocked evacuation puborretalMagalhães, Germana Mesquita 22 April 2013 (has links)
MAGALHÃES, G. M. Efeitos imediatos do “Biofeedback” e da eletroestimulação anorretal no tratamento da contração paradoxal da musculatura puborretal em mulheres com evacuação obstruída. 2013. 71 f. Dissertação (Mestrado em Cirurgia) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-07-27T13:44:02Z
No. of bitstreams: 1
2013_dis_gmmagalhaes.pdf: 1141746 bytes, checksum: a3db37c95fce54fa04ee860f63749158 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-07-27T13:44:34Z (GMT) No. of bitstreams: 1
2013_dis_gmmagalhaes.pdf: 1141746 bytes, checksum: a3db37c95fce54fa04ee860f63749158 (MD5) / Made available in DSpace on 2016-07-27T13:44:34Z (GMT). No. of bitstreams: 1
2013_dis_gmmagalhaes.pdf: 1141746 bytes, checksum: a3db37c95fce54fa04ee860f63749158 (MD5)
Previous issue date: 2013-04-22 / This study was conducted to evaluate the effects of "biofeedback" and electrostimulation in reversing muscle contraction paradoxical puborectalis. The study involved 31 women from the Clinic of Coloproctology Walter Cantídio University Hospital, Federal University of Ceará and the Center for Gastroenterology and Coloproctology of Ceará, in the period August 2010 to July 2012, with 28 to 64 years of age, who met the Rome III criteria and presented, eletromanométrico examination, presence of contraction to maneuver defecation. Were randomized into three groups: group I conventional treatment of constipation, group II conventional treatment of constipation associated with "biofeedback", Group III conventional treatment of constipation associated with electrical stimulation. At baseline and after six weeks of treatment, we assessed the subjective and objective parameters of anorectal function by means of the scoring system for constipation Wexner scale to Bristol stool consistency, visual analog scale and anorectal electromanometry. All patients demonstrated improvement in bowel satisfaction, stool frequency, effort and feeling of incomplete evacuation, stool-type modifications and improvement in quality of life (p <0.05). On examination there was increased pressure eletromanométrico average voluntary contraction in group III (p = 0.043), decreased sensitivity threshold in group II (p = 0.025) and in group III (p = 0.012) and decreased rectal capacity maximum in group II (p = 0.005). Only 19.4% (n = 6) normalized dynamic defecation, and 80.6% (n = 25) expressed clinical improvement and not instrumental. The results confirmed that the "biofeedback" and electrostimulation are valuable treatment options and impact on quality of life of these patients. The "biofeedback" was more effective than electrical stimulation, which in turn is more effective than conventional treatment for constipation. Further randomized, controlled, long-term are needed to confirm the results. In the future, studies with the combination of therapeutic modalities may be a therapeutic option more sustainable and effective. / Esse estudo foi realizado com o objetivo de avaliar os efeitos do “biofeedback” e da eletroestimulação na reversão da contração paradoxal da musculatura puborretal. Foram avaliadas 31 mulheres provenientes do Ambulatório de Coloproctologia do Hospital Universitário Walter Cantídio da Universidade Federal do Ceará e do Centro de Coloproctologia e Gastroenterologia do Ceará, no período agosto de 2010 a julho de 2012, com 28 a 64 anos de idade, que preenchiam os critérios de Roma III e apresentavam, ao exame eletromanométrico, presença de contração à manobra evacuatória. Foram randomizadas em três grupos: grupo I tratamento convencional da constipação, grupo II tratamento convencional da constipação associado ao “biofeedback”, grupo III tratamento convencional da constipação associado à eletroestimulação. No início e após seis semanas do tratamento, foram avaliados os parâmetros subjetivos e objetivos da função anorretal, por meio do sistema de pontuação para constipação de Wexner, escala de Bristol para consistência de fezes, escala analógica visual e eletromanometria anorretal. Todas as pacientes demonstraram melhora da satisfação intestinal, frequência evacuatória, esforço e sensação de evacuação incompleta, modificações do tipo de fezes e melhora da qualidade de vida (p<0,05). Ao exame eletromanométrico houve aumento da pressão média de contração voluntária no grupo III (p=0,043), diminuição do limiar de sensibilidade no grupo II (p=0,025) e no grupo III (p=0,012) e diminuição da capacidade retal máxima no grupo II (p=0,005). Somente 19,4% (n=6) normalizaram a dinâmica evacuatória, e 80,6% (n=25) expressaram melhora clínica e não instrumental. Os resultados confirmaram que o “biofeedback” e a eletroestimulação são opções terapêuticas valiosas e de impacto na qualidade de vida destes pacientes. O “biofeedback” foi mais eficaz do que a eletroestimulação, que é por sua vez mais eficaz do que tratamento convencional para constipação. Maiores estudos randomizados, controlados e em longo prazo são necessários para confirmar os resultados. No futuro, estudos com a associação das modalidades terapêuticas pode ser opção terapêutica mais duradoura e eficaz.
|
86 |
Efeitos da estriatotomia posterior estereotáxica unilateral no tremor induzido pela harmalina em ratos / Effects of unilateral stereotactic posterior striatotomy on harmaline-induced tremor in ratsVilela Filho, Osvaldo [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:46:12Z (GMT). No. of bitstreams: 0
Previous issue date: 2006 / Objetivos: Embora compreenda a mais prevalente desordem do movimento, a fisiopatologia do tremor essencial (TE) e ainda controversa. Conforme a hipotese mais aceita, trata-se de um tremor central causado por uma disfuncao do complexo olivar inferior, provavelmente secundario a uma hipofuncao do sistema GABAergico. Vilela Filho et al (2001), por outro lado, relataram o caso de uma paciente com TE da mao direita que foi completamente eliminado apos uma isquemia restrita ao putamen posterior contralateral e sugeriram que o TE poderia representar a manifestacao clinica da hiperatividade do putamen posterior. O presente estudo foi realizado para testar essa hipotese no mais frequentemente usado modelo animal de TE, o tremor induzido pela harmalina em ratos e, empregando-se o mapeamento fisiologico por estimulacao, melhor determinar a organizacao somatotopica do striatum no rato. Metodos: 54 ratos Wistar machos (peso=250-350g) foram aleatoriamente distribuidos em tres grupos: experimental-GE (n=26), controle cirurgico-GCC (n=18) e controle farmacologico-GCF (n=10). Animais do GE foram submetidos a estriatotomia posterior estereotaxica unilateral (coordenadas: 1.8mm posterior/4.6mm lateral/5.85mm inferior; eletrodo: 0.35mm em diametro externo e 1.0mm de ponta exposta; parametros da lesao eletrolitica: 5.0mA/6o/60Hz) apos estimulacao eletrica do alvo (parametros: 0.2, 0.5, 1.0 e 2.0mA/monopolar/6o/60Hz). Nos animais do GCC, o eletrodo foi introduzido no alvo e retirado, sem se proceder a estimulacao ou lesao. Animais do GCF serviram apenas como controles para os efeitos da harmalina, nao tendo sido operados. Todos os animais (7o dia pos-operatorio naqueles operados) receberam harmalina intraperitonial (20mg/kg/ml), tendo sido o tremor induzido filmado 45 e 110 minutos apos sua administracao. A intensidade do tremor apendicular foi avaliada, independentemente, por um observador ocegoo, enquanto a dos tremores axiais, bem como a latencia e duracao de todos os tremores, pelos pesquisadores. Apos o teste da harmalina, os animais do GE e GCC foram sacrificados e seus cerebros enviados para o exame histopatologico. Resultados: Conforme criterios estabelecidos, 13 animais foram excluidos do estudo. O tremor apendicular mostrou-se reduzido ipsolateralmente a cirurgia em 20/21 animais do GE e em 2/9 do GCC e assimetrico em 1/10 do GCF; tais diferencas foram estatisticamente significantes entre GE e GCC e GE e GCF, mas nao entre GCC e GCF. Curiosamente, a latencia e duracao dos tremores axiais foram menores no GCF que no GE e GCC. A percentagem de reducao media do tremor apendicular foi 43.70%±14.22, tendo sido maior nas patas anteriores que posteriores e apos a estriatotomia posterior direita que esquerda. Lesoes estriatais laterais proporcionaram melhores resultados que as mediais. Conclusoes: Esses resultados sao sugestivos de uma provavel participacao do striatum posterior no tremor induzido pela harmalina em ratos e reforcam a hipotese determinante da realizacao do presente estudo. Os resultados derivados do mapeamento fisiologico estriatal por estimulacao e da resposta do tremor a cirurgia, por sua vez, sugerem a seguinte organizacao somatotopica no striatum dorsal do rato: patas dianteiras (muito provavelmente superpostas), posteriores e ventrais; tronco e cauda, anteriores; e patas traseiras, em posicao intermediaria entre as duas anteriores, anterior e dorsalmente as patas dianteiras, situando-se a contralateral posteriormente a ipsolateral / Purposes: Although the most prevalent movement disorder, the pathophysiology of essential tremor (ET)
remains controversial. The most accepted hypothesis is that it is a central tremor caused by a dysfunction
of the inferior olivary complex, probably secondary to GABAergic system malfunctioning. Evidence for the
involvement of the basal ganglia had never been presented. Vilela Filho et al (2001), though, reported a
case of a patient with unilateral hand ET which was completely relieved after a stroke restricted to the
contralateral posterior putamen and suggested that ET could be the clinical manifestation of posterior
putamen hyperactivity. The present study was designed to evaluate this hypothesis in the most used
model of ET, harmaline-induced tremor in rats, and, by stimulation mapping, to better determine the
somatotopic organization of the rat striatum. Methods: 54 male Wistar rats, 250-350g, were randomly
distributed in three groups: experimental-EG (n=26), surgical control-SCG (n=18), and pharmacological
control-PCG (n=10) groups. EG animals underwent stereotactic unilateral posterior striatotomy
(coordinates: 1.8 posterior/4.6 lateral/5.85mm inferior; electrode: 0.35mm in external diameter and 1.0mm
exposed tip; electrolytic lesion parameters: 0.5mA/6”/60Hz) after target stimulation (parameters: 0.2, 0.5,
1.0, and 2.0mA/monopolar/6”/60Hz). SCG rats underwent electrode placement at the target and
withdrawn without stimulation or lesioning (sham lesion). PCG served exclusively as controls for
harmaline effects. All animals received (7th postoperative day in those of EG and SCG) IP harmaline
(20mg/kg/ml) and the induced-tremor was video recorded 45` and 110` after the injection. Limb tremor
intensity was independently evaluated by a blind observer, while axial tremors intensity, as well as latency
and duration of both limb and axial tremors, were evaluated by the researchers. Animals of EG and SCG
were killed after harmaline test and their brains sent to histopathology. Results: Obeying predetermined
criteria, 13 animals were excluded from the study. Limb tremor was reduced ipsolaterally to the operation
in 20/21 rats of EG and in 2/9 of SCG, and was asymmetric in 1/10 of PCG. Comparisons between EG x
SCG and EG x PCG were statistically significant, but not between SCG x PCG. None of the rats
presented tremor reduction contralateral to the operation. Curiously, latency and duration of axial tremors,
but not of limb tremor, were lesser in PCG than in EG and SCG. The mean percentage of limb tremor
reduction in animals of EG was 43.7%±14.22, being greater in anterior than in posterior paws, and after
right than left striatotomy. Lateral lesions yielded better results than medial lesions. Conclusions: These
results suggest that the posterior striatum is possibly involved with harmaline-induced tremor in rats and
give support to our hypothesis, according to which hyperactivity of the posterior putamen may play a role
in the genesis of ET. Data provided by stimulation mapping and tremor response to operation suggest the
following somatotopic organization in the rat dorsal striatum: forepaws (probably overlapped), caudal and
ventral; trunk and tail, rostral; and hind paws, in an intermediary position, dorsal and rostral to the
forepaws, being the contralateral one caudal to the ipsolateral. / BV UNIFESP: Teses e dissertações
|
87 |
Estimulação elétrica nervosa transcutânea de alta e baixa frequências nos vasos sanguíneos e nos miofibroblastos de ferida excisional aguda em pele de ratos / High and low frequency of transcutaneous electrical nerve stimulation on the blood vessels and myofibroblasts of acute excisional wounds in ratsÆ skinMachado, Aline Fernanda Perez [UNIFESP] January 2013 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:46:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2013 / Introdução: Os efeitos da Estimulacao Eletrica Nervosa Transcutanea (TENS) no processo de cicatrizacao de feridas tem sido estudados para determinar os principais eventos responsaveis pelo reparo tecidual. Objetivo: Avaliar o efeito da TENS de alta e de baixa frequencias nos vasos sanguineos e nos miofibroblastos de ferida excisional aguda em pele de ratos. Metodos: Foram utilizados 90 ratos (Wistar-EPM1) machos e adultos. Realizou-se uma ferida excisional na regiao dorsal do animal utilizando um punch medindo 8 milimetros. Os animais foram aleatorizados em 3 grupos: Grupo Alta frequencia (GA: 80 Hz), Grupo Baixa frequencia (GB: 5 Hz) e Grupo Simulado (GS: TENS desligada); e submetidos a TENS por 3 dias consecutivos. A duracao do pulso e intensidade da corrente foram 200 μs e 15 mA, respectivamente; durante 60 minutos. Foram realizadas analises imunohistoquimicas para quantificacao dos vasos sanguineos e dos miofibroblastos, aos 3, 7 e 14 dias de PO. Resultados: Aos 3 dias de PO, o GB apresentou maior quantidade de vasos sanguineos em relacao ao GA; aos 7 e 14 dias de PO, o GA demonstrou menor quantidade de vasos sanguineos em relacao ao GS. O GA apresentou menor quantidade de miofibroblastos comparado com o GB e o GS aos 3 dias de PO e comparado ao GS aos 7 dias de PO. Conclusao: A TENS de baixa frequencia aumentou a quantidade de vasos sanguineos aos 3 dias de PO e a de alta frequencia inibiu os vasos sanguineos e os miofibroblastos de ferida excisional aguda em pele de ratos / Introdution: The effects of Transcutaneous Electrical Nerve Stimulation
(TENS) on the wound healing process have been studying to verify the
most important events to tissue repair. Objective: To assess the effect of
high- and low-frequency TENS on the angiogenesis and myofibroblasts of
acute excisional wounds in rats’ skin. Methods: Ninety young adult male
EPM1-Wistar rats were used in the study. An excisional wound was
performed on the back of each animal using an 8-mm punch. The animals
were randomly assigned to three groups: the High-frequency Group (HG:
80 Hz), Low-frequency Group (LG: 5 Hz), and Sham Group (SG: TENS
turned off). TENS was delivered on three days: in the immediate
postoperative period and on two consecutive days. Pulse duration and
current intensity were 200 µs and 15 mA, respectively. The length of each
TENS session was 60 minutes. Microscopic analyses were taken to
quantify the blood vessels and myofibroblasts on postoperative days 3, 7,
and 14. Results: On postoperative day 3, the LG showed more
angiogenesis than HG; on the postoperative days 7 and 14, the LG inhibited
the angiogenesis compared to SG. On postoperative day 3, the HG
inhibited the myofibroblasts compared to LG and SG, and on the
postoperative day 7 compared to SG only. Conclusions: Low-frequency
TENS increased the angiogenesis on postoperative day 3 and the highfrequency
TENS inhibited the angiogenesis and myofibroblasts of acute
excisional wounds in rats’ skin. / BV UNIFESP: Teses e dissertações
|
88 |
Efeitos da estimulação elétrica de baixa intensidade sobre o metabolismo ósseo de ratas ovarectomizadas / Effects of low intensity electrical stimulation on bone metabolism of ovariectomized ratsLirani-Galvão, Ana Paula Rebucci [UNIFESP] January 2008 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:47:37Z (GMT). No. of bitstreams: 0
Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estimulação elétrica de baixa intensidade (EE) tem sido utilizada para o reparo
ósseo, mas pouco se sabe sobre seus efeitos no tecido ósseo após a
menopausa. Os osteócitos provavelmente desempenham um importante papel
mediando este estímulo físico, e poderiam agir como transdutores através da
liberação de sinais bioquímicos como o óxido nítrico (NO). O objetivo deste
trabalho foi investigar os efeitos da EE no metabolismo ósseo de ratas
ovarectomizadas, e se o NO poderia ser um mediador destes efeitos. Sessenta
ratas (200-220g) foram divididas em 6 grupos: SHAM; SHAM tratado com 6mg/d
de L-NAME, um inibidor da NO sintase (SHAM-L-NAME); ovarectomizado (OVX);
OVX tratado com L-NAME (OVX-L-NAME) ou submetido a uma estimulação
elétrica no corpo todo do animal (OVX-EE) ou ambos (OVX-EE-L-NAME) por 12
semanas. A densidade mineral óssea (DMO) global, de coluna e membro
posterior foram medidas através de densitometria óssea antes e ao final do
protocolo. Após o sacrifício, as tíbias foram retiradas para análises
histomorfométricas e imunohistoquímicas. A apoptose de osteócitos (técnicas de
caspase-3 e TUNEL) e expressões da NO sintase endotelial (eNOS) e indutível
(iNOS) foram analisadas por imunohistoquímica. As ratas OVX demonstraram
significante (p<0.05 vs SHAM) diminuição da DMO final global, de coluna e de
membro posterior, medidas por densitometria, redução de volume ósseo (10% vs
25%) e número de trabéculas (1.7 vs 3.9), e aumento das superfícies de
reabsorção (4.7% vs 3.2%) e mineralização (15.9% vs 7.7%), medidas por
histomorfometria. No entanto, após a EE, todos estes parâmetros foram
semelhantes aos valores do grupo SHAM e significantemente diferentes de OVX.
A EE não foi capaz de prevenir a redução de volume ósseo e número de trabéculas causadas pela OVX na presença de L-NAME (OVX-L-NAME vs OVXEE-L-NAME),
como o fez na ausência deste inibidor da NOS. Porém, o L-NAME
não bloqueou os efeitos da EE na reabsorção óssea (superfícies de reabsorção e
de osteoclastos) em ratas OVX. A eNOS e iNOS foram: expressas de forma
semelhante no córtex das tíbias de SHAM, não expressas em OVX, e
similarmente expressas em OVX-EE quando comparadas ao SHAM. As
expressões de eNOS e iNOS não foram detectadas no tecido ósseo de nenhum
grupo tratado com L-NAME. Nas ratas OVX, a porcentagem de osteócitos
apoptóticos (24%) foi significantemente maior do que em SHAM (11%) e OVX-EE
(8%). Todos os grupos tratados com L-NAME tiveram uma diminuição na
porcentagem de osteócitos apoptóticos. Assim, nosso estudo evidenciou que a
EE previne alguns efeitos causados pela OVX no tecido ósseo preservando a
DMO, estrutura e microarquitetura ósseas, expressão de eNOS e iNOS e
viabilidade de osteócitos. Além disso, foi demonstrado que o L-NAME bloqueia
parcialmente os efeitos da EE na estrutura óssea (mas não na reabsorção) e na
expressão de eNOS e iNOS em ratas OVX, sugerindo que o NO possa ser um
mediador dos efeitos positivos da EE no tecido ósseo. No entanto, não foi
possível identificar se os efeitos positivos da EE na viabilidade de osteócitos
foram mediados pelo NO, pois os efeitos do L-NAME nestas células foram
semelhantes àqueles causados pela EE. / Low Intensity Electrical Stimulation (LIES) has been used for bone repair but little
is known about its effects on bone after menopause. Osteocytes probably play a
role in mediating this physical stimulus and they could act as transducers through
the release of biochemical signals, such as nitric oxide (NO). The aim of the
present study was to investigate the effects of LIES on bone metabolism in
ovariectomized rats, and if NO could be a mediator of these effects. Sixty rats
(200-220g) were divided into 6 groups: SHAM; SHAM treated with 6mg/d of LNAME,
an inhibitor of NO synthase (SHAM-L-NAME); ovariectomized (OVX); OVX
treated with L-NAME (OVX-L-NAME) or subjected to a whole body electrical
stimulation (OVX-LIES) or both (OVX-LIES-L-NAME) for 12 weeks. Global, spine
and posterior limb bone mineral density (BMD) were measured by bone
densitometry before and at the end of protocol. After sacrifice, tibias were
collected for histomorphometric and immunohistochemistry analysis. Osteocyte
apoptosis (caspase-3 and TUNEL techniques) and expressions of endothelial NO
synthase (eNOS) and inducible NOS (iNOS) were assessed by immunostaining.
OVX rats showed significant (p<0.05 vs SHAM) decreased final global, spine and
limb BMDs, measured by densitometry, decreased bone volume (10% vs 25%)
and trabecular number (1.7 vs 3.9), and increased eroded surfaces (4.7% vs
3.2%) and mineralization surfaces (15.9% vs 7.7%), measured by
histomorphometry. In contrast, after LIES, all these parameters tended to be
similar to SHAM and significantly different from OVX. LIES was not able to prevent
the reduction of bone volume and trabecular number caused by OVX in the
presence of L-NAME (OVX-L-NAME vs OVX-LIES-L-NAME), as it did in the
absence of this NOS inhibitor. However, L-NAME did not block the effects of LIES on bone resorption (eroded surface and osteoclasts surface) in OVX rats. eNOS
and iNOS were: similarly expressed in tibiae cortices of SHAM, not expressed in
OVX and correspondingly expressed in OVX+LIES when compared to SHAM.
eNOS and iNOS expressions were not detected on bone of none of L-NAME
treated groups. In OVX, the percentage of apoptotic osteocytes (24%) was
significantly increased when compared to SHAM (11%) and OVX-LIES (8%). All LNAME
treated groups showed a diminished percentage of apoptotic osteocytes. In
conclusion, our study showed that LIES counteracts some effects of OVX on bone
tissue preserving BMD, bone structure and microarchitecture, iNOS and eNOS
expression and osteocyte viability. Moreover, it was demonstrated that L-NAME
partially blocks the effects of LIES on bone structure (but not on bone resorption)
and on iNOS and eNOS expressions in OVX rats, suggesting that NO may be a
mediator of the positive effects of LIES on bone. However, it was not possible to
identify if the known positive effects of LIES on osteocyte viability were mediated
by NO, since the effects of L-NAME on these cells were similar to those caused by
LIES. / BV UNIFESP: Teses e dissertações
|
89 |
Novas evidências para doença pulmonar obstrutiva crônica : efeito do treinamento de força, muscular respiratório e da eletroestimulação neuromuscularVieira, Paulo José Cardoso January 2015 (has links)
Pacientes com doença pulmonar obstrutiva crônica (DPOC) apresentam uma função muscular alterada com prejuízo na capacidade de exercício. Na tentativa de reverter esse quadro, tem-se recomendado o uso de treinamento de força, de musculatura respiratória e mais recentemente da utilização de estimulação elétrica neuromuscular (EEN). No entanto, os estudos não demonstraram, o efeito sobre a hiperinsuflação dinâmica (HD) e qual a relação entre a presença do componente de fraqueza muscular respiratória e periférica na intolerância ao exercício. Métodos: Um programa de treinamento muscular respiratório (TMR, n = 51), treinamento de força (TF, n = 53) ou controle (n = 50), foi instituído. Função pulmonar, força muscular respiratória (PImax e PEmax), consumo de oxigênio (VO2pico), teste de caminhada de 6 minutos (TC6’), torque do músculo quadríceps (TMQ) e resistência (RMQ) foram avaliados. Em outro estudo com EEN (n = 11) e controles (n = 9). Foram avaliados, tolerância ao exercício (Tlim), função pulmonar, fator de necrose tumoral (TNF-α) e níveis de β-endorfina. Principais achados: O VEF1, CVF e VEF1/CVF aumentaram significativamente no TF. PImax (P <0,001) e TC6’ (P <0,01) aumentaram nos grupos TMR e TF. PEmax (P <0,001) foi maior no grupo TF vs. TMR. VO2pico (P <0,001) aumentou nos 2 grupos (TMR e TF) vs. controles. TMQ e RMQ (P <0,01) aumentou significativamente no grupo TF vs. TMR. O grupo EEN aumentou o VEF1, VEF1 /CVF, TC6’ e Tlim (P <0,01) e reduziu os valores na escala de Borg (P <0,01). Além disso, o Tlim foi positivamente correlacionado com melhorias no VEF1 (rho = 0,48; P <0,01), reduzindo os níveis de TNF-α e aumentando β-endorfina, em comparação com o grupo controle (P <0,001) Conclusão: O TMR e TF melhoram o desempenho do músculo esquelético periférico e respiratório em pacientes com DPOC. A EEN reduziu a dispnéia durante o exercício, acompanhado por melhorias no VEF1, tolerância ao exercício e HD.
|
90 |
Estimulação elétrica nervosa transcutânea na dor, função pulmonar e força muscular respiratória no pós-operatório de cirurgias torácicas em uma unidade de tratamento intensivo : ensaio clínico randomizadoHusch, Hermann Heinrich January 2017 (has links)
Objetivo: Avaliar os efeitos da estimulação elétrica nervosa transcutânea (TENS) comparada com TENS placebo e grupo controle sobre a dor, função pulmonar, força muscular respiratória e medicações analgésicas no pós-operatório de cirurgias torácicas em uma Unidade de Tratamento Intensivo (UTI). Método: Pacientes entre 31 e 76 anos submetidos a toracotomia póstero-lateral, foram incluídos e alocados aleatoriamente em três grupos: TENS (GE), TENS placebo (GP) e controle (GC). O GE recebeu a aplicação da TENS (frequência=100 Hz, duração de pulso=100 μs, intensidade no nível sensorial, durante 30 minutos, três vezes ao dia, durante a internação na UTI), associada a fisioterapia convencional (respiratória e motora). No GP foi realizada a TENS placebo além de fisioterapia convencional; e o GC recebeu apenas a fisioterapia convencional. Os desfechos foram avaliados no pré-operatório, pós-operatório (PO), e 48 horas após a internação na UTI: dor através da Escala Visual Analógica, função pulmonar através de espirometria (VEF1 e CVF), força muscular respiratória através de manovacuometria (PImáx e PEmáx), e medicações através da análise dos prontuários. Resultados: Foram incluídos 45 pacientes, sendo 15 em cada grupo. Em relação a percepção dolorosa, não houve diferença entre os grupos (P=0,172), porém houve redução na dor após o término do primeiro atendimento no GE (4,7±3,2 vs. 3,3±2,6; P<0,05). Em relação a função pulmonar e força respiratória não houve diferença significativa entres os grupos nos momentos avaliados. Entretanto, nas avaliações intragrupo, observou-se melhora na CVF, todos os grupos apresentaram redução no momento PO e 48 horas comparado com o pré (P<0,001), e somente o GE promoveu um aumento na CVF nas 48 horas em relação ao PO (P<0,001). A PImáx e PEmáx diminuíram em todos os grupos comparando o pré com o PO e 48 horas (P<0,001). Não houve diferença entre os grupos em relação as medicações analgésicas, porém o GC apresentou maior consumo de morfina (p=0,037) e o GP maior consumo de paracetamol (p=0,035) 24 vs 48 horas, o que não foi alterado no GE. Conclusão: Não foi observado diferença entre os grupos em relação aos desfechos avaliados no pós-operatório de cirurgia torácica, porém, a TENS 13 promoveu redução da dor e aumento mais precoce da CVF, além disso, não promoveu aumento no consumo de medicação. / Objective: To evaluate the effects of transcutaneous electrical nerve stimulation (TENS) compared to placebo TENS and control group on pain, pulmonary function, respiratory muscle strength and analgesic medications in the postoperative period of thoracic surgery in an Intensive Care Unit (ICU). Methods: Patients between 31 and 76 years submitted to postero-lateral thoracotomy, were included and randomly allocated into three groups: TENS (GE), TENS placebo (GP) and control (GC). The GE received TENS (frequency = 100 Hz, pulse duration = 100 μs, intensity at the sensory level for 30 minutes, three times a day during ICU stay), associated with conventional physiotherapy (respiratory and motor). In GP, TENS was performed in addition to conventional physiotherapy; And GC received only conventional physiotherapy. The outcomes were evaluated in the preoperative, postoperative (PO) or 24 hours, and 48 hours after ICU admission: Pain through Visual Analog Scale, pulmonary function through spirometry (FEV 1 and FVC), respiratory muscle strength Through manovacuometry (MIP and MEP), and medications through the analysis of medical records. Results: 45 patients were included, 15 in each group. Regarding pain perception, there was no difference between the groups (P = 0.172), but there was a reduction in pain after the end of the first treatment in the GE (4.7 ± 3.2 vs. 3.3 ± 2.6; P <0.05). Regarding pulmonary function and respiratory force, there was no significant difference between the groups at the moments evaluated. However, in the intragroup evaluations, improvement in FVC, all the groups had a reduction at the time PO and 48 hours compared to the pre (P <0.001), and only the GE promoted an increase in FVC at 48 hours in relation to PO (P <0.001). The MIP and MEP decreased in all groups comparing the pre with PO and 48 hours (P <0.001).There was no difference between the groups in relation to analgesic medications, however, the CG had higher morphine consumption (p = 0.037) and the GP had a higher paracetamol consumption (p = 0.035) 24 vs 48 hours, which was not altered in the GE. Conclusion: No differences were observed between the groups in relation to the outcomes evaluated in the postoperative period of thoracic surgery, however, TENS promoted pain reduction and earlier increase in FVC, in addition, did not promote increase in medication consumption.
|