• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do pH e da concentração de fluoreto presente em dentifrícios líquidos no controle de cárie em área fluoretada: estudo clínico randomizado / Effect of liquid dentifrices pH and fluoride concentration on caries control in a region with fluoridated water: randomized clinical trial

Cardoso, Cristiane de Almeida Baldini 14 June 2013 (has links)
Os dentifrícios de baixa concentração de fluoreto têm sido sugeridos como alternativa para reduzir o risco de fluorose dentária, embora não haja consenso quanto a sua eficácia clínica, a qual pode ser aumentada quando o pH é ácido. Este estudo clínico randomizado teve como objetivo avaliar o efeito anti-cárie do pH e da concentração de fluoreto presente em dentifrícios líquidos, em crianças com diferentes status de atividade cariosa. Crianças de 2-4 anos de idade residentes em uma área fluoretada (0,6-0,8 ppm F), com (A) e sem (I) lesões de cárie ativa foram distribuídas aleatoriamente em três grupos de acordo com o tipo de dentifrício utilizado: Grupo 1 (n=48-A/56-I): 550 ppm F pH 4,5, Grupo 2 (n=56-A/48-I) 1100 ppm F pH 7,0, Grupo 3 (n=52-A/55-I): 550 ppm F pH 7,0. O número de lesões tornando-se ativas/cavidades ou inativas, respectivamente, foi avaliado clinicamente após 12 meses, podendo-se determinar se as lesões progrediram ou regrediram. Além disso, as lesões de mancha branca foram avaliadas através da técnica de quantificação de fluorescência induzida por luz (Quantitative Light-Induced Fluorescence - QLF) em uma subamostra de 75 crianças. A concentração de fluoreto nas unhas dos pés e no biofilme dentário também foi avaliada após 6 meses de uso dos dentifrícios. A progressão de cárie seguiu um padrão decrescente de acordo com o dentifrício utilizado (G3>G2>G1), independentemente da atividade de cárie da criança, mas diferenças significativas foram detectadas apenas para a progressão e o incremento de cárie (G1 < G3) no grupo de crianças cárie-ativas, quando avaliadas por inspeção visual. Para a regressão de cárie, os valores encontrados para os 3 grupos foram mais parecidos entre si, não havendo diferenças significativas entre osgrupos. Por outro lado, a análise com o QLF não detectou diferença significativa entre os Grupos 1 e 2, mas eles tiveram um desempenho significativamente melhor que o Grupo 3. Concentrações de fluoreto nas unhas significativamente mais baixas foram observadas quando as crianças usaram os dentifrícios fluoretados de baixa concentração de F, independente do pH. A concentração de F no biofilme foi significativamente maior para o grupo 2 quando comparado ao grupo 3 independente do tempo de coleta, enquanto o grupo 1 não diferiu significativamente do grupo 2, mas foi significativamente maior que o grupo 3, 60 minutos após a coleta. Os resultados reforçam os dados anteriores que mostraram um bom potencial do dentifrício líquido ácido de baixa concentração de F para prevenir lesões cariosas e ao mesmo tempo reduzir a ingestão de fluoreto. Assim, este dentifrício parece ser uma boa opção para as crianças na idade de risco para fluorose dentária, residentes em uma região fluoretada, independente da atividade de cárie. / Low-F dentifrices have been suggested as an alternative to reduce the risk of dental fluorosis, although there is no consensus on their clinical efficacy, which may be increased when the pH is acidic.The present randomized clinical trial evaluated the anticaries effect of low-F acidic liquid dentifrice in children at different caries activity status. Two-to-four-year-old schoolchildren living in a fluoridated area (0.6 0.8 ppm F), with (A) or without (I) active caries lesions were randomly allocated into 3 groups differing according to the type of dentifrice used over 12 months: Group 1 (n=48-A/56-I): 550 ppm F pH 4.5, Group 2 (n=56-A/48-I) 1100 ppm F pH 7.0, Group 3 (n=52-A/55-I): 550 ppm F pH 7.0. The number of lesions becoming active/cavities or inactive was clinically evaluated determining progression or regression. Additionally, the white spot lesions were evaluated by the quantitative light-induced fluorescence (QLF) method in a subsample of 75 children. Toenail and plaque fluoride concentration were also evaluated 6 months after the use of the dentifrices. Plaque samples were collected 5 and 60 minutes after the last use of the dentifrices. Caries net increment followed a decreasing pattern according to the dentifrice used (G3>G2>G1) regardless caries activity, but significant differences were detected only for caries progression and net increment (G1 < G3) for the cariesactive group when evaluated through visual inspection. For the regression, the values found for the three groups were more similar, without significant differences. QLF analysis detected no significant difference between Groups 1 and 2, but they performed significantly better than Group 3. Toenail fluoride concentration significantly lower was observed when children used the low-fluoride dentifrices. Plaque F concentration was significantly higher for Group 2 compared to group 3, egardless the time, while Group 1 did not significantly differ Group 2, but was significantly higher when compared to Group 3, 60 minutes after plaque collection. The results reinforce previous data that showed a good potential of the low-fluoride acidic LD to prevent caries and reduce fluoride intake. Thus, it seems to be a good option for children at the age of risk for dental fluorosis, living in a fluoridated area, regardless the risk for dental caries.
2

Estudo clínico randomizado e duplo-cego do Biosilicato sob restaurações de resina composta em dentes afetados por cárie / Double-blind, randomized clinical trial of Biosilicate under resin composite restorations in caries affected teeth

Palomino, Karen Pintado 22 June 2017 (has links)
O presente estudo teve por objetivo avaliar o efeito de um biomaterial vitrocerâmico (Biosilicato®) no desempenho clínico de restaurações posteriores em resina composta. 92 cavidades Classe I e Classe II com lesão de cárie (no terço meio da dentina) foram selecionadas e distribuídas aleatoriamente em quatro grupos segundo o protocolo adesivo: 1- Biosilicato / sistema adesivo convencional de dois passos, 2- Controle / sistema adesivo convencional de dois passos, 3- Biosilicato / sistema adesivo autocondicionante de dois passos e 4- Controle / sistema adesivo autocondicionante de dois passos. Dois operadores realizaram os protocolos adesivos e restauraram as cavidades com uma resina composta nanohíbrida (IPS Empress, Ivoclar) usando a técnica incremental. Os participantes foram remarcados após uma semana, 6, 12 e 18 meses para avaliação clínica realizada por dois examinadores, cegados e calibrados de acordo com os critérios FDI. Os dados foram analisados com o teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Os resultados revelaram que não houve diferença estatisticamente significante (p > 0.05) entre os grupos experimentais e os respectivos controles em nenhuma avaliação, entretanto, houve diferença estatisticamente significativa (p < 0.05) entre os grupos controles (2 x 4) para o critério forma anatômica (1 semana) e adaptação marginal (18 meses). O grupo 2 foi estatisticamente diferente do grupo 3 (p < 0.05), para o critério fratura do material/retenção (18 meses) e adaptação marginal (1 semana), onde o grupo 2 apresentou melhor desempenho. O uso do Biosilicato no protocolo restaurador de dentina afetada por cárie não alterou o desempenho clinico de restaurações em resina composta no período de 18 meses de acompanhamento. A associação entre o sistema adesivo autocondicionante de dois passos e o Biosilicato gerou desempenho clínico inferior, comparado ao sistema adesivo convencional (controle), em termos de adaptação marginal e fratura do material/retenção. / The aim of this study was to evaluate the effect of a bioactive glass-ceramic (Biosilicate®) on clinical performance of posterior resin composite restorations. A total of 92 restorations in Class I and Class II cavities with carious lesion (medium third of dentin) were selected and assigned randomly into four groups according to the adhesive protocol used: 1- Biosilicate / Two-step etch and rinse system, 2- Control / Two-step etch and rinse system, 3- Biosilicate / Two-step self-etching system and 4- Control / Two-step self-etching system). Two operators carried out the adhesive protocols and restored the cavities with a nano-hybrid resin composite (IPS Empress, Ivoclar) using the incremental technique. Participants were recalled at one week, 6, 12 and 18 months for clinical evaluation performed by two blinded examiners and calibrated according to FDI criteria. Data were analyzed using Krusall-Wallis non-parametric test and multiple comparison Dunn test with a significance level of 5%. Results showed no statistical difference (p > 0.05) between the experimental groups and their respective controls; however, there were statistical difference between control groups (2 x 4) (p < 0.05) for anatomical form (1 week) and marginal adaptation (18 months). Group 2 was statistically different from Group 3 (p < 0.05), for fracture of material/retention (18 months) and marginal adaptation category (1 week), where Group 2 showed the better performance. The use of Biosilicate, in a restorative protocol for caries-affected dentin, did not alter the clinical performance of posterior resin composite restorations. The association between Biosilicate and two-step self-etching adhesive system showed an inferior clinical performance, compared to the conventional adhesive system (control), in terms of marginal adaptation and fracture of material/retention.
3

Desenvolvimento de uma técnica de desenho digital e impressão em 3D de placas oclusais e sua aplicabilidade no tratamento de pacientes com disfunção temporomandibular / Development of a technique of digital design and 3D printing of occlusal splints and its applicability in the treatment of patients with temporomandibular disorders

Vasques, Mayra Torres 11 December 2018 (has links)
O uso de novas tecnologias na odontologia, como a técnica CAD/CAM, promete ser uma opção relevante no que diz respeito à confecção das placas oclusais, empregadas no tratamento de disfunções temporomandibulares. O objetivo desta pesquisa foi desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e verificar seus resultados clínicos no tratamento de pacientes com disfunções temporomandibulares. Para o desenho das placas foi desenvolvida uma metodologia de desenho digital (CAD), utilizando o software Meshmixer® (Autodesk, USA), e de registro das relações maxilo-mandibulares. A partir dessa metodologia iniciou-se um estudo clínico randomizado comparativo entre as placas CAD/CAM produzidas em impressora 3D e placas produzidas convencionalmente em laboratório. O estudo foi realizado em duas etapas, 18 pacientes foram avaliados de acordo com os critérios de inclusão e exclusão. Na Etapa 1 (n=18) foram realizados testes técnicos comparativos das duas placas em relação à dor, por meio da Escala Visual Analógica; atividade muscular; ajuste interno; báscula; conforto; tempo de instalação; pontos de contato oclusal. Todos os pacientes da amostra utilizaram os dois tipos de placas. Na Etapa 2, estes pacientes foram divididos randomicamente em dois grupos para o estudo clínico randomizado (estudo cego): Grupo IMP (n=9) (placas impressas) e grupo LAB (n=9) (placas convencionais laboratoriais). Os grupos foram avaliados após 1 mês de uso, por meio dos Questionários, RDC/TMD, SF-36, escala visual de dor EVA, e pelos pontos de contato oclusais. Os dados foram avaliados estatisticamente usando os testes de Wilcoxon, de Mann-Whitney, e de Kruskal-Wallis nas análises quantitativas; os testes Qui-Quadrado e Exato de Fisher, nas variáveis categóricas. Os resultados mostraram que houve diferenças significativas (P-valor<0.05) nas avaliações para conforto, ajuste interno e tempo de confecção das placas, a favor das placas impressas. Nas demais avaliações, os grupos foram equivalentes (não- significantes). Concluiu-se que foi possível desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e que o desempenho clínico foi equivalente entre as placas convencionais e impressas, sendo que estas se mostraram superiores quanto ao conforto e quanto à adaptação da superfície interna da placa, mostrando ser este um método possível e viável economicamente. / The use of new technologies in dentistry, as the CAD/CAM technique, promises to be a relevant option concerning the manufacture of occlusal splints for temporomandibular disorders treatment. The aim of this research was to develop a technique for design and manufacture occlusal splints using the CAD/CAM method and 3D printer and verify the clinical results in the treatment of temporomandibular disorders patients. It was developed a technique for occlusal splint design a using the software Meshmixer® (Autodesk, USA) and a technique to register the jaws relationship. From this method, it was started a Randomized Clinical Trial (RCT) to compare splints made through the CAD/CAM technique and others made conventionally in a dental lab. The study was performed in two steps, 18 patients were selected based on the inclusion/exclusion criteria. In Step 1 (n=18) patients were comparatively evaluated, using both splints, in relation to pain, using the visual analog scale; internal adjustment of the splint; patients comfort; time spent to deliver the appliance and occlusal contacts pattern. In Step 2, these patients were allocated in two groups (n=9 each group) randomly to the RCT be performed (blind study): Group IMP - printed splints and Group LAB (conventional lab splints). Both groups were assessed after 1 month using the splint using RDC/TMD and SF-36 questionnaires, the visual analog scale for pain, and occlusal contacts pattern. The data were statistically evaluated using Wilcoxon, Mann-Whitney, and Kruskal-Wallis test for qualitative analyses and Qui-square and Fisher´s exact tests for categorical variables. The results showed significant statistical differences (p-value<0.05) in favor of printed occlusal splints, related to patients\' comfort, internal adjustment, and time spent to deliver the appliance. All other assessments were equivalents (not significant). It was concluded that it was possible to develop a technique to design and manufacture occlusal splints using CAD/CAM and 3D printer, and furthermore the clinical performance was equivalent comparing conventional and printed occlusal splints, being the printed splints superior to conventional splints in relation to comfort and internal adjustment, proving this is a possible and economically viable method.
4

Efeito do pH e da concentração de fluoreto presente em dentifrícios líquidos no controle de cárie em área fluoretada: estudo clínico randomizado / Effect of liquid dentifrices pH and fluoride concentration on caries control in a region with fluoridated water: randomized clinical trial

Cristiane de Almeida Baldini Cardoso 14 June 2013 (has links)
Os dentifrícios de baixa concentração de fluoreto têm sido sugeridos como alternativa para reduzir o risco de fluorose dentária, embora não haja consenso quanto a sua eficácia clínica, a qual pode ser aumentada quando o pH é ácido. Este estudo clínico randomizado teve como objetivo avaliar o efeito anti-cárie do pH e da concentração de fluoreto presente em dentifrícios líquidos, em crianças com diferentes status de atividade cariosa. Crianças de 2-4 anos de idade residentes em uma área fluoretada (0,6-0,8 ppm F), com (A) e sem (I) lesões de cárie ativa foram distribuídas aleatoriamente em três grupos de acordo com o tipo de dentifrício utilizado: Grupo 1 (n=48-A/56-I): 550 ppm F pH 4,5, Grupo 2 (n=56-A/48-I) 1100 ppm F pH 7,0, Grupo 3 (n=52-A/55-I): 550 ppm F pH 7,0. O número de lesões tornando-se ativas/cavidades ou inativas, respectivamente, foi avaliado clinicamente após 12 meses, podendo-se determinar se as lesões progrediram ou regrediram. Além disso, as lesões de mancha branca foram avaliadas através da técnica de quantificação de fluorescência induzida por luz (Quantitative Light-Induced Fluorescence - QLF) em uma subamostra de 75 crianças. A concentração de fluoreto nas unhas dos pés e no biofilme dentário também foi avaliada após 6 meses de uso dos dentifrícios. A progressão de cárie seguiu um padrão decrescente de acordo com o dentifrício utilizado (G3>G2>G1), independentemente da atividade de cárie da criança, mas diferenças significativas foram detectadas apenas para a progressão e o incremento de cárie (G1 < G3) no grupo de crianças cárie-ativas, quando avaliadas por inspeção visual. Para a regressão de cárie, os valores encontrados para os 3 grupos foram mais parecidos entre si, não havendo diferenças significativas entre osgrupos. Por outro lado, a análise com o QLF não detectou diferença significativa entre os Grupos 1 e 2, mas eles tiveram um desempenho significativamente melhor que o Grupo 3. Concentrações de fluoreto nas unhas significativamente mais baixas foram observadas quando as crianças usaram os dentifrícios fluoretados de baixa concentração de F, independente do pH. A concentração de F no biofilme foi significativamente maior para o grupo 2 quando comparado ao grupo 3 independente do tempo de coleta, enquanto o grupo 1 não diferiu significativamente do grupo 2, mas foi significativamente maior que o grupo 3, 60 minutos após a coleta. Os resultados reforçam os dados anteriores que mostraram um bom potencial do dentifrício líquido ácido de baixa concentração de F para prevenir lesões cariosas e ao mesmo tempo reduzir a ingestão de fluoreto. Assim, este dentifrício parece ser uma boa opção para as crianças na idade de risco para fluorose dentária, residentes em uma região fluoretada, independente da atividade de cárie. / Low-F dentifrices have been suggested as an alternative to reduce the risk of dental fluorosis, although there is no consensus on their clinical efficacy, which may be increased when the pH is acidic.The present randomized clinical trial evaluated the anticaries effect of low-F acidic liquid dentifrice in children at different caries activity status. Two-to-four-year-old schoolchildren living in a fluoridated area (0.6 0.8 ppm F), with (A) or without (I) active caries lesions were randomly allocated into 3 groups differing according to the type of dentifrice used over 12 months: Group 1 (n=48-A/56-I): 550 ppm F pH 4.5, Group 2 (n=56-A/48-I) 1100 ppm F pH 7.0, Group 3 (n=52-A/55-I): 550 ppm F pH 7.0. The number of lesions becoming active/cavities or inactive was clinically evaluated determining progression or regression. Additionally, the white spot lesions were evaluated by the quantitative light-induced fluorescence (QLF) method in a subsample of 75 children. Toenail and plaque fluoride concentration were also evaluated 6 months after the use of the dentifrices. Plaque samples were collected 5 and 60 minutes after the last use of the dentifrices. Caries net increment followed a decreasing pattern according to the dentifrice used (G3>G2>G1) regardless caries activity, but significant differences were detected only for caries progression and net increment (G1 < G3) for the cariesactive group when evaluated through visual inspection. For the regression, the values found for the three groups were more similar, without significant differences. QLF analysis detected no significant difference between Groups 1 and 2, but they performed significantly better than Group 3. Toenail fluoride concentration significantly lower was observed when children used the low-fluoride dentifrices. Plaque F concentration was significantly higher for Group 2 compared to group 3, egardless the time, while Group 1 did not significantly differ Group 2, but was significantly higher when compared to Group 3, 60 minutes after plaque collection. The results reinforce previous data that showed a good potential of the low-fluoride acidic LD to prevent caries and reduce fluoride intake. Thus, it seems to be a good option for children at the age of risk for dental fluorosis, living in a fluoridated area, regardless the risk for dental caries.
5

Estudo clínico randomizado e duplo-cego do Biosilicato sob restaurações de resina composta em dentes afetados por cárie / Double-blind, randomized clinical trial of Biosilicate under resin composite restorations in caries affected teeth

Karen Pintado Palomino 22 June 2017 (has links)
O presente estudo teve por objetivo avaliar o efeito de um biomaterial vitrocerâmico (Biosilicato®) no desempenho clínico de restaurações posteriores em resina composta. 92 cavidades Classe I e Classe II com lesão de cárie (no terço meio da dentina) foram selecionadas e distribuídas aleatoriamente em quatro grupos segundo o protocolo adesivo: 1- Biosilicato / sistema adesivo convencional de dois passos, 2- Controle / sistema adesivo convencional de dois passos, 3- Biosilicato / sistema adesivo autocondicionante de dois passos e 4- Controle / sistema adesivo autocondicionante de dois passos. Dois operadores realizaram os protocolos adesivos e restauraram as cavidades com uma resina composta nanohíbrida (IPS Empress, Ivoclar) usando a técnica incremental. Os participantes foram remarcados após uma semana, 6, 12 e 18 meses para avaliação clínica realizada por dois examinadores, cegados e calibrados de acordo com os critérios FDI. Os dados foram analisados com o teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Os resultados revelaram que não houve diferença estatisticamente significante (p > 0.05) entre os grupos experimentais e os respectivos controles em nenhuma avaliação, entretanto, houve diferença estatisticamente significativa (p < 0.05) entre os grupos controles (2 x 4) para o critério forma anatômica (1 semana) e adaptação marginal (18 meses). O grupo 2 foi estatisticamente diferente do grupo 3 (p < 0.05), para o critério fratura do material/retenção (18 meses) e adaptação marginal (1 semana), onde o grupo 2 apresentou melhor desempenho. O uso do Biosilicato no protocolo restaurador de dentina afetada por cárie não alterou o desempenho clinico de restaurações em resina composta no período de 18 meses de acompanhamento. A associação entre o sistema adesivo autocondicionante de dois passos e o Biosilicato gerou desempenho clínico inferior, comparado ao sistema adesivo convencional (controle), em termos de adaptação marginal e fratura do material/retenção. / The aim of this study was to evaluate the effect of a bioactive glass-ceramic (Biosilicate®) on clinical performance of posterior resin composite restorations. A total of 92 restorations in Class I and Class II cavities with carious lesion (medium third of dentin) were selected and assigned randomly into four groups according to the adhesive protocol used: 1- Biosilicate / Two-step etch and rinse system, 2- Control / Two-step etch and rinse system, 3- Biosilicate / Two-step self-etching system and 4- Control / Two-step self-etching system). Two operators carried out the adhesive protocols and restored the cavities with a nano-hybrid resin composite (IPS Empress, Ivoclar) using the incremental technique. Participants were recalled at one week, 6, 12 and 18 months for clinical evaluation performed by two blinded examiners and calibrated according to FDI criteria. Data were analyzed using Krusall-Wallis non-parametric test and multiple comparison Dunn test with a significance level of 5%. Results showed no statistical difference (p > 0.05) between the experimental groups and their respective controls; however, there were statistical difference between control groups (2 x 4) (p < 0.05) for anatomical form (1 week) and marginal adaptation (18 months). Group 2 was statistically different from Group 3 (p < 0.05), for fracture of material/retention (18 months) and marginal adaptation category (1 week), where Group 2 showed the better performance. The use of Biosilicate, in a restorative protocol for caries-affected dentin, did not alter the clinical performance of posterior resin composite restorations. The association between Biosilicate and two-step self-etching adhesive system showed an inferior clinical performance, compared to the conventional adhesive system (control), in terms of marginal adaptation and fracture of material/retention.
6

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Crevelari, Elizabeth Sartori 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
7

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Elizabeth Sartori Crevelari 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences

Page generated in 0.1055 seconds