• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 44
  • 44
  • 31
  • 29
  • 13
  • 12
  • 12
  • 12
  • 11
  • 11
  • 9
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Modelagem e implantação de sistema de informações para monitorar custo de produção dos produtos fabricados pela Farmácia Hospitalar do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo / Modeling and implantation information system to monitor the production costs of manufactured products by the hospital pharmacy of Hospital das Clínicas, Faculty of Medicine, University of Sao Paulo

Marin, Marcia Lucia de Mario 08 October 2004 (has links)
A partir do método de custeio por absorção, com adaptação do custeio baseado em atividades, um sistema de informações foi modelado e implantado para monitorar custo de produção, dos produtos fabricados pela farmácia hospitalar do Hospital das Clínicas da Faculdade de Medicina da USP. Foram analisados os formulários dos produtos fabricados, insumos, gastos indiretos de fabricação, controle de qualidade e totalizados os tempos gastos da mão-de-obra direta de 100 produtos fabricados em julho de 2003. Os resultados mostraram que de 35 itens produzidos com similares, 28 apresentaram custo de produção inferior ao preço do fabricante no mercado, estimando que nesse mês o HC deixou de gastar, aproximadamente, 750 mil reais com a produção interna. Os 65 itens restantes eram produtos exclusivos e especiais. Os gastos com insumos corresponderam a 69% do custo total de produção. O modelo proposto mostrou que a farmácia hospitalar pode proporcionar redução de gastos à entidade. / On the basis of the absorption costing method, with a number of adaptations from activity based costing, an information system was modeled and implanted to monitor the production costs of products manufactured by the hospital pharmacy of Hospital das Clínicas, Faculty of Medicine, University of São Paulo. Were analysed manufactured products forms, raw material, indirect manufacturing costs, quality control, and added up direct labor time for 100 manufactured products in July 2003. The results showed that out of 35 items produced with similar products in the market, 28 presented a production cost below the price of the market manufacturer. Evaluations revealed that, during this month, the institution saved about 750 thousand reais through internal production. The 65 remaining items were exclusive and special products. Raw material expenses accounted for 69% of total production costs. The proposed model showed that the hospital pharmacy can lead to expense reduction for the entity.
32

Influência da reutilização na biocompatibilidade de materiais médico-hospitalares de uso único / Influence reuse in the biocompatibility of hospital medical materials for single use

silva, Monica Valero da 27 February 2002 (has links)
A prática da reutilização de produtos médico-hospitalares de uso único vem sendo aplicada desde meados da década de setenta. A principal razão que tem contribuído para disseminação desta conduta pelas instituições hospitalares radicadas tanto nos países em desenvolvimento como naqueles considerados ricos, tem sido a aparente economia de custos. Apesar dos riscos relacionados com a prática da reutilização, como reações pirogênicas, danos ocasionados por bactérias consideradas patogênicas em pacientes imunologicamente comprometidos, danos na integridade fisica dos produtos, assim como aumento do período de permanência dos pacientes no hospital, têm despertado o interesse em avaliar aspectos fisicos e biológicos dos produtos médico-hospitalares reutilizados. Baseando-se nestas considerações foram aplicados desafios com esporos de Bacillus Subtilis varo niger ATCC 9372 e endotoxina bacteriana E. coli 055:B5. Os produtos desafiados foram cateteres intravenosos, torneira três vias e tubos de traqueostomia. A possível presença microbiana foi investigada após contaminação intencional dos esporos de B. Subtillis (107 ufc/unid.) com submissão das unidades contaminadas à limpeza e posterior esterilização, utilizando óxido de etileno/CFC na proporção 12:88. Os ciclos de reprocessamentos simulados de produtos médico-hospitalares consistiram de contaminação de cada unidade teste com carga microbiana, lavagem com detergente enzimático, secagem e esterilização. Ao término de cada ciclo de reprocessamento foram separadas unidades representativas para avaliação por contagem microbiana (pour plate), testes de esterilidade por inoculação direta e indireta, citotoxidade por cultura de células e microscopia eletrônica de varredura. A eficiência da esterilidade foi avaliada tanto por contagem microbiana como pelos testes de esterilidade, que resultaram em níveis microbianos de 103 ufc/unid. e detecção de contaminação até o 6° ciclo de reprocessamento nos cateteres intravenosos, tubos de traqueostomia e torneiras três vias. A segurança dos reprocessamentos dos produtos médico-hospitalares foi avaliada pela cultura de células de fibroblastos de camundongo (NCTC clone 929), as quais não apresentaram toxicidade. Entretanto, os resultados obtidos durante microscopia eletrônica de varredura comprovaram presença de carga microbiana após 10° ciclo de reprocessamento, assim como danos na superficie polimérica. Durante desafio com endotoxina bacteriana, que consistiu em contaminar as unidades com 200 UE, secagem e exposição ao ciclo de esterilização com óxido de etileno/CFC (12:88), verificou-se que após ciclos de reprocessamentos simulados, totalizando dez ciclos, foi possível detectar valores de recuperação de endotoxina em torno de 100%. Os cateteres-guia que foram adquiridos em instituição hospitalar após quatro reutilizações, apresentaram níveis de contaminação de 105 ufc/unid., assim como presença de bactérias consideradas patogênicas em pacientes comprometidos imunologicamente, já a detecção de endotoxina bacteriana nestes cateteres não foi considerada significativa. Logo, as avaliações aplicadas nas unidades submetidas aos ciclos de reprocessamentos simulados, assim como nos cateteres-guia reprocessados e reutilizados quatro vezes, refletiram a realidade de algumas instituições no âmbito nacional e internacional que praticam a reutilização de produtos médico-hospitalares de uso-único. Os resultados obtidos vêm enfatizar objeções quanto à prática da reutilização, considerando que a ausência de segurança pode ocasionar em danos ao paciente. / The practices of reutilization of single use hospital medical devices came into practice since mid seventies. The main reason that has contributed for dissemination of this practice by institutional hospitals in underdeveloped as well as those considered as rich countries has been the appellant economy of costs. Despite well known risks related with the practice of reutilization, such as pyrogenic reactions, damages caused by bacteria\'s considered pathogenic in patients immunologically compromised, damages to the physical integrity of the materials, as well as prolonged permanence of the patient in the hospital, has raised interests in the evaluation of physical and biological aspects of the reused medical device. Based on these considerations, challenges had been applied with spores of Bacillus Subtilis varo niger 9372 ATCC and bacterial endotoxin E. coli 055:B5. The selected materials includes, intravenous catheters, three-way stopcocks and traqueostomy tubes. The possible presence of bacteria was investigated after intentional contamination with spores of B. Subtillis (107 cfu/unit) followed by submission of the inoculated units to the cleaning process and posterior sterilization using ethylene oxide at 12:88. The simulated reprocessing cycles of the medical device had consisted of contamination of each test unit with predetermined microbial load, washing with enzymatic detergent, drying and sterilization. At the end of each reprocessing cycle, representative sarnples had been segregated to evaluate microbial count (pour plate), terility test through direct and indirect inoculation, cytotoxicity test through cell culture and scanning electron microscopy. The efficiency of the sterility was evaluated through microbial count, as for the sterility tests, that had resulted in microbial count of 103 cfu/unit and detection of contamination until the 6th cycle of reprocessing in the intravenous catheters, three-way stopcocks and traqueostomy tubes. The safety of these reprocessed medical devices was evaluated by mouse fibroblasts cell culture (NCTC clone 929), which didn\'t presented significant toxicity. However, the results obtained by scanning electron microscopy proved the presence of microbial load after 10th reprocessing cycle, as well as damages to the polymeric surface. During challenge with bacterial endotoxin, that consisted of contaminating the units with 200 EU, drying and submission to sterilization cycles with ethylene oxide/cfe (12:88), it was verified that after ten simulated reprocessing cycles, it was possible to recover around 100% of endotoxin. The catheter guide that were acquired from institutional hospital after four times reuse, had presented levels of contamination of 105 cfu/unit, as well as presenee of bacteria considered pathogenic in patients immunologically compromised, on the other hand the detention of bacterial endotoxin in these catheters was not considered significant. The evaluations studies condueted with the units submitted to the simulated reprocessing cycles, as well as the catheter guide reprocessed and reused four times, had reflected the reality of some national and foreign hospitais which reutilize single use medical device. The results obtained lead us to raise objections to the reusing practice, considering the absence of adequate patients safety.
33

MODELO DE APOIO À DECISÃO QUALITATIVA PARA IMPLANTAÇÃO DE FARMÁCIAS EM HOSPITAIS UNIVERSITÁRIOS / MODEL OF SUPPORT FOR IMPLEMENTATION OF DECISION QUALITATIVE UNIVERSITY HOSPITALS IN PHARMACIES

Pereira, Carlos Roberto Cessel 14 May 2008 (has links)
Made available in DSpace on 2016-08-10T10:29:28Z (GMT). No. of bitstreams: 1 CARLOS ROBERTO CESSEL PEREIRA.pdf: 842792 bytes, checksum: 96c8aac58118444975fd00fb76640143 (MD5) Previous issue date: 2008-05-14 / The scenario of this work are the University Hospitals, maintained by the Ministries of Education and Health, and the object is the planned deployment of the environment of hospital pharmacy. The practice of contracting Brazilian eases the management of government resources in University Hospitals (HU's) and exits of managing the financial goals and objectives and be based on decisions by quality and physical targets. The HU's institutions are to support education in the health field, and are belonging to the Federal Universities, have not for profit, which prevents analysis of the financial management of the "return on investment." This paper proposes to review the alternative service in HU's pharmacy, taking into account the assumption the evaluation of performance of hospitals from contracting, focusing on the decision by qualitative analysis. The tool, among others studied, chosen for the qualitative assessment is the model for decisionmaking with multiple criteria called Analytic Hierarchy Process (AHP), therefore, involves the decision multivariate multipessoal and observation. It is proposed to bring the AHP to the environment of technological product, considering the hospital pharmacy as a tool, a technological product to be used, where to fit the criteria of quality proposes to use the standard NBR ISO / IEC 9126 -- 1:2003. A scenario of real HU is used to display the real application of the method, and its results are a validation of the method AHP to the process, the reliability and efficiency criteria being determined as the most important in choosing alternative and produce the drugs in HU itself, with all the necessary biosafety has been chosen. / O cenário deste trabalho são os Hospitais Universitários, mantidos pelos Ministérios da Educação e da Saúde, e, o objeto é a implantação planejada do ambiente de farmácia hospitalar. A prática brasileira de contratualização flexibiliza a gestão de recursos governamentais em Hospitais Universitários (HU s) e permite sair da gestão orientada aos objetivos e metas financeiras e apoiar-se em decisões por qualidade e metas físicas. Os HU s são instituições de apoio ao ensino da área da saúde, e, são pertencentes às Universidades Federais, não possuem fins lucrativos, o que impede análises financeiras da gestão do tipo retorno sobre o investimento . Neste trabalho propõe-se avaliar alternativas do serviço de farmácia em HU s, levando em conta o pressuposto a avaliação de desempenho dos hospitais a partir da contratualização, focando na decisão por análise qualitativa. A ferramenta, dentre outras estudadas, escolhida para a avaliação qualitativa é o modelo para tomada de decisão com múltiplos critérios denominados Analytic Hierarchy Process (AHP), pois, envolve a decisão multivariada e a observação multipessoal. Propõe-se adequar o AHP ao ambiente do produto tecnológico, por considerar a farmácia hospitalar, enquanto ferramenta, um produto tecnológico a ser utilizado, sendo que, para a adequação dos critérios de qualidade propõe-se utilizar a norma NBR ISO/IEC 9126-1:2003. Um cenário real de HU é utilizado para apresentar a aplicação real do método, e, seus resultados são: a validação do método AHP para o processo, os critérios confiabilidade e eficiência sendo determinado como os mais importantes na escolha e a alternativa produzir os fármacos, no próprio HU, com toda a biossegurança necessária foi a escolhida.
34

Percepção da enfermagem e avaliação da segurança do paciente na implantação de dispensários eletrônicos

Pozza, Camila Pereira Menezes January 2016 (has links)
Objetivos: Conhecer a satisfação e a percepção da equipe de enfermagem usuária dos dispensários eletrônicos com relação a estes equipamentos e adaptar transculturalmente o instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets para a realidade brasileira. Métodos: O estudo foi realizado em duas etapas. A primeira etapa consistiu de um estudo qualitativo, do tipo exploratório, através da realização de grupos focais com os técnicos de enfermagem e enfermeiros das unidades que possuem dispensários eletrônicos. Na segunda etapa foi realizado um estudo metodológico para tradução e validação do instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets através da realização das etapas de tradução por dois tradutores independentes, síntese das traduções, retrotradução, síntese da retrotradução, avaliação por especialistas e pré-teste. Resultados: Durante a realização dos grupos focais a equipe de enfermagem demonstrou estar satisfeita com o uso dos dispensários eletrônicos, necessitando de algumas adequações e melhorias no processo. As etapas de adaptação transcultural do instrumento foram realizadas obtendo-se um instrumento adaptado para a realidade brasileira que pode auxiliar no planejamento da implantação de dispensários eletrônicos. Faz-se necessária a realização de validação externa deste instrumento para utilização na realidade nacional. Conclusões: Neste estudo ficou evidente a satisfação dos usuários dos dispensários eletrônicos com o uso destes equipamentos e a importância de um planejamento adequado para a implantação de novas tecnologias. Demonstra-se a importância de um trabalho conjunto entre as equipes de farmácia e enfermagem na implantação e utilização de dispensários eletrônicos com foco na segurança do paciente. / Objectives: To know the satisfaction and perception of the user nursing staff of automated dispensing cabinets about this equipment and cross-culturally adapt the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets for the Brazilian reality. Methods: The study was conducted in two stages. The first stage consisted of a qualitative study, exploratory, by conducting focus groups with nursing technicians and nurses of the units that use automated dispensing cabinets. In the second stage it was carried out a methodological study for the translation and validation of the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets by performing the translation stages by two independent translators, synthesis of translations, back translation, synthesis of back translation, evaluation by experts and pretest. Results: During the course of the focus groups the nursing staff proved to be satisfied with the use of automated dispensing cabinets, requiring some adjustments and improvements in the process. The steps of cross-cultural adaptation of the instrument were carried out obtaining a tool that can assist in planning the implementation of automated dispensing cabinets adapted to the Brazilian reality. Conducting external validation of this instrument for use at the national reality is necessary. Conclusions: In this study it was evident the satisfaction of users of automated dispensing cabinets with the use of this equipment and the importance of proper planning for the deployment of new technologies. It demonstrates the importance of joint work between the pharmacy and nursing staff in the implementation and use of automated dispensing cabinets with a focus on patient safety.
35

Influência da reutilização na biocompatibilidade de materiais médico-hospitalares de uso único / Influence reuse in the biocompatibility of hospital medical materials for single use

Monica Valero da silva 27 February 2002 (has links)
A prática da reutilização de produtos médico-hospitalares de uso único vem sendo aplicada desde meados da década de setenta. A principal razão que tem contribuído para disseminação desta conduta pelas instituições hospitalares radicadas tanto nos países em desenvolvimento como naqueles considerados ricos, tem sido a aparente economia de custos. Apesar dos riscos relacionados com a prática da reutilização, como reações pirogênicas, danos ocasionados por bactérias consideradas patogênicas em pacientes imunologicamente comprometidos, danos na integridade fisica dos produtos, assim como aumento do período de permanência dos pacientes no hospital, têm despertado o interesse em avaliar aspectos fisicos e biológicos dos produtos médico-hospitalares reutilizados. Baseando-se nestas considerações foram aplicados desafios com esporos de Bacillus Subtilis varo niger ATCC 9372 e endotoxina bacteriana E. coli 055:B5. Os produtos desafiados foram cateteres intravenosos, torneira três vias e tubos de traqueostomia. A possível presença microbiana foi investigada após contaminação intencional dos esporos de B. Subtillis (107 ufc/unid.) com submissão das unidades contaminadas à limpeza e posterior esterilização, utilizando óxido de etileno/CFC na proporção 12:88. Os ciclos de reprocessamentos simulados de produtos médico-hospitalares consistiram de contaminação de cada unidade teste com carga microbiana, lavagem com detergente enzimático, secagem e esterilização. Ao término de cada ciclo de reprocessamento foram separadas unidades representativas para avaliação por contagem microbiana (pour plate), testes de esterilidade por inoculação direta e indireta, citotoxidade por cultura de células e microscopia eletrônica de varredura. A eficiência da esterilidade foi avaliada tanto por contagem microbiana como pelos testes de esterilidade, que resultaram em níveis microbianos de 103 ufc/unid. e detecção de contaminação até o 6° ciclo de reprocessamento nos cateteres intravenosos, tubos de traqueostomia e torneiras três vias. A segurança dos reprocessamentos dos produtos médico-hospitalares foi avaliada pela cultura de células de fibroblastos de camundongo (NCTC clone 929), as quais não apresentaram toxicidade. Entretanto, os resultados obtidos durante microscopia eletrônica de varredura comprovaram presença de carga microbiana após 10° ciclo de reprocessamento, assim como danos na superficie polimérica. Durante desafio com endotoxina bacteriana, que consistiu em contaminar as unidades com 200 UE, secagem e exposição ao ciclo de esterilização com óxido de etileno/CFC (12:88), verificou-se que após ciclos de reprocessamentos simulados, totalizando dez ciclos, foi possível detectar valores de recuperação de endotoxina em torno de 100%. Os cateteres-guia que foram adquiridos em instituição hospitalar após quatro reutilizações, apresentaram níveis de contaminação de 105 ufc/unid., assim como presença de bactérias consideradas patogênicas em pacientes comprometidos imunologicamente, já a detecção de endotoxina bacteriana nestes cateteres não foi considerada significativa. Logo, as avaliações aplicadas nas unidades submetidas aos ciclos de reprocessamentos simulados, assim como nos cateteres-guia reprocessados e reutilizados quatro vezes, refletiram a realidade de algumas instituições no âmbito nacional e internacional que praticam a reutilização de produtos médico-hospitalares de uso-único. Os resultados obtidos vêm enfatizar objeções quanto à prática da reutilização, considerando que a ausência de segurança pode ocasionar em danos ao paciente. / The practices of reutilization of single use hospital medical devices came into practice since mid seventies. The main reason that has contributed for dissemination of this practice by institutional hospitals in underdeveloped as well as those considered as rich countries has been the appellant economy of costs. Despite well known risks related with the practice of reutilization, such as pyrogenic reactions, damages caused by bacteria\'s considered pathogenic in patients immunologically compromised, damages to the physical integrity of the materials, as well as prolonged permanence of the patient in the hospital, has raised interests in the evaluation of physical and biological aspects of the reused medical device. Based on these considerations, challenges had been applied with spores of Bacillus Subtilis varo niger 9372 ATCC and bacterial endotoxin E. coli 055:B5. The selected materials includes, intravenous catheters, three-way stopcocks and traqueostomy tubes. The possible presence of bacteria was investigated after intentional contamination with spores of B. Subtillis (107 cfu/unit) followed by submission of the inoculated units to the cleaning process and posterior sterilization using ethylene oxide at 12:88. The simulated reprocessing cycles of the medical device had consisted of contamination of each test unit with predetermined microbial load, washing with enzymatic detergent, drying and sterilization. At the end of each reprocessing cycle, representative sarnples had been segregated to evaluate microbial count (pour plate), terility test through direct and indirect inoculation, cytotoxicity test through cell culture and scanning electron microscopy. The efficiency of the sterility was evaluated through microbial count, as for the sterility tests, that had resulted in microbial count of 103 cfu/unit and detection of contamination until the 6th cycle of reprocessing in the intravenous catheters, three-way stopcocks and traqueostomy tubes. The safety of these reprocessed medical devices was evaluated by mouse fibroblasts cell culture (NCTC clone 929), which didn\'t presented significant toxicity. However, the results obtained by scanning electron microscopy proved the presence of microbial load after 10th reprocessing cycle, as well as damages to the polymeric surface. During challenge with bacterial endotoxin, that consisted of contaminating the units with 200 EU, drying and submission to sterilization cycles with ethylene oxide/cfe (12:88), it was verified that after ten simulated reprocessing cycles, it was possible to recover around 100% of endotoxin. The catheter guide that were acquired from institutional hospital after four times reuse, had presented levels of contamination of 105 cfu/unit, as well as presenee of bacteria considered pathogenic in patients immunologically compromised, on the other hand the detention of bacterial endotoxin in these catheters was not considered significant. The evaluations studies condueted with the units submitted to the simulated reprocessing cycles, as well as the catheter guide reprocessed and reused four times, had reflected the reality of some national and foreign hospitais which reutilize single use medical device. The results obtained lead us to raise objections to the reusing practice, considering the absence of adequate patients safety.
36

Percepção da enfermagem e avaliação da segurança do paciente na implantação de dispensários eletrônicos

Pozza, Camila Pereira Menezes January 2016 (has links)
Objetivos: Conhecer a satisfação e a percepção da equipe de enfermagem usuária dos dispensários eletrônicos com relação a estes equipamentos e adaptar transculturalmente o instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets para a realidade brasileira. Métodos: O estudo foi realizado em duas etapas. A primeira etapa consistiu de um estudo qualitativo, do tipo exploratório, através da realização de grupos focais com os técnicos de enfermagem e enfermeiros das unidades que possuem dispensários eletrônicos. Na segunda etapa foi realizado um estudo metodológico para tradução e validação do instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets através da realização das etapas de tradução por dois tradutores independentes, síntese das traduções, retrotradução, síntese da retrotradução, avaliação por especialistas e pré-teste. Resultados: Durante a realização dos grupos focais a equipe de enfermagem demonstrou estar satisfeita com o uso dos dispensários eletrônicos, necessitando de algumas adequações e melhorias no processo. As etapas de adaptação transcultural do instrumento foram realizadas obtendo-se um instrumento adaptado para a realidade brasileira que pode auxiliar no planejamento da implantação de dispensários eletrônicos. Faz-se necessária a realização de validação externa deste instrumento para utilização na realidade nacional. Conclusões: Neste estudo ficou evidente a satisfação dos usuários dos dispensários eletrônicos com o uso destes equipamentos e a importância de um planejamento adequado para a implantação de novas tecnologias. Demonstra-se a importância de um trabalho conjunto entre as equipes de farmácia e enfermagem na implantação e utilização de dispensários eletrônicos com foco na segurança do paciente. / Objectives: To know the satisfaction and perception of the user nursing staff of automated dispensing cabinets about this equipment and cross-culturally adapt the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets for the Brazilian reality. Methods: The study was conducted in two stages. The first stage consisted of a qualitative study, exploratory, by conducting focus groups with nursing technicians and nurses of the units that use automated dispensing cabinets. In the second stage it was carried out a methodological study for the translation and validation of the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets by performing the translation stages by two independent translators, synthesis of translations, back translation, synthesis of back translation, evaluation by experts and pretest. Results: During the course of the focus groups the nursing staff proved to be satisfied with the use of automated dispensing cabinets, requiring some adjustments and improvements in the process. The steps of cross-cultural adaptation of the instrument were carried out obtaining a tool that can assist in planning the implementation of automated dispensing cabinets adapted to the Brazilian reality. Conducting external validation of this instrument for use at the national reality is necessary. Conclusions: In this study it was evident the satisfaction of users of automated dispensing cabinets with the use of this equipment and the importance of proper planning for the deployment of new technologies. It demonstrates the importance of joint work between the pharmacy and nursing staff in the implementation and use of automated dispensing cabinets with a focus on patient safety.
37

Percepção da enfermagem e avaliação da segurança do paciente na implantação de dispensários eletrônicos

Pozza, Camila Pereira Menezes January 2016 (has links)
Objetivos: Conhecer a satisfação e a percepção da equipe de enfermagem usuária dos dispensários eletrônicos com relação a estes equipamentos e adaptar transculturalmente o instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets para a realidade brasileira. Métodos: O estudo foi realizado em duas etapas. A primeira etapa consistiu de um estudo qualitativo, do tipo exploratório, através da realização de grupos focais com os técnicos de enfermagem e enfermeiros das unidades que possuem dispensários eletrônicos. Na segunda etapa foi realizado um estudo metodológico para tradução e validação do instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets através da realização das etapas de tradução por dois tradutores independentes, síntese das traduções, retrotradução, síntese da retrotradução, avaliação por especialistas e pré-teste. Resultados: Durante a realização dos grupos focais a equipe de enfermagem demonstrou estar satisfeita com o uso dos dispensários eletrônicos, necessitando de algumas adequações e melhorias no processo. As etapas de adaptação transcultural do instrumento foram realizadas obtendo-se um instrumento adaptado para a realidade brasileira que pode auxiliar no planejamento da implantação de dispensários eletrônicos. Faz-se necessária a realização de validação externa deste instrumento para utilização na realidade nacional. Conclusões: Neste estudo ficou evidente a satisfação dos usuários dos dispensários eletrônicos com o uso destes equipamentos e a importância de um planejamento adequado para a implantação de novas tecnologias. Demonstra-se a importância de um trabalho conjunto entre as equipes de farmácia e enfermagem na implantação e utilização de dispensários eletrônicos com foco na segurança do paciente. / Objectives: To know the satisfaction and perception of the user nursing staff of automated dispensing cabinets about this equipment and cross-culturally adapt the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets for the Brazilian reality. Methods: The study was conducted in two stages. The first stage consisted of a qualitative study, exploratory, by conducting focus groups with nursing technicians and nurses of the units that use automated dispensing cabinets. In the second stage it was carried out a methodological study for the translation and validation of the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets by performing the translation stages by two independent translators, synthesis of translations, back translation, synthesis of back translation, evaluation by experts and pretest. Results: During the course of the focus groups the nursing staff proved to be satisfied with the use of automated dispensing cabinets, requiring some adjustments and improvements in the process. The steps of cross-cultural adaptation of the instrument were carried out obtaining a tool that can assist in planning the implementation of automated dispensing cabinets adapted to the Brazilian reality. Conducting external validation of this instrument for use at the national reality is necessary. Conclusions: In this study it was evident the satisfaction of users of automated dispensing cabinets with the use of this equipment and the importance of proper planning for the deployment of new technologies. It demonstrates the importance of joint work between the pharmacy and nursing staff in the implementation and use of automated dispensing cabinets with a focus on patient safety.
38

Seleção de medicamentos: indicadores, estratégias de implantação e contribuições para o Sistema Único de Saúde

Santana, Rafael Santos 19 February 2013 (has links)
The development of essential medicines list is one of the main policies, globally accepted, for promoting rational drug use. Despite advances in developed countries, in countries like Brazil difficulties of establishing pharmacy and therapeutics committees, as well as the maintenance of its activities are characterized as a challenge for managers of health services. This study aimed to identify indicators, strategies for implementation and impact of policies on medicines selection in public hospitals. Through an approach of evaluative research in service work is divided into three steps: 1) Exploratory Phase (initial planning of the research and literature review), 2) Field Work Phase (institutionalizing the process of medicines selection in health services using the Situational and Strategic Planning - SSP), 3) Analysis of data (measurement and processing of data collected during the study). In this study, it was possible to perform an integrative literature review that results in 45 indicators for the evaluation of drug selection in health services and to construct optimal strategies for implementation of this activity in public hospitals through the SSP. The study culminated in analysis of economic-assistance impact, establishment of DTC and definition of essential medicine lists in public hospitals. / Uma das principais políticas mundialmente aceitas para a promoção do uso racional de medicamentos é o estabelecimento de listas de medicamentos essenciais. Apesar do avanço nos países desenvolvidos, em países como o Brasil as dificuldades de implantação de Comissões de Farmácia e Terapêutica, bem como a manutenção de suas atividades se caracterizam como um desafio para os gestores dos serviços de saúde. O presente estudo teve o objetivo de identificar indicadores, estratégias para a implantação e o impacto de políticas de seleção de medicamentos em hospitais públicos. Por meio de uma abordagem de pesquisa avaliativa em serviço, o trabalho se dividiu em três etapas: 1) Fase Exploratória (planejamento inicial da pesquisa e revisão da literatura); 2) Fase de Campo (institucionalização do processo de seleção de medicamentos nos serviços de saúde por meio do Planejamento Estratégico Situacional); 3) Fase de Análise dos Dados (aferição e tratamento dos dados coletados durante o estudo). Como resultado da revisão integrativa da literatura realizada, foi constituído um painel de 45 indicadores para avaliação da seleção de medicamentos. O estudo possibilitou ainda, verificar as etapas necessárias para implantação de uma política de medicamentos essenciais e os impactos na racionalização da lista de medicamentos em serviços do SUS. A institucionalização de uma política de medicamentos essenciais resultou em redução de 27,8% do quantitativo total de itens, aumento do percentual de itens com adequação à RENAME, Lista da OMS e Diretrizes Clínicas. Após a implantação das CFT, foi constatado também um menor percentual de medicamentos com patente na lista, aumento do percentual de genéricos e redução de aproximadamente 12% dos custos relacionados à lista nos hospitais avaliados.
39

Farmácia hospitalar, segundo o modelo de gestão dos hospitais públicos de grande porte, no eixo Goiânia-Brasília / Hospital pharmacy, according management model of largest public hospitals in Goiânia-Brasília axis

Silva, Cleiton Bueno da 09 December 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-12-22T14:00:01Z No. of bitstreams: 2 Dissertação - Cleiton Bueno da Silva - 2016.pdf: 3015240 bytes, checksum: 6ef3a74652959bf065d9fdc277fa9903 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-12-27T13:09:13Z (GMT) No. of bitstreams: 2 Dissertação - Cleiton Bueno da Silva - 2016.pdf: 3015240 bytes, checksum: 6ef3a74652959bf065d9fdc277fa9903 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-12-27T13:09:13Z (GMT). No. of bitstreams: 2 Dissertação - Cleiton Bueno da Silva - 2016.pdf: 3015240 bytes, checksum: 6ef3a74652959bf065d9fdc277fa9903 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-12-09 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The different management models present today in the field of brasilian public health, from the Managerial Reform of the 1990's, still share opinions among researchers, managers, workers and users of health services, especially regarding the performance of so-called Organizations Health (OSS). Based on this scenario, the present study aimed to comparatively analyze the Hospital Pharmacy Services (SFH), according to the management model of public hospitals, since, in order to understand how the whole works, the analysis of the parts shows being extremely important and revealing. It is, therefore, a comparative, transversal study of the analytic-descriptive type. The four hospitals selected for the survey accounted for 43.9% of the total beds in the region. Group 1 SFH (direct administration) presented more heterogeneous results, and in this group, the structuring was only more complete in one of the twelve components analyzed. It is pointed out that the difference between the groups was numerically more expressive regarding the management and the four components of logistics; In particular, in meeting good storage and dispensing practices. It was verified that the Management model influences SFH and probably other hospital subsystems. There are also differences in SFH from an OSS-managed hospital to one managed by AD. It can be inferred that in relation to the structure, the greater adequacy and compliance with the recommendations, as well as the better formalization of the processes inherent to the service, occur due to the presence of legal requirements that must be fulfilled for the maintenance of the Management Agreements concluded between the OSS and the Public Power. / Os diferentes Modelos de Gestão, presentes hoje no campo da saúde pública, oriundos da Reforma Gerencial da década de 1990, ainda dividem opiniões entre pesquisadores, gestores, trabalhadores e usuários dos serviços de saúde, em especial no que diz respeito ao desempenho das chamadas Organizações Sociais de Saúde (OSS). Com base nesse cenário, o presente estudo objetivou analisar comparativamente os Serviços de Farmácia Hospitalar (SFH), segundo o modelo de gestão dos hospitais públicos, uma vez que, para entender como o todo funciona, a análise das partes mostra-se extremamente importante e reveladora. Trata-se, portanto, de um estudo comparativo, transversal do tipo analítico-descritivo. Os quatro hospitais selecionados para a pesquisa são responsáveis por 43,9 % do total de leitos da região. Os SFH do Grupo 1 (administração direta - AD) apresentaram resultados mais heterogêneos, e, nesse grupo, a estruturação só foi mais completa em um dos doze componentes analisados. Aponta-se que a diferença entre os grupos foi numericamente mais expressiva no tocante ao gerenciamento e aos quatro componentes da logística; de modo particular, no atendimento às boas práticas de armazenamento e dispensação. Constatou-se que o modelo de Gestão influencia o SFH e, provavelmente, outros subsistemas hospitalares. Há também diferenças nos SFH de um hospital gerido por OSS em relação a outro gerido por AD. Pode-se inferir que, com relação à estrutura, a maior adequação às recomendações, bem como o melhor nível de formalização dos processos inerentes ao serviço, ocorre devido à presença de exigências legais que devem ser cumpridas para a manutenção dos Contratos de Gestão celebrados entre as OSS e o Poder Público.
40

Modelagem e implantação de sistema de informações para monitorar custo de produção dos produtos fabricados pela Farmácia Hospitalar do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo / Modeling and implantation information system to monitor the production costs of manufactured products by the hospital pharmacy of Hospital das Clínicas, Faculty of Medicine, University of Sao Paulo

Marcia Lucia de Mario Marin 08 October 2004 (has links)
A partir do método de custeio por absorção, com adaptação do custeio baseado em atividades, um sistema de informações foi modelado e implantado para monitorar custo de produção, dos produtos fabricados pela farmácia hospitalar do Hospital das Clínicas da Faculdade de Medicina da USP. Foram analisados os formulários dos produtos fabricados, insumos, gastos indiretos de fabricação, controle de qualidade e totalizados os tempos gastos da mão-de-obra direta de 100 produtos fabricados em julho de 2003. Os resultados mostraram que de 35 itens produzidos com similares, 28 apresentaram custo de produção inferior ao preço do fabricante no mercado, estimando que nesse mês o HC deixou de gastar, aproximadamente, 750 mil reais com a produção interna. Os 65 itens restantes eram produtos exclusivos e especiais. Os gastos com insumos corresponderam a 69% do custo total de produção. O modelo proposto mostrou que a farmácia hospitalar pode proporcionar redução de gastos à entidade. / On the basis of the absorption costing method, with a number of adaptations from activity based costing, an information system was modeled and implanted to monitor the production costs of products manufactured by the hospital pharmacy of Hospital das Clínicas, Faculty of Medicine, University of São Paulo. Were analysed manufactured products forms, raw material, indirect manufacturing costs, quality control, and added up direct labor time for 100 manufactured products in July 2003. The results showed that out of 35 items produced with similar products in the market, 28 presented a production cost below the price of the market manufacturer. Evaluations revealed that, during this month, the institution saved about 750 thousand reais through internal production. The 65 remaining items were exclusive and special products. Raw material expenses accounted for 69% of total production costs. The proposed model showed that the hospital pharmacy can lead to expense reduction for the entity.

Page generated in 0.5286 seconds