Nekontaktní indikátory poruchových stavů na VN vedení / Contactless Fault Indicator for MV LinesPernica, Drahomír January 2011 (has links)
The theoretical findings about methods of earth faults indication are elaborated in this thesis into form, which is applicable to design contactless indicator of failure states on MV lines. This design contains electromagnetic field sensors, evaluation device and software support. The higher effectiveness of clearing of fault and better health and asset protection is supposed by using of these indicators.
|
2 |
Alocação ótima de indicadores de falta em redes de distribuição de energia elétrica utilizando modelagem matemática /Vilela, Leticia Biagi January 2018 (has links)
Orientador: Fábio Bertequini Leão / Resumo: Neste trabalho propõe-se um modelo matemático de Programação Não Linear Binária (PNLB) para resolver o problema de alocação ótima de dispositivos indicadores de falta (OPFI – Optimal Placement of Fault Indicator Devices) em redes radiais de distribuição de energia elétrica. O problema é modelado por meio de uma função objetivo que considera dois custos conflitantes: o Custo da Energia Não Suprida (CENS) e o Custo de Investimento em Sensores (CINV). O modelo matemático proposto pode ser resolvido por métodos exatos e para todos os testes simulados foram utilizados os softwares de programação matemática AMPL (A Mathematical Programming Language) e KNITRO versão 9.0.0. Para validação do método proposto, são realizados testes em um sistema de distribuição de 19 barras, e em outros dois sistemas de 34 e 70 barras, sendo que nesses dois sistemas os indicadores de falta foram alocados apenas no tronco principal desses alimentadores. Os resultados obtidos mostram que o modelo matemático é adequado para resolver o problema formulado. Assim, o método proposto traz contribuição à literatura, visto que o problema da alocação ótima desses dispositivos tem sido resolvido principalmente por meio de técnicas meta-heurísticas. / Abstract: This paper proposes a Binary Nonlinear Programming model to solve the problem of Optimal Placement of Fault Indicator Devices (OPFI) in radial distribution networks. The problem is modeled by an objective function that considers two conflicting costs: Cost of Energy Not Supplied and Cost of Investing in Sensors. The proposed mathematical model can be solved by exact methods and for all the simulated tests the mathematical programming software AMPL (A Mathematical Programming Language) and KNITRO version 9.0.0 were used. For validation of the proposed method, tests are performed in a 19-bar distribution system, and in two other systems of 34 and 70 bars, where in these two systems fault indicators were only allocated to the main trunk of these feeders. The results obtained show that the mathematical model is adequate to solve the problem formulated. Thus, the proposed method brings contribution to the literature, since the problem of optimal allocation of these devices has been solved mainly by means of metaheuristic techniques. / Mestre
|
3 |
Sistema inteligente para alocação eficiente de dispositivos indicadores de falta em alimentadores de distribuição / An intelligent system for efficient allocation of fault indicators in distribution feedersUsida, Wesley Fernando 22 August 2011 (has links)
Os dispositivos Indicadores de Faltas (IFs) contribuem para a melhoria do processo de localização de faltas em alimentadores de distribuição e, consequentemente, para a qualidade do fornecimento de energia elétrica. Todavia, a grande dificuldade de se aplicar tais dispositivos em larga escala está na escassez de metodologias eficientes que apontem em quais pontos do sistema de distribuição eles devem ser instalados. Por isso, o presente trabalho propõe uma abordagem computacional evolutiva capaz de alocar dispositivos IFs em alimentadores primários de distribuição de energia elétrica. De forma mais específica, o problema de se obter o melhor local de instalação é solucionado por meio da técnica de Algoritmos Genéticos (AGs), que busca obter uma configuração eficiente de instalação de IFs no tronco principal do alimentador de distribuição. A metodologia proposta é aplicada a dois alimentadores reais. Aspectos de viabilidade técnica e financeira dos IFs também são analisados. Os resultados apresentados comprovam a eficiência da metodologia proposta. / Fault Indicator (FIs) devices have contributed to improve the location of faults on primary feeders, and consequently the reliability of distribution systems. However, one of the main problems facing their installation in a large scale in a distribution system is the lack of efficient methods to analyze big networks and to pinpoint exactly on which buses these devices should be placed. Thus, this paper proposes an evolutionary computing strategy to solve the problem of fault indicator placement in primary distribution feeders. Specifically, a genetic algorithm (GA) is employed to search for an efficient configuration of FIs, located at the best positions in the main feeder. The proposed methodology was applied in two actual distribution feeders. Technical and financial viability aspects are also analyzed. Finally, the results confirm the efficiency of the GA approach to the FI placement problem.
|
4 |
Sistema inteligente para alocação eficiente de dispositivos indicadores de falta em alimentadores de distribuição / An intelligent system for efficient allocation of fault indicators in distribution feedersWesley Fernando Usida 22 August 2011 (has links)
Os dispositivos Indicadores de Faltas (IFs) contribuem para a melhoria do processo de localização de faltas em alimentadores de distribuição e, consequentemente, para a qualidade do fornecimento de energia elétrica. Todavia, a grande dificuldade de se aplicar tais dispositivos em larga escala está na escassez de metodologias eficientes que apontem em quais pontos do sistema de distribuição eles devem ser instalados. Por isso, o presente trabalho propõe uma abordagem computacional evolutiva capaz de alocar dispositivos IFs em alimentadores primários de distribuição de energia elétrica. De forma mais específica, o problema de se obter o melhor local de instalação é solucionado por meio da técnica de Algoritmos Genéticos (AGs), que busca obter uma configuração eficiente de instalação de IFs no tronco principal do alimentador de distribuição. A metodologia proposta é aplicada a dois alimentadores reais. Aspectos de viabilidade técnica e financeira dos IFs também são analisados. Os resultados apresentados comprovam a eficiência da metodologia proposta. / Fault Indicator (FIs) devices have contributed to improve the location of faults on primary feeders, and consequently the reliability of distribution systems. However, one of the main problems facing their installation in a large scale in a distribution system is the lack of efficient methods to analyze big networks and to pinpoint exactly on which buses these devices should be placed. Thus, this paper proposes an evolutionary computing strategy to solve the problem of fault indicator placement in primary distribution feeders. Specifically, a genetic algorithm (GA) is employed to search for an efficient configuration of FIs, located at the best positions in the main feeder. The proposed methodology was applied in two actual distribution feeders. Technical and financial viability aspects are also analyzed. Finally, the results confirm the efficiency of the GA approach to the FI placement problem.
|
5 |
Testování admitanční funkce indikátoru poruch / Testing of the admitance principle of the fault indicatorMusil, Milan January 2017 (has links)
The thesis deals with the proposal, implementation and evaluation of test for fault condition indicators. Thesis focusing on earth fault indicators based on admittance principles. These indicators must be able to evaluate earth faults in compensated, compensated with auxiliary resistor, unearthed and high-resistance earthed networks. The proposed tests verify the current and voltage measurement errors in inputs including monitored characteristic variables such as conductance and susceptance. The proposed test are applied to a selected ample of the fault indicator. As part of the tests, the indicator is subjected to secondary test using the Omicron CMC256plus tester as well as test on fault records that have been converted to COMTRADE for this purpose. The last series of tests carried out uses the physical model of the medium voltage system, where the tested equipment is subjected to fault states in the compensated whit auxiliary resistor system and isolated system. Furthermore, part of the thesis is research of new methods of earth fault detection, including their principles and function description. Also included in the thesis is an overview of manufacturers of indicators, or protection, who are involved in the production of earth fault protection.
|