• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Produção lacrimal induzida pela ciclosporina a e o tacrolimus em cães hígidos e com ceratoconjuntivite seca / Lacrimal production induced by cyclosporine A and tacrolimus in healthy dogs and keratoconjunctivitis sicca

Marconato, Francieli 10 March 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Keratoconjunctivitis sicca (kCS) is a chronic inflammatory disease common in dogs, resulting from deficiency of the precorneal tear film. It can occur as a quantitative deficiency of the aqueous component of the tear, as well as a qualitative deficiency of the lipid or mucin components of the tear film, generating instability of that film. The ocular complications of this disease affect the ocular surface provoking vascularization, pigmentation and corneal edema. In more severe cases, it can also lead to loss of corneal epithelium, ocular pain and blindness. The treatment normally used for KCS is medicated and mainly includes tear, lacrimomimetics, mucolytics and topical antibacterials. Considering the importance of keratoconjunctivitis sicca, the objective of this study was to investigate and compare the treatment with different eye drops in healthy patients with KCS. For the study, a literature review on the KCS was carried out, addressing the main treatments (article 1), 13 dogs divided into two studies were used for the second study. The animals were divided into three groups of three animals each: in the CsA col group the treatment of the cornea was performed with cyclosporin A (0,05%) eye drops, Tacro group with tacrolimus eye drops (0,03%) and the CsA pom group with cyclosporin A ointment (0,05%). In the second study (article 3), the dogs were divided into two groups of two animals each, in the CsA col group collagen treatment was performed with cyclosporin A eye drops (0,05%) and the Tacro group with tacrolimus eye drops (0,03%). A drop of the medication was instilled every 12 hours in all animals and ophthalmic evaluations were performed on days 0, 15, 30, 45, 60, 75 and 90 days. Clinical signs of conjunctival hyperemia, type of present ocular secretion, corneal opacity, corneal vascularization and corneal pigmentation in healthy dogs and with KCS were evaluated through Schirmer's Lacrimal Test (TLS), Fluorescein Test, Rose Bengal Test. Based on the literature review on KCS, the best treatment described is tacrolimus eye drops. Among the surgical techniques, nasolacrimal duct occlusion was the best outcome. When analyzed the behavior of cyclosporin A in the formulation eye drops and ointment and tacrolimus in healthy animals, cyclosporin A in the ointment formulation was the one with the best lachrymal stimulation. In patients with CCS, when compared to treatments with CsA eye drops and tacrolimus, the dogs with tacrolimus were the most successful. / A ceratoconjuntivite seca (CCS) é uma doença inflamatória crônica comum em cães, resultante de deficiência do filme lacrimal pré-corneal. Pode ocorrer como uma deficiência quantitativa do componente aquoso da lágrima, bem como uma deficiência qualitativa dos componentes lipídico ou mucínico do filme lacrimal, gerando instabilidade desse filme. As complicações oculares dessa doença afetam a superfície ocular provocando vascularização, pigmentação e edema corneal. Em casos mais graves, pode ainda cursar com perda do epitélio da córnea, dor ocular e cegueira. O tratamento normalmente utilizado para CCS é medicamentoso e inclui principalmente lacrimogênicos, lacrimomiméticos, mucolíticos e antibacterianos tópicos. Considerando-se a importância da ceratoconjuntivite seca, o objetivo deste estudo foi investigar e comparar o tratamento com diferentes colírios em pacientes hígidos e com CCS. Para o estudo realizou-se inicialmente uma revisão bibliográfica sobre a CCS abordando os principais tratamentos (artigo 1), para a segunda pesquisa foram utilizados 13 cães divididos em dois trabalhos. O primeiro trabalho (artigo 2) os animais foram divididos em três grupos de três animais cada: no grupo CsA col o tratamento da córnea foi realizado com colírio de ciclosporina A (0,05%), o grupo Tacro com colírio tacrolimus (0,03%) e o grupo CsA pom com pomada de ciclosporina A (0,05%). No segundo trabalho (artigo 3), os cães foram divididos em dois grupos de dois animais cada, no grupo CsA col o tratamento da córnea foi realizado com colírio de ciclosporina A (0,05%) e o grupo Tacro com colírio tacrolimus (0,03%). Em todos os animais foi instilado uma gota da medicação a cada 12 horas e foram realizadas avaliações oftálmicas nos dias 0, 15, 30, 45, 60, 75 e 90 dias. As avaliações ocorreram através do Teste Lacrimal de Schirmer (TLS), Prova de Fluoresceína, Teste Rosa de Bengala, além dos sinais clínicos de hiperemia conjuntival, tipo de secreção ocular presente, opacidade corneal, vascularização corneal e pigmentação corneal em cães hígidos e com CCS. Com base na revisão bibliográfica sobre CCS, o melhor tratamento descrito é o colírio de tacrolimus, entre as técnicas cirúrgicas a que obteve melhor resultado foi a oclusão do ducto nasolacrimal. Quando analisado o comportamento da ciclosporina A na formulação colírio e pomada e o tacrolimus em animais hígidos, a que apresentou melhor estimulação lacrimal foi a ciclosporina A na formulação de pomada. Em paciente com CCS, quando comparados os tratamentos com CsA colírio e o tacrolimus, os que obtiveram melhor resultado foram os cães tratados com tacrolimus.
2

Análise das alterações do piscar, do filme lacrimal e da superfície ocular induzidas pelo uso de monitor de computador / Analysis of alterations in blinking, lacrimal tear film and ocular surface induced by the use of video terminal display

Schaefer, Tania Mara Cunha 26 March 2010 (has links)
A relação trabalho e visão é tão remota que determinou a adaptação da espécie humana ao meio em que está inserida. Demonstrou-se que trabalhar em um ambiente confortável, sem doenças ocular, favorece o desempenho visual e aumenta a produtividade. Conhecer os efeitos do monitor de computador (VDT) sobre o sistema visual significa planejar melhor o ambiente de trabalho e a atividade laboral para se obter máximo conforto e produtividade. Este estudo teve como objetivo geral analisar as alterações do piscar, do filme lacrimal e da superfície ocular induzidas pelo uso de monitor de computador (VDT). Para sua realização efetivou-se um estudo transversal, descritivo, observacional, analítico, realizado na Volkswagen do Brasil, São José dos Pinhais (PR), tendo como amostra, a população de funcionários do setor administrativo que utiliza VDT, com idade acima de 18 anos, sem doenças da superfície ocular, sistema palpebral e lacrimal. O ambiente de trabalho foi caracterizado pela temperatura, grau de umidade, velocidade do ar e iluminamento. Preencheram os critérios de inclusão 108 funcionários (idade média 34,1±7,88 anos e tempo mínimo de utilização do VDT 6 horas/dia). Foram avaliados as sintomatologias, filmagem da face para mensuração do tempo entre piscadas na situação de conversação, exame do olho externo e biomicroscopia das pálpebras, conjuntiva e córnea, filmagem videoceratoscópica para determinar tempo de ruptura do filme lacrimal, avaliação da quantidade de lágrima do lago lacrimal pelo Zone-Quick Phenol Red Thread tear test, avaliação do epitélio corneano pelo teste da lissamina verde, filmagem da face dos sujeitos para mensuração do tempo entre piscadas em leitura de VDT. Ao final da jornada de trabalho, foram feitas a reavaliação do tempo de ruptura do filme lacrimal da quantidade de lágrima e a avaliação do epitélio corneano. Compararamse o tempo entre as piscadas em conversação e em uso de VDT e o tempo de ruptura do filme lacrimal, antes e ao final da jornada de trabalho. A comparação desses tempos classificou os sujeitos como expostos, com tempo médio de ruptura do filme lacrimal menor que o tempo médio entre piscadas e não expostos com tempo médio de ruptura do filme lacrimal maior que o tempo médio entre piscadas. Nas condições do estudo, em jornada de trabalho com tempo mínimo de 6 horas de uso de VDT, houve aumento da exposição da superfície ocular causada pelo aumento do tempo entre piscadas. O aumento da exposição da superfície ocular foi causado pela diminuição do tempo de ruptura do filme lacrimal constatado ao final da jornada de trabalho. O tempo entre piscadas na situação de leitura em VDT que foi significantemente maior que na situação de conversação. O tempo de ruptura do filme lacrimal, ao final da jornada de trabalho, foi significativamente menor que em seu início. A exposição ocular observada durante a jornada de trabalho com usuários de VDT, nas condições deste estudo, não causou alteração epitelial detectável ao teste da lissamina verde. Não houve alteração do volume lacrimal em olhos com exposição, antes da jornada de trabalho com VDT, nem houve alteração do volume lacrimal em olhos com exposição ocular, após a jornada de trabalho com VDT. / The relationship between work and vision is so remote that has determined the adaptation of human beings to the environment in which they are inserted. It has been demonstrated that working in a pleasant environment, without any ocular disease, has favored visual performance and increased productivity. Knowing the effects of video terminal display (VDT) on the visual system helps plan labor environments and labor activities more effectively so that optimal comfort and productivity are obtained. This transversal study, performed at Volkswagen do Brasil, São José dos Pinhais, PR, has the objective to investigate the influence of VDT labor activities on blinking, tear film and ocular surface, ocular exposure and amount of tear in the lacrimal lake. The population sample comprised VDT administrative department employees older than 18, without diseases on the ocular surface, tear film and blinking system. The evaluation of the working environment included measurements of temperature, humidity, air speed and lighting. One hundred and eight employees met the study criteria (mean age 34.1±7.88 and minimal VDT use time of 6 hours/day). Several evaluations were performed: the ocular surface symptomatology; the measurement of the blink time in conversation situations; the examination of the ocular surface and lacrimal film; a videokeratoscopy to establish the tear film break-up time; evaluation of the amount of tears of the lacrimal lake by means of the Zone-Quick Phenol Red Thread tear test; evaluation of the corneal epithelium by means of the lissamine green test; and determination of the blink time in VDT reading situations. At the end of the working period, the amount of tears and the corneal epithelium structure were re-evaluated. Comparisons between the blink time in conversation and VDT reading situations were performed before and at the end of the working day. The comparison data obtained classifies the subjects into two categories: exposed, with a tear film break-up time shorter than the mean time between blinks; and non-exposed, with tear film break-up time longer than the mean time between blinks. The findings obtained reveal that there was an increase in the ocular surface exposure caused by the increase in the time between blinks during the working period and increase of the ocular surface exposure caused by the decrease in the tear film break-up time determined at the end of the working day. The time between blinks at VDT reading situations was significantly longer than at conversation situations. The tear film break-up time at the end of the working day was significantly shorter than at the beginning. The ocular exposure during the VDT use has not caused epithelium alterations detectable at the lissamine green test. There were no alterations in the amount of tears in the eyes which underwent ocular exposure after VDT use situations.
3

Uso alogênico de células tronco e plasma rico em plaquetas no tratamento de ceratoconjuntivite seca em cão

Gandolfi, Micaella Gordon. January 2019 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Resumo: O objetivo deste estudo foi comparar e avaliar a aplicação de célula tronco mesenquimal de tecido adiposo (CTM-TA) e plasma rico em plaquetas aquecido alogênico (PRP-AA) perilacrimal em cães com ceratoconjuntivite seca (CCS), bem como, se há diferença na resposta segundo o grau de gravidade da afecção. Foram analisados 20 cães com produção lacrimal <15mm/min e distribuídos aleatoriamente em dois grupos (n=10). O grupo 1 tratado com CTM-TA (5x106 e 3x106 células) (GCTM-TA) e com grupo 2 PRP-AA (0,7mL e 0,3mL) (GPRP-AA), ambos injetados perilacrimal nas glândulas lacrimal principal e da terceira pálpebra, respectivamente. Todos os olhos foram avaliados em quatro momentos (M0 M15, M30, M60 dias). As variáveis avaliadas foram: osmolaridade da lágrima; teste lacrimal de Schirmer (TLS); sensibilidade corneal; tempo de ruptura do filme lacrimal (TRFL); pressão intraocular; espessura corneal; e biopsia da conjuntiva bulbar, além das variáveis clínico-oftalmológicas. Houve melhora nos dois grupos a partir de M15 (p<0,05) na qualidade do filme lacrimal, avaliada por meio da osmolaridade e TRFL, sem diferença entre os grupos. A produção de lágrima aumentou, entretanto notou-se diferença significativa nos animais com CCS discreta no GPRP-AA a partir do M30, e nos cães com CCS grave no GCTM-TA a partir do M30 e no GPRP-AA a partir do M60. Verificou-se melhora dos sinais clínicos da inflamação em ambos os grupos. Aplicação única perilacrimal de CTM-TA e PRP aquecido alogênicos normaliza a ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the study was to compare and evaluate the application of allogenic mesenchymal stem cell adipose tissue derived (MSCs-AD) and inativate platelet-rich plasma allogenic (PRP-IA), perilacrimal in dogs with keratoconjunctivitis sicca (KCS), and if there is difference in the response according to the degree of severity of the condition. Twenty dogs with lacrimal production <15mm/min randomly assigned to two groups were used. Group treated with MSCs-AD (5x106 and 3x106) (GMSCs-AD) and with PRP-IA (0.7ml and 0.3ml) (GPRP-IA), both intralacrimal in the main lacrimal glands and third eyelid, respectively. The eyes were evaluated in four moments after application (M0 M15, M30, M60). The variables evaluated were: tear osmolarity e; Schirmer's tear test (STT); sensitivity corneal; tear film break time (TBUT); intraocular pressure; corneal thickness; and biopsy of the bulbar conjunctiva, in addition to clinical-ophthalmologic variables. There was improvement in two groups at M15 (p <0.05) on tear film quality, assessed by osmolarity and TBUT, with there was no difference between groups. STT increased, however, statistical difference was only observed in animals with mild KCS in the GPRP-IA from the M30 and in the intense KCS at M30 in the G MSCs-AD and at M60 in the GPRP-IA. There was an improvement in the clinical signs of inflammation in both groups. The unique Intralacrimal application of MSCs-AD and PRP-IA normalizes tear film quality and improves clinical signs of inflamma... (Complete abstract click electronic access below) / Doutor
4

Análise das alterações do piscar, do filme lacrimal e da superfície ocular induzidas pelo uso de monitor de computador / Analysis of alterations in blinking, lacrimal tear film and ocular surface induced by the use of video terminal display

Tania Mara Cunha Schaefer 26 March 2010 (has links)
A relação trabalho e visão é tão remota que determinou a adaptação da espécie humana ao meio em que está inserida. Demonstrou-se que trabalhar em um ambiente confortável, sem doenças ocular, favorece o desempenho visual e aumenta a produtividade. Conhecer os efeitos do monitor de computador (VDT) sobre o sistema visual significa planejar melhor o ambiente de trabalho e a atividade laboral para se obter máximo conforto e produtividade. Este estudo teve como objetivo geral analisar as alterações do piscar, do filme lacrimal e da superfície ocular induzidas pelo uso de monitor de computador (VDT). Para sua realização efetivou-se um estudo transversal, descritivo, observacional, analítico, realizado na Volkswagen do Brasil, São José dos Pinhais (PR), tendo como amostra, a população de funcionários do setor administrativo que utiliza VDT, com idade acima de 18 anos, sem doenças da superfície ocular, sistema palpebral e lacrimal. O ambiente de trabalho foi caracterizado pela temperatura, grau de umidade, velocidade do ar e iluminamento. Preencheram os critérios de inclusão 108 funcionários (idade média 34,1±7,88 anos e tempo mínimo de utilização do VDT 6 horas/dia). Foram avaliados as sintomatologias, filmagem da face para mensuração do tempo entre piscadas na situação de conversação, exame do olho externo e biomicroscopia das pálpebras, conjuntiva e córnea, filmagem videoceratoscópica para determinar tempo de ruptura do filme lacrimal, avaliação da quantidade de lágrima do lago lacrimal pelo Zone-Quick Phenol Red Thread tear test, avaliação do epitélio corneano pelo teste da lissamina verde, filmagem da face dos sujeitos para mensuração do tempo entre piscadas em leitura de VDT. Ao final da jornada de trabalho, foram feitas a reavaliação do tempo de ruptura do filme lacrimal da quantidade de lágrima e a avaliação do epitélio corneano. Compararamse o tempo entre as piscadas em conversação e em uso de VDT e o tempo de ruptura do filme lacrimal, antes e ao final da jornada de trabalho. A comparação desses tempos classificou os sujeitos como expostos, com tempo médio de ruptura do filme lacrimal menor que o tempo médio entre piscadas e não expostos com tempo médio de ruptura do filme lacrimal maior que o tempo médio entre piscadas. Nas condições do estudo, em jornada de trabalho com tempo mínimo de 6 horas de uso de VDT, houve aumento da exposição da superfície ocular causada pelo aumento do tempo entre piscadas. O aumento da exposição da superfície ocular foi causado pela diminuição do tempo de ruptura do filme lacrimal constatado ao final da jornada de trabalho. O tempo entre piscadas na situação de leitura em VDT que foi significantemente maior que na situação de conversação. O tempo de ruptura do filme lacrimal, ao final da jornada de trabalho, foi significativamente menor que em seu início. A exposição ocular observada durante a jornada de trabalho com usuários de VDT, nas condições deste estudo, não causou alteração epitelial detectável ao teste da lissamina verde. Não houve alteração do volume lacrimal em olhos com exposição, antes da jornada de trabalho com VDT, nem houve alteração do volume lacrimal em olhos com exposição ocular, após a jornada de trabalho com VDT. / The relationship between work and vision is so remote that has determined the adaptation of human beings to the environment in which they are inserted. It has been demonstrated that working in a pleasant environment, without any ocular disease, has favored visual performance and increased productivity. Knowing the effects of video terminal display (VDT) on the visual system helps plan labor environments and labor activities more effectively so that optimal comfort and productivity are obtained. This transversal study, performed at Volkswagen do Brasil, São José dos Pinhais, PR, has the objective to investigate the influence of VDT labor activities on blinking, tear film and ocular surface, ocular exposure and amount of tear in the lacrimal lake. The population sample comprised VDT administrative department employees older than 18, without diseases on the ocular surface, tear film and blinking system. The evaluation of the working environment included measurements of temperature, humidity, air speed and lighting. One hundred and eight employees met the study criteria (mean age 34.1±7.88 and minimal VDT use time of 6 hours/day). Several evaluations were performed: the ocular surface symptomatology; the measurement of the blink time in conversation situations; the examination of the ocular surface and lacrimal film; a videokeratoscopy to establish the tear film break-up time; evaluation of the amount of tears of the lacrimal lake by means of the Zone-Quick Phenol Red Thread tear test; evaluation of the corneal epithelium by means of the lissamine green test; and determination of the blink time in VDT reading situations. At the end of the working period, the amount of tears and the corneal epithelium structure were re-evaluated. Comparisons between the blink time in conversation and VDT reading situations were performed before and at the end of the working day. The comparison data obtained classifies the subjects into two categories: exposed, with a tear film break-up time shorter than the mean time between blinks; and non-exposed, with tear film break-up time longer than the mean time between blinks. The findings obtained reveal that there was an increase in the ocular surface exposure caused by the increase in the time between blinks during the working period and increase of the ocular surface exposure caused by the decrease in the tear film break-up time determined at the end of the working day. The time between blinks at VDT reading situations was significantly longer than at conversation situations. The tear film break-up time at the end of the working day was significantly shorter than at the beginning. The ocular exposure during the VDT use has not caused epithelium alterations detectable at the lissamine green test. There were no alterations in the amount of tears in the eyes which underwent ocular exposure after VDT use situations.

Page generated in 0.0433 seconds