• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analytical Method Development of Fluorinated Silanes using Mass Spectrometry

Eklundh Odler, Tea January 2018 (has links)
The aim of this study was to develop an analytical method for fluorinated silanes. Furthermore, as a secondary aim, to explore if there would be possible to detect 1H,1H,2H,2H-perfluorooctyl triethoxysilane (6:2 PTrEtSi) and 1H,1H,2H,2H-perfluorodecyl triethoxysilane (8:2 PTrEtSi) in two different matrices, sludge and cosmetic extract. The method development included experiments using LC-MS, LC-MS/MS, UPC2, GC-MS and APGC-MS/MS and was carried out using standards containing 6:2 PTrEtSi and 8:2 PTrEtSi. The analytical method that worked best for the compounds was GC-MS/MS and an analytical method using APGC-MS/MS was developed for fluorinated silanes. The IDL for 6:2 PTrEtSi was 0.0012 μg/mL and 1.32 μg/mL for 8:2 PTrEtSi. This makes the developed method suitable for high contaminated samples, such as extracts from cosmetic products. It was concluded that a method using LC as the analytical instrument would not work for the two target compounds since they were too reactive with the mobile phase. However, LC could be a good choice for siloxanes, compounds that are formed from hydrolysis and condensation of fluorinated silanes. The samples analyzed in this study were three sludge extracts and one extract from a cosmetic product. 6:2 PTrEtSi was expected to be detected in the cosmetic sample since the compound was stated on the table of contents of the cosmetic product. No detection of 6:2 TrEtSi or 8:2 TrEtSi could be made in either of the samples. The reason for this was suspected to be transformation or degradation of the compounds into other compounds. Therefore, a full scan of the cosmetic sample using LC-MS/MS was included in the experiment as an addition to verify the suspicions that compounds such as siloxanes could have been formed. An interesting peak was discovered with m/z 947 which could be a disiloxane of 6:2 PTrEtSi.

Page generated in 0.0894 seconds