• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 4
  • 2
  • 1
  • Tagged with
  • 23
  • 15
  • 10
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

La détermination d’un seuil moteur pour la stimulation vestibulaire galvanique (GVS) basé sur l’évaluation de l’accélération de la tête

Mikhail, Youstina 12 1900 (has links)
INTRODUCTION: La stimulation vestibulaire galvanique (GVS) est utilisée pour évaluer l’intégrité du système vestibulaire et améliorer notre compréhension des mécanismes de l‘équilibre. Néanmoins les réponses évoquées montrent une grande variabilité interindividuelle ce qui rend la compréhension du rôle du système vestibulaire difficile. OBJECTIF: Développer un protocole d’évaluation d’un seuil vestibulaire objectif spécifique à la personne. MÉTHODES: Dix-huit sujets sains droitiers se tenaient debout sur une plate-forme de force, les yeux fermés, la tête vers l’avant. L’accélération de la tête était enregistrée lorsque la GVS (durée: 200 ms) était appliquée à des intensités de 1 à 4,5mA. Des courbes de recrutement ont été générées afin de déterminer le seuil objectif (T). Puis, les participants ont été stimulés à différentes intensités relatives au seuil (0,5T; 0,75T; 1T et 1,5T). L’aire de l’ellipse de confiance (AE) à 95%, la vitesse de déplacement du centre de pression (CoP) et l’activité électromyographique du soléaire (SOL) ont été mesurées. RÉSULTATS: 1) Un seuil objectif a été déterminé pour chaque sujet basé sur l’accélération de la tête. 2) L’aire de l’ellipse, pendant la stimulation, corrélait avec l’intensité de stimulation (r=0,95; p=0,03). 3) L’amplitude de la 1ère phase du patron triphasique de la vitesse de déplacement du CoP corrélait aussi avec l’intensité de stimulation (r=0,98; 0,04). 4) En plus, l’amplitude de la réponse musculaire à moyenne latence induite par la GVS sur le SOL montrait une corrélation significative avec l’intensité de stimulation (r=0,7; p=0,045). DISCUSSION: Un seuil objectif vestibulaire peut être identifié par un accéléromètre. Les réponses vestibulaires mesurées par l’AE et le CoP sont proportionnelles aux intensités de stimulation relatives au seuil objectif déterminé. / INTRODUCTION: Galvanic vestibular stimulation (GVS) is used to assess the integrity of the vestibular system and to improve our understanding of the mechanisms of balance. However, the GVS-induced responses show great inter-individual variability, which makes it difficult to understand the contribution of the vestibular system in maintaining balance. OBJECTIVE: To develop a protocol identifying an objective vestibular threshold for GVS in order to limit this variability observed on GVS-induced responses. METHODS: Eighteen healthy right-handed subjects stood on a force platform, eyes closed, head forward. The head acceleration was recorded when the GVS (duration: 200 ms) was applied at intensities varying between 1 and 4.5mA. Recruitment curves were reconstructed to determine the objective threshold (T). Then, the participants were stimulated at different intensities relative to threshold (0.5T; 0.75T; 1T and 1.5T). The 95% confidence ellipse area, the velocity of the center of pressure (CoP) displacement and the electromyographic activity of the soleus muscle (SOL) were measured. RESULTS: 1) An objective threshold was determined for each subject based on the acceleration of the head. 2) The area of the ellipse, during stimulation, correlated with the stimulation intensity (r = 0.95; p = 0.03). 3) The amplitude of the 1st peak of the three-phase CoP velocity pattern also correlated with the stimulation intensity (r = 0.98; 0.04). 4) In addition, the amplitude of the medium latency response induced by the GVS on the SOL showed a significant correlation with the stimulation intensity (r = 0.7; p = 0.045). DISCUSSION: An objective vestibular threshold can be identified by an accelerometer. The vestibular responses measured by the ellipse area and the CoP are proportional to the stimulation intensities relative to the determined objective threshold.
22

Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante / Galvanic isolation by acoustic device : the CMUT, an innovative solution

Ngo, Sophie 17 October 2013 (has links)
Les dispositifs d’isolation galvanique intégrés au sein des systèmes de commande d’interrupteurs de puissance doivent répondre à une demande accrue en performance, facilité d’intégration et efficacité énergétique. Les transducteurs ultrasonores capacitifs micro-usinés (cMUT : capacitive Micromachined Ultrasonic Transducer), capables d’émettre et de recevoir des ondes ultrasonores, semblent une alternative tout à fait nouvelle à la fonction d’isolation galvanique. Ces travaux de thèse ont pour objectif de démontrer la faisabilité d’un dispositif basé sur la technologie cMUT. Le principe de fonctionnement consiste à transmettre une information grâce à une communication par onde acoustique de volume entre deux réseaux de cMUT placés de part et d’autre d’un substrat. Nous focalisons, en premier lieu, ces travaux sur le processus de fabrication par micro-usinage de surface des cMUT ainsi que les techniques de réalisation des dispositifs en structure double face sur substrat de silicium. L’étude permet d’identifier le collage de substrat comme une solution de fabrication industrialisable. Suite à la réalisation des dispositifs, la caractérisation électro-mécanique des cMUT est une étapeessentielle à la validation de leur fonctionnalité en tant que dispositifs émetteurs. L’étude débute par uneévaluation des propriétés mécaniques du matériau constituant la membrane et qui impactent directementle comportement global des cMUT. Puis, la caractérisation du comportement statique et dynamique descMUT permet d’extraire les paramètres tels que la fréquence de résonance, la tension de collapse etl’efficacité électro-mécanique qui définissent le mode de pilotage d’un tel système.Finalement, la validation du concept de transmission et de détection d’ondes ultrasonores est réaliséegrâce à des mesures de vibrométrie laser Doppler. Les résultats apportent des éléments de réponse quantau mode de propagation des ondes et permettent d’identifier les topologies de meilleure efficacité entransmission acoustique. Enfin, l’intégration du prototype dans l’application de commanded’interrupteur de puissance démontre la faisabilité du concept de transformateur acoustique basé sur latechnologie cMUT. / Galvanic isolation devices integrated into switch command systems must be able to answer all of the increasing demand for performance, energetic efficiency and integration easiness. The capacitive micro machined ultrasonic transducers (cMUT), able to emit and receive ultrasounds, could be an entirely new alternative to the function of galvanic isolation. This work aims to demonstrate the feasibility of a cMUT-based device. The operating principle consists in transmitting information thanks to a bulk acoustic wave between two cMUT arrays located on both sides of a substrate. We first focus on cMUT surface micromachining fabrication process and techniques of double-side device manufacturing. Our study allows us to identify wafer bonding as a realistic industrial solution. After device fabrication, electro-mechanical of cMUT is an essential step to validate their functionality as ultrasonic emitters. The study starts with the mechanical properties evaluation of the membrane material. These properties directly impact the global behavior of cMUT. Then, the characterization of cMUT static and dynamic behavior allows extracting parameters as resonance frequency, collapsing voltage and electro-mechanical efficiency which define the actuation mode of such a system. Finally, the validation of transmission and reception of ultrasonic waves is evaluated by vibrometer laser Doppler measurements. Results bring elements concerning the waves propagation modes and allow identifying the best acoustical efficiency in regard to the topology. In conclusion, the prototype integration in the application of power switch command demonstrates the feasibility of acoustic transformer concept based on cMUT technology.
23

Characterization and design of high-switching speed capability of GaN power devices in a 3-phase inverter / Caractérisation et design de la monté en fréquence de découpage d'un onduleur 3 phases avec des transistors en GaN

Perrin, Rémi 09 January 2017 (has links)
Le projet industriel français MEGaN vise le développement de module de puissance à base de compostant HEMT en GaN. Une des application industrielle concerne l’aéronautique avec une forte contrainte en isolation galvanique (>100 kV/s) et en température ambiante (200°C). Le travail de thèse a été concentré sur une brique module de puissance (bras d’onduleur 650 V 30 A). L’objectif est d’atteindre un prototype de facteur de forme peu épais, 30 cm2 et embarquant l’ensemble des fonctions driver, alimentation de driver, la capacité de bus et capteur de courant phase. Cet objectif implique un fort rendement énergétique, et le respect de l’isolation galvanique alors que la contrainte en surface est forte. Le manuscrit, outre l’état de l’art relatif au module de puissance et notamment celui à base de transistor GaN HEMT, aborde une solution d’isolation de signaux de commande à base de micro-transformateur. Des prototypes de micro-transformateur ont été caractérisés et vieillis pendant 3000 H pour évaluer la robustesse de la solution. Les travaux ont contribué à la caractérisation de plusieurs composants GaN afin de mûrir des modèles pour la simulation circuit de topologie de convertisseur. Au sein du travail collaboratif MEGaN, notre contribution ne concernait pas la conception du circuit intégré (driver de grille), tout en ayant participé à la validation des spécifications, mais une stratégie d’alimentation du driver de grille. Une première proposition d’alimentation isolée pour le driver de grille a privilégié l’utilisation de composants GaN basse-tension. La topologie Flyback résonante avec clamp permet de tirer le meilleur parti de ces composants GaN mais pose la contrainte du transformateur de puissance. Plusieurs technologies pour la réalisation du transformateur ont été validées expérimentalement et notamment une proposition originale enfouissement du composant magnétique au sein d’un substrat polymère haute-température. En particulier, un procédé de fabrication peu onéreux permet d’obtenir un dispositif fiable (1000 H de cyclage entre - 55 ; + 200°C), avec un rendement intrinsèque de 88 % pour 2 W transférés. La capacité parasite d’isolation est réduite par rapport aux prototypes précédent. Deux prototypes d’alimentations à forte intégration utilisent soit les transistors GaN basse tension (2.4 MHz, 2 W, 74 %, 6 cm2), soit un circuit intégré dédié en technologie CMOS SOI, conçu pour l’application (1.2 MHz, 2 W, 77 %, 8.5 cm2). Le manuscrit propose par la suite une solution intégrable de mesure de courant de phase du bras de pont, basé sur une magnétorésistance. La comparaison expérimentale vis à vis d’une solution à résistance de shunt. Enfin, deux prototypes de convertisseur sont décrits, dont une a pu faire l’objet d’une validation expérimentale démontrant des pertes en commutation réduites. / The french industrial project MEGaN targets the development of power module based on GaN HEMT transistors. One of the industrial applications is the aeronautics field with a high-constraint on the galvanic isolation (>100 kV/s) and ambient temperature (200°C). The intent of this work is the power module block (3 phases inverter 650 V 30 A). The goal is to obtain a small footprint module, 30 cm2, with necessary functions such as gate driver, gate driver power supply, bulk capacitor and current phase sensor. This goal implies high efficiency as well as respect of the constraint of galvanic isolation with an optimized volume. This dissertation, besides the state of the art of power modules and especially the GaN HEMT ones, addressed a control signal isolation solution based on coreless transformers. Different prototypes based on coreless transformers were characterized and verified over 3000 hours in order to evaluate their robustness. The different studies realized the characterization of the different market available GaN HEMTs in order to mature a circuit simulation model for various converter topologies. In the collaborative work of the project, our contribution did not focus on the gate driver chip design even if experimental evaluation work was made, but a gate driver power supply strategy. The first gate driver isolated power supply design proposition focused on the low-voltage GaN HEMT conversion. The active-clamp Flyback topology allows to have the best trade-off between the GaN transistors and the isolation constraint of the transformer. Different transformer topolgies were experimentally performed and a novel PCB embedded transformer process was proposed with high-temperature capability. A lamination process was proposed for its cost-efficiency and for the reliability of the prototype (1000 H cycling test between - 55; + 200°C), with 88 % intrinsic efficiency. However, the transformer isolation capacitance was drastically reduced compared to the previous prototypes. 2 high-integrated gate driver power supply prototypes were designed with: GaN transistors (2.4 MHz, 2 W, 74 %, 6 cm2), and with a CMOS SOI dedicated chip (1.2 MHz, 2 W, 77 %, 8.5 cm2). In the last chapter, this dissertation presents an easily integrated solution for a phase current sensor based on the magnetoresistance component. The comparison between shunt resistor and magnetoresistance is experimentally performed. Finally, two inverter prototypes are presented, with one multi-level gate driver dedicated for GaN HEMT showing small switching loss performance.

Page generated in 0.0387 seconds