• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 16
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 62
  • 15
  • 10
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo da fluência em geotêxteis através de ensaios não confinados convencionais e acelerados / Creep of geotextiles through conventional and accelerated uncofined tests

Baras, Luiz Claudio Schwarz 04 July 2001 (has links)
Este trabalho apresenta resultados de ensaios de fluência não confinada executados pelo modo convencional e acelerado. Foi possível avaliar alguns parâmetros que influenciam o fenômeno da fluência em geotêxteis não tecidos, e ainda comparar o comportamento de dois geotêxteis ensaiados, um de polipropileno e outro de poliéster. Construíram-se as curvas isócronas dos materiais estudados e as análises das mesmas mostram que os geotêxteis de poliéster sofrem menores reduções de rigidez quando submetidos a carregamentos constantes do que os geotêxteis de polipropileno, os resultados dos ensaios acelerados apresentam-se estaticamente compatíveis com os resultados convencionais, denotando a viabilidade do Stepped Isothermal Method (SIM) como ensaio de caracterização fluência não confinada para geotêxteis não tecidos. / This work presents results of conventional and accelerated unconfined creep tests. Some factors that influence the creep behavior of nonwoven geotextiles are evaluated. The performance of polypropylene and polyester geotextiles is also compared. Isochronous curves show that the polyester geotextiles have a smaller rigidity reduction when compared with the polypropylene geotextiles when submitted to constant loads. The results of the accelerated tests are statistically compatible with the results of conventional tests, indicating that the Stepped Isothermal Method is a feasible approach for characterizing the creep behavior of nonwoven geotextiles.
52

Estudo da fluência em geotêxteis através de ensaios não confinados convencionais e acelerados / Creep of geotextiles through conventional and accelerated uncofined tests

Luiz Claudio Schwarz Baras 04 July 2001 (has links)
Este trabalho apresenta resultados de ensaios de fluência não confinada executados pelo modo convencional e acelerado. Foi possível avaliar alguns parâmetros que influenciam o fenômeno da fluência em geotêxteis não tecidos, e ainda comparar o comportamento de dois geotêxteis ensaiados, um de polipropileno e outro de poliéster. Construíram-se as curvas isócronas dos materiais estudados e as análises das mesmas mostram que os geotêxteis de poliéster sofrem menores reduções de rigidez quando submetidos a carregamentos constantes do que os geotêxteis de polipropileno, os resultados dos ensaios acelerados apresentam-se estaticamente compatíveis com os resultados convencionais, denotando a viabilidade do Stepped Isothermal Method (SIM) como ensaio de caracterização fluência não confinada para geotêxteis não tecidos. / This work presents results of conventional and accelerated unconfined creep tests. Some factors that influence the creep behavior of nonwoven geotextiles are evaluated. The performance of polypropylene and polyester geotextiles is also compared. Isochronous curves show that the polyester geotextiles have a smaller rigidity reduction when compared with the polypropylene geotextiles when submitted to constant loads. The results of the accelerated tests are statistically compatible with the results of conventional tests, indicating that the Stepped Isothermal Method is a feasible approach for characterizing the creep behavior of nonwoven geotextiles.
53

Utilização de leitos de drenagem no desaguamento de lodos anaeróbios. / Anaerobic sludge dewatering by modified drying beds.

Fernando Cintra Mortara 15 September 2011 (has links)
O método de desaguamento por leitos de drenagem foi desenvolvido por Cordeiro a partir do ano de 1993 (CORDEIRO, 2001) para o desaguamento de lodos de Estações de Tratamento de Água. A sua aplicação para lodos de lagoas de estabilização de esgotos foi feita por Fontana et al. (2007). Este trabalho teve por objetivo avaliar a utilização de leitos de drenagem no desaguamento de lodos produzidos em reatores UASB. Para tanto foram realizados ensaios em laboratório, utilizando testes do tempo de drenagem, para avaliar a influência de diferentes doses e tipos de polímeros no desaguamento do lodo. Alguns geotêxteis foram utilizados como meio filtrante nos funis de Buchner e também avaliados pelo teste do tempo de drenagem. Após escolhidas a manta e o polímero que apresentaram os melhores resultados em laboratório, foram desenvolvidos ensaios em escala piloto, com a utilização de três unidades cobertas de leitos de drenagem, cada um com dimensões de 1,58 m x 1,09 m por 0,5 m de altura. Para a avaliação do efeito das diferentes doses de polímero em escala piloto, foram utilizadas doses de polímero de 0 a 8 g/kg de sólidos totais (peso seco) e mantida a taxa de aplicação de sólidos em 15 kgST/m².ciclo (a concentração de sólidos no lodo foi de aproximadamente 27 g/L). Os resultados indicaram que com doses de polímero =2 g/kgST (peso seco) obtinha-se teor de sólidos no lodo de cerca de 13% após 1 dia e 20% após 10 a 15 dias. Para se atingir teor de sólidos de 25 a 30% o período de secagem necessário foi de cerca de 30 dias. Embora que mesmo sem a aplicação de polímeros o comportamento do lodo fosse semelhante ao de lodos condicionados com polímero, em relação à evolução do teor de sólidos em função dos períodos de secagem, observou-se certa dificuldade na remoção do lodo desaguado e principalmente na limpeza das mantas geotêxteis. Para avaliar diferentes taxas de aplicação superficial de sólidos, foram ensaiadas taxas entre 9 e 22 kgST/m².ciclo. A evolução do teor de sólidos, ao longo do período de secagem dos 3 ensaios realizados, indicou que taxas mais altas de aplicação de sólidos não diminuem as velocidades de secagem, sugerindo que, inclusive, taxas mais altas poderiam ser ensaiadas. / The method of dewatering sludge through Drainage Beds was originally developed in 1993 by Cordeiro (CORDEIRO, 2001) with sludge from Water Treatment Plants. Fontana et al. (2007) used sludge from wastewater stabilization ponds with positive results. The purpose of this research is the evaluation of the drainage bed method to dewater sludge from UASB reactors. Several laboratory trials were performed, measuring drainage times to assess the influence of different polymer types and doses on sludge dewatering. Few geotextiles were used as filter on the drainage time test to evaluate their performance. Once the polymer and the geotextile that best performed in the laboratory were chosen, several pilot experiments were performed with the use of three covered units of drainage beds, each measuring 1.58m x 1.09m (width) x 0.5m (height). For the evaluation of different polymer conditioning doses on a pilot scale, doses from 0 to 8 g/kg of total solids (dry weight) were used and the applied rate of solids kept at 15 kgTS/m².cycle (the concentration of solids in the sludge was of approximately 27 g/L). Results indicated that with the use of polymer doses =2 g/kgTS (dry weight), approximately 13% of total solids in the sludge was observed after one day, which increased to approximately 20% after 15 days. To reach 25% to 30% of total solids in the sludge, the drying time required was circa 30 days. Even without the application of polymers, the behavior of sludge in terms of total solids during the drying period was similar to the sludge conditioned with polymers. Although, with the unconditioned sludge, some difficulty to remove the dewatered sludge cake was observed, mainly in cleaning of the geotextile sleeves. In order to evaluate different application rates of solids, the pilot experiments included rates between 9 and 22 kgTS/m².cycle. The behavior of the total solids in the cake during the drying period of the three experiments suggested that the higher rates of application of solids does not reduce the drying speed, indicating that higher rates can be targeted in future research projects.
54

Avaliação de camadas de proteção para geomembranas de PVC e PEAD / Assessment of the performance of protective layers for PVC and HDPE geomembranes

Karla Maria Wingler Rebelo 03 February 2009 (has links)
O presente trabalho investiga o desempenho de geotêxteis e de solos como elementos de proteção para geomembranas de polivinil clorado (PVC) e de polietileno de alta densidade (PEAD). Foram utilizadas geomembranas de PVC com espessuras de 1,0 e 2,0 mm e de PEAD com espessuras de 1,5 e 2,0 mm. Como camadas de proteção utilizaram-se geotêxteis não tecidos de poliéster (PET), com gramaturas de 130, 300, 400 e 600 g/\'M POT.2\', e de polipropileno (PP), com gramatura de 400 e 600 g/\'M POT.2\', além de uma areia de granulometria fina a média e uma areia argilosa típica da região Centro-Oeste do Estado de São Paulo. O estudo foi conduzido através da construção de um aterro experimental para simulação dos danos de instalação em campo e da realização de ensaios índice e de desempenho em laboratório. A eficiência dos materiais de proteção foi avaliada através da análise qualitativa e quantitativa das amostras de geomembranas danificadas. Os resultados dos ensaios de laboratório índice mostraram que a introdução do geotêxtil aumenta a resistência à punção da geomembrana, e que o acréscimo de resistência é função das características de resistência à tração do geotêxtil e da geomembrana. O maior incremento de resistência à punção foi observado na geomembrana com menor resistência à tração. Os resultados dos ensaios de campo mostraram que a introdução do elemento de proteção reduz os danos mecânicos apesar da alteração de algumas das propriedades físicas e de desempenho nas geomembranas. Da análise dos resultados, verificou-se que a eficiência dos geotêxteis no campo não é função de suas características de tração, conforme constatado nos ensaios índices. A análise também sugere que os danos mecânicos no campo foram mais intensos do que nos ensaios de desempenho em laboratório. / The performance of non-woven geotextiles and soils as protection elements of polyvinyl chloride (PVC) and high density polyethylene (HDPE) geomembranes is studied. The materials used comprised PVC geomembranes of 1,0 and 2,0 mm thickness and HDPE geomembranes of 1,5 and 2,0 mm thickness while the protective layers were of non-woven polyester (PET) geotextiles with mass per unit area of 130, 300, 400 e 600 g/\'M POT.2\' and polypropylene (PP) with mass per unit area of 400 e 600 g/\'M POT.2\'. It was also used protective layers made of a fine to medium sand and a typical clayey sand of central area of the State of São Paulo. The study was based on an experimental landfill built to simulate the damage associated to construction procedures and on index and performance laboratory tests. Through qualitative and quantitative analysis of damaged geomembranes, the behavior of each protective element was evaluated. Index laboratory test results have shown that the geotextile is able to increase the geomembrane puncture strength and that the strength increase is related to the tensile strength of geotextile and geomembrane. For similar geotextiles, the larger increase in puncture strength was observed for the geomembrane that presented the lower tensile strength. Visual observation of field tests has shown that the introduction of protective layers reduces the mechanical damage; however some physical and performance properties of geomembrane have changed. It was also observed that the performance of geotextiles in the experimental landfill does not depend on the tensile strength, as observed in laboratory index tests. Test results also suggest that field damage associated to the landfill construction are more intense than that observed in laboratory tests such as the dynamic puncture test.
55

Avaliação experimental de protótipos de estruturas de contenção em solo reforçado com geotêxtil / Field monitoring behavior of geotextile-reinforced soil retaining wall prototypes

Carlos Vinicius dos Santos Benjamim 09 June 2006 (has links)
Apesar das vantagens relacionadas ao uso de estruturas de contenção em solo reforçado, a maioria das obras em nosso país ainda é executada por soluções convencionais. A ausência de um conhecimento mais profundo sobre o real comportamento das estruturas em solo reforçado, principalmente em termos de deslocamentos, certamente impede uma utilização mais intensa desse tipo de obra no Brasil. Com isso, para contribuir para um melhor entendimento do desempenho de estruturas em solo reforçado, foram construídos oito protótipos de estrutura de contenção em solo reforçado com geotêxtil, com 4,0 m de altura cada. Todas as estruturas foram instrumentadas, principalmente visando os deslocamentos, para avaliar o comportamento de campo. Adicionalmente, foi realizada a análise, em longo prazo, de um talude íngreme com 15,3 m de altura, construído no estado americano de Idaho, em que foram realizadas leituras até cinco anos após o fim da construção. Esse trabalho apresenta os resultados de cada protótipo construído, juntamente com os resultados do talude íngreme em Idaho, tanto em curto, quanto em longo prazo. As análises desenvolvidas compreendem, além da avaliação dos resultados individuais de cada estrutura, uma análise paramétrica entre todos os protótipos, investigando entre outros fatores, o tipo de solo, tipo de geossintético e geometria interna das estruturas. Além disso, foi realizada uma abordagem especial sobre a análise em longo prazo do protótipo 7. Dentre as conclusões mais importantes obtidas nesta pesquisa, podem-se citar as grandes deformações de fluência registradas no protótipo 7, a tendência de formação de uma superfície potencial de ruptura linear para os protótipos construídos com solo granular e de espiral logarítmica para os protótipos construídos com solos coesivos, a importância da coesão no bom comportamento das estruturas e a redução das movimentações verticais das estruturas com o acréscimo do teor de areia na granulometria do solo / Despite the important advantages associated with the use of geotextiles as reinforcement, most retaining walls in Brazil still use more conventional. The lack of field monitoring data regarding the internal and face displacements of these structures has certainly prevented broader use of this reinforced soil technology. This study addresses several aspects related to the behavior of geotextile-reinforced soil structures, such as the deformability of reinforcement materials under the confinement of soil, and quantification of the actual failure mechanisms. To achieve these goals, eight 4.0 m high geotextile-reinforced soil retaining wall prototypes were built and instrumented in order to quantify their behavior under ambient atmospheric conditions. Granular and poorly draining backfills were used in this study. Innovative construction methods and instrumentation were developed specifically for this research program. A significant laboratory testing program was conducted to quantify the stress-strain properties of the soils and geosynthetics involved in the construction of the walls. As a reference, the behaviors of these prototype structures were compared with that of a long term analysis of a steep slope in Idaho, USA. This wall is 15.3 m high, with displacement measurements carried out until five years after the end of the construction. A parametric analysis was conducted for the prototypes, in order to investigate the effects of soil type, reinforcement type and internal geometry of the structures. Among the most important conclusions obtained in this research, it is the large creep strains observed in prototype 7, the tendency of a linear potential slip surface observed for the walls constructed with granular backfills, and a log spiral slip surface for the prototypes constructed with cohesive backfills, the importance of the apparent cohesion in the behavior of the structures, and the reduction of the vertical movements of the structures with the increase of the amount of sand in the grain size distribution of the soil
56

Two-Dimensional Analysis of Stacked Geosynthetic Tubes

Klusman, Craig Raymond 10 July 1998 (has links)
Geosynthetic tubes filled with a slurry-mix are considered. The mix is usually dredged from a nearby area and pumped directly into the tubes. The tubes are used in a variety of applications including breakwaters, groins, and temporary levees. This thesis considers single and stacked geosynthetic tubes resting on rigid and deformable foundations. A two-dimensional analysis is performed on the cross-section of a very long tube. The program Mathematica is utilized for the analysis. A few assumptions are made regarding the general behavior of the tube. The tube is assumed to be an inextensible membrane with no bending stiffness. To allow for a closed-form integral solution, it is assumed that no friction exists between the tubes and at the foundation. A single tube, two stacked tubes, and a 2-1 formation are studied. Both rigid and deformable foundations are considered. The deformable foundation is modeled as a tensionless Winkler foundation with normal forces proportional to the downward deflection of the ground. An external water load on one side is also investigated for a single tube and a 2-1 formation, with rigid blocks to prevent the structure from sliding along the ground. Example cross-sectional profiles are given. Results from the analysis include structure height, circumferential tension, and ground deflections. / Master of Science
57

Using palm-mat geotextiles for soil conservation on arable loamy sands in the United Kingdom

Bhattacharyya, Ranjan January 2009 (has links)
To date, most studies on the effectiveness of geotextiles on soil erosion rates were conducted in laboratory experiments for <1 h. Hence, at Hilton, East Shropshire, UK, this study investigated the effectiveness of palm-mat geotextiles (Borassus and Buriti mats) in reducing rainsplash erosion, runoff and soil loss and changing selected soil properties under field conditions over two years (January 2007-January 2009). Mat-cover effects on rainsplash erosion were studied in two sets on a loamy sand soil (0o slope). In both sets, six randomly-selected plots (each 1 m2) were completely matcovered and six were bare. Unlike Buriti mats, Borassus mat-cover on bare soil significantly (P<0.001) decreased rainsplash erosion (by ~89%). Duplicate runoff plots (10 x 1 m on a 15o slope) had five treatments (bare, permanent grass, Borassus completely-cover, Borassus buffer strip and Buriti buffer strip). Using Borassus buffer strips (area coverage ~10%) on bare soil decreased runoff by ~71% (P>0.05) and soil erosion by ~92% (P<0.001). Borassus buffer strip, Buriti buffer strip and Borassus completely-covered plots had similar effects in decreasing runoff and soil loss. However, the longevity of Borassus mats was ~twice that of Buriti mats. Despite physical protection, runoff control and sediment entrapment, biomat buffer zones may considerably alter and protect flow direction by presenting barriers and creating several cross-drains. Except Borassus completely-covered plots, all plots had significant (P<0.05) increases in topsoil (0-5 cm) bulk density and decreased aggregate stability. However, buffer strips were more effective in trapping fine particles than Borassus completely-covered plots. No treatments had significant (P>0.05) effects on changes in pH, soil organic matter, total soil carbon or N. Plots with Borassus mats significantly (P<0.05) increased total P and decreased total Ca. Treatments had no significant effects on changes in total S, Mg, Zn, Cu, Fe, Mn, Mo or Cl concentrations. Borassus buffer strips can effectively conserve soil and water and improve and maintain selected soil properties, with results similar to Borassus completely-covered plots. The mechanisms explaining the effectiveness of buffer zones require further studies under varied pedo-climatic conditions.
58

Avaliação da qualidade da água de lavagem de filtros e de lodo de decantador após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração

Oliveira, Nilton Fernandes de 12 February 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this study, we evaluated the quality of filter backwash water and sludge decanter Water Bom Jardim Treatment Plant, located in Uberlandia, Minas Gerais, after sequential treatment with drainage bed, flotation and filtration dissolved air, all bench scale. Compounds were evaluated drainage bed effluent three different types of geotextile webs: RT-21, RT-26 and RT-31, and tested three kinds of constituents of the sand grain size filters. The effluent drained, after passage through the drainage bed, passed through the flotation unit dissolved air and then by filtration units. Preliminary tests with crude sample of filter backwash water and sludge decanter, in order to characterize it and evaluate it as its physical, chemical and biological were performed. The geotextile webs used were chosen from results of previous studies, performed with the same type of system. The experiments were divided into stages I and II. In step I were conducted without addition of coagulant or auxiliary experiments on coagulation / flocculation flotation. The samples, after passage through the system, evaluating physical parameters pH, turbidity, true color and apparent color and about the chemical parameters, remaining concentrations of aluminum and iron. Step II The same tests were carried out in the same step I and determination of quality parameters, however, with aluminum sulphate dose of 5, 10 and 15 mg / L in the coagulation / flocculation flotation. Tests conducted in step I showed better performance were performed with the RT-26 blanket in the output of filter 01 with a reduction of 91.8% of the apparent color, 41.4% of true color and 97.6% turbidity. In phase II trials conducted in the best performance was drained with the RT-mat 26 the output of the filter 02 when subjected to a dosage of 15 mg / L aluminum sulfate as a coagulant agent. There was a reduction of 96.4% of the apparent color, 86.2% of true color and 99.6% turbidity. The presented results confirm the efficiency of the system in removing solids present in the water washing of filters and ETA decanter sludge studied and confirmed the capability of using this system as an alternative to disposal or optionally for a new water supply line treated. / Neste trabalho foi avaliada a qualidade da água de lavagem de filtros e de lodo de decantador da Estação de Tratamento de Água Bom Jardim, localizada na cidade de Uberlândia-MG, após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração, todos em escala de bancada. Foram avaliados efluentes de leitos de drenagem compostos de três tipos de mantas geotêxteis distintas: RT-21, RT-26 e RT-31, e testados três tipos de granulometria de areia constituintes dos filtros. O efluente drenado, após passagem pelo leito de drenagem, passava pela unidade de flotação por ar dissolvido e em seguida pelas unidades de filtração. Foram realizados testes preliminares com amostra bruta da água de lavagem de filtros e de lodo de decantador, com o objetivo de caracterizá-la e avaliá-la quanto as suas características físicas, químicas e biológicas. As mantas geotêxteis utilizadas foram escolhidas a partir de resultados de trabalhos anteriores, realizados com o mesmo tipo de sistema. Os experimentos foram divididos nas etapas, I e II. Na etapa I foram conduzidos experimentos sem adição de agente coagulante ou auxiliares na coagulação/floculação da flotação. As amostras, após passagem pelo sistema, foram avaliadas quanto aos parâmetros físicos pH, turbidez, cor verdadeira e cor aparente e quanto aos parâmetros químicos, concentrações remanescentes de Alumínio e Ferro. Na etapa II foram realizados os mesmos ensaios da etapa I e mesmas determinações dos parâmetros de qualidade, entretanto, com dosagem de sulfato de alumínio de 5, 10 e 15 mg/L na coagulação/floculação da flotação. Os ensaios conduzidos na etapa I que mostraram melhor desempenho foram os realizados com a manta RT-26 na saída do Filtro 01 com redução de 91,8% da cor aparente, 41,4% da cor verdadeira e 97,6% da turbidez. Nos ensaios conduzidos na etapa II o melhor desempenho foi com o drenado da manta RT-26 na saída do Filtro 02 quando submetido a uma dosagem de 15 mg/L de sulfato de alumínio, como agente coagulante. Houve redução de 96,4% da cor aparente, 86,2% da cor verdadeira e 99,6% da turbidez. Os resultados apresentados confirmam a eficiência do sistema na remoção de sólidos presentes na água de lavagem de filtros e de lodo de decantador da ETA estudada, e confirmam a potencialidade de utilização deste sistema como alternativa ao descarte e como opção de nova linha de fornecimento de água tratada. / Mestre em Engenharia Civil
59

Utvärdering av geotextildukar för tillfällig sedimentkontroll : Avseende suspenderat material, PAH samt kvicksilver

Emma, Risén January 2010 (has links)
Geotextildukar används idag som tillfällig kontroll av sedimentgrumling vid vattenarbeten. Syftet med examensarbetet är att ge ökad kunskap kring olika geotextildukars genomsläpplighet med avseende på suspenderat material, PAH (Polycykliska aromatiska kolväten) och kvicksilver vid suspension av sediment från Karlbergskanalen. Detta har gjorts genom en laboration. Resultaten visar att det inom några minuter bildas en filterkaka på de tre undersökta dukarna. Dukarna blir täta då de utsätts för finpartikulärt suspenderat sediment med koncentrationen 57 g/l hämtat från Karlbergskanalen. Under de 2,5 timmar långa försöken har dukarnas permeabilitet kraftigt reducerats. Under laborationen var PAHtot och mängden PAH i den filtrerade fraktionen störst vid turbiditetsmaximum. Den filtrerade fraktionen PAH följde turbiditeten och reducerades med 21 % samtidigt som turbiditeten reducerades med 24 % under försöket. Även den totala kvicksilvermängden var störst vid turbiditetsmaximum, resultaten är dock inte statistiskt säkerställda. Under laborationen gav en högre halt suspenderat material en lägre andel PAH i den filtrerade fraktionen, troligtvis beroende på re-adsorption. För att utvärdera hur stor andel av PAH, kvicksilver, kadmium och koppar som befinner sig i den filtrerade fasen har det genomförts försök där sediment och vatten skakats 3x10 timmar. Av den totala PAH koncentrationen var 0,07 % i den lösta fasen. Endast en låg andel av koppar, kadmium och kvicksilver återfanns i den lösta fasen (< 1 %). Trots den låga andelen i den filtrerade fraktionen skulle motsvarande haltökningar i Karlbergskanalen innebära halter långt över aktuella gränsvärden[1]i dukbassängen. Innan filterkakan bildats sker ingen reduktion av turbiditeten för två av de tre undersökta dukarna. Geotextilskärmarna förhindrar således ingen spridning av miljögifter utan bildningen av en filterkaka. Om filterkakan bildas och består i fält går inte att fastställa utifrån laborationen. [1]MKN MAC för löst Hg och Cd, Naturvårdsverkets föreslagna GV för löst Cu MKN MAC för den totala PAH koncentrationen / Geotextiles are used as temporary sediment controls in water during construction work. The aim of this project is to give background information to a cost effective control program and to increase the knowledge about geotextiles and their permeability for suspended sediment, PAH and Hg for a site specific sediment. Laboratory studies have been conducted in order to evaluate three geotextiles with regard to their ability to separate suspended sediment, PAH and Hg. The results show that a filter cake is formed. The textiles became clogged within a time period of 15 minutes and no sediment passed the textiles after this. A sediment concentration of 57 g/l was used. The separation of suspended particulate matter is 28-78 % and the textile with the greatest reduction capacity was the thinnest one. The separation of PAHtot was 79 %, meanwhile the average separation of suspended sediments was 78 %. The geotextile did not reduce the dissolved fraction of PAH. This fraction was larger on the outside suggesting that the concentration of suspended material was too low to re-adsorb the dissolved PAH. The turbidity decreased with 24 % during the experiment due to sedimentation, the dissolved fraction of PAH was reduced with 21 % during the same time period. The amount of Hgtot was largest at turbidity maximum. Laboratory experiments where sediment was shaken 3x10 hours with distilled water have also been conducted in order to evaluate the amounts of PAH, Hg, Cu and Cd that partition in the dissolved phase. 0, 07 % of the total amount of PAH was found in the filtered phase and only small fractions of Cu, Cd and Hg (< 1 %). Despite the small percentage in the filtered fractions the corresponding increase in Karlbergskanalen would result in concentrations well above maximum allowed concentrations[1]in the geotextile encircled area. There is no reduction of the turbidity before the filter cake is formed. It is not possible to draw any conclusions about the formation of a filter cake in field and if a formed filter cake would be broken by hydraulic forces or not. [1]MKN MAC for dissolved Hg and Cd, Swedish Environmental Protection Agency’s suggested limit value for dissolved Cu, MKN MAC for the total PAH concentration
60

Reducción de deflexiones en la base de pavimento flexible mediante el uso combinado de Geotextiles No Tejidos (GNT) y Base Macadam / Reduction of deflections at the base of the flexible pavement by using the combined use of now-woven geotextiles (NWG) and Macadam Base

Gallardo Quiroz, Angel Manuel, Lopez Cruz, Lizette Alessandra 04 May 2021 (has links)
Las deformaciones permanentes en las carreteras son las principales causas de daños a los pavimentos flexibles, especialmente en los que han sido construidos sobre suelos blandos saturados. La utilización de Geotextiles No Tejidos (GNT) en una Base Macadam, colocado de manera que envuelva todo el perímetro de la base, representa una solución para la gestión de daños de pavimentos, ya que, de manera vertical, reduce las deflexiones; mientras de manera horizontal, evita la migración de partículas finas para reducir el efecto de bombeo. Para comprobar esta hipótesis, se realizaron investigaciones con el fin de determinar los materiales a usar para optimizar el diseño del pavimento y los espesores finales de las capas; y ensayos a bases simuladas para hallar las deflexiones en un tramo reforzado con Geotextil y un tramo sin reforzar. La medición de las deflexiones se logró mediante el ensayo de Deflectometría liviana (LWD). Finalmente, se pudo hallar una diferencia porcentual de 25.25% entre ambos casos. / Permanent deformations in roads are the main causes of damage to flexible pavements, especially in those built on saturated soft soils. The use of Non-Woven Geotextiles (NWG) in a Macadam Base, placed in the way that it surrounds the entire perimeter of the base, represents a solution for the management of pavement damage, since vertically, it reduces deflections; while horizontally, it avoids the migration of fine particles to reduce the pumping effect. To verify this hypothesis, investigations were carried out in order to determine the materials to be used to optimize the design of the pavement and the final thicknesses of the layers; and simulated bases tests were made to find deflections in a section reinforced with Geotextile and another unreinforced section. Measurement of deflections was achieved by the Light Deflectometry (LWD) test. Finally, a percentage difference of 25.25% could be found between both cases. / Trabajo de investigación

Page generated in 0.0525 seconds