Goniofotometr / GoniophotometerIvor, Martin January 2020 (has links)
The thesis deals with the design of a goniophotometer and the GUI (Graphical User Interface), capable of evaluating the photometric parameters of light sources and luminaires. The introduction contains theoretical information about photometry, photometric parameters, light sources, lamps, as well as the theory of measuring these parameters, and basic globally used data formats, designed to store the parameters of light sources. The core of this thesis, then describes the hardware, that makes up the proposed device, and the software needed to control the measurement process, visualization and storing the results. The conclusion is an evaluation of the functionality of the described device, and the measurements that were mediated by it, and an overall summary of the results achieved.
|
2 |
Jasové skenování svítidel a světelných zdrojů / Luminance scanning of luminaires and light sourcesŠevčík, Ondřej January 2013 (has links)
Práce se zabývá měřením křivek svítivosti světelných zdrojů a svítidel konvenčními a nekonvenčními metodami. Úvodní část práce je věnována popisu zrakového systému a základních fotometrických veličin. Hlavní teoretická část je zaměřena na popis současných metod měření křivek svítivosti a nových metod měření pomocí jasového analyzátoru. Současně jsou pro jednotlivé metody uvedeny zdroje nejistot, které ovlivňují výsledky měření. Těžiště práce spočívá v návrhu metodiky měření křivek svítivosti z jasových skenů svítidla a následném ověření tohoto postupu vlastním měřením. Dále bylo provedeno srovnání naměřených výsledků navrženým postupem, s výsledky konvenčního měření na goniofotometru s luxmetrem.
|
3 |
Blízká fotometrie / Near-field photometryKutý, Tomáš January 2015 (has links)
This thesis is focused on the theoretical and practical introduction to the verification procedures used today for obtaining luminosity curves of lamps. The introduction acquaints readers with the photometric variables. Consequently, it is theoretically described procedure for constructing luminance curves by zonal flow and further familiarization with the near-field photometry. For the practical part was chosen several lights. These lamps were measured by luxmeter first from a very close photometric distance from lights, and then from large distance. The next step was to obtain pictures of luminaries in planes C 0 to 345 ° (with a step of 15 °) of the angle gamma from 0 to 180 ° (in steps of 5 °). The measured data were processed by zonal flow and through programs LumiDISP and Matlab. The partial result of this thesis is to verify whether it is possible to use the luminance analyzer for obtaining luminosity curves, it means, if the luminosity curve obtained through luminance analyzer will comply with the curves obtained through a luxmeter. Further work should ascertain the feasibility of acquired photographs lamps from a very close photometric distance could create luminosity curve for any location and distance from the observer to measured lamps.
|
Page generated in 0.0748 seconds