• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energy consumption strategy : an overview of district cooling and heating in Hong Kong /

Sung, Ka-leung. January 2001 (has links)
Thesis (M. Sc.)--University of Hong Kong, 2001. / Includes bibliographical references (leaves 67-69).
2

A study of the optional use of oil or gas as fuel at the University of Arizona heating plant

Dorsey, Julian, 1902- January 1934 (has links)
No description available.
3

A study covering services with estimated operating costs of V.P.I. heating and power plant for the fiscal year 1940-1941

Bock, Arthur E., Porter, George J., Freeman, Walter B. January 1940 (has links)
M.S.
4

A computer simulation and performance evaluation of the Virginia Tech steam heating system

Beard, Gordon Van Zandt January 1984 (has links)
A computer simulation program was developed to simulate the Virginia Tech low pressure steam heating system. Based on the total heat available to the buildings and the buildings' relative transmission heat losses, this program will determine the distribution of the heat produced by the steam plant and determine the conditions of the steam at the buildings and along the pipeline. The above distribution of heat consists of heat lost from the pipeline and heat delivered to the buildings. This program was used to perform a preliminary performance evaluation of the steam heating system during the 1983-84 heating season, and for the coldest day (12/24/83) and day of maximum steam load (2/29/84) in particular. During this heating season 2.397 x 10¹¹ Btu was delivered by the steam plant to the buildings. Also, about 3% of the total heat delivered by the steam plant was lost through the pipeline. To enhance the usefulness of this program two actions were recommended. First, the steam pipeline and the buildings should be instrumented to allow for verification of the program results. Second, in order to produce more accurate results the program's data should be based on more accurate measurements of the pipeline characteristics and the building heating loads. / Master of Science
5

Energy consumption strategy: an overview of district cooling and heating in Hong Kong

Sung, Ka-leung., 宋家樑. January 2001 (has links)
published_or_final_version / Environmental Management / Master / Master of Science in Environmental Management

Page generated in 0.184 seconds