1

Modelo de despacho otimo com tratamento individual de unidade geradoras em usinas hidreletricas / Optimal dispach model with indivual

Colnago, Glauber Renato 02 February 2007 (has links)
Orientador: Paulo de Barros Correia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-09T13:14:43Z (GMT). No. of bitstreams: 1 Colnago_GlauberRenato_M.pdf: 2199430 bytes, checksum: a29163d68691a2b1bec8be6c8bf1d470 (MD5) Previous issue date: 2007 / Resumo: Os modelos de despacho ótimo atuais em usinas hidrelétricas (UHEs) são realizados tendo em conta as eficiências das unidades geradoras (UGs) obtidos com a extrapolação dos dados de um modelo em escala reduzida das turbinas. Uma extrapolação dos dados do modelo para o protótipo realizada com grande precisão poderia ser feita se houvesse semelhança dinâmica, geométrica e cinemática entre eles. Como isto é impossível, os fabricantes de turbinas possuem relações empíricas para corrigir as eficiências medidas no modelo para refletirem melhor o desempenho do protótipo. Apesar desta correção, o desempenho real das turbinas pode ser afetado por características construtivas ou operacionais das UHEs, não levadas em conta pelos fabricantes, e pode variar com o tempo de uso de uma forma diferente para cada UG de uma UHE. Logo, as eficiências das turbinas reais não são iguais às eficiências extrapoladas do modelo em escala reduzida e, sob esta ótica, um modelo de despacho realizado com as curvas de eficiência derivadas do modelo reduzido provavelmente não otimiza a eficiência de uma UHE. Pode-se obter dados de eficiência mais precisos (atualizados) das UGs instaladas com o auxílio de métodos de medição de vazão da água nos condutos forçados das UGs. Neste trabalho foi desenvolvido um modelo de despacho ótimo em UGs de UHEs que trata individualmente as UGs, pois as mesmas possuem, provavelmente, curvas diferentes quando se trata dos dados atualizados. A formulação matemática do modelo de despacho ótimo proposto é não linear inteiro misto e não convexo e foi utilizado o programa Lingo 8.0 para sua resolução, com buscas global e local. Os melhores resultados foram obtidos com a busca global. Foi realizado o despacho com os dois tipos de dados, os derivados do modelo reduzido e os atualizados de uma UHE real. Na simulação com dados atualizados chegou-se a ganhos entre 0,34% até 0,99% na operação da UHE, em comparação com a simulação com os dados derivados do modelo reduzido. Estas quantias significam, em valores monetários, entre R$ 700 mil e R$ 2 milhões anuais (para R$ 50/MWh). Os custos para a obtenção dos dados atualizados no caso em estudo foi quase nulo, no entanto, mesmo que utilizados métodosmais precisos para medição de vazão, que possuem um custo associado, este trabalho indica uma relação baixo custo e alto benefício para a utilização dos dados atualizados obtendo-se o retorno em poucos meses do capital investido / Abstract: Currently used models for optimal dispatch in hydro plants (HP) are based on generation units (GU) efficiency extrapolated from the reduced scale turbine data. An extrapolation from the reduced model data to obtaining real prototype data with excellent precision could occur only if dynamical, geometrical and kinematical similarity between prototype and reduced model would exist. As this is impossible, turbine manufacturers use empirical relations to correct model efficiency in order to reflect in a better way the prototype efficiency. Despite this correction, the turbines¿ real performance can be affected by HPs¿ constructive and operational characteristics, not taken into account by manufacturers; therefore, the real turbine efficiency in a specific GU is not similar to the one obtained from the reduced model by means of extrapolation. Considering this, optimal dispatch using extrapolated reduced model¿s efficiency data will probably not optimize the HP¿s efficiency. More exact efficiency data from the installed GU¿s can be obtained by means of water discharge measurements in penstocks. There was developed a dispatch model in GUs of HPs that treat GUs individually because, probably, their efficiency curves are different. The proposed dispatch model is a mixed integer nonlinear mathematical formulation. The software used to solve the problem was Lingo 8.0, with global and local searchs. Better results were obtained when using global search. This work presents a simulation of optimal dispatch using both kind of data: the extrapolated from the reduced model, and the more detailed data. The simulation that uses the more detailed data from a real HP permitted a gain between 0.34 and 0.99% compared to the one that uses reduced scale model data. These amounts, converted to monetary values, represent between R$700 thousand and R$2 million per year (for a tariff of 50 R$/MWh). The costs for obtaining the more detailed data used in this work are almost null. This work shows the introduction of more precise measurement techniques in GUs implies investments that can rapidly returned. / Mestrado / Mestre em Planejamento de Sistemas Energéticos
2

Aplicação do teste de "Impairment" em ativo imobilizado: estudo de impacto econômico decorrente da aplicação em uma "CGH" - Central Geradora Hidrelétrica

Canivezi , Evandro Rossi 15 December 2016 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2017-01-10T11:33:44Z No. of bitstreams: 1 Evandro Rossi Canivezi.pdf: 3144731 bytes, checksum: 57b161426a9189d67735d8539d80cceb (MD5) / Made available in DSpace on 2017-01-10T11:33:44Z (GMT). No. of bitstreams: 1 Evandro Rossi Canivezi.pdf: 3144731 bytes, checksum: 57b161426a9189d67735d8539d80cceb (MD5) Previous issue date: 2017-12-15 / The present work refers to the application of the "Impairment test" in a CGH - Hydroelectric Generating Center and aims to understand the condition of this asset, demonstrating the benefit that will be generated by this. The specific objectives of this research include adjusting this fixed asset to its real future economic return capacity, ascertaining that this asset is not recorded in the accounting for a value higher than that recoverable and analyzing whether the book value was recovered or if it is recovered Overvalued, subject to the recognition of losses. The research methodologies used in this work were qualitative and quantitative analysis, besides a case study. The study focuses on two research methodologies regarding the procedures, being carried out research and survey of the information pertinent to the universe to be researched. For the application of the "Impairment test", the amounts presented in the balance sheet and other information provided by the management area of the entity were considered. In the topic "analyzes and discussions", it is possible to observe the impacts, the form of elaboration and disclosure by the organizations and the comments related to this methodology / O presente trabalho refere-se à aplicação do “Impairment Test” em uma CGH - Central Geradora Hidrelétrica e visa compreender a condição deste ativo, demonstrando o benefício que será gerado por este. Os objetivos específicos desta pesquisa compreendem adequar este determinado ativo imobilizado a sua real capacidade de retorno econômico futuro, averiguar que este ativo não esteja registrado contabilmente por um valor superior àquele passível de ser recuperado e analisar se o valor contábil foi recuperado ou se o mesmo se encontra superavaliado, sujeitando-se o ativo ao reconhecimento de perdas. As metodologias de pesquisa utilizadas neste trabalho foram análise qualitativa e quantitativa, além de estudo de caso. Enquadram-se no estudo, duas metodologias de pesquisa quanto aos procedimentos, sendo realizadas pesquisa e levantamento das informações pertinentes ao universo a ser pesquisado. Para aplicação do “Impairment Test”, foram considerados os valores apresentados no Balanço Patrimonial e demais informações fornecidas pela área de gestão da entidade. No tópico “análises e discussões”, é possível observar os impactos, a forma de elaboração e disclosure por parte das organizações e comentários relacionados a essa metodologia
3

Contributions to the Methodologies and Technologies for the Intelligent Control-Maintenance-technical Management Systems (ICMMS) in Hydropower Plants

LIU, Yongqian 18 April 2002 (has links) (PDF)
Les travaux présentés contribuent à un des enjeux majeurs de l'Entreprise Etendue liée au domaine de la production d'énergie électrique. L'objectif est de maintenir en dynamique la qualité des services rendus par les processus de production. Ces travaux ont ainsi pour objet, en se référant au cadre de modélisation d'Entreprise GERAM, de proposer une méthodologie réutilisable pour l'automatisation intégrée des centrales hydroélectriques. Ces dernières étant structurellement des systèmes stables, cette méthodologie est basée sur une approche orientée processus et aboutit au développement de modèles pérennes et réutilisables. Le point central de cette méthodologie consiste en la définition d'un modèle de référence ICMMS (Intelligent Control-Maintenance-technical Management Systems) formalisant la connaissance générique, de niveau terrain, applicable à l'automatisation de toute centrale hydroélectrique. La mise en œuvre de ce modèle de référence conduit à la proposition d'une architecture HSAS (Hybrid Smart Automation System) qui intègre en un tout cohérent sur les points de vue Contrôle, Maintenance et Gestion Technique, les différents composants d'automatisation distribués, supportés par des actionneurs, capteurs, ou contrôleurs conventionnels de niveau terrain. Par rapport à cette architecture, les concepts innovants de "Surveillance Conditionnelle" pour l'îlot Maintenance et d' "Atténuation de Perturbations" pour l'îlot Contrôle sont définis et étudiés afin d'être intégrés au système ICMMS. De plus, nous proposons, pour la Gestion Technique, des concepts, critères et outils pour l'évaluation de performances des HGUs (Hydroelectric Generating Units). Cette contribution est basée sur la définition d'un système d'évaluation des performances économiques utilisant des descripteurs quantitatifs mesurant l'état d'efficacité, le niveau de gestion de l'exploitation et l'état de maintenance de ces unités. Une nouvelle stratégie en lien avec la maintenance, intitulée EBM (Economic performance Based Maintenance), est ainsi formalisée. L'ensemble de nos propositions est validée sur une étude de cas.