• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Alternativ till perfluorerade impregneringar : Nya och hållbara materialkombinationer

Larsson, Felicia, Benjaminsson, Louise January 2016 (has links)
Kläder som är avsedda för friluftsaktiviteter bör vara vattenavvisande. För att plaggen ska erhålla vattenavvisande egenskaper krävs att textilen är impregnerad med en vattenavvisande kemikalie. Kemikalierna som används för detta idag är ofta baserade på högfluorerade ämnen, så kallade fluorkarboner. Dessa typer av kemikalier kan brytas ned till substanser som är skadliga för människor och natur. Efterfrågan på vattenavvisande impregneringar som inte är baserade på högfluorerade ämnen ökar i takt med en ökad medvetenhet om hållbarhets- och miljöfrågor. Trots att det utvecklas allt fler alternativa impregneringar till fluorkarboner erhåller dessa inte samma höga prestanda som de högfluorerade ämnena. Detta arbete är ett uppdrag från Houdini Sportswear som är ett svenskt företag som utvecklar högpresterande friluftskläder. Företaget vill hitta ett alternativ till de högfluorerade ämnena för de skalplagg de producerar. I detta arbete har författarna undersökt om olika mikro-och makroskopiska strukturer kan öka en impregnerad textils hydrofobicitet. Textilerna som har använts i undersökningen är fyra vävar av 100 % kemiskt återvunnen polyester med olika bindningar, dTex och egenskaper. På Textilhögskolan i Borås har samtliga vävar impregnerats med två olika impregneringar, - en baserad på dendrimerer och en baserad på paraffinvax. För att bestämma hur de olika vävarnas hydrofobicitet skiljer sig åt har kontaktvinkeltest genomförts. Det var också relevant att undersöka hur strukturerna och de vattenavvisande egenskaperna påverkades av en simulerad användning eftersom att friluftskläder slits under sin livstid. Resultaten visade på att det fanns en signifikant skillnad mellan de vattenavvisande egenskaperna för de olika vävarna. Undersökningen har resulterat i slutsatsen att mikro- och makroskopiska strukturer påverkar en vävs vattenavvisning. Dock har inte några definitiva slutsatser om vilka strukturella parametrar det är som påverkar de vattenavvisande egenskaperna kunnat dras. Resultatet från statistiska test visade inte på en signifikant skillnad mellan vävarnas vattenvisande egenskaper före och efter en simulerad för en av impregneringarna medan tester för den andra impregneringen visade på en signifikant skillnad efter en simulering, dock blev vattenavvisningen till det bättre. Därav kunde slutsatsen dras att vattenavvisningen består även efter att vävarna blivit tvättade och nötta.
2

Unspecific interactions in different batch variations of agarose based base matrices at different NaCl concentrations.

Ghofranpanah, Kejvan January 2022 (has links)
Size exclusion chromatography (SEC) separates molecules based on their actual size rather than their molecular weight. This indicates that the smaller a molecule is, the longer it will be held in the column since it can penetrate the pores more effectively than a bigger molecule, resulting in a longer retention time, whereas the larger molecule has a shorter retention time. In order to achieve reliable and accurate results the asymmetry factor of the packed columns should be between 0.6-1.4. The aim for this project was to examine whether or not the batch variations of the base matrix used to derive WorkBeads™ 40S and 40Q displayed either hydrophobic or hydrophilic interactions by running different types of proteins through columns packed with the base matrices. The project was performed using an ÄKTA explorer equipped with an ultraviolet (UV) detector and a refractive index detector (RID). The data was gathered and analyzed with the Unicorn™ by Cytiva. The results from the first experiments showed that lysozyme did not elute as expected or not at all, thus leading to a concern that the there might be some hydrophobic interactions in the base matrix, which is a porous media in the form of spherical particles that have been selected for their physical stability and inertness (lack of reactivity and adsorptive properties), and lysozyme. With this suspicion in mind, the different batches of the base matrix underwent hydrophobic interaction chromatography (HIC), where the results may be interpreted in a way that there might electrostatic interactions instead of hydrophobic interactions. However, due to the gel not being suitable for HIC the results were unreliable. By subsequently running lysozyme and other proteins through the columns at different NaCl concentrations the results showed consistent elution at NaCl concentrations > 150 mM, yet inconsistent at a concentration of 150 mM for lysozyme. The elution order by size showed that although lysozyme has a larger hydrodynamic radius (Rh) than cytochrome c it eluted later, which is theoretically incorrect, but it might be owing to some of the base matrix's characteristics or the lysozyme's dual nature of expressing both hydrophobic and hydrophilic interactions on the base matrix. Because of the inconsistent results from lysozyme, another experiment just at 150 mM was conducted where lysozyme did elute consistently with a KD value < 1.  Lastly, a titration was performed on the base matrix where some of it was brominated and some of it was not, which was the reference. The results showed that there could be hydrophobic interactions on the brominated sample and hydrophilic interactions on the reference sample. However, what is more likely is that lysozyme is an unreliable protein to use to determine hydrophobicity on this type of gel. / Size exclusion chromatography (SEC) separerar molekyler baserat på deras faktiska storlek snarare än deras molekylvikt. Detta indikerar att ju mindre en molekyl är, desto längre kommer den att hållas i kolonnen eftersom den kan tränga sig in i porerna mer effektivt än en större molekyl, vilket resulterar i en längre retentionstid, medan den större molekylen har en kortare retentionstid. För att uppnå tillförlitliga och nogranna resultat bör asymmetrifaktorn hos de packade kolonnerna vara mellan 0.6-1.4. Syftet med detta projekt var att undersöka huruvida batchvariationerna av basmatrisen som användes för att ta fram WorkBeads™ 40S och 40Q uppvisade antingen hydrofoba eller hydrofila interaktioner genom att köra olika typer av proteiner genom kolumner packade med basmatriserna. Projektet utfördes med en ÄKTA explorer utrustad med en ultraviolett (UV) detektor och en refractive index detector (RID). Data samlades in och analyserades med Unicorn™ av Cytiva. Resultaten från de första experimenten visade att lysozym inte eluerade som förväntat eller inte alls, vilket ledde till en oro för att det kan finnas vissa hydrofoba interaktioner i basmatrisen, som är ett poröst medium i form av sfäriska partiklar som har har valts ut för deras fysikaliska stabilitet och inerthet (brist på reaktivitet och adsorptiva egenskaper), och lysozym. Med denna misstanke i åtanke genomgick de olika bactherna av basmatrisen hydrofob interaktionskromatografi (HIC), där resultaten kan tolkas på ett sätt att det kan förekomma elektrostatiska interaktioner istället för hydrofoba interaktioner. Men på grund av att gelen inte var lämplig för HIC var resultaten opålitliga. Genom att efteråt köra lysozym och andra proteiner genom kolonnerna vid olika NaCl-koncentrationer visade resultaten konsekvent eluering vid NaCl-koncentrationer > 150 mM, men ändå inkonsekventa vid en koncentration av 150 mM för lysozym. Elueringsordningen efter storlek visade att även om lysozym har en större hydrodynamisk radie (Rh) än cytokrom c, eluerade det senare, vilket är teoretiskt inkorrekt, men det kan bero på några av basmatrisens egenskaper eller lysozymets dubbla natur att uttrycka både hydrofoba och hydrofila interaktioner på basmatrisen. På grund av de inkonsekventa resultaten från lysozym, utfördes ett annat experiment enbart vid 150 mM där lysozym eluerade konsekvent med ett KD-värde < 1. Slutligen utfördes en titrering på basmatrisen där en del av den var bromerad och en del av den inte, vilket var referensen. Resultaten visade att det kunde finnas hydrofoba interaktioner på det bromerade provet och hydrofila interaktioner på referensprovet. Men vad som är mer troligt är att lysozym är ett opålitligt protein att använda för att bestämma hydrofobicitet på denna typ av gel.

Page generated in 0.0341 seconds