Spelling suggestions: "subject:"impressa -"" "subject:"impressas -""
1 |
Análise e desenvolvimento de um sistema impressor Raster de formato extra-largoBurgoa, David Guillermo Pimentel January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-21T12:34:15Z (GMT). No. of bitstreams: 1
237362.pdf: 7940045 bytes, checksum: ce6a13c7bf842722f9f97aad24aa35be (MD5) / O presente trabalho visa contribuir para o desenvolvimento de sistemas de impressão, apresentando uma proposta de análise de dispositivos para impressão e desenvolvendo um sistema impressor raster de formato extra-largo, necessidade especial e atual das micro e pequenas empresas de comunicação visual. Destina-se a realizar impressões de mídias sem emendas, na ordem dos metros (3,5m de boca), com resolução adequada (menor) para visualização acima dos 6 m possibilitando maiores velocidades de impressão, de até 40 m2/h e a menor custo.
Devido a sua concepção com base vazada pode imprimir através do plano de base diretamente sobre a superfície final, o que permite realizar impressões tanto sobre superfícies rígidas como filmes flexíveis (papel, plástico, lona, etc).
O protótipo do sistema impressor proposto consta de três principais módulos: O módulo de pós-processamento que realiza a leitura da informação de impressão, condiciona os sinais e gera os comandos específicos que atuam nos sistemas de acionamento localizados no segundo módulo, o conjunto impressor, estes comandos movimentam adequadamente os eixos do pórtico X-Y para que o terceiro módulo, o cabeçote impressor, realize a impressão propriamente dita ao comando de sinais elétricos.
A leitura da informação de impressão, cor e sua posição x,y no desenho para cada ponto, foi implementada no módulo de pós-processamento utilizando dois métodos, um via hardware utilizando a informação existente numa impressora comum durante seu funcionamento e outro via software diretamente do gráfico a ser impresso.
Com o objetivo de melhor conhecer e otimizar a resposta dinâmica do conjunto impressor, os dois eixos de movimento da máquina foram modelados obtendo suas funções de transferência. A simulação destas funções permite conhecer seu comportamento e conseguir um ajuste adequado dos parâmetros de controle da placa controladora de movimentos. Após todos estes processos, foram realizados com o conjunto impressor vários ensaios de resposta no tempo para posicionamento e trajetória, até atingir o comportamento especificado.
O software gerenciador projetado integra todos estes sub-sistemas e comanda o funcionamento do protótipo impressor desenvolvido. Com o sistema funcionando realizaram-se testes de qualificação de impressão em formato extra-largo, os quais já atendem satisfatoriamente as exigências impostas. Atualmente o protótipo desenvolvido encontra-se em fase experimental e de otimização de funcionamento.
This research work is a contribution to design printing systems, presenting a proposal in order to analyze devices and to develop a raster printer system having extra-large format, specially and update need by visual communication enterprises, having small and medium size.
Such printing system is intended for print large-scale images within the range of 3,5 meters of mouth with adequate resolution (smaller) for visualization above 6 meters supporting printing velocities up to 40 m2/h and lower cost.
Due to its conception it is able to print directly through its base plan on the final surface, allowing printing on rigid surfaces as well as on flexible films (papers, plastic, canvas etc#)
The prototype of the proposed printing system has three main modules:
The post-processing module reads the information to be printed, sets the signals and generates the specific commands that actuate on the specific drives placed on the second module. The printing head in the third module follows the program feeding the drives of the x - y gantry in order to do the printing movements.
The reading of the printing color and x - y position informations for each point in the drawing has been implemented in the post-processing module using two methods, one by hardware, using an existing information in a standard printer in use, and another way, directly from the printing graphics file.
For to better know how to optimize the dynamic behavior of the printing system the two motion axis have been modeled in order to get its transfer functions. The simulation of this functions allows to know its behavior in order to help obtain an adequate values set of the parameters of the motion controller. After these procedures, systematic time measurements helped to match the given specifications.
The main implemented system software integrates all these sub-systems and commands the printer machine. Qualifying printing tests using extra-large format show that the system supports well the imposed requirements. Right now the developed prototype is in experimental tests aiming optimization.
|
2 |
Desinfecção de alginatoMeira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
|
3 |
Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized waterPaulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
|
4 |
Desinfecção de alginatoMeira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
|
5 |
Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized waterPaulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
|
6 |
Desinfecção de alginatoMeira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
|
7 |
Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized waterPaulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
|
8 |
[pt] DESENVOLVIMENTO DE LIGAÇÕES VIGA-COLUNA DE PERFIS PULTRUDADOS POR MEIO DA MANUFATURA ADITIVA / [en] DEVELOPMENT OF BEAM-TO-COLUMN JOINTS FOR PULTRUDED PROFILES USING ADDITIVE MANUFACTURINGJESSE HENRIQUE NASCIMENTO BESERRA 11 April 2022 (has links)
[pt] O presente trabalho propõe um novo tipo de ligação entre perfis pultrudados que
não exija furação do material, seja leve e fabricado por manufatura aditiva. Para
isso, fez-se uma revisão do estado da arte no âmbito das ligações entre perfis de
compósitos, abordando ligações parafusadas simples, cujos parafusos estão sujeitos
apenas ao corte, bem como as ligações semirrígidas, que são menos contempladas
pela literatura atual. Além disso, tratou-se do uso de otimização topológica em
componentes mecânicos voltados à impressão 3D. Posteriormente, define-se a
geometria básica do componente proposto e o respectivo modelo numérico adotado
no processo de otimização topológica, expondo todas as condições de contorno,
carregamento e otimização. A fim de verificar experimentalmente o
comportamento do componente apresentado, ensaios momento-rotação foram
realizados em três grupos, sendo um composto por exemplares com a geometria
original básica e os demais por componentes otimizados (com e sem reforço). Por
fim, foi observado que o caminho de fibras estabelecido foi coerente com as
solicitações às quais o componente está submetido, haja vista a maior eficiência
manifestada pelo aumento de resistência e rigidez por unidade de massa. A mesma
constatação se aplica ao processo de otimização e ajuste. No mais, a utilização do
reforço com fibras implicou numa maior repetibilidade na resposta mecânica da
ligação. / [en] The current work proposes a new type of joint between pultruded profiles that
does not require drilling, is lightweight and build by additive manufacturing. To
accomplish that, a state of art review on pultruded profiles joints was carried,
addressing simple bolted joints which have their bolts only subjected to shear, as
well as semi-rigid joints. Besides, the use of topology optimization on 3D-printed
mechanical components is also addressed. Posteriorly, the basic geometry of the
proposed component is defined and its respective numeric model used within the
topology optimization, presenting their boundary, load and optimization conditions.
In order to experimentally verify the behaviour of the component, moment-rotation
tests were carried in three groups, namely, the original geometry group, the simple
optimized group and the reinforced optimized group. In the end, it was observed
that the defined fibre path is consistent with the stresses acting within the
component, regarding the greatest efficiency shown in terms of strength and
stiffness per unit mass for the reinforced specimens. The same applies to the
optimization and adjusting processes. Furthermore, the use of fibre reinforcement
led to a greater repeatability of mechanical response.
|
9 |
[en] PHYSICAL -CHEMICAL EVALUATION OF HIGH DENSITY POLYETHYLENE PROCESSED BY THE 3D PRINTING METHOD OF FUSED DEPOSITION MODELING FDM / [pt] AVALIAÇÃO FÍSICO-QUÍMICA DO POLIETILENO DE ALTA DENSIDADE PROCESSADO PELO MÉTODO DE IMPRESSÃO 3D POR MODELAGEM POR FUSÃO E DEPOSIÇÃO FDMDANNY MESIAS CHAVEZ NOVOA 17 April 2015 (has links)
[pt] O objetivo deste trabalho foi estudar a influencia das condições da impressão 3D nas propriedades finais do polietileno de alta densidade usando a modelagem por fusão e deposição, FDM. Foram impressos protótipos com formato de corpos de prova para teste de tração tipo V segundo norma ASTM D638, a três temperaturas de processamento: 220, 240 e 260 Graus Celsius. Para a impressão das amostras foram mantidos constantes os parâmetros de controle, entre eles a espessura da camada de impressão. As amostras impressas foram caracterizadas por difração de raios X, espectroscopia infravermelha, calorimetria diferencial de varredura, análise termogravimétrica, ensaio de tração, índice de fluidez e teste de contração. Os resultados das caracterizações das amostras impressas foram comparados com os resultados do material sem processar, cujas propriedades foram obtidas usando os mesmo métodos de caracterização. Estes resultados demostraram que as condições de impressão por FDM empregadas neste trabalho causaram apenas uma leve mudança nas características estruturais das amostras processadas do PEAD em relação ao material original sem processamento. Houve um leve aumento da cristalinidade no PEAD impresso (em torno de 1,3 a 3 porcento). Além disso, foi comprovado que por causa do resfriamento desigual na superfície e no interior da amostra impressa, o grau de cristalinidade foi levemente maior no interior que na superfície do corpo de prova impresso. A leve mudança no grau de cristalinidade não foi suficiente para causar mudança no módulo de elasticidade e no limite de escoamento em relação ao PEAD original. Outros resultados demostraram que não houve mudança significativa envolvendo formação de ligações duplas, quebra de cadeias e degradação térmica por efeito da condição do processamento utilizada durante a impressão. / [en] The aim of this work was to study the influence of process conditions for 3D printing on the final properties of prototypes of high density polyethylene (HDPE) using the method of the fused deposition modeling. Prototypes for type-V tensile testing according to ASTM D 638 were printed; They were made to three processing temperatures: 220, 240 and 260 Celsius degree. Control parameters for printing were kept constant in all the samples. The printed samples were characterized by X – ray diffraction, infrared spectroscopy, thermogravimetric analysis, differential scanning calorimetry, tensile test, melt flow index test, and, shrinkage test. The results of the characterization of the printed samples and of the original material were compared. These results demonstrated that the printing conditions employed in this study caused a slight change in the structural characteristics of the printed samples compared to the unprocessed original material, there being a slight increase in crystallinity (about 1,3 to 3 percent) for HDPE which was printed. In addition, it has been proven that the degree of crystallinity was slightly greater on the inside that on the surface of the printed samples, because of uneven cooling on the surface and inside of these samples. The slight change in the degree of crystallinity was not enough to cause change in the elastic modulus and yield strength compared to the original HDPE. Other results showed that there was not significant change involving bond formation, break chains, and, thermal degradation by the effect of the processing conditions used during printing.
|
10 |
[en] FACEWORK VIA E-MAIL: STRATEGIC INTERACTION IN DISTANCE EDUCATION / [pt] FACEWORK VIA E-MAIL: INTERAÇÃO ESTRATÉGICA NO ENSINO A DISTÂNCIAELIZABETH VARGES DE SOUZA 26 September 2013 (has links)
[pt] A educação a distância mediada pelo computador proporciona variadas
formas de interação. Os cursos oferecidos nesta modalidade diferem tanto
conceitual quanto metodologicamente no que concerne sua elaboração,
implementação e aperfeiçoamento. Porém, aparentemente, tais questões não são o
calcanhar-de-aquiles da EaD, posto que muito tem sido estudado e debatido sobre
o processo de aprender a aprender, o desenvolvimento da autonomia do aluno, o
trabalho colaborativo e o papel do professor neste novo ambiente. A
transformação realmente significativa após a inserção das tecnologias da
comunicação e da informação no cenário educacional se deu na forma de se
comunicar e de interagir, posto que foi a crescente facilidade de acesso à Internet,
juntamente com o desenvolvimento de aplicativos e diferentes ambientes de
aprendizado online, o que possibilitou novas e diversificadas formas de interação,
ampliando o leque de possibilidades de comunicação. Portanto, é a partir de
questionamentos acerca de como os processos interacionais ocorrem no ambiente
institucional online e como as pessoas, no caso desta pesquisa, os alunos,
negociam significados e constituem suas posições sociais é que trarão uma nova
perspectiva de entendimento da aprendizagem mediada pelo computador. Assim,
tendo como suporte metodológico as questões de face e do manejo da impressão
de Goffman, aliados aos pressupostos da sociolinguística interacional, como as
pistas de contextualização e o footing dos interagentes, é que procedo às análises
do conteúdo dos e-mails trocados entre alunos e mediadora, levando em
consideração que as interações devem ser compreendidas dentro das limitações
impostas pela tecnologia. Assim sendo, esta pesquisa objetivou, através de dois
tipos distintos de análise, uma formal e outra discursiva, contribuir para um
entendimento mais abrangente da utilização do e-mail tanto como um meio que possibilita atestar a dinamicidade das interações quanto compreender como
questões relacionadas à face emergem e podem exercer um papel crucial no
ensino-aprendizagem a distância. / [en] Distance education mediated by computers provides several forms of
interaction. The courses offered in this modality differ both conceptually and
methodologically in what regards its design, implementation and improvement.
However, apparently, these issues are not the Achilles heel of DE, since much has
been studied and debated about the process of learning how to learn, the
development of learner’s autonomy, collaborative work and the teachers’ role in
this new environment. The technology available for studying online kind of
imposed this paradigm shift in teaching and learning at a distance, since it would
not be viable to adapt the traditional model of knowledge transmission to a type of
education that privilege autonomy and collaboration. However, the actual
meaningful change after the introduction of the information and communication
technologies in the educational scenario occurred in the way people interact, since
it was the increasing ease of Internet access, along with the development of
different applications and online learning environments that allowed new and
diverse forms of interaction, expanding the range of communication possibilities.
Therefore, it is based on questionings about how the interactional processes occur
in institutional environments online and how people, in the case of this research,
the students, negotiate meanings and constitute their social positions that a new
perspective to the understanding of computer mediated learning will arise. Thus,
based on Goffman’s concepts of facework and impression management, along
with those of interactional sociolinguistics, as for example, the contextualization
cues and the footing of the interactors, I proceed to the analysis of the content of
the e-mails exchanged between the students and the mediator, taking into account
that such interactions must be understood within the limitations imposed by
technology. Therefore, through two different types of analysis, a formal and a discursive one, this study aimed at contributing to a broader understanding of the
use of the e-mail not only as a way that provides the possibility to attest the
dynamics of the interactions throughout a course but also as a means to
understand how issues related to face emerge and may play a crucial role in
distance teaching and learning.
|
Page generated in 0.0508 seconds