• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Ribeiro, Luiz Fernando 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de µg L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 µg L-1 para o Cu(II), 1,4 e 4,6 µg L-1 para o Pb(II), 0,6 e 1,8 µg L-1 para o Cd(II) e 4,2 e 14 µg L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 µL, vazão de 10 µL s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 µL), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of µg L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 µg L-1 for Cu(II), 1.4 and 4.6 µg L-1 for Pb(II), 0.6 and 1.8 µg L-1 for Cd(II) and 4.2 and 14 µg L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 µL, flow rate of 10 µL s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 µL) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences
372

Maturação in vitro de oócitos de mulheres com síndrome dos ovários policísticos: comparação entre dois meios de cultivo / Oocytes In VitroMaturation of Women with Polycystic Ovarian Syndrome: Comparison Between Two Culture Medium

Araujo, Carlos Henrique Medeiros de 13 July 2007 (has links)
Objetivo:Comparar a eficácia dos meios de cultivo HTF (Human Tubal Fluid) e TCM 199 (Tissue Culture Medium) na maturação in vitro. Métodos:Estudo experimental controlado e randomizado no qual foram avaliadas as taxas de maturação oocitária, fertilização, clivagem e produção de embriões de boa qualidade em 23 ciclos não estimulados de maturação oocitária, com 119 oócitos coletados, de 13 mulheres com Síndrome dos Ovários Policísticos. Os oócitos de cada paciente foram transferidos randomicamente para cada um dos meios de cultivo sendo que, 61 (51%) foram colocados no meio TCM 199 e 58 (49%) no meio HTF. Os dois meios de cultivo receberam suplementação hormonal. Resultados:Diferenças significativas foram encontradas entre os meios de cultivo TCM 199 e HTF em relação à taxa de maturação oocitária (82% vs. 56.9%, p = 0.005), taxa de fertilização (70% vs. 39.4%, p = 0.007) e taxade produção de embriões de boa qualidade (81.3% vs. 41.7%, p= 0.023). Conclusão:O meio de cultivo HTF embora seja utilizado para manutenção de embriões em técnicas de fertilização assistida e em procedimentos de maturação in vitrocom ciclos estimulados, não é o meio mais apropriado paramaturação de oócitos obtidos de mulheres com Síndrome dos Ovários policísticosem ciclos não estimulados. / Objective:Compare oocytes human culture in human tubal fluid (HTF) and Tissue Culture Medium (TCM 199) invitromaturation cycles. Methods:Randomized controlled trial which oocyte maturation, fertilization, cleavage rates and embryo quality in 23 in vitromaturation cycles no stimulation were evaluated, resulting in 119 oocytes retrieved from 13 patients withpolycystic ovarian syndrome. The oocytes from each patient were assigned randomly to the two culture media, 61 (51%) to the TCM 199 and 58 (49%) to the HTF using the same hormonal supplementation. Results:Significant differences were observed between TCM 199 and HTF regarding maturation rate (82% vs. 56.9%, p = 0.005), fertilization rate (70% vs. 39.4%, p = 0.007) rates and embryo quality (81.3% vs. 41.7%, p= 0.023). Conclusion:The HTF medium, although widely employed for oocyte fertilization and embryo maintenance in IVF techniques, is not an appropriated medium to maturation oocytes obtained from PCOS patients innon - stimulated cycles.
373

Cromatografia a líquido por injeção sequencial para a determinação de herbicidas triazínicos e metabólitos da atrazina explorando o uso de cela de longo caminho óptico e monitoramento on-line em estudos de adsorção / Sequential injection liquid chromatography for the determination of triazine herbicides and metabolites of atrazine exploring the use of long optical pathlength flow cell and on line monitoring of adsorption studies

Urio, Ricardo de Prá 16 May 2011 (has links)
Estudou-se o emprego da Cromatografia a Líquido por Injeção Seqüencial (SIC) explorando o uso de uma cela de longo caminho óptico com guia de onda (LCW) de 100 cm para a melhora dos limites de detecção (LOD) e quantificação (LOQ) na determinação de atrazina (ATR), propazina (PRO) e simazina (SIM). Para isto, utilizou-se uma fase móvel com composição de 44:56 (v v-1) metanol : tampão acetato de amônio 1,25 mM, pH 4,7, coluna monolítica e a detecção espectrofotométrica em 238 nm. Obtiveram-se valores de LOD e LOQ, respectivamente, de 1,76 e 5,86 µg L-1 para ATR, 4,51 e 15 µg L-1 para PRO e 2,25 e 7,5 µg L-1 para SIM. Com o emprego da cela de longo caminho óptico os valores de LOD ficaram abaixo dos recomendados pela US-EPA, que permite para águas potáveis uma concentração de 3 µg L-1 para ATR, 4 µg L-1 para SIM e 10 µg L-1 para PRO. Realizaram-se estudos de adsorção de SIM, PRO e ATR e seus metabólitos desisopropilatrazina (DIA), desetilatrazina (DEA) e 2-hidroxiatrazina (HAT) em solo, ácido húmico e solo modificado com ácido húmico. Para isso foi utilizado um sistema de monitoramento on-line composto por um filtro tangencial e uma bomba peristáltica para circulação da suspensão. Foram realizados estudos cinéticos em duas etapas e, em ambas, foi utilizado um mix dos compostos com concentração inicial de 1,0 mg L-1 e gradiente de eluição passo a passo para a separação dos compostos utilizando três fases móveis com composições de 15 ou 28, 40 e 50% (v v-1) metanol : tampão acetato de amônio 1,25 mM pH 4,7. Na primeira etapa o tempo de contato entre triazinas e adsorventes foi de 90 min. Na segunda etapa foi utilizado apenas o solo como adsorvente e o tempo de contato foi de 24 h. Para a primeira etapa do estudo só foi possível aplicar modelo cinético de pseudo-segunda ordem, o qual permitiu estimar os valores de massa adsorvida de triazina por massa de adsorvente, sendo que o ácido húmico é o material com maior capacidade adsortiva (1470 ± 43µg g-1 para DIA a 2380 ± 51 µg g-1 para PRO). O composto mais adsorvido em solo é PRO (26,5 ± 0,1 µg g-1). A presença de ácido húmico no solo aumentou a adsorção de ATR (de 19,4 ± 0,7 para 23 ± 2 µg g-1), de HAT (10,9 ± 0,7 para 18 ± 2 µg g-1) e de PRO (26,5 ± 0,7 para 29,8 ±0,2 µg g-1), mas diminuiu a adsorção de SIM e não afetou DIA e DEA. No estudo com tempo de contato de 24 h foi possível aplicar modelos de pseudo-primeira e segunda ordem. Os resultados obtidos confirmaram a maior adsorção de PRO, seguidos da ATR. HAT, SIM, DEA e DIA apresentaram as menores taxas de adsorção em solo, sendo que os dois últimos apresentaram uma tendência de dessorção após 4 h de contato, tendo maior potencial de lixiviação para corpos d\'água próximos aos locais de aplicação. / This work describes the use of Sequential Injection Liquid Chromatography (SIC) coupled to a long path length optical flow cell with 100 cm long Liquid Core Waveguide (LCW) to improve the limits of detection (LOD) and quantification (LOQ) for determination of atrazine (ATR), propazine (PRO) and simazine (SIM). Separation was achieved with a mobile phase composition of 44:56 (v v-1) methanol:1.25 mM ammonium acetate buffer, pH 4.7, monolithic column and spectrophotometric detection at 238 nm. The values of LOD and LOQ were, respectively, 1.76 and 5.86 µg L-1 for ATR, 4.51 and 15 µg L-1 for PRO and 2.25 and 7.5 µg L-1 for SIM. The LOD values achieved with the employment of long optical path cell were lower than those recommended by US-EPA, which allows for drinking water, maximum concentration levels of 3 µg L-1 for ATR, 4 µg L-1 for SIM and 10 µg L-1 for PRO. Adsorption of SIM, PRO and ATR, as well as their metabolites desisopropylatrazine (DIA), desethylatrazine (DEA) and 2-hidroxyatrazine (HAT) on soil, humic acid and soil modified with humic acidic was studied. An on-line monitoring system was assembled, composed of a tangential filter and a peristaltic pump for circulation of the suspension. Kinetic studies were carried out in two steps, and in both, it was used a mix of compounds with initial concentration of 1,0 mg L-1 and a stepwise gradient elution for separation of the compounds using three mobile phases with compositions of 15 or 28, 40 and 50% (v v-1) methanol: 1.25 mM ammonium acetate buffer, pH 4.7. In the first step the contact time between triazines and adsorbents was 90 minutes. In a second study made only with soil, the contact time was 24 h. Data obtained in the first stage of the study was only fitted to pseudo-second order kinetic equation, which allowed one to estimate the values of the adsorbed mass of triazine per mass of adsorbent. Humic acid was the material with higher adsorptive capacity (from 1470 ± 43 µg g-1 for DIA to 2380 ± 50 µg g-1 for PRO). In soil, PRO exhibited the highest adsorption (26.5 ± 0.1 µg g-1). The presence of humic acid in the soil increased adsorption of ATR (19.4±0.7 to 23±2 µg g-1), HAT (10.9 ± 0.7 to 18 ± 2 µg g-1) and PRO (26.5 ± 0.7 to 29.8 ± 0.2 µg g-1), but decreased adsorption of SIM, not affecting DIA and DEA. In the study with contact time of 24 h, it was possible apply pseudo-first and pseudo-second order equations for SIM, ATR and PRO. The results confirmed the greatest adsorption of PRO, followed by ATR. HAT, SIM, DEA and DIA had low rates of adsorption on soil, the latter two showed a trend of desorption after 4 h of contact, having the greatest potential for leaching to water bodies near to the places of application.
374

Desenvolvimento de um gerenciador eletrônico para motores tricombustível. / Development of an electronic controller for tri-fuel engines.

Veiga, Michel Robert 10 September 2010 (has links)
O objetivo do desenvolvimento do projeto foi minimizar uma das principais desvantagens no uso do gás natural veicular, que é a perda de potência, e aumentar sua eficiência volumétrica através da construção de um circuito eletrônico capaz de gerenciar de forma eficiente a injeção do gás. O aumento do rendimento é obtido através do gerenciamento eficiente da mistura ar-combustível utilizando um sistema de malha fechada. O gerenciamento da relação de potência e economia é conseguido com o uso simultâneo de gás natural e o combustível líquido. Nos sistemas de conversão atuais e nos veículos originais a gás natural, a perda de potência é compensada desligando o sistema de gás e utilizando somente o combustível líquido, sendo esta seleção feita de forma manual na maioria dos sistemas de conversão e de forma automática no Fiat Siena tetrafuel, não possibilitando o uso simultâneo do gás com o combustível líquido. A exigência de potência é medida através do ângulo do pedal do acelerador. Quando a exigência de potência é baixa, o sistema opera apenas com gás. No momento em que há solicitação de potência intermediária, o sistema opera com diferentes proporções de etanol e gás. Na situação de solicitação de potência máxima, é utilizado apenas o combustível líquido. Foram feitas comparações entre o sistema convencional e o sistema proposto, através de ensaios dinamométricos, rodoviários e emissão de poluentes. O veículo Volkswagen Gol com seu sistema original utilizando somente etanol possui potência máxima de 64,06 cavalos, (47,77 Kilowatts) e consumo de 12,6 quilômetros por litro de etanol. Com o sistema convencional de gás natural aspirado, o consumo foi de 21 quilômetros por metro cúbico e a potência não ultrapassou 51,82 cavalos (38,64 Kilowatts), com o protótipo desenvolvido a eficiência volumétrica aumentou 25% com consumo de 26,4 quilômetros por metro cúbico. O gerenciamento de potência proporciona potências intermediárias acima de 51,82 cavalos (38,64 Kilowatts), até a potência máxima de 64,06 cavalos (47,77 Kilowatts) em situações que uma maior potência é requerida. O sistema desenvolvido proporciona o benefício da flexibilidade no abastecimento disponível nos sistemas atuais, com a flexibilidade na potência não disponível nos sistemas atuais. / This project intended to minimize one of the main disadvantages of using natural gas vehicles, which was the loss of power, and increase their volumetric efficiency by building an electronic circuit able to efficiently manage the gas injection. The increase in volumetric efficiency is obtained through the efficient management of air-fuel mixture using a closed loop system. The management of the power and economy ratio is achieved with the simultaneous use of natural gas and liquid fuel. In the current conversion systems and original vehicles that use natural gas, the power loss is compensated by turning off the gas system and using only the liquid fuel. This selection is done manually in most conversion systems, and automatically at Fiat Siena Tetrafuel, not allowing the simultaneous use of gas to liquid fuel. The demand for power is measured by the angle of the accelerator pedal. When the power demand is low, the system operates only with natural gas. When intermediate power is required, the system operates with different proportions of ethanol and natural gas. For maximum power, only ethanol is used. Comparisons were made between the conventional and the proposed system through dynamometer tests, road tests and emission analyses. The Volkswagen Gol with original system using only ethanol has a maximum power of 64.06 horses (47.77 Kilowatts) and consumption of 12.6 kilometers per liter of ethanol. With conventional aspirated natural gas system, the consumption was 21 km per cubic meter and the power did not exceed 51.82 horses (38.64 Kilowatts). With the prototype, volumetric efficiency increases by 25%, with consumption of 26.4 kilometers per cubic meter. The power management provides intermediate powers up to 51.82 horses (38.64 Kilowatts) until the maximum power of 64.06 horses (47.77 Kilowatts) in situations where more power is required. The developed system provides the benefit of refueling flexibility found in the original system, with power flexibility not available in original systems.
375

Desenvolvimento de um gerenciador eletrônico para motores tricombustível. / Development of an electronic controller for tri-fuel engines.

Michel Robert Veiga 10 September 2010 (has links)
O objetivo do desenvolvimento do projeto foi minimizar uma das principais desvantagens no uso do gás natural veicular, que é a perda de potência, e aumentar sua eficiência volumétrica através da construção de um circuito eletrônico capaz de gerenciar de forma eficiente a injeção do gás. O aumento do rendimento é obtido através do gerenciamento eficiente da mistura ar-combustível utilizando um sistema de malha fechada. O gerenciamento da relação de potência e economia é conseguido com o uso simultâneo de gás natural e o combustível líquido. Nos sistemas de conversão atuais e nos veículos originais a gás natural, a perda de potência é compensada desligando o sistema de gás e utilizando somente o combustível líquido, sendo esta seleção feita de forma manual na maioria dos sistemas de conversão e de forma automática no Fiat Siena tetrafuel, não possibilitando o uso simultâneo do gás com o combustível líquido. A exigência de potência é medida através do ângulo do pedal do acelerador. Quando a exigência de potência é baixa, o sistema opera apenas com gás. No momento em que há solicitação de potência intermediária, o sistema opera com diferentes proporções de etanol e gás. Na situação de solicitação de potência máxima, é utilizado apenas o combustível líquido. Foram feitas comparações entre o sistema convencional e o sistema proposto, através de ensaios dinamométricos, rodoviários e emissão de poluentes. O veículo Volkswagen Gol com seu sistema original utilizando somente etanol possui potência máxima de 64,06 cavalos, (47,77 Kilowatts) e consumo de 12,6 quilômetros por litro de etanol. Com o sistema convencional de gás natural aspirado, o consumo foi de 21 quilômetros por metro cúbico e a potência não ultrapassou 51,82 cavalos (38,64 Kilowatts), com o protótipo desenvolvido a eficiência volumétrica aumentou 25% com consumo de 26,4 quilômetros por metro cúbico. O gerenciamento de potência proporciona potências intermediárias acima de 51,82 cavalos (38,64 Kilowatts), até a potência máxima de 64,06 cavalos (47,77 Kilowatts) em situações que uma maior potência é requerida. O sistema desenvolvido proporciona o benefício da flexibilidade no abastecimento disponível nos sistemas atuais, com a flexibilidade na potência não disponível nos sistemas atuais. / This project intended to minimize one of the main disadvantages of using natural gas vehicles, which was the loss of power, and increase their volumetric efficiency by building an electronic circuit able to efficiently manage the gas injection. The increase in volumetric efficiency is obtained through the efficient management of air-fuel mixture using a closed loop system. The management of the power and economy ratio is achieved with the simultaneous use of natural gas and liquid fuel. In the current conversion systems and original vehicles that use natural gas, the power loss is compensated by turning off the gas system and using only the liquid fuel. This selection is done manually in most conversion systems, and automatically at Fiat Siena Tetrafuel, not allowing the simultaneous use of gas to liquid fuel. The demand for power is measured by the angle of the accelerator pedal. When the power demand is low, the system operates only with natural gas. When intermediate power is required, the system operates with different proportions of ethanol and natural gas. For maximum power, only ethanol is used. Comparisons were made between the conventional and the proposed system through dynamometer tests, road tests and emission analyses. The Volkswagen Gol with original system using only ethanol has a maximum power of 64.06 horses (47.77 Kilowatts) and consumption of 12.6 kilometers per liter of ethanol. With conventional aspirated natural gas system, the consumption was 21 km per cubic meter and the power did not exceed 51.82 horses (38.64 Kilowatts). With the prototype, volumetric efficiency increases by 25%, with consumption of 26.4 kilometers per cubic meter. The power management provides intermediate powers up to 51.82 horses (38.64 Kilowatts) until the maximum power of 64.06 horses (47.77 Kilowatts) in situations where more power is required. The developed system provides the benefit of refueling flexibility found in the original system, with power flexibility not available in original systems.
376

Projeto e desenvolvimento de um sistema de análises químicas por injeção em fluxo para determinações espectrofotométricas simultâneas de cobre e de níquel explorando cinética diferencial e calibração multivariada / Project and development of a flow-injection system for simultaneous spectrophotometric determination of copper and nickel exploiting differential kinetics and multivariate calibration

Sasaki, Milton Katsumi 09 June 2011 (has links)
Análise cinética diferencial explora diferenças em taxas reacionais entre os analitos e um sistema reacional comum; etapas de separação prévia dos analitos podem então ser prescindidas. Sistemas de análise por injeção em fluxo (FIA) se afiguram como uma ferramenta importante para métodos envolvendo essa estratégia, pois permitem um controle preciso da dispersão de reagentes / amostras e da temporização. O objetivo deste trabalho foi então explorar estes dois aspectos favoráveis visando a determinação simultânea de cobre e de níquel, a partir de suas reações com o reagente cromogênico 5-Br-PADAP. Três alíquotas de amostra eram simultaneamente inseridas, por meio de um injetor proporcional, no fluxo transportador reagente (5-Br-PADAP 75 mg L-1 + sistema tampão 0,5 mol L-1 em ácido acético / acetato, pH 4,7) de um sistema FIA em linha única. Durante o transporte em direção ao detector, as zonas estabelecidas se coalesciam, originando uma zona complexa que era monitorada a 562 nm. Os valores locais máximos e mínimos da função concentração / tempo obtida eram considerados para calibração multivariada utilizando a ferramenta quimiométrica PLS-2 (partial least squares - 2). A concentração do reagente, a capacidade tampão, a temperatura, a vazão, os comprimentos do percurso analítico e das alças de amostragem, bem como a distância inicial entre as zonas de amostra estabelecidas foram avaliados para construção dos modelos matemáticos. Estes foram criados a partir de 24 soluções-padrão mistas de Cu2+ e Ni2+ (0,00-1,60 mg L-1 em HNO3 a 0,1% v/v). Duas variáveis latentes foram suficientes para capturar > 98 % das variâncias inerentes ao conjunto de dados e erros médios das previsões (RMSEP) foram estimados em 0,025 e 0,071 mg L-1 para Cu e Ni, salientando a boa precisão do modelo de calibração. O sistema proposto apresenta boas figuras de mérito: fisicamente estável, quando mantido em operação por quatro horas ininterruptas, consumo de 314 \'mü\'g 5-Br-PADAP por amostra, frequência analítica de 33 amostras por hora (165 dados, 66 determinações) e erros nas leituras em sinais de absorbância tipicamente < 5%. Entretanto, verificou-se a inexatidão das previsões efetuadas pelo modelo proposto, quando comparadas aos resultados obtidos por ICP OES. A partir deste fato, tornam-se necessários maiores estudos referentes a este tipo de matriz, bem como de técnicas de mascaramento dos possíveis interferentes presentes / Differential kinetic analysis exploits the differences in reaction rates between the analytes and a common reactant system; prior steps of analyte separation can then be waived. Flow-injection systems (FIA) are considered as an important tool for methods involving such a strategy because they allow precise control of sample / reagent dispersion and timing. The aim of this work was then to exploit these two favorable aspects for the simultaneous determination of copper and nickel using the 5-Br-PADAP chromogenic reagent. Three sample aliquots were simultaneously inserted by means of a proportional injector into reagent carrier stream (75 mg L-1 5-Br-PADAP + 0.5 mol L-1 acetic acid / acetate, pH 4.7) of a single-line FIA system. During transport towards detection, the established zones coalesce themselves, resulting in a complex zone that was monitored at 562 nm. The local maximum and minimum values of the concentration / time obtained function were considered for multivariate calibration using the PLS-2 (partial least squares - 2) chemometric tool. The reagent concentration, buffering capacity, temperature, flow rate and lengths of the analytical path, sampling loops and initial distance between plugs were established and evaluated for the construction of mathematical models. To this end, 24 Cu2+ and Ni2+ (0.00 - 1.60 mg L-1, also 0.1% v/v HNO3) mixed standard solutions were used. Two latent variables were enough to capture > 98% of the variance inherent in the data set and average prediction errors (RMSEP) were estimated as 0.025 and 0.071 mg L-1 for Cu and Ni, emphasizing the good precision the calibration model. The proposed system presents good figures of merit: physical stability when kept in operation for four uninterrupted hours, consumption of 314 \'mü\'g 5-Br-PADAP per sample, sample throughput of 33 h-1 (165 data, 66 determinations) and error readings in absorbance signals typically <5%. However, inaccuracy of the predictions made by the proposed model when compared to results obtained by ICP OES was noted. Thus, further studies involving this type of matrix, as well as masking techniques of potential interferences present, are recommended
377

Dose savings in digital breast tomosynthesis through image processing / Redução da dose de radiação em tomossíntese mamária através de processamento de imagens

Borges, Lucas Rodrigues 14 June 2017 (has links)
In x-ray imaging, the x-ray radiation must be the minimum necessary to achieve the required diagnostic objective, to ensure the patients safety. However, low-dose acquisitions yield images with low quality, which affect the radiologists image interpretation. Therefore, there is a compromise between image quality and radiation dose. This work proposes an image restoration framework capable of restoring low-dose acquisitions to achieve the quality of full-dose acquisitions. The contribution of the new method includes the capability of restoring images with quantum and electronic noise, pixel offset and variable detector gain. To validate the image processing chain, a simulation algorithm was proposed. The simulation generates low-dose DBT projections, starting from fulldose images. To investigate the feasibility of reducing the radiation dose in breast cancer screening programs, a simulated pre-clinical trial was conducted using the simulation and the image processing pipeline proposed in this work. Digital breast tomosynthesis (DBT) images from 72 patients were selected, and 5 human observers were invited for the experiment. The results suggested that a reduction of up to 30% in radiation dose could not be perceived by the human reader after the proposed image processing pipeline was applied. Thus, the image processing algorithm has the potential to decrease radiation levels in DBT, also decreasing the cancer induction risks associated with the exam. / Em programas de rastreamento de câncer de mama, a dose de radiação deve ser mantida o mínimo necessário para se alcançar o diagnóstico, para garantir a segurança dos pacientes. Entretanto, imagens adquiridas com dose de radiação reduzida possuem qualidade inferior. Assim, existe um equilíbrio entre a dose de radiação e a qualidade da imagem. Este trabalho propõe um algoritmo de restauração de imagens capaz de recuperar a qualidade das imagens de tomossíntese digital mamária, adquiridas com doses reduzidas de radiação, para alcançar a qualidade de imagens adquiridas com a dose de referência. As contribuições do trabalho incluem a melhoria do modelo de ruído, e a inclusão das características do detector, como o ganho variável do ruído quântico. Para a validação a cadeia de processamento, um método de simulação de redução de dose de radiação foi proposto. Para investigar a possibilidade de redução de dose de radiação utilizada na tomossíntese, um estudo pré-clínico foi conduzido utilizando o método de simulação proposto e a cadeia de processamento. Imagens clínicas de tomossíntese mamária de 72 pacientes foram selecionadas e cinco observadores foram convidados para participar do estudo. Os resultados sugeriram que, após a utilização do processamento proposto, uma redução de 30% de dose de radiação pôde ser alcançada sem que os observadores percebessem diferença nos níveis de ruído e borramento. Assim, o algoritmo de processamento tem o potencial de reduzir os níveis de radiação na tomossíntese mamária, reduzindo também os riscos de indução do câncer de mama.
378

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Barrientos, Marcia Otto 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
379

Sistemas de análises químicas em fluxo explorando mecanismos de re-alimentação, calibração multivariada e outras abordagens para melhoria em desempenho / Flow systems exploiting feed-back mechanisms, multivariate calibration and other strategies for improving the analytical performance

Fortes, Paula Regina 30 June 2010 (has links)
Estudos foram conduzidos relativamente ao desempenho dos sistemas de análises em fluxo quando configurados como sistemas inteligentes, associados às técnicas de calibração multivariada ou empregando nanocristais como sensibilizadores. Ainda, melhorias relacionadas às modificações dos fluxos foram avaliadas, especialmente no que se refere à diálise em linha. Neste sentido, foi proposta uma nova estratégia para implementar determinações simultâneas de ferro e vanádio em ligas metálicas envolvendo cinética diferencial. O método baseava-se nas diferentes influências exercidas por Fe2+ e por V4+ na taxa de oxidação de íons iodeto por íons Cr6+ sob condições ácidas. Três diferentes alíquotas de amostra eram inseridas em um fluxo transportador / reagente de KI, confluindo posteriormente com um fluxo de K2Cr2O7. A sobreposição entre as três zonas de amostra estabelecidas resultava em uma zona de amostra complexa com diversos valores de absorbância. Medidas realizadas nos pontos de máximos e minímos do sinal registrado eram mais precisas e continham informações acerca dos diferentes estágios de desenvolvimento da reação e de diferentes condições de concentrações. Em outra estratégia, um sistema MPFS inteligente foi proposto para a determinação turbidimétrica sequencial de sulfato e cloreto em águas naturais. Ambos os métodos foram implementados no mesmo módulo de análises, proporcionando facilidades relativas ao: preparo de amostra em linha; adição de íons sulfato ou cloreto ao meio reacional para melhoria das condições de supersaturação; decisão em tempo real acerca da necessidade ou não da próxima análise. Inicialmente, determinava-se a concentração de cloreto presente na amostra, e este resultado era comparado com um valor pré-determinado. Se este fosse superior, a amostra era analisada novamente visando à determinação de sulfato. Caso contrário, uma nova amostra era analisada. A estratégia resultou em aumento da velocidade analítica e em boas figuras de mérito analítico. Estudos relativos à natureza do fluxo foram conduzidos avaliando-se o desempenho dos fluxos pulsados provenientes de bombas solenóide em relação à eficiência do transporte de massas, dispersão da zona de amostra relacionada com a mudança de sentido do fluxo e eficiência do processo de diálise quando comparados aos fluxos tipicamente laminares. Embora fosse observada a presença de vórtices, o número de Reynolds experimentalmente obtido demonstrou que o fluxo resultante não era turbulento. Porém seu perfil exibia características de mescla turbulenta, melhorando assim o desempenho relativo ao transporte de massas e redução da dispersão da zona de amostra. Entretanto, beneficios relativos a melhorias no processo de diálise foram ausentes devido provavelmente à alta pressão exercida dentre da câmara de diálise, com consequente deformação dos poros da membrana. Nestas situações, um sistema de análises híbrido (com fluxo laminar e mescla turbulenta) seria fortemente recomendado. Finalmente, a implementação de nanocristais quantum dots (QDs) como sensibilizadores em um sistema MPFS envolvendo reação quimioluminescente foi proposta para a determinação de glipizida e gliclazida em formulaçoes farmacêuticas. O método fundamentava-se na oxidação dos íons S2- por Ce4+ em meio ácido. Na presença dos analitos, a intensidade da radiação emitida era inibida. A influência do diâmetro médio dos nanocristais foi avaliada, e os critérios utilizados para o dimensionamento do sistema foram a repetibilidade, a reprodutibilidade e a sensibilidade analítica. Os analitos foram quantificados no mesmo módulo de análises, e boas figuras de mérito analítico foram verificadas. Os resultados obtidos se apresentaram concordantes com aqueles obtidos pela Farmacopéia Britânica / Studies focusing on performance of intelligent analytical flow systems, association with multivariate calibration or use of nanocrystals as sensitizers were carried out. Moreover, improvements related to modifications in flow pattern were evaluated with emphasis to in-line dialysis. To this end, a strategy for implementing simultaneous determinations of iron and vanadium in alloys relying on differential kinetics was proposed. The method was based on the influence of Fe2+ and V4+ on the rate of iodide oxidation by Cr6+ under acidic conditions. Three different plugs of the sample were sequentially inserted into an acidic KI reagent carrier stream, and a confluent K2Cr2O7 solution was added downstream. Overlap between the established plugs led to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions were more precise and revealed the different degrees of reaction development. In another strategy, an intelligent MPFS was proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods were implemented in the same manifold, providing facilities for: in-line sample cleanup; addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation conditions and real-time decision on the need for next assay. The sample was initially run for chloride determination, and the analytical signal was compared with a preset value. If higher, the sample was run again, now for sulphate determination. Otherwise, next sample was assayed. The strategy led to an increased sample throughput and good analytical figures of merit. Studies focusing on the flow pattern were carried out aiming at the evaluation of the influence of the pulsed flows delivered by solenoid pumps in relation to the efficiency of mass transfer, dispersion related to changes in flow direction of the sample zone and dialysis process as compared with typical laminar flow. Although the establishment of vortices were noted, the experimentally obtained Reynolds number showed that a turbulent flow was not established. Its pattern exhibited characteristics which improved the performance due to the enhanced radial mass transport inherent in turbulent mixing. Comparatively to laminar flow, beneficial aspects were noted in relation to sample dispersion and mass transfer. In relation to dialysis efficiency however process the benefits were not noted probably due to the high pressure inside the dialysis chamber, with consequent membrane pore deformation. In this situation, a hybrid flow analysis system (with laminar flow and turbulent mixing) might be recommended. Implementation of quantum dots nanocrystals (QDs NC) as sensitizers in a MPFS with chemiluminometric detection was proposed for the determinations of gliclazide and glipizide in pharmaceutical formulations. The method relied on the oxidation of sulphite by Ce4+ in acidic medium and, in the presence of the analytes, the emitted radiation of the Ce4+-SO3 2--CdTe QDs system was inhibited. Influence of crystal size was investigated, and the criteria for system optimization were the analytical repeatability, reproducibility and sensitivity. Both analytes were quantified in the same manifold, resulting in good analytical figures of merit. The results were in fairly good agreement with those obtained by the British Pharmacopoeia reference method
380

Influência da atmosfera de sinterização na dureza e resistência à corrosão do aço inoxidável 17-4 PH conformado a partir do processo de moldagem de pós por injeção / Influence of sintering atmosphere in the hardness and corrosion resistance of 17-4 PH stainless steel shaped from powder injection molding process

Freitas, Willian Januário de 20 March 2015 (has links)
O processo de moldagem de pós injeção é utilizado para a fabricação de peças de geometrias complexas e com alto volume de produção. Em aplicações ortodônticas e médicas, nas quais são requeridas elevadas durezas e resistências à corrosão, o aço inoxidável 17-4 PH é utilizado aplicando-se aquela técnica de conformação. A atmosfera de sinterização é responsável pelo controle das reações químicas que ocorrem durante a densificação do material e são fundamentais para a qualidade final do produto. O objetivo deste trabalho foi avaliar a influência da atmosfera de sinterização na dureza e resistência à corrosão deste tipo de aço. A remoção dos ligantes primários foi realizada por meio de extração química utilizando-se um solvente com menor impacto ambiental, que se mostrou adequado a tal fim. A extração térmica posterior dos ligantes foi realizada pelo aquecimento nas temperaturas de 250°C e 450°C sendo, posteriormente, a temperatura elevada a 900°C, para o início da sinterização. Utilizou-se atmosferas de Nitrogênio, Vácuo e Hidrogênio, com temperaturas de sinterização de 1250°C e 1330°, com tempos de patamares de 30 e 60 minutos. Verificou-se que as densidades atingidas nas atmosferas de Hidrogênio e Vácuo são semelhantes e se adequaram às especificações requeridas pela norma, enquanto a atmosfera de Nitrogênio resultou em características inferiores. As durezas e as resistências à corrosão obtidas com o uso das atmosferas de Hidrogênio e Vácuo foram também superiores as das amostras sinterizadas em atmosfera de Nitrogênio. / The powder injection molding process is used to manufacture parts with complex shapes, with high production demand. In orthodontic and medical applications, in which high hardness and corrosion resistance are required, 17-4 PH stainless steel is used by applying this forming technique. The sintering atmosphere is responsible for controlling the chemical reactions that occur during material densification and is critical to the ultimate product quality. This research study aims at evaluating the influence of the sintering atmosphere on the hardness and corrosion resistance of this type of steel. The removal of the primary binder was carried out by chemical extraction applying a solvent with less environmental impact, which has proved to be suitable for this purpose. The subsequent binder thermal extraction was held by heating at temperatures of 250°C and 450°C and, therefore, at temperature of 900°C, to initiate sintering. Nitrogen, vacuum and hydrogen atmospheres were used with sintering temperatures at 1250°C and 1330°, with 30 and 60 minute-step time. It was verified that the densities achieved in hydrogen and vacuum atmospheres are similar and suitable by the regulations, whereas the nitrogen atmosphere resulted in lower performance. The hardness and corrosion resistance obtained with the use of hydrogen and vacuum atmospheres were also higher than those obtained for samples sintered in the nitrogen atmosphere.

Page generated in 0.045 seconds