• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 30
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 129
  • 50
  • 41
  • 33
  • 30
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas

Reis, José Mauricio dos Santos Nunes [UNESP] 03 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-03Bitstream added on 2014-06-13T19:44:47Z : No. of bitstreams: 1 reis_jmsn_dr_arafo.pdf: 1310753 bytes, checksum: 17bd719b0c46c00b10cbd2db022db42a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... / This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below)
92

Efeito da incorporação de agentes antifúngicos na resistência à tração e porosidade de materiais resilientes temporários para base de próteses / Effect of incorporation of antifungal agents on the ultimate tensile strength and porosity of temporary soft denture liners

Jozely Francisca Mello Lima 10 February 2017 (has links)
Este estudo investigou a resistência à tração (ou limite de resistência à tração- LRT) e a porosidade de reembasadores resilientes temporários modificados por concentrações inibitórias mínimas (CIMs) de agentes antifúngicos para o biofilme Candida albicans (SC5314). Para os testes de LRT, corpos de prova em forma de halteres (n=7) com uma área transversal de 33 mm x 6 mm x 3 mm foram produzidos para os materiais resilientes (Trusoft e Softone) sem (controle) ou com incorporação de cinco fármacos em suas CIMs: nistatina- 0,032 g; diacetato de clorexidina- 0,064; cetoconazol- 0,128 g; miconazol- 0,256 g; itraconazol-0,256 g (grama de fármaco por grama de pó de material resiliente). Após a plastificação, as amostras foram imersas em água destilada a 37°C durante 24 h, 7 e 14 dias e, então, testadas em tensão em uma máquina universal de ensaios (EMIC DL-500 MF) a 40 mm/min. A porosidade foi mensurada por absorção de água, com base na exclusão do efeito plastificante. Inicialmente, determinou-se por isotermas de sorção, que a solução de armazenagem adequada para os corpos de prova (65 mm x 10 mm x 3,3 mm) de ambos os materiais foi o cloreto de cálcio anidro a 50% (S50). Assim, o fator de porosidade (FP) foi calculado para os grupos de estudo (n=10) formados por espécimes sem (controle) ou com incorporação de fármaco em suas CIMs (nistatina, clorexidina ou cetoconazol) após a armazenagem em água destilada ou S50 por 24 h, 7 e 14 dias. Os dados de resistência à tração (MPa) e percentagem de alongamento (%) foram submetidos à ANOVA de 3 fatores seguida pelo teste de Tukey (=0,05). Os dados de porosidade foram analisados estatisticamente por ANOVA de medidas repetidas para 4 fatores e teste de Tukey (=0,05). Ao final de 14 dias, a resistência à tração para ambos os materiais foi significativamente menor nos grupos modificados pelo miconazol e itraconazol em relação aos outros grupos (P<0,0001), que não mostraram diferenças significativas entre si (P>0,05). Após 7 e 14 dias em água, o miconazol e itraconazol adicionados a ambos os materiais resultaram em percentagens significativamente menores de alongamento em comparação com os outros fármacos e ao controle (P<0,0001), que foram semelhantes entre si (P>0,05). O cetoconazol não resultou em alterações significativas no FP para ambos os materiais resilientes em água ao longo de 14 dias (P>0,05). Em comparação aos controles, houve aumento dos FPs do Softone e Trusoft aos 14 dias de imersão em água somente após a adição de nistatina e clorexidina e de clorexidina, respectivamente (P<0,05). Ambos os materiais não apresentaram alterações significativas no FP em até 14 dias de imersão na S50, em comparação aos controles (P>0,05). Em todas as condições experimentais, os FPs do Softone e Trusoft foram significativamente menores quando imersos em S50 em comparação com a água destilada (P<0,05). Concluiu-se que a adição de nistatina, clorexidina e cetoconazol nas CIMs para o biofilme de C. albicans não resultou em efeitos deletérios na resistência à tração e na percentagem de alongamento dos materiais resilientes temporários para base de prótese até o período de 14 dias. A adição de antifúngicos nas CIMs não resultou em efeitos adversos à porosidade de ambos os materiais resilientes temporários em diferentes períodos de imersão em água, com exceção da clorexidina e nistatina no Softone e clorexidina no Trusoft aos 14 dias. Não foram observados efeitos deletérios para a porosidade de ambos os materiais resilientes modificados com as CIMs dos fármacos durante os 14 dias de imersão na S50. / This study investigated the tensile strength (ultimate tensile strength- UTS) and porosity of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314). For UTS tests, dumbbell-shaped specimens (n=7) with a central cross-sectional area of 33 mm x 6 mm x 3 mm were produced by resilient materials (Trusoft and Softone) without (control) or with incorporation of five drugs at MICs: nystatin- 0.032 g; chlorhexidine diacetate-0.064 g; ketoconazole- 0.128 g; miconazole- 0.256 g; itraconazole- 0.256 g (each per gram of soft liner powder). After plasticization, specimens were immersed in distilled water at 37°C for 24 h, 7 and 14 days, and then tested in tension in a universal testing machine (EMIC DL-500 MF) at 40 mm/min. The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65 mm x 10 mm x 3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin, chlorhexidine or ketoconazole) after storage in distilled water or S50 for 24 h, 7 and 14 days. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA followed by Tukey\'s test (=0.05). Data of porosity were statistically analyzed by 4-way repeated measures ANOVA and Tukeys test (=0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (P<0.0001), which showed no significant difference between them (P>0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials result in significant lower elongation percentages compared to the other drugs and control (P<.0001), which were similar to each other (P>0.05). Ketoconazole resulted in no significant changes in PF for both liners in water over 14 days (P>0.05). Compared to the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of nystatin and chlorhexidine, and chlorhexidine, respectively (P<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared to the controls (P>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared to distilled water (P<0.05). It was concluded that the addition of the nystatin, chlorhexidine and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the ultimate tensile strength and elongation percentage of the temporary soft denture liners up to 14-day period. The addition of antifungals at MICs resulted in no detrimental effects for the porosity of both temporary soft liners in different periods of water immersion, except for chlorhexidine and nystatin in Softone and chlorhexidine in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.
93

Avaliação da eficácia de barreiras de proteção ambiental produzidas com solo arenoso estabilizado quimicamente

Rizzo, Rodrigo Pelho [UNESP] 26 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-26Bitstream added on 2014-06-13T18:21:09Z : No. of bitstreams: 1 rizzo_rp_me_ilha.pdf: 2484817 bytes, checksum: d447a4c31b21a9373e9067be45abcaad (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As barreiras de proteção ambiental são os dispositivos mais usados na atualidade para reduzir riscos associados à infiltração de fluidos nocivos no subsolo. O presente trabalho dedicou-se ao estudo, em laboratório, de misturas de solo arenoso fino laterítico com cal e cimento para a produção de barreiras desta natureza. Para tanto, foram compactadas misturas a fim de produzir corpos de prova submetidos a ensaios, visando à avaliação da condutividade hidráulica e da capacidade de retenção de soluções de origem orgânica (chorume e água residuária) e inorgânica (soluções contendo os íons K+, Na+ e Cl-) destas misturas. A condutividade hidráulica foi avaliada com ensaios de permeabilidade em duas condições: à carga variável (corpos de prova de 10cm de diâmetro e 12cm de altura) e em área plena (corpos de prova miniatura – 5cm de altura e diâmetro). Para avaliação da capacidade de retenção foram considerados dois tipos de ensaios: em colunas (25cm de altura e 7cm de diâmetro) e em corpos miniatura (5cm de altura e diâmetro). Os resultados obtidos mostram que os materiais produzidos em tais condições atendem aos requisitos técnicos para seu uso como barreiras de proteção ambiental. Os valores de condutividade hidráulica obtidos foram menores que os exigidos e os processos de retenção observados mostraram resultados muito bons para os fluidos de origem orgânica e resultados bastante promissores para as soluções inorgânicas. / Natural liners are the most useful environmental protection systems in order to reduce soil and ground water pollution risks. In this work we made laboratory tests to evaluate hydraulic conductivity and ions retention capability in mixtures produced with soil-cement and soil-lime. Mixtures were compacted, resulting specimens for laboratory tests of hydraulic conductivity and retention capability with organic (leachate and wastewater) and inorganic (solutions with K+, Na+ e Cl-) solutions. For hydraulic conductivity evaluation was used two kinds of tests: variable charge (specimens with 10cm of diameter and 12cm high) and total section test (specimens with 5cm of diameter and high). For retention capability we used also two kinds of tests: column test (specimens with 7cm of diameter and 25cm high) and total section test (specimens with 5cm of diameter and high). Obtained results show that the produced materials obey technical necessities for barriers usage. Hydraulic conductivity obtained show values lesser than the necessary, while capability retention results show good results also for organic and inorganic solutions.
94

Efeito de tempos de simulação do intemperismo natural na deformação permanente dos materiais reembassadores resilientes e na resitencia a tração da sua união com a resina acrilica / Effect of accelerated ageing on the permanet deformation and tensite bond strenght of auto-polymerizing soft dentures liners

Takahashi, Jessica Mie Ferreira Koyama 02 May 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:45:53Z (GMT). No. of bitstreams: 1 Takahashi_JessicaMieFerreiraKoyama_M.pdf: 3156848 bytes, checksum: e45be536e6455880f4523ac84c0d2894 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes tempos de envelhecimento acelerado realizado por meio da simulação do intemperismo natural, sobre as propriedades de deformação permanente e resistência à tração da união de dois materiais resilientes usados como forradores de base de prótese, sendo um à base de resina acrílica e outro à base de silicone. Para o ensaio de resistência à tração da união, os materiais reembasadores foram unidos a dois blocos de resina acrílica (9 X 9 X 40 mm) utilizada para a confecção de bases de próteses totais. Para o ensaio de deformação permanente, os corpos-de-prova de reembasador resiliente apresentaram 19 mm de altura e 12,7 mm de diâmetro. Os corpos-de-prova (n=10) foram submetidos ao envelhecimento acelerado nos tempos 2, 4, 8, 16, 32 e 64 ciclos por meio da simulação do intemperismo natural. O ensaio de resistência à tração da união foi realizado em máquina de ensaios EMIC DL-500 MF com velocidade média de 5 mm/min, sendo avaliado também o tipo de falha de união (adesiva, coesiva ou mista). Para o ensaio de deformação permanente foi utilizado aparelho mecânico descrito na especificação no 18 da A.D.A., com carga compressiva de 750 gf. Foi realizada análise estatística utilizando o teste Kruskall-Wallis associado ao método de Dunn, para comparação entre os materiais no mesmo intervalo de envelhecimento, e o teste Mann-Whitney para comparação do efeito dos tempos de envelhecimento em cada material. Avaliando os resultados obtidos após a análise estatística, pôde-se observar que o reembasador à base de silicone apresentou menor porcentagem de deformação permanente (p<0,0001) e maior resistência à tração (p<0,0001) que o reembasador à base de resina acrílica em todos os intervalos de envelhecimento. E que a simulação do intemperismo natural não afetou a deformação permanente (p=0,90) e a resistência à tração (p=0,15) do reembasador à base de silicone, mas reduziu a porcentagem de deformação permanente e aumentou a resistência à tração do material à base de resina acrílica (p<0,05). Os resultados demonstraram que o reembasador resiliente à base de silicone é menos susceptível à cargas compressivas, pois apresentou melhor recuperação elástica, menor deformação permanente e maior resistência à tração que o à base de resina acrílica. E que o envelhecimento acelerado, afeta as propriedades de deformação permanente e resistência à tração do material reembasador à base de resina acrílica. / Abstract: This study aimed to evaluate the effect of different times of accelerated ageing over the properties of permanent deformation and tensile bond strength of two soft liners used on prostheses relining. The soft liners studied were auto-polymerizing and acrylic resin and silicone based. The materials were processed according the manufacturers' instructions. The resilient liner specimens (9 X 9 X 3 mm) for tensile bond strength were processed between 2 acrylic resin blocks (9 X 9 X 40 mm). The resilient liner specimens for permanent deformation test were 19 mm height and 12.7 mm diameter. The specimens (n=10) were submitted to accelerated ageing process during 2, 4, 8, 16, 32 and 64 cycles. Tensile bond strength was performed with crosshead speed of 5 mm/min using a testing machine EMIC DL-500 MF. Permanent deformation was performed with an apparatus described on specification no 18 of A.D.A., with compressive load of 750 gf. Statistical analysis was performed using Kruskall-Wallis and Dunn tests to compare materials on the same ageing period and Mann-Whitney test to compare the effect of different ageing periods on each material. The results obtained after statistical analysis demonstrated that the silicone based reliner presented lower percentage of permanent deformation (p<0.0001) and higher tensile bond strength (p<0.0001) than the acrylic resin based reliner in all the ageing intervals. And that the accelerated ageing process did not affect the permanent deformation (p=0.90) and tensile bond strength (p=0.15) of the silicone based reliner, but reduced the percentage of permanent deformation and increased tensile bond strength of the acrylic resin based reliner (p<0.05). Results demonstrated that silicone based reliner is less susceptible to compressive loads, presenting better elastic recovery, lower permanent deformation and higher tensile bond strength. And that accelerated ageing affected only acrylic resin based reliners. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
95

Torneamento interno de cilindros automotivos de ferro fundido cinzento centrifugado / Internal turning for cylinder liners made of centrifuged gray cast iron

Rossi Neto, Eneas 02 May 2009 (has links)
Orientador: Amauri Hassui / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T23:13:39Z (GMT). No. of bitstreams: 1 RossiNeto_Eneas_M.pdf: 13972971 bytes, checksum: 1c7b89f4fdc28248118cde9b4b90db25 (MD5) Previous issue date: 2009 / Resumo: Neste trabalho procurou-se estudar e desenvolver um processo inédito de usinagem para ser implementado na manufatura dos cilindros automotivos, componentes muito importantes utilizados nos motores de automóveis que possuem bloco de alumínio. São poucos e conhecidos os fabricantes do segmento automotivo que fabricam este produto, sendo que, até então, todos utilizavam operação de mandrilamento para usinagem do diâmetro interno da camisa. Entre outras vantagens, este trabalho propõe aumentar a produtividade de maneira significativa, atendendo todas as especificações técnicas do produto. A operação de mandrilamento foi substituída por torneamento interno, utilizando um centro de torneamento com sistema de carga e descarga integrado, ferramentas de corte e dispositivos de fixação especiais e estratégias de usinagem diferenciadas. As camisas para cilindro são fabricadas de ferro fundido cinzento centrifugado, um material extremamente abrasivo que requer cuidados na sua manufatura. Após o desenvolvimento completo do processo e prévios ensaios de usinagem para definição das premissas, utilizou-se uma metodologia objetiva para otimização do processo proposto, realizada no ambiente fabril, considerando todas as variáveis encontradas nas condições reais de produção. Os resultados obtidos mostraram que os insertos de metal duro com cobertura apresentaram um melhor desempenho que os insertos de cerâmica à base de nitreto de silício e de óxido de alumínio na aplicação em estudo, sendo constatado também as melhores condições de corte para o torneamento interno de cilindros automotivos de ferro fundido cinzento centrifugado / Abstract: This investigation describes and shows an unprecedented machining process to be used for manufacturing cylinder liners, which are very important parts used in aluminum engine blocks for automobiles. There are few known companies that manufacture this kind of component, and until now, all of them use a boring process to machine the internal diameter of the cylinder liner. Among other advantages, this investigation intends to increase significantly productivity, while respecting all technical specifications of the product. The boring process was replaced by internal turning, which uses a turning center with load/unload system, special cutting tools and clamp devices, as well as audacious machining strategies. The cylinder liners are made from centrifuged gray cast iron, an extreme abrasive material that needs special care during its machining process. After the complete development of the process and tryouts to define the preliminary data, it has been used an objective methodology to optimize the proposed process, developed on the shop floor, considering all the variables found in real production conditions. The investigation results shown the carbide inserts had better performance than the silicon nitride and aluminum oxide ceramic inserts in this studied application, evidencing the best cutting conditions to internal turning for cylinder liners made of centrifuged gray cast iron / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
96

Efeito do etil-cianoacrilato (Super Bonder®) e do polidor líquido de baixa viscosidade (Biscover®) sobre biofilme de Candida albicans em resina acrílica para reembasamento / Effect of ethyl-cyanoacrylate (Super Bonder®) and a liquid polish of low viscosity (Biscover®) on Candida albicans biofilms on denture reline resin

Flora Freitas Fernandes Távora 10 July 2012 (has links)
A proposta desse trabalho foi verificar através de microscopia confocal de varredura a laser, se a utilização de uma resina fotopolimerizável de baixa viscosidade (Biscover®) e do etil-cianoacrilato (Super Bonder®) seriam eficientes em prevenir ou reduzir a formação de biofilme de Candida albicans. Cinqüenta e seis corpos de prova em resina acrílica para reembasamento (New Truliner) foram divididos aleatoriamente em 7 grupos: G1 (C)- Controle; G2 (SBAE)- Recebeu uma camada de Super Bonder® em sua superfície antes de esterilizar; G3 (SBDE)- Recebeu uma camada de Super Bonder® em sua superfície depois de esterilizar; G4 (SB3G)- 3 gotas de Super Bonder® incorporadas na resina; G5 (SB4G)- 4 gotas de Super Bonder® incorporadas na resina; G6 (BCDE)- Recebeu uma camada de Biscover® em sua superfície depois de esterilizar e G7 (BCAE) Recebeu uma camada de Biscover® em sua superfície antes de esterilizar. Todos os corpos de prova foram inoculados com Candida albicans para formação de biofilme. Os biofilmes remanescentes sobre os corpos de prova foram corados através dos fluorocromos SYTO-9 e iodeto de propídeo para análise no microscópio confocal. Os dados foram analisados através dos testes estatísticos de Kruskal-Wallis e Dunn, a um nível de significância de 5%. Os resultados obtidos pelo microscópio confocal mostraram que, de todos os corpos de prova modificados, os que receberam a Super Bonder® em sua superfície, G2(SBAE) e G3(SBDE) foram os únicos que significativamente reduziram a formação de biofilme de Candida albicans. Através da análise das imagens geradas pelo microscópio confocal, pôde-se observar que nos grupos G2(SBAE) e G3(SBDE) os campos apresentaram um reduzido número de células fúngicas e a maioria se encontrava na forma de levedura (inócua), enquanto que, para os demais grupos, além de observado um elevado número de células, a maioria destas se apresentava em forma de hifa (patogênica). Desse modo, a partir das condições experimentais desse estudo pôde-se concluir que as modificações do material testado com a Super Bonder® aplicada em sua superfície podem ser uma abordagem potencialmente útil para reduzir ou controlar a formação do biofilme em resinas acrílicas. / The purpose of this study was to verify, using the confocal laser scanning microscopy (CLSM), if the use of a photoactivated resin of low viscosity (Biscover®) and a ethyl-cyanoacrylate (Super Bonder®) could be efficient in the prevention or reduction of Candida albicans biofilms. Fifty six reline resin specimens (New Truliner) were fabricated and randomly divided into 7 groups: G1 (C)- Control; G2 (SBAE)- a Super Bonder® layer was applied on the surface before sterilization; G3 (SBDE)- the surface received a Super Bonder® layer after sterilization; G4 (SB3G)- 3 drops of Super Bonder® were incorporated in the structure of the resin; G5 (SB4G)- 4 drops of Super Bonder® were incorporated in the structure of the resin; G6 (BCDE)- a Biscover® layer was applied on the surface after sterilization; G7 (BCAE) the surface received a Biscover® layer before sterilization. All the specimens were inoculated with Candida albicans for biofilm dvelopment. The remaining biofilms on the specimens were stained with fluorochromes SYTO-9 and propidium iodide to be analyzed by CLSM. The data were statistically analyzed using the Kruskal-Wallis and Dunn test, considering a significance level of 5%. The data obtained by CLSM revealed that of all specimens modified, those that received a Super Bonder® layer on their surface, G2(SBAE) e G3(SBDE), presented the better results, reducing Candida albicans biofilm formation. Analyzing the images produced by CLSM it was possible to see that groups G2(SBAE) e G3(SBDE) showed a reduced number of cells, and they were in a less phatogenetic form (Yeast), while the other groups showed a high number of cells in a more pathogenetic form (Hyphae). Considering the experimental conditions of this study we can conclude that the material modifications done with Super Bonder® on the surface could be an interesting way to prevent or control biofilm formation on acrylic resin.
97

Efeito da triazina nas propriedades mecânicas e formação de biofilme em resina acrílica e reembasadores de prótese / Antimicrobial activity of triazine added to denture materials on saliva-derived microcosms: microbiological efficacy and mechanical properties

Moraes, Aline Pinheiro de 01 April 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_Aline Pinheiro_Moraes.pdf: 846337 bytes, checksum: 66b01044077d89e98213868cd5b7582a (MD5) Previous issue date: 2011-04-01 / Candidiasis is the most common fungal infection in denture wearers. The association between Candida and denture base is directly related to the efficiency of this micro-organism to adhere and colonize these surfaces, which is an essential initial step for the development of denture-related stomatitis. Additionally, the use of denture liners has increased, with these materials more prone to microbial adhesion when compared with acrylic resin due to its higher surface roughness. These materials have demonstrated capacity to interact with oral micro-organisms.This important problem is the reason why several attempts have been made to develop biomaterials containing antifungal. Thus, the aim of this study was to investigate the potential antifungal activity of triazine added to acrylic resin and liners used in prosthodontics using microcosms biofilm model with saliva derived from patients with or without candidiasis, verifying its effectiveness in reducing microbial adherence and consequently reduce the incidence of Candida infections. The mechanical properties of the tested materials after the incorporation of triazine were also evaluated. We considered four commercially available materials (a microwave-cured acrylic resin and two soft denture liners and one hard denture liner) to which were added different concentrations of triazine (0; 2.5; 5.0 and 10%). The results indicated that no difference were found among triazine concentrations in acrylic resin flexural strength (p= 0.059). Triazine addition did not result in surface roughness changes, although all denture liners presented higher surface roughness compared with acrylic resin, while in general, SoftConfort presented the highest roughness (p<0.001). In general, 5 and 10% triazine addition resulted in more soluble materials. All materials presented increased water sorption with the addition of triazine (p<0.05), except for CoeSoft, where no change was observed. Candidiasis patient saliva presented higher counts of total micro-organisms (p= 0.0294) and total streptococci (p = 0.0008). Regarding materials, total streptococci, total micro-organisms and Candida counts were higher in CoeSoft (p<0.0001). Candida species counts was the same for both saliva donors (p>0.05). The addition of triazine did not result in decrease of total micro-organisms, total streptococci or Candida species in all materials tested (p>0.05). In conclusion, the addition of triazine to acrylic resin and denture liners in a complex biofilm model did not modify the development of biofilms in both patients with and without candidiasis / A candidíase é a infecção oral fúngica mais comum em usuários de próteses. A associação entre o microrganismo Candida e as bases das próteses está diretamente relacionada à eficiência deste microrganismo em aderir e colonizar estas superfícies, sendo esta a etapa inicial essencial para o desenvolvimento da estomatite induzida por prótese. Associado a isto, o uso de reembasadores para próteses tem aumentado, sendo estes materiais mais propensos à adesão microbiana quando comparados a resina acrílica devido a sua maior rugosidade de superfície. Além disso, estes materiais tem demonstrado capacidade de interagir com microrganismos bucais. Este importante problema tem levado a tentativa de desenvolvimento de diversos materiais contendo agentes antifúngicos. Assim, o objetivo deste estudo foi investigar o potencial antifúngico da triazina adicionada à resina acrílica e reembasadores utilizados em prótese dentária, através de um modelo de biofilme de microcosmos, com salivas derivadas de pacientes com ou sem candidíase, verificando sua efetividade em reduzir a adesão microbiana e, consequentemente, diminuir a incidência de infecções por Candida. Também avaliaram-se as propriedades mecânicas dos materiais testados após a incorporação da triazina. Foram considerados quatro materiais comercialmente disponíveis (uma resina acrílica ativada por energia de micro-ondas, dois reembasadores resilientes e um reembasador permanente), aos quais foram adicionadas diferentes concentrações de triazina (0; 2,5; 5,0 e 10%). Os resultados indicaram que não houve diferença (p = 0,059) entre as concentrações de triazina para a resina acrílica de micro-ondas no teste de resistência à flexão. Em relação a rugosidade de superfície, embora a adição de triazina não tenha levado ao aumento da rugosidade, os reembasadores apresentaram maior rugosidade que a resina acrílica, com o SoftConfort apresentando, em geral, a maior rugosidade (p<0,001). De maneira geral, quando adicionada triazina a 5,0 e 10%, todos os materiais tornaram-se mais solúveis e apresentaram aumento de sorção de água (p<0,05), a exceção do CoeSoft, que não mostrou diferença com a adição do composto químico. Houve diferença entre salivas, sendo que aquela proveniente de individuo com candidíase apresentou maiores contagens de microrganismos totais (p = 0,0294) e estreptococos totais (p = 0,0008). Em relação aos materiais, a contagem de estreptococos, microrganismos totais e espécies de Candida foi maior no CoeSoft (p<0,0001). Entretanto, a contagem de espécies de Candida foi igual entre os doadores (p>0,05). A adição de triazina não resultou em diminuição de microrganismos totais, estreptococos totais ou espécies de Candida em nenhum dos materiais testados (p>0,05). Como conclusão, a adição de triazina a resina acrílica e reembasadores utilizados para confecção de base e reembasamento de próteses em um modelo complexo de biofilme não modificou o desenvolvimento de biofilmes em ambos os pacientes com ou sem candidíase
98

Développement, validation expérimentale et optimisation des traitements acoustiques des nacelles de turboréacteurs sous hauts niveaux acoustiques

Laly, Zacharie January 2017 (has links)
Cette thèse porte sur le développement et la validation des traitements acoustiques performants pour les nacelles des turboréacteurs, l’étude et la modélisation des liners sous hauts niveaux acoustiques avec écoulement d’air rasant et l’optimisation des technologies et propriétés des liners pour une meilleure réduction du bruit. Un nouveau modèle d’impédance acoustique basé sur l’approche du fluide équivalent a été proposé pour les plaques micro-perforées couplées à une cavité d’air ou à un milieu poreux. Le modèle proposé a été validé numériquement et expérimentalement et l’effet des hauts niveaux de pression sur les caractéristiques acoustiques des liners a été démontré. Une analyse de sensibilité a été réalisée pour évaluer les impacts des paramètres entre autres le diamètre de perforation, l’épaisseur de la plaque, le taux de perforation, la profondeur de la cavité, la résistance par unité de surface de l’écran résistif, le niveau de pression et le nombre de Mach sur les propriétés acoustiques des liners à un et deux degrés de liberté ainsi que les liners avec écrans résistifs. La technologie des liners avec écrans résistifs intégrés dans la cavité d’air ou collés sur les plaques micro-perforées a été étudiée et la contribution des écrans dans l’amélioration des performances d’atténuation acoustique des liners a été démontrée numériquement et expérimentalement. Ensuite, on modélise les liners en incidence rasante en proposant une approche analytique basée sur le développement limité en séries de Taylor pour déterminer le nombre d’onde complexe d’une conduite acoustique traitée par les matériaux absorbants. Enfin, on étudie la réponse acoustique des liners en incidence oblique.
99

Diminuição de rejeição térmica em motores a combustão /

Santos, Wagner Matos January 2019 (has links)
Orientador: Marcelino Pereira do Nascimento / Resumo: Estudos recentes mostram tendência de desenvolvimento de sistemas capazes de recuperar energia dos gases de escape. Apesar de ser de fato uma fonte de energia, os sistemas para recuperação instalados na linha de exaustão mostram grande complexidade e necessidade de muito espaço de instalação. O presente estudo demonstra a viabilidade de recuperação de energia do sistema de arrefecimento com espaço de instalação reduzido. O estudo propõe a geração de vapor através de perfis instalados nas paredes da câmara de combustão e sua aplicação em um ciclo Rankine para gerar trabalho através de expansor. A simulação realizada com o software GT-Power demonstra a possibilidade de extrair calor das câmaras com a mesma eficiência de um sistema convencional de arrefecimento por água e aditivo. Paralelamente, o estudo propõe um sistema de recirculação de gases de exaustão sem o uso de um trocador de calor, patenteado pela empresa patrocinadora, complementando a estratégia para evitar o uso desnecessário de energia em um motor a combustão. Os gases provenientes da linha de baixa pressão da exaustão são admitidos pela linha de ar limpo, em alta pressão, através do uso de uma válvula Laval. Os resultados são provenientes de uma rotina de cálculo em Excel, base VBA. O sistema permite que os gases fluam por fora da turbina e elimina a necessidade de um trocador de calor, resolvendo o maior problema dos sistema convencionais de recirculação de gases em baixa pressão. A combinação das duas soluções,... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
100

COD fractionation of wastewater on cruise liners before and after advanced treatment

Ekström, Karin, Borg, Jenni January 2015 (has links)
The purpose of this Bachelor thesis was to establish a method for determining the chemical oxygen demand (COD) fractionation in wastewater from cruise liners. COD fractions of interest were soluble biodegradable (SS), particulate biodegradable (XS), soluble unbiodegradable (SI) and particulate unbiodegradable (XI). Three types of wastewater (gray water, black water and permeate) were analysed and a method with a physiochemical approach was established. The method was originally elaborated by Jun Wu et al in the study “Wastewater COD biodegradability fractionated by simple physical–chemical analysis” (2014) Chemical Engineering Journal[ES1] [JB2]  258, p 450-459. The method was also used for comparison reasons of the COD fractionation in permeate before and after advanced treatment with nanofiltration and ozonation. Total COD in permeate was almost half of the initial value after nanofiltration and XI was eliminated. After ozonation no significant difference was observed neither in total COD concentration or fractionation pattern. The conclusion is that this method to determine the COD fractions has potential but it needs further optimization in form of adjusting the methods matrix specifically based on wastewater from cruise liners. / NAUTEK

Page generated in 0.0511 seconds