• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 111
  • 2
  • 1
  • Tagged with
  • 114
  • 114
  • 59
  • 59
  • 45
  • 44
  • 42
  • 41
  • 33
  • 19
  • 17
  • 16
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Análise e Desenvolvimento de um Filtro alfa-beta para Medição Indireta de Sistemas Dinâmicos de Primeira Ordem / Analysis and Development of a Filter alpha-beta stop Indirect measurement of Dynamic Systems of First Order

Oliveira, Jaderson Pereira 18 April 2006 (has links)
Made available in DSpace on 2016-08-17T14:52:54Z (GMT). No. of bitstreams: 1 Jaderson Pereira Oliveira.pdf: 404370 bytes, checksum: cdd98c0292ea8584c4aca3a5c5006d3a (MD5) Previous issue date: 2006-04-18 / We present in this work the development of an α-β filter for indirect measurement in 1st order dynamic systems, derived from the known equations for the α-β filter applied to systems with a pure integer. The main α-β filter design parameters analyzed are: the variance reduction factor of the measurement noise and the total transient error for a step input. Further, we present the development of the equations for the calculation of a critically dumped filter. As example of application, we use the concepts developed for the design of an α-β filter for the indirect measurement of the oxygen up-take rate in activated sludge systems in a dissolved oxygen feedback configuration, which can be viewed as a 1st order system. Simulations and comparisons with other methods are carried out in order to illustrate the proposed formulations. / Neste trabalho, apresenta-se o desenvolvimento do filtro α-β para medição indireta em sistemas dinâmicos de 1ª ordem a partir das equações conhecidas do filtro α-β aplicados a sistemas com um integrador puro. Os principais parâmetros de projeto do filtro analisado são: o fator de redução de variância do ruído de medição e o erro total de transitório para uma entrada do tipo degrau. Além disso, apresenta-se o desenvolvimento das equações para o cálculo de um filtro criticamente amortecido. Como exemplo de aplicação, utiliza-se os conceitos desenvolvidos para o projeto de um filtro α-β para medição indireta da taxa de consumo de oxigênio em sistemas de tratamento de esgotos de lodo ativado em uma configuração de realimentação da concentração de oxigênio dissolvido, o qual pode ser considerado um sistema de 1ª ordem. Simulações e comparações com outros métodos são apresentadas de forma a ilustrar a formulação proposta.
112

[pt] AVALIAÇÃO DA UTILIZAÇÃO DE LODO ATIVADO E DO PROCESSO DE OZONIZAÇÃO NA REMEDIAÇÃO DE ÁGUAS SUBTERRÂNEAS ORIUNDAS DE SISTEMAS PUMP AND TREAT / [en] EVALUATION OF ACTIVATED SLUDGE USE AND OZONATION PROCESS IN REMEDIATION OF GROUNDWATER DERIVED FROM PUMP AND TREAT SYSTEMS

RAPHAEL GONCALVES RIEBOLDT OLIVEIRA 19 October 2016 (has links)
[pt] Em função do crescente número de área contaminadas, identificadas nos grandes centros urbanos, é de crucial importância a evolução e o desenvolvimento dos processos relacionados ao tratamento destes locais, visando reduzir os riscos à saúde humana e ao meio ambiente, associados à presença dos contaminantes no meio subterrâneo. A presente dissertação tem como objetivo principal avaliar a eficiência de diferentes técnicas processuais, que poderiam ser aplicadas no tratamento de águas subterrâneas contaminadas, incluindo a ozonização e o uso de lodo ativado. Para isso, foram realizados ensaios de tratabilidade no laboratório do Institute of Sanitary and Environmental Engineering, da Universidade Técnica de Braunschweig, na Alemanha, os quais foram divididos em 3 etapas. A primeira etapa consistiu de um tratamento de caráter biológico, utilizando apenas o lodo ativado, coletado em estações de tratamento de efluentes sanitários, para a degradação de compostos orgânicos presentes em efluentes, artificiais e industriais, que simularam um efluente oriundo de um sistema de tratamento de uma área contaminada. A segunda etapa utilizou como técnica de tratamento, para o mesmo efluente, a ozonização, promovendo assim a oxidação química dos contaminantes. Por fim, foi utilizada uma combinação dos dois processos, sendo realizada a ozonização do efluente antes da degradação biológica. O objetivo desta etapa foi avaliar o incremento da biodegradabilidade do efluente por meio da ozonização. Os resultados obtidos indicaram, além da remoção da cor do efluente, uma efetiva redução dos valores de DQO, quando combinadas as duas técnicas de tratamento, sugerindo que a combinação das mesmas pode ser uma boa alternativa para o tratamento de efluentes de alta complexidade. / [en] Given the growing number of contaminated sites identified in large urban areas, it is of crucial importance the evolution and development of treatment processes for these sites, targeting the reduction of environmental and human health risks related to soil and groundwater contamination. The main goal of this dissertation is to evaluate the efficiency of various processing methods that could be applied in the treatment of contaminated groundwater, including the ozonation and activated sludge utilization. For that, jar tests were conducted in the laboratory of Institute of Sanitary and Environmental Engineering, at Braunschweig Technical University, in Germany, in three steps. The first step performed a biological treatment utilizing the activated sludge only which was collected from sewage treatment plants for the biodegradation of organic compounds present in effluents, both artificial and industrial, which simulated the effluent from a contaminated site treatment system. The second step utilized as treatment method, for the same effluent, an ozonation process, promoting the chemical oxidation of the contaminants. At last, a combination of both methods was tested where the ozonation was done prior to the biodegradation. The objective of this step was to evaluate the additional results of the biodegradation of the effluent when an ozonation process is done first. The results showed, in addiction of the color removal from the effluent, a larger reduction of DQO when both techniques are combined, suggesting that the combination can be a good alternative for treatment of high complexity wastewater.
113

ESTIMAÇÃO DA TAXA DE CONSUMO DE OXIGÊNIO EM SISTEMAS DE LODO ATIVADO USANDO FILTRO DE KALMAN E CONTROLE PWM DA CONCENTRAÇÃO DE OXIGÊNIO DISSOLVIDO / ESTIMATION OF THE RATE OF OXYGEN CONSUMPTION IN ACTIVATED SLUDGE SYSTEMS USING KALMAN FILTER AND PWM CONTROL OF THE CONCENTRATION OF DISSOLVED OXYGEN

Silva, Francisco Jadilson dos Santos 29 July 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:17Z (GMT). No. of bitstreams: 1 Francisco Jadilson dos Santos Silva.pdf: 1437166 bytes, checksum: 723ebc6c8bde855f26e3c823527ecdcf (MD5) Previous issue date: 2011-07-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The measurement and utilization of the oxygen uptake rate (OUR), or respiration rate, is very important in biological wastewater treatment process. The OUR provides information about the biological activity and may indicate the presence of the toxic elements capable of corrupting the system. Due to the lack of reliable real time sensors for measurement of the respiration rate, computer codes, based on estimation techniques, have been used to develop software sensors to overcome such difficulties. In this work a software sensor, using a Kalman Filter algorithm, is developed to estimate the OUR in an aerobic reactor, in which the dissolved oxygen concentration is controlled by aerators of on-off type triggered by pulse width modulation. Simulations and experimental results performed in a bench-scale activated sludge reactor are compared. It follows from the analysis of results, that the proposed method is able to estimate the OUR reliably and in real time. / A medição e a utilização da taxa de consumo de oxigênio (TCO), ou taxa de respiração, é muito importante para os processos biológicos de tratamento de águas residuais. A TCO fornece informações a respeito da atividade biológica e pode indicar a presença de elementos tóxicos capazes de comprometer a unidade de tratamento. Devido à carência de sensores confiáveis e em tempo real para a medição da taxa de respiração, programas de computador, baseados em técnicas de estimação, têm sido aplicados no desenvolvimento de sensores por software como uma alternativa para superar tais dificuldades. Neste trabalho um sensor por software, utilizando um algoritmo de Filtro de Kalman, é desenvolvido para estimar a TCO em um reator aeróbio no qual a concentração de oxigênio dissolvido é controlada por meio aeradores do tipo liga-desliga acionados por modulação por largura de pulsos. Simulações e resultados experimentais, obtidos em um reator de lodo ativado em escala de bancada, são comparados. Conclui-se, a partir da análise dos resultados, que o método proposto é capaz de estimar a TCO de forma confiável e em tempo real.
114

IDENTIFICAÇÃO DE UM SISTEMA DE LODO ATIVADO DE PEQUENA ESCALA DESENVOLVIDO EM LABORATÓRIO / IDENTIFICATION OF A ACTIVATED SLUDGE SYSTEM ON SCALE SMALL DEVELOPED IN THE LABORATORY

Lima, Freud Sebastian Bach Carvalho 29 July 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:17Z (GMT). No. of bitstreams: 1 Freud Sebastian Bach Carvalho Lima.pdf: 1668786 bytes, checksum: 953b0905b2e9bcd1cefb5702b8c6b362 (MD5) Previous issue date: 2011-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In activated sludge systems, the dissolved oxygen is used by microorganisms to decompose organic matter and treatment of wastewater. In these systems the dynamics of dissolved oxygen has been seen as the main source of information to obtain online information about the treatment process. Thus, the development of an appropriate model for the dynamics of dissolved oxygen and estimation of the parameters of this model can improve the quality of the estimates of process parameters and, consequently, the measurement system. In this study, a model of the bench-scale reactor is developed considering the dynamics associated with the operation of the aeration system and the dissolved oxygen sensor. The aeration system consists of air pumps with two operating states: on or off, and dissolved oxygen measurement is made by electrochemical cell based on Clark. Approach was used identification systems in continuous time and state variable filters with the least squares estimator for estimating the parameters of the model developed. Simulations and experimental results, using a bench scale reactor developed in the laboratory, are presented to illustrate the proposed model. / Em sistemas de lodo ativado, o oxigênio dissolvido é utilizado por microorganismos para decomposição de matéria orgânica e tratamento de água residuárias. Nestes sistemas, a dinâmica de oxigênio dissolvido tem sido vista como a principal fonte de informação para obtenção de informações online sobre o processo de tratamento. Com isso, o desenvolvimento de um modelo apropriado para dinâmica do oxigênio dissolvido e a estimação dos parâmetros deste modelo, pode melhorar a qualidade das estimativas dos parâmetros do processo e, consequentemente, do sistema de medição. No presente trabalho, um modelo do reator em escala de bancada é desenvolvido considerando as dinâmicas relacionadas com a operação do sistema de aeração e com o sensor de oxigênio dissolvido. O sistema de aeração é composto por bombas de ar com dois estados de operação: ligada ou desligada, e a medição de oxigênio dissolvido é realizada por sensor eletroquímico baseado em célula de Clark. Usa-se abordagem de identificação de sistemas em tempo contínuo e filtros de variável de estado junto com o estimador dos mínimos quadrados para estimação dos parâmetros do modelo desenvolvido. Simulações e resultados experimentais, utilizando um reator em escala de bancada desenvolvido no laboratório, são apresentados para ilustrar o modelo proposto.

Page generated in 0.0868 seconds