• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 7
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Jämförelse mellan Grocotts manuella och automatiserade färgningsmetod

Kurt, Nour, Sohlé, Jonna January 2017 (has links)
Grocott metoden är den känsligaste metoden för infärgning av svampstrukturer i histologisk vävnad i jämförelse med till exempel Periodic Acid-Schiff (PAS). Handhavandet av det cancerogena oxidationsmedlet kromsyra samt tidsaspekten för Grocott är signifikanta problem. Syftet med studien var att undersöka om den automatiserade färgningsmetoden för Grocott ger likvärdiga resultat som vid den manuella färgningsmetoden. Tolv preparat färgades med både den manuella och den automatiserade metoden för Grocott. Den automatiserade färgningsmetoden använder ett färdigt kit med alla ingående lösningar. Visuell bedömning av preparaten utfördes med hjälp av legitimerade biomedicinska analytiker samt en patolog. Svampstrukturer i åtta av ela preparat samt kontroll bedömdes vara tydligare infärgade med den automatiserade metoden i färhållande till den manuella. Svampstrukturer i endast ett preparat bedömdes vara tydligare infärgade med den manuella metoden. Resterande två preparat visade inga svampstrukturer. Resultaten tyder på att den automatiserade färgningsmetoden för Grocott ger likvärdiga, alternativt tydligare infrägning av svampstrukturer i jämförelse med den manuella metoden. / The Grocott method is the most sensitive staining method for fungal structures in histological tissues in comparison to for example Periodic Acid-Schiff (PAS). Usage of the cancerogenic chromic acid and the time aspect for Grocott are significant problems. The aim of this study was to examine if the automated staining method for Grocott provides equivalent results in comparison to the manual staining method. Twelve tissue sections were stained with both the automated and the manual method. The automated method contains a kit with all solutions. Visual evaluation was conducted with authorized biomedical scientists and a pathologist. Fungi structures in eight of eleven tissue sections and a control were evaluated as more distinct in the automated method in comparison to the manual method. Fungal structures in one of the tissue sections were evaluated more distinct in the manual method. In the remaining two tissue sections, no fungal structures were identified. Results from this study indicates that the automated staining method for Grocott provides equally, alternatively more distinct fungal staining in comparison to the manual method.
12

Optimering av vätskekromatografiska parametrar vid kvantifiering av läkemedel i serum med LC-MS/MS för klinisk diagnostik / Optimizing Chromatographic Parameters for Quantification of Pharmaceuticals in Serum with LC-MS/MS for Clinical Use

Edlund, Sofie January 2021 (has links)
Vid Klinisk kemi och farmakologi, Specialkemi, vid Skånes universitetssjukhus, Lund, utförs kvantifiering med LC-MS/MS av antipsykotiska och antidepressiva läkemedelskoncentrationer i serum med acetonitril (ACN) som mobilfas. ACN är på grund av sin höga elueringsstyrka ett av de vanligaste organiska lösningsmedlen vid reversed phase (RP) kromatografi, men uppvisar samtidigt en hög toxicitet med risk för stora leveransproblem. I syfte att reducera mängden ACN undersöktes därför möjligheten till ett mobilfasbyte till metanol (MeOH). Ordinarie metod jämfördes med tre nyutvecklade metoder med MeOH-baserad mobilfas. I en av metoderna ändrades endast mobilfas och elueringsgradient, medan två av metoderna även använde andra sorters RP-kolonner med anpassade elueringsgradienter. Samtliga analyter uppvisade godkänd separation och retention vid eluering med MeOH, men stor fluktuation från referensmetod sågs vid kvantifieringen av flera analyter, däribland olanzapin, desmetylolaznapin och mirtazapin. Liknande avvikelser med avseende på regression och kvantifieringsdifferens observerades vid eluering med andra sorters RP-kolonner. Detta indikerar att vidare optimering av andra vätskekromatografiska och masspektrometriska parametrar bör utföras innan metoderna kan valideras. / The quantification of antipsychotics and antidepressants in human serum with LC-MS/MS is usually performed with acetonitrile (ACN) as mobile phase. ACN is one of the most common organic solvents in reversed phase (RP) chromatography thanks to its high elution strength but is also highly toxic and can at times suffer from major delivery problems. The present study investigated the possibility of replacing ACN with methanol (MeOH) as primary organic solvent with the purpose of reducing the total ACN-usage. Three newly developed methods for chromatographic analysis of antipsychotic and antidepressant drugs using MeOH as organic solvent as part of the mobile phase were compared to the routine method in regard to analyte separation and retention, as well as the relative quantification of substance. In one of the methods only the mobile phase and elution gradient was changed whereas different types of RP columns were applied in addition to the changed mobile phase in the other two. All substances showed acceptable separation and retention when eluted with MeOH but displayed large fluctuations in the quantification of the analyzed substances, more specifically olanzapine, desmethylolanzapine and mirtazapine, in comparison to the reference method. Similar deviations in terms of regression and quantification bias were observed when analytes were eluted with MeOH through other types of RP columns. This indicates that further optimization of other parameters relating to the chromatography and mass spectrometer should be performed before validation.
13

Kan hemprovtagning ge likvärdiga resultat som sedvanlig provtagning vid analys av F-Kalprotektin med Phadia?

Petersson, Marcus January 2021 (has links)
Kalprotektin är ett protein som bygger upp 60 % av neutrofila granulocyters granula. Vid inflammationer i tarmen vandrar neutrofila granulocyter ut genom mukosan och följer med faeces ut ur kroppen. Proteinet är kalciumbindande och surt och dessa egenskaper utnyttjas i moderna extraktionskit för att mäta mängden kalprotektin i faeces (F-kalprotektin). Thermofisher är ett företag som utvecklat en metod för analys av F-kalprotektin och den kallas för EliA Extraction kit 2 där Kalprotektin extraheras med hjälp av bufferten i röret och analyseras därefter av Phadia 250. Syftet med studien var att utföra en metodjämförelse mellan två metoder. I den första metoden kommer den rutinmetod som används på laboratoriet användas för att upparbeta faeces. I den andra kommer patienterna som skickar sin faeces direkt samlade i extraktionsrören till analys. Syftet är att jämföra analysresultaten för att se om de är lika. Studien utfördes på 26 vuxna patienter varav 11 var kvinnor och 15 var män. Innan analys av prover analyserades tre kontroller för att kontrollera om metoden för analys av F-kalprotektin fick analyseras. Under studien utfördes fyra olika inom-serie precision på fyra olika patienter med 25 replikat för att beräkna variationskoefficienten (CV). Metodens CV varierade mellan 19 - 27 %. Efter att en reparation på instrumentet utförts analyserades två prover med inom-serie precision och CV blev 8 – 13 %. Metodernas resultat hade stark korrelation (R = 0,9055) och vid beräkning av resultat med Mann-Whitney U-test sågs ingen signifikant skillnad (p = 0,3059). Det fanns dock en del prover som hade stor skillnad på resultatet vilket kan ge fel diagnos/klassning. För att kunna bedöma om den nya metoden kan användas som ett alternativ till rutinmetoden måste en större population analyseras. / Calprotectin is a protein that makes up 60 % of the granules of neutrophilic granulocytes. In inflammation of the intestine, neutrophilic granulocytes migrate out through the mucosa and follow the feces out of the body. The protein is calcium-binding and acidic and these properties are used in modern extraction kits to measure the amount of calprotectin in feces  (F-calprotectin). Thermofisher is a company that has developed a method for analysis of F-calprotectin and it is called EliA Extraction kit 2 which is analyzed by Phadia 250. The purpose of the study was to perform a method comparison between two methods. In the first method, the routine method used in the laboratory will be used to process feces. In the second, the patients who send their feces directly collected in the extraction tubes come for analysis. The purpose is to compare the analysis results to see if they are similar. The study was performed on 26 individuals of which 11 were women and 15 were men. Before analyzing, three controls were analyzed to check the method of analysis of F-calprotectin. A negative check and a positive check as well as a calibration check. During the study, four different within-run precision were performed on four different patients with 25 replicates to calculate the coefficient of variation (CV). The CV of the method varied between 19 – 27 %. After a repair on the instrument was performed, the CV was 8 – 13 %. The results of the methods had a strong correlation (R = 0.9055) and when calculating the results with Mann-Whitney U-test, no significant difference was seen (p = 0.3059). In order to be able to assess whether the new method can be used as an alternative to the routine method, a larger population must be analyzed.

Page generated in 0.0648 seconds