Spelling suggestions: "subject:"multifásico"" "subject:"multifásicos""
1 |
Modelo de comportamento termodinâmico de uma bomba multifásica do tipo duplo parafuso. / Thermodynamic model of a twin-screw multiphase pump.Celso Yukio Nakashima 04 December 2000 (has links)
Esse trabalho apresenta um modelo termodinâmico de uma bomba multifásica do tipo duplo parafuso. Para uma dada condição de operação, o modelo calcula a potência consumida, as condições do fluido na descarga e o perfil de pressão ao longo da bomba. Ao invés de simular diretamente o escoamento dentro da bomba, simulou-se os processos que ocorrem dentro das suas câmaras. Para tanto, dividiu-se o processo de bombeamento multifásico em uma seqüência de processos simples, facilitando-se a construção do modelo no simulador de processos Hysys.Process v2.1. Os resultados de potência e temperatura de descarga obtidos com a simulação mostram uma boa concordância com valores experimentais, principalmente para FVGs baixos. Para FVGs elevados, o modelo passa a superestimar a potência consumida indicando que as fendas, nesses casos, já não se encontram totalmente preenchidas com líqüido. Dos resultados obtidos para o refluxo, conclui-se que, das equações sugeridas na literatura, aquelas para escoamento turbulento liso são mais adequadas para os números de Reynolds envolvidos. O perfil de pressão e a vazão de refluxo quando o escoamento é multifásico aproxima-se qualitativamente das medições experimentais. Estudou-se a influência de diversos parâmetros na eficiência exergética da bomba. Os resultados mostram que a otimização da eficiência depende das condições de operação da bomba: FVG, tipo de líqüido, diferença de pressão, entre outros. / The goal of this project was to develop a thermodynamic model of a twin-screw multiphase pump. With given operation conditions the model can determine the absorbed power, discharge conditions and the pressure profile along the screw. An alternative approach was suggested to overcome the complex flow problem and the processes inside the pump were simulated instead of direct simulation of the flow. For this purpose, the multiphase pumping process was divided in a sequence of simple processes so the model could be developed in an easier way. The power and temperature values calculated by the model are in good agreement with experimental data, mainly when the gas fraction is low. With higher gas fractions, the model overestimates the absorbed power indicating that screw gaps are not completely filled with liquid anymore. Concerning about the backflow rate, the results show that the equations for turbulent flow in smooth ducts fits better the Reynolds number range in the gaps. The pressure profile and backflow rate for multiphase flow agree qualitatively with experimental results. The influence of several parameters in the exergetic eficiency of the pump were analysed and results show that the efficiency optimization depends on pump operation conditions: gas fraction, liquid type, pressure difference and others.
|
2 |
Modelo de comportamento termodinâmico de uma bomba multifásica do tipo duplo parafuso. / Thermodynamic model of a twin-screw multiphase pump.Nakashima, Celso Yukio 04 December 2000 (has links)
Esse trabalho apresenta um modelo termodinâmico de uma bomba multifásica do tipo duplo parafuso. Para uma dada condição de operação, o modelo calcula a potência consumida, as condições do fluido na descarga e o perfil de pressão ao longo da bomba. Ao invés de simular diretamente o escoamento dentro da bomba, simulou-se os processos que ocorrem dentro das suas câmaras. Para tanto, dividiu-se o processo de bombeamento multifásico em uma seqüência de processos simples, facilitando-se a construção do modelo no simulador de processos Hysys.Process v2.1. Os resultados de potência e temperatura de descarga obtidos com a simulação mostram uma boa concordância com valores experimentais, principalmente para FVGs baixos. Para FVGs elevados, o modelo passa a superestimar a potência consumida indicando que as fendas, nesses casos, já não se encontram totalmente preenchidas com líqüido. Dos resultados obtidos para o refluxo, conclui-se que, das equações sugeridas na literatura, aquelas para escoamento turbulento liso são mais adequadas para os números de Reynolds envolvidos. O perfil de pressão e a vazão de refluxo quando o escoamento é multifásico aproxima-se qualitativamente das medições experimentais. Estudou-se a influência de diversos parâmetros na eficiência exergética da bomba. Os resultados mostram que a otimização da eficiência depende das condições de operação da bomba: FVG, tipo de líqüido, diferença de pressão, entre outros. / The goal of this project was to develop a thermodynamic model of a twin-screw multiphase pump. With given operation conditions the model can determine the absorbed power, discharge conditions and the pressure profile along the screw. An alternative approach was suggested to overcome the complex flow problem and the processes inside the pump were simulated instead of direct simulation of the flow. For this purpose, the multiphase pumping process was divided in a sequence of simple processes so the model could be developed in an easier way. The power and temperature values calculated by the model are in good agreement with experimental data, mainly when the gas fraction is low. With higher gas fractions, the model overestimates the absorbed power indicating that screw gaps are not completely filled with liquid anymore. Concerning about the backflow rate, the results show that the equations for turbulent flow in smooth ducts fits better the Reynolds number range in the gaps. The pressure profile and backflow rate for multiphase flow agree qualitatively with experimental results. The influence of several parameters in the exergetic eficiency of the pump were analysed and results show that the efficiency optimization depends on pump operation conditions: gas fraction, liquid type, pressure difference and others.
|
3 |
Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewaterPioltine, André 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).
|
4 |
Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewaterAndré Pioltine 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).
|
5 |
Modelagem e simulação de uma bomba multifásica de duplo parafuso com recirculação interna. / Modeling and simulation of a twin screw multiphase pump with internal recirculation.Ramirez Duque, Jose Luis Gerardo 09 September 2016 (has links)
As crescentes exigências sobre o desempenho de sistemas de bombeamento multifásico combinadas aos aspectos relacionados com a maior disponibilidade operacional desses sistemas, bem como as futuras condições de funcionamento atingindo pressões perto de 150 bar, destacam a importância de desenvolver modelos matemáticos precisos para prever o comportamento do desempenho nestes equipamentos. Nesta tese foi aperfeiçoado o modelo termo-hidráulico de uma bomba multifásica de tipo duplo parafuso desenvolvido por Nakashima (2005) e foram incluídos os efeitos da abertura gradual da última câmara, recirculação de líquido entre a sucção e descarga, transferência de calor através do liner e expansão térmica. Uma vez fornecidos os dados geométricos da bomba e as suas condições de operação, é possível calcular os parâmetros de desempenho mais importantes, como: eficiência volumétrica, vazão de sucção e refluxo, potência consumida e distribuição de pressão e temperatura. As equações implementadas foram desenvolvidas a partir dos balanços de massa e energia nas câmaras, tendo em conta a geometria da bomba e a variação das fendas durante sua operação. As rotinas e métodos necessários para a sua solução numérica foram implementadas utilizando programação orientada a objetos (C++). Os resultados fornecidos pelo modelo aperfeiçoado foram comparados com dados experimentais da literatura e uma boa concordância foi encontrada na faixa de até 95 % FVG, nos casos estudados, para bombas com e sem tecnologia de recirculação. Devido à complexidade dos fenômenos físicos envolvidos durante a operação da bomba, o impacto de cada um dos efeitos incorporados nos cálculos do modelo foi avaliado e discutido individualmente. Assim, foi demonstrada a grande influencia da recirculação, da abertura gradual da câmara de descarga e da expansão térmica nos cálculos dos parâmetros de operação mais importantes da bomba. Além disso, a transferência de calor pode ser considerada desprezível, já que seu valor é baixo quando comparado com a potência fornecida pela bomba e, portanto, não influencia os balanços de energia que determinam os estados termodinâmicos das câmaras. No entanto, esse efeito é necessário para calcular a distribuição de temperatura da bomba e a expansão térmica nos parafusos e no liner. / The increasing requirements about the performance of multiphase pumping systems combined with those related to a higher operational availability of such systems, as well as future operating conditions with pressure increase at about 150 bar, highlights the importance of developing accurate mathematical models to predict the performance behavior of these equipments. In this thesis it was improved the thermo-hydraulic behavior of a twin screw multiphase pump developed by Nakashima (2005), and were included the effects of the gradual opening of the last chamber, fluid recirculation between suction and discharge of the pump, heat transfer though the liner, thermal expansion and different working fluids (water-air and oil-gas). Giving pump geometry and operational conditions, it is possible to calculate the most important pump parameters performance, such as, volumetric efficiency, suction flow, back-flow, power consumption and pressure and temperature distribution. The model equations were developed based on mass and energy balances in the chambers taking into account the pump geometry and the clearance variation due to operation. Its implementation was made in C++. The results obtained by the new model were compared with experimental data of the bibliography, and a good accuracy was found in it with values till 95% GVF for the studied cases, with and without recirculation technology. Due to the physical phenomenon complexity related with the pump operation, the impact of each effect in the model calculations was evaluated and discussed separately. So, it was demonstrated the importance of the recirculation, the gradual opening of the last chamber and the thermal expansion in the calculation of the most important pump operation parameters. However, the heat transfer can be neglected, because its value is very low when compared with the pump power supply, and therefore, it does not influence the energy balances that determine thermodynamic state in the chambers. However, this effect is necessary to calculate the temperature distribution along the pump and the thermal expansion in the screws and the liner.
|
6 |
Avaliação da perfusão miocárdica por TC com 320 colunas de detectores e por PET com Rubídio na investigação da doença arterial coronariana / Myocardial perfusion in patients with suspected coronary artery disease: comparison between 320-MDCT and Rubidium-82 PETDantas Júnior, Roberto Nery 16 October 2017 (has links)
Introdução: Na investigação não invasiva da doença arterial coronariana (DAC), destacam-se a tomografia computadorizada com 320 colunas de detectores (TC320) e a tomografia por emissão de pósitrons com Rubídio-82 (PET82Rb), por suas elevadas acurácias. A avaliação por imagem da perfusional miocárdica (MPI) por TC é predominantemente estática, em razão das limitações associadas à radiação ionizante. Avanços tecnológicos, como a reconstrução iterativa, permitiram o desenvolvimento de novos protocolos de aquisição multifásica, com baixa exposição à radiação. Objetivos: Avaliar a concordância entre TC320 multifásica e PET82Rb na avaliação de MPI (visual e semiquantitativa), em repouso e sob estresse farmacológico, em pacientes de risco intermediário para DAC significativa. Como objetivo secundário, avaliar o protocolo da perfusão multifásica na TC320 quanto à segurança, qualidade de imagem e dose de radiação. Métodos: Entre junho e outubro de 2013, foram incluídos, consecutivamente, 45 pacientes com suspeita de DAC significativa referidos para PET82Rb sob estresse com dipiridamol no Departamento de Medicina Nuclear do InCor-HCFMUSP, realizando, posteriormente, a TC320 multifásica volumétrica (cinco fases sob estresse), em um intervalo de até 30 dias. Um paciente foi excluído por descontinuar o protocolo. Os 44 indivíduos tiveram seus escores perfusionais (SSS e SDS) e percentual de miocárdio isquêmico (%MI) calculados para comparação. A análise estatística foi realizada com o programa R. Resultados: A idade média foi 63 anos e o sexo feminino (64%) predominou. A hipertensão foi o principal fator de risco presente (91%), e angina foi o sintoma mais frequente (48%). Uma forte correlação entre os métodos para o SSS (r=0,76, p < 0,001) e moderada para %MI (r=0,64, p<0,001) foram encontradas. Houve alta concordância na identificação de SSS >= 4 (Kappa 0,77, IC 95% 0,55-0,98, p < 0,001) e moderada para SDS >= 2 (Kappa 0,51, IC 95% 0,23-0,80, p < 0,001). Na avaliação por segmento, a concordância foi elevada para identificação de déficits no estresse e no repouso (Kappa 0,75 e 0,82, respectivamente), sendo moderada para sua gravidade (Kappa 0,58 e 0,65, respectivamente). O protocolo multifásico foi diagnóstico, seguro, e com baixa dose de radiação total (9,28 mSv). Oito pacientes apresentaram sintomas, todos considerados leves. Conclusão: Houve concordância significativa entre MPI por TC320 e por PET82Rb na avaliação da DAC significativa em pacientes de risco intermediário. O protocolo de perfusão multifásica por TC320 mostrou-se seguro, diagnóstico e com baixa dose de radiação / Introduction: Coronary artery disease (CAD) assessment evolves towards high accuracy non-invasive techniques, such as 320-row MDCT (320-CT) and Rubidium-82 PET (82RbPET). The latter is well established for myocardial perfusion imaging (MPI) and quantitative measurements, while widespread clinical use of 320CT multiphase MPI has been hampered due to high radiation exposure. However, recent technology advances such as the development of iterative reconstruction algorithms made possible the research of new multiphase MPI protocols, with relatively low radiation burden. Objectives: The primary aim was to evaluate the agreement between 82RbPET MPI and contrast-enhanced 320-CT MPI using a multiphase first pass protocol during dipyridamole stress, in patients with suspected CAD. The secondary aim was to determine feasibility, image quality and radiation exposure of this new multiphase volumetric CT protocol. Methods: From June to October 2013 forty five patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82RbPET and multiphase 320-CT MPI protocol (five consecutive volumetric acquisitions during stress, and a single rest phase) within 30 days. One patient was excluded for discontinuing the protocol. Perfusional scores (SSS and SDS) and percent myocardium ischemic (%MI) for both methods were calculated for comparison, and statistical analyses were performed using the software R. Results: Mean age was 63 years old, and females were 64% of the sample. Hypertension was present in 91%, and chest pain was the predominant symptom in 48%. A strong correlation between methods regarding SSS was evidenced (r=0.76, p < 0.001), and moderate for %MI (r=0.64, p < 0.001). There was a high agreement for recognizing SSS >= 4 (Kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS >= 2 (Kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per-segment analysis, agreement was high for the presence of perfusion defects during both stress and rest (Kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (Kappa 0.58 and 0.65, respectively). The 320- CT protocol was safe, diagnostic and with low radiation burden (9.3 ± 2.4 mSv). Eight patients referred symptoms during the CT protocol, but those where mild and transient. Conclusions: There was a significant agreement between dipyridamole stress 320-CT MPI and 82RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure
|
7 |
Avaliação da perfusão miocárdica por TC com 320 colunas de detectores e por PET com Rubídio na investigação da doença arterial coronariana / Myocardial perfusion in patients with suspected coronary artery disease: comparison between 320-MDCT and Rubidium-82 PETRoberto Nery Dantas Júnior 16 October 2017 (has links)
Introdução: Na investigação não invasiva da doença arterial coronariana (DAC), destacam-se a tomografia computadorizada com 320 colunas de detectores (TC320) e a tomografia por emissão de pósitrons com Rubídio-82 (PET82Rb), por suas elevadas acurácias. A avaliação por imagem da perfusional miocárdica (MPI) por TC é predominantemente estática, em razão das limitações associadas à radiação ionizante. Avanços tecnológicos, como a reconstrução iterativa, permitiram o desenvolvimento de novos protocolos de aquisição multifásica, com baixa exposição à radiação. Objetivos: Avaliar a concordância entre TC320 multifásica e PET82Rb na avaliação de MPI (visual e semiquantitativa), em repouso e sob estresse farmacológico, em pacientes de risco intermediário para DAC significativa. Como objetivo secundário, avaliar o protocolo da perfusão multifásica na TC320 quanto à segurança, qualidade de imagem e dose de radiação. Métodos: Entre junho e outubro de 2013, foram incluídos, consecutivamente, 45 pacientes com suspeita de DAC significativa referidos para PET82Rb sob estresse com dipiridamol no Departamento de Medicina Nuclear do InCor-HCFMUSP, realizando, posteriormente, a TC320 multifásica volumétrica (cinco fases sob estresse), em um intervalo de até 30 dias. Um paciente foi excluído por descontinuar o protocolo. Os 44 indivíduos tiveram seus escores perfusionais (SSS e SDS) e percentual de miocárdio isquêmico (%MI) calculados para comparação. A análise estatística foi realizada com o programa R. Resultados: A idade média foi 63 anos e o sexo feminino (64%) predominou. A hipertensão foi o principal fator de risco presente (91%), e angina foi o sintoma mais frequente (48%). Uma forte correlação entre os métodos para o SSS (r=0,76, p < 0,001) e moderada para %MI (r=0,64, p<0,001) foram encontradas. Houve alta concordância na identificação de SSS >= 4 (Kappa 0,77, IC 95% 0,55-0,98, p < 0,001) e moderada para SDS >= 2 (Kappa 0,51, IC 95% 0,23-0,80, p < 0,001). Na avaliação por segmento, a concordância foi elevada para identificação de déficits no estresse e no repouso (Kappa 0,75 e 0,82, respectivamente), sendo moderada para sua gravidade (Kappa 0,58 e 0,65, respectivamente). O protocolo multifásico foi diagnóstico, seguro, e com baixa dose de radiação total (9,28 mSv). Oito pacientes apresentaram sintomas, todos considerados leves. Conclusão: Houve concordância significativa entre MPI por TC320 e por PET82Rb na avaliação da DAC significativa em pacientes de risco intermediário. O protocolo de perfusão multifásica por TC320 mostrou-se seguro, diagnóstico e com baixa dose de radiação / Introduction: Coronary artery disease (CAD) assessment evolves towards high accuracy non-invasive techniques, such as 320-row MDCT (320-CT) and Rubidium-82 PET (82RbPET). The latter is well established for myocardial perfusion imaging (MPI) and quantitative measurements, while widespread clinical use of 320CT multiphase MPI has been hampered due to high radiation exposure. However, recent technology advances such as the development of iterative reconstruction algorithms made possible the research of new multiphase MPI protocols, with relatively low radiation burden. Objectives: The primary aim was to evaluate the agreement between 82RbPET MPI and contrast-enhanced 320-CT MPI using a multiphase first pass protocol during dipyridamole stress, in patients with suspected CAD. The secondary aim was to determine feasibility, image quality and radiation exposure of this new multiphase volumetric CT protocol. Methods: From June to October 2013 forty five patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82RbPET and multiphase 320-CT MPI protocol (five consecutive volumetric acquisitions during stress, and a single rest phase) within 30 days. One patient was excluded for discontinuing the protocol. Perfusional scores (SSS and SDS) and percent myocardium ischemic (%MI) for both methods were calculated for comparison, and statistical analyses were performed using the software R. Results: Mean age was 63 years old, and females were 64% of the sample. Hypertension was present in 91%, and chest pain was the predominant symptom in 48%. A strong correlation between methods regarding SSS was evidenced (r=0.76, p < 0.001), and moderate for %MI (r=0.64, p < 0.001). There was a high agreement for recognizing SSS >= 4 (Kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS >= 2 (Kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per-segment analysis, agreement was high for the presence of perfusion defects during both stress and rest (Kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (Kappa 0.58 and 0.65, respectively). The 320- CT protocol was safe, diagnostic and with low radiation burden (9.3 ± 2.4 mSv). Eight patients referred symptoms during the CT protocol, but those where mild and transient. Conclusions: There was a significant agreement between dipyridamole stress 320-CT MPI and 82RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure
|
8 |
Modelagem e simulação de uma bomba multifásica de duplo parafuso com recirculação interna. / Modeling and simulation of a twin screw multiphase pump with internal recirculation.Jose Luis Gerardo Ramirez Duque 09 September 2016 (has links)
As crescentes exigências sobre o desempenho de sistemas de bombeamento multifásico combinadas aos aspectos relacionados com a maior disponibilidade operacional desses sistemas, bem como as futuras condições de funcionamento atingindo pressões perto de 150 bar, destacam a importância de desenvolver modelos matemáticos precisos para prever o comportamento do desempenho nestes equipamentos. Nesta tese foi aperfeiçoado o modelo termo-hidráulico de uma bomba multifásica de tipo duplo parafuso desenvolvido por Nakashima (2005) e foram incluídos os efeitos da abertura gradual da última câmara, recirculação de líquido entre a sucção e descarga, transferência de calor através do liner e expansão térmica. Uma vez fornecidos os dados geométricos da bomba e as suas condições de operação, é possível calcular os parâmetros de desempenho mais importantes, como: eficiência volumétrica, vazão de sucção e refluxo, potência consumida e distribuição de pressão e temperatura. As equações implementadas foram desenvolvidas a partir dos balanços de massa e energia nas câmaras, tendo em conta a geometria da bomba e a variação das fendas durante sua operação. As rotinas e métodos necessários para a sua solução numérica foram implementadas utilizando programação orientada a objetos (C++). Os resultados fornecidos pelo modelo aperfeiçoado foram comparados com dados experimentais da literatura e uma boa concordância foi encontrada na faixa de até 95 % FVG, nos casos estudados, para bombas com e sem tecnologia de recirculação. Devido à complexidade dos fenômenos físicos envolvidos durante a operação da bomba, o impacto de cada um dos efeitos incorporados nos cálculos do modelo foi avaliado e discutido individualmente. Assim, foi demonstrada a grande influencia da recirculação, da abertura gradual da câmara de descarga e da expansão térmica nos cálculos dos parâmetros de operação mais importantes da bomba. Além disso, a transferência de calor pode ser considerada desprezível, já que seu valor é baixo quando comparado com a potência fornecida pela bomba e, portanto, não influencia os balanços de energia que determinam os estados termodinâmicos das câmaras. No entanto, esse efeito é necessário para calcular a distribuição de temperatura da bomba e a expansão térmica nos parafusos e no liner. / The increasing requirements about the performance of multiphase pumping systems combined with those related to a higher operational availability of such systems, as well as future operating conditions with pressure increase at about 150 bar, highlights the importance of developing accurate mathematical models to predict the performance behavior of these equipments. In this thesis it was improved the thermo-hydraulic behavior of a twin screw multiphase pump developed by Nakashima (2005), and were included the effects of the gradual opening of the last chamber, fluid recirculation between suction and discharge of the pump, heat transfer though the liner, thermal expansion and different working fluids (water-air and oil-gas). Giving pump geometry and operational conditions, it is possible to calculate the most important pump parameters performance, such as, volumetric efficiency, suction flow, back-flow, power consumption and pressure and temperature distribution. The model equations were developed based on mass and energy balances in the chambers taking into account the pump geometry and the clearance variation due to operation. Its implementation was made in C++. The results obtained by the new model were compared with experimental data of the bibliography, and a good accuracy was found in it with values till 95% GVF for the studied cases, with and without recirculation technology. Due to the physical phenomenon complexity related with the pump operation, the impact of each effect in the model calculations was evaluated and discussed separately. So, it was demonstrated the importance of the recirculation, the gradual opening of the last chamber and the thermal expansion in the calculation of the most important pump operation parameters. However, the heat transfer can be neglected, because its value is very low when compared with the pump power supply, and therefore, it does not influence the energy balances that determine thermodynamic state in the chambers. However, this effect is necessary to calculate the temperature distribution along the pump and the thermal expansion in the screws and the liner.
|
Page generated in 0.0317 seconds