• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 186
  • 40
  • 34
  • 10
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 387
  • 387
  • 82
  • 77
  • 65
  • 54
  • 43
  • 41
  • 37
  • 31
  • 30
  • 27
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Aplicação das metodologias feedback e feedforward no controle ativo do ruido transmitido por uma placa / Application of the feedback and feedforward methodologies to the active control of the noise transmitted through a plate

Siviero, Diego Azevedo 20 July 2007 (has links)
Orientadores: Jose Roberto de França Arruda, Juan Francisco Camino dos Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-09T13:00:18Z (GMT). No. of bitstreams: 1 Siviero_DiegoAzevedo_M.pdf: 1349512 bytes, checksum: dd6f2edf66df39c704de24d42a9ed55c (MD5) Previous issue date: 2007 / Resumo: Dado o contínuo processo de otimização ao no setor aeroespacial é cada vez mais priorizada nos projetos a busca pelo decréscimo de massa dos sistemas secundários ao vôo, como por exemplo, no sistema responsável pelo controle de ruídos internos. Isto tem provocado um aumento de interesse no desenvolvimento de placas inteligentes, ou ¿smart-plates¿, que consistem em elementos estruturais com atuadores e sensores agregados as suas superfícies, para o controle de suas próprias vibrações estruturais, possibilitando, no futuro, a redução nas dimensões dos elementos passivos de contenção de ruído hoje em uso, principalmente no trabalho com sinais de baixa freqüência. Cresce paralelamente a necessidade de se do definir qual a melhor estratégia de controle para estas estruturas inteligentes. Este estudo descreve a implementação de dois tipos distintos de controladores em uma placa de LEXAN com o objetivo de aumentar a perda transmissão de ruídos. O primeiro controlador utilizado é tipo H2, uma estratégia de controle que utiliza a realimentação da saída (feedback) como referencia para a ação de controle. O segundo controlador é o Filtered-X LMS, uma estratégia por alimentação direta (feedforward) que utiliza um sinal correlacionado ao distúrbio como referencia para o controle. A resposta da planta em malha fechada, com cada controlador, é medida por um microfone com a finalidade de s88e determinar o desempenho atingido pelas diferentes metodologias. Um enfoque maior será dado ao controlador Filtered-X LMS, que também será detalhado e aplicado a um sistema numérico de dutos / Abstract: Due to the continuous optimization process in the aerospace industry, the search for lighter secondary flight systems has been intensively investigated in recent years, for instance, the system responsible for the control of internal noise. This leads to a growing interest in the development of smart panels, which consist of structural elements with actuators and sensors attached to their surfaces, in order to control the structural vibration. This leads to a reduction of the members of passive elements used to attenuate noise mainly at low frequencies. The interest in these smart structures grows along with the necessity of defining the best control strategy. This thesis describes the implementation of two distinct controllers on a LEXAN smart plate, with the purpose of increasing the transmission loss. The first is an H2 dynamic output feedback controller, a strategy that uses the system's output as a reference to the control action. The second controller is the Filtered-X LMS, a strategy that uses a signal correlated with the disturbance as a reference to the control. The response of the closed-loop systems, using each controller, is measured using a microphone. This determines the performance achieved by the different methodologies. More emphasis will be given to the Filtered-X LMS controller, which is also applied to a vibroacoustic problem in a duct / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
232

Analise de redução do ruído de batida de dentes de engrenagem do compressor do motor Diesel / Diesel engine air compressor gear rattle noise reduction analysis

Glyniadakis, Georges Vretos 10 February 2009 (has links)
Dissertação (mestrado profissional)) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-15T22:59:51Z (GMT). No. of bitstreams: 1 Glyniadakis_GeorgesVretos_M.pdf: 4546733 bytes, checksum: 79710497f8d263afb43f905ddd4e41f4 (MD5) Previous issue date: 2009 / Resumo: Os requisitos de qualidade sonora estão sendo cada vez mais utilizados no mercado de caminhões médios e pesados. Assim, proprietários de veículos sentem-se incomodados pelo ruído de batida de dentes, principalmente na condição de motor na marcha lenta e o compressor de ar operando com carga. Algumas vezes o associam como falha, podendo até gerar reclamações na revenda bem como perda de qualidade na imagem do produto ou do fabricante. Uma opção para tratar este tipo de ruído é o uso de engrenagens com sistema de redução de folga. A literatura indica que conforme a folga é reduzida o ruído também é reduzido. Então entender o efeito desta solução é necessário antes de aplicá-la em produção. Sendo assim este trabalho tem por objetivo estudar o efeito vibroacustico da engrenagem com sistema de redução de folga automático no ruído de batida de dentes (rattle) relativo à engrenagem do compressor de ar do motor MWM ACTEON 4.12TCE. Um modelo analítico simplificado foi desenvolvido para verificar as oscilações dos deslocamentos angulares e velocidades da engrenagem do compressor. Estes resultados foram posteriormente confrontados com resultados experimentais. Também foram analisadas as respostas vibroacústicas do motor através de experimentos e seus efeitos em termos de qualidade sonora através de teste de júri / Abstract: Sound quality requirements have been more often used in light and heavy duty trucks market. Then, vehicle owners fell uncomfortable with rattle noise mainly at idle speed with air compressor operating in load phase. Sometimes they associate this noise as a failure, which can generate a car shop dealer claim, as well as product and company image deterioration. One option to deal with this kind of noise is to apply an anti-backlash gears. The literature shows that as we decrease the backlash the rattle is reduced too. Then, to understand the effect of this solution is mandatory before to apply into production. The object of this work is to study the vibroacoustics effects of the anti-backlash gear system regarding to the air compressor rattle noise of the MWM ACTEON 4.12TCE diesel engine. A simplified analytical model was developed in order to verify the angular displacement and velocities fluctuation of the air compressor anti-backlash gear. These results were compared with experimental ones. Experimental vibroacoustics responses were also analyzed in terms of sound quality jury test / Mestrado / Dinâmica / Mestre em Engenharia Mecânica
233

Níveis de ruído de incubadoras em situações experimentais de manejo: subsídios para o cuidado em unidades neonatais / Levels of noise in incubators in experimental handling situations: evidences for care in neonatal units.

Andreza Monforte Miranda 20 March 2009 (has links)
Introdução. Pensar nos efeitos nocivos do ruído aos recém-nascidos (RN) com saúde debilitada se torna cada vez mais necessário devido aos avanços tecnológicos, ao aumento da sobrevida dos RNs de baixo peso, com maiores períodos de hospitalização. Objetivo geral. Avaliar os níveis de ruído das incubadoras das unidades neonatais de um hospital universitário de Ribeirão Preto, SP, em situações experimentais de manejo. Método. Trata-se de estudo quantitativo do tipo quase-experimental, realizado com 20 incubadoras das unidades neonatais de um hospital universitário de Ribeirão Preto, SP, que se encontravam disponíveis durante o período de coleta de dados. O período de coleta foi de agosto a setembro de 2008. As incubadoras foram divididas em três grupos (1, 2, 3), conforme a marca, o modelo, tempo de uso e situação de manejo. As medidas foram realizadas sem a presença do RN, em uma sala afastada do fluxo rotineiro das unidades neonatais. Foi utilizado um dosímetro, modelo Quest 400, com o microfone fixado dentro da incubadora para mensurar o Nível de Pressão Sonora (NPS). Foram realizadas as mensurações dos níveis de ruído contínuo (funcionamento do motor, alarme soando, pulso oxímetro e bomba de infusão sobre a cúpula e seus alarmes) e de impacto (manipulação da portinhola e ato de colocar o frasco de álcool gel sobre a cúpula) nas incubadoras. Os ruídos de impacto foram analisados nos modos de manipulação cuidadoso e brusco. As medidas com o pulso oxímetro, bomba de infusão e o ato de colocar o frasco de álcool gel sobre a cúpula foram repetidas com a presença do cueiro sobre a cúpula da incubadora. Os valores mensurados de Leq, Lmax, Lmin dos ruídos contínuos e os valores de Lpeak dos ruídos de impacto foram analisados por meio dos valores medianos, mínimos e máximos. Resultados. Os valores medianos gerais dos três grupos encontrados para ruído contínuos foram: Leq de 55,2dBA para ruído de funcionamento das incubadoras; Leq 65,5dBA de para alarme da incubadora; para pulso oxímetro e alarme e bomba de infusão e seu alarme os Leq foram: 54,7dBA, 58,4dBA, 53,9dBA e 66,1dBA NPS, respectivamente. Com cueiro, os valores nessas situações foram: 54,0dBA, 57,8dBA, 55,1dBA e 61,7dBA NPS, respectivamente. Todos Lmax medianos de cada grupo nas situações anteriormente descritas estiveram acima de 65dBA e os Lmin acima de 47dBA. Os ruídos de manipulação alcançaram valores de Lpeak medianos gerais para os três grupos de 91,2dBA e 97,9dBA NPS para abrir a portinhola nos modos cuidadoso e brusco e 91,5dBA e 109,5dBA NPS ao fechar cuidadoso e brusco a portinhola, respectivamente. Os níveis atingidos ao colocar o álcool gel sobre a cúpula no modo cuidadoso com e sem cueiro variaram de 89dBA a 89,6dBA NPS e no modo brusco com e sem cueiro de 107dBA a 107,7dBA. Conclusão. Os níveis gerados pelas incubadoras e seus alarmes estão abaixo daquele recomendado pelas normas nacionais, mas acima da norma internacional. A presença de equipamentos sobre a cúpula e seus alarmes soando não intensificaram os níveis de ruído nas incubadoras, com exceção do alarme da bomba de infusão. Os níveis de ruído produzidos pela manipulação da incubadora e o ato de colocar o álcool gel sobre a cúpula foram intensos e o modo cuidadoso foi um recurso para diminuir os níveis sonoros. De um modo geral, o uso do cueiro não reduziu o ruído gerado pelos equipamentos sobre a cúpula e nem o ruído gerado pelo ato de colocar o álcool gel sobre a cúpula. / Introduction. Technological advances and increase in survivorship of low birth weight newborns (NB), with longer periods of hospitalization, make each time more necessary to think about the noxious effects of noise to NB with weak health. Objective. to evaluate levels of noise in incubators of neonatal units in experimental handling situations, in a university hospital in Ribeirão Preto, state of São Paulo, Brazil. Method. Quantitative quasiexperimental study, carried out in 20 incubators in neonatal units during the data collection period, from August to September 2008, in a university-hospital in Ribeirão Preto, SP. Incubators were divided into three groups (1,2,3), according to brand, model, usage time and handling situation. Measuring occurred when NB were not in incubators, in a room far from usual neonatal unit routine work. A Quest 400 dosimeter with microphone fixed inside incubator was used to measure Sound Pressure Level (SPL). Levels of continuous noise (motors functioning, alarm sound, pulse oximeter and infusion bombs on the incubator dome and their alarms) and impact noise (manipulation of incubators door and putting the bottle of alcohol gel on the dome) in incubators were measured. Impact noises were analyzed for careful and rough manipulation. Measures with pulse oximeter, infusion bomb and putting the bottle of alcohol gel on the incubator dome were repeated with a swathe placed on the dome. Continuous noise Leq, Lmax, Lmin and impact noise Lpeak values measured were analyzed using mean, minimum and maximum values. Results. General mean values found for continuous noise in the three groups were: Leq intensity of 55,2dBA for incubators functioning noise; Leq 65,5dBA for incubators alarm; for pulse oximeter, alarm, infusion bomb and infusion bombs alarm Leq were: 54,7dBA, 58,4dBA, 53,9dBA and 66,1dBA SPL, respectively. Using a swathe, values in the same situations were: 54,0dBA, 57,8dBA, 55,1dBA and 61,7dBA SPL respectively. All mean Lmax for each group in the previously described situations were over 65dBA and Lmin over 47dBA. Manipulation noises reached Lpeak general mean values for the three groups of 91,2dBA and 97,9dBA SPL for rough and careful opening of incubator door, and 91,5dBA and 109,5dBA SPL for careful and rough closing, respectively. Levels reached for putting alcohol gel on the incubator dome carefully, with or without swathe, varied from 89dBC to 89,6dBC SPL, and roughly, with or without swathe, varied from 107dBC to 107,7dBC. Conclusion. Noise levels generated by incubators and alarms are under national rules, but over international rules. The presence of equipments on the dome and the sound of incubator alarm do not increase the levels of noise in incubators, with exception of infusion bombs alarm. Noise levels produced by incubator manipulation and putting alcohol gel on the incubator dome are intense, careful mode was a way to decrease noise levels. In a general way, the use of a swathe did not reduce noise generated by the equipments on the dome neither noise of putting alcohol gel on the dome.
234

As tecnicas NASVD e MNF e sua aplicação na redução de ruidos em dados gamaespectrometricos : Francisco de Assis Cavallaro / NASVD and MNF methods applied for noise reduction in airborne gamma-ray spectrometry

Cavallaro, Francisco de Assis 26 August 2008 (has links)
Orientadores: Rodrigo de Souza Portugal, Adalene Moreira Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-11T23:11:38Z (GMT). No. of bitstreams: 1 Cavallaro_FranciscodeAssis_M.pdf: 3169392 bytes, checksum: 102911624b422474e306cc2cb62cdabd (MD5) Previous issue date: 2008 / Resumo: O processamento atual em gamaespectrometria necessita de novas ferramentas para auxiliar a remoção de ruídos, visto que ao final desta etapa há constatação de ruído remanescente. O ruído remanescente prejudica de forma expressiva os produtos finais. O decaimento radioativo é um processo aleatório e a estimativa de todas as medidas é governada por leis estatísticas. Os perfis de taxas de contagem são sempre "ruidosos" quando utilizados períodos curtos como um segundo para cada medida. Os filtros utilizados e, posteriormente, as correções efetuadas no processamento atual de dados gamaespectrométricos não são suficientes para remover ou diminuir consideravelmente o ruído oriundo do espectro. Dois métodos estatísticos que atuam diretamente nos dados coletados, isto é, nos espectros vêm sendo sugeridos na literatura para remover estes ruídos remanescentes: o Noise-Adjusted Singular Value Decomposition ¿ NASVD e Maximum Noise Fraction ¿ MNF. Estes métodos produzem uma redução no desvio padrão de forma significativa. Neste trabalho eles foram implementados dentro do ambiente de processamento do software OASIS MONTAJ e aplicados em uma área compreendida por dois blocos, I e II do levantamento aerogeofísico que recobre a porção oeste da Província Mineral do Tapajós - sudoeste do Estado do Pará e sudeste do Estado do Amazonas. Os dados filtrados e não-filtrados foram processados e comparados usando os coeficientes determinados pela empresa Lasa Engenharia e Prospecções S.A. Os resultados da comparação entre perfis e mapas apresentaram-se de forma promissora, pois houve um ganho na resolução dos produtos. / Abstract: The gamaespectrometry processing needs new tools to help the noise¿s removal, at the end of this step there are evidence of remaining noise; this remaining noise causes damages at the final product. The radioactive decline is a random process and the estimate of the measures is managed by statistical laws. The profiles of counting ratios are always noisy when analyzed for short periods, like a second for each measurement. Filters and corrections made in the airborne gamma-ray spectrometric data processing are not enough to remove or reduce the spectrum's noise. Two statistic methods which act directly at collected data, i.e., in the spectrum domain, the literature has been suggesting to remove such remaining noises, the Noise-Adjusted Singular Value Decomposition ¿ NASVD and Maximum Noise Fraction ¿ MNF. These methods produce a significant reduction in the standard deviation. In this work both methods were implemented in the software OASIS MONTAJ environment and applied in one area between two blocks, I and II of the airborne survey which covers the west area of Mineral Province of Tapajós ¿ southwest of Pará state and southeast of Amazonas state. The filtered and not filtered data were processed and compared using the coefficients determined by Lasa Engenharia e Prospecções S.A. The results of the comparison done, using maps and profiles showed up a promising form; therefore, these products had gained resolution. / Mestrado / Geologia e Recursos Naturais / Mestre em Geociências
235

Avaliação de atenuadores de ruido passivos resistivos para grupos geradores de energia / Evaluation of passive resistive silencers of noise for energy generators

Araujo, Nilza Maria Coradi de 12 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-12T06:49:31Z (GMT). No. of bitstreams: 1 Araujo_NilzaMariaCoradide_M.pdf: 13106007 bytes, checksum: 70f9cecd051bb62ae31e9b41e050b150 (MD5) Previous issue date: 2004 / Resumo: Esse trabalho tem por objetivo avaliar o desempenho acústico de atenuadores de ruído para grupos geradores de energia. Geradores de energia a diesel são equipamentos extremamente ruidosos e para tratar acusticamente um gerador é necessário, entre outras coisas, o tratamento das aberturas para ventilação. Essas aberturas são geralmente tratadas com atenuadores (silenciadores) de ruído .Existem vários tipos de silenciadores os mais comuns são os passivos resistivos que se caracterizam pelo uso de material absorvente nas paredes internas do duto. Os silenciadores objeto de estudo deste trabalho foram os dutos retangulares com células divisórias paralelas. Para a realização das medidas de desempenho acústico dos silenciadores foi utilizada a metodologia descrita na ISO 11 820 Acoustics - Measurements on Silencers in situo Essa norma apresenta dois parâmetros de avaliação de desempenho acústico: perda por transmissão e perda por inserção. Para realização da avaliação de desempenho acústico, foram construídos e testados 22 tipos diferentes de silenciadores, alterando as dimensões das lamelas, o tamanho do duto e a densidade e espessura do material absorvente. Os resultados das avaliações mostraram que a espessura das lamelas e o comprimento do duto têm uma maior influência na eficiência do atenuador do que a densidade do material absorvente. Realizou-se, ainda, uma análise comparativa entre eficiência e custo entre os silenciadores avaliados. Os resultados dessa analise permitiram estabelecer quais silenciadores que apresentaram a melhor relação custo benefício, isto é, melhor desempenho acústico e menor custo. / Abstract: The objective this work is to evaluate the acoustic performance of the silencers of noise for energy group generators. Generators of energy to Diesel are extremely noisy equipments. For acoustic treatment of a generator it is necessary, among other things, the treatment of the openings of ventilation. The openings are generally treated with silencers of noise. There are several types of silencers, the most common are the passive resistive. The passive resistive silencers are characterized by the use of absorbent material in the internal walls of the lined ducts. The silencer object of the study this work is the rectangular lined duct of the parallel bafflers. For the accomplishment of the measures of acoustic performance of the silencers was used the methodology described in ISO 11 820 Acoustics Measurements on Silencers in situ. The ISO 11 820 standard presents two parameters of evaluation of acoustic performance: transmission loss and insertion loss. For accomplishment of the evaluation of acoustic performance, were built and tested 22 types of different silencers, altering the dimensions of the bafflers the size of the duct and the density and thickness of the absorbent material. The results of the evaluations showed that the thickness of the bafflers and the length of the duct have a larger influence in the efficiency of the silencer than the density of the absorbent material. It was also made a comparative analysis between the efficiency and the cost among the appraised silencer. The results of that analyze allowed to establish which silencer that presented the best cost/benefit relation or the better acoustic performance and lower cost. / Mestrado / Edificações / Mestre em Engenharia Civil
236

Modelo em escala reduzida ao ar livre como ferramenta de validação de simulação computacional de barreiras acústicas / Scale outdoor models as validation tool for computer simulation of noise barriers

Lisot, Aline, 1980- 08 September 2013 (has links)
Orientador: Stelamaris Rolla Bertoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T15:55:45Z (GMT). No. of bitstreams: 1 Lisot_Aline_D.pdf: 22929481 bytes, checksum: b4a8e502fe551c84db705e90815efafe (MD5) Previous issue date: 2013 / Resumo: As barreiras acústicas têm sido empregadas como soluções de mitigação de ruído ambiental. O estudo sobre desempenho de barreiras acústicas é comumente realizado por meio de simulações computacionais em programas específicos de propagação sonora. Testes de modelos em escala reduzida efetuados em câmara anecóica também são ferramentas empregadas neste tipo de avaliação e podem auxiliar na validação do modelo computacional elaborado. A restrição de acesso a câmaras anecóicas e as grandes dimensões de algumas fontes sonoras, como é o caso de subestações elétricas, podem impossibilitar a realização de ensaios em tais câmaras e conduzir aos testes de modelos reduzidos ao ar livre. Estes testes são praticamente inexistentes na literatura, o que confere caráter original à pesquisa apresentada neste trabalho. No caso de subestações elétricas que porventura sejam causadoras de perturbação sonora no seu entorno, assinala-se a impossibilidade de implementação de soluções mitigadoras para posterior validação da solução empregada. Tal restrição ocorre devido, principalmente, à complexidade e às dimensões da fonte. Em casos como o mencionado, é indispensável um estudo prévio da solução mitigadora, o que pode ser feito por meio de simulações computacionais validadas através de modelos em escala reduzida. O presente trabalho tem por objetivo a verificação da viabilidade de utilização de modelos em escala reduzida ao ar livre como ferramenta de validação de simulação computacional de barreiras acústicas. De caráter experimental e cunho exploratório, o trabalho buscou validar modelo de barreira acústica em escala reduzida ao ar livre para teste de propagação sonora em subestação elétrica. A metodologia envolveu a caracterização da fonte sonora em questão, a construção e teste de modelo e a modelagem/simulação computacional da situação reproduzida em escala reduzida com o programa SoundPLAN 6.4®. Os resultados dos testes em escala reduzida foram empregados para validação de simulação computacional de barreira acústica. Concluiu-se que é possível utilizar modelos reduzidos para tal fim, porém, é necessário que se avalie as condições do entorno durante os ensaios. Dentre as características do entorno a serem avaliadas, citam-se as variáveis climáticas no momento da medição, o ruído de fundo do local, a topografia, o tipo de solo e a presença de vegetação e de edificações. Tais informações podem auxiliar na obtenção de resultados fidedignos e, desta forma, garantir o futuro desempenho de soluções mitigadoras de ruído por meio da utilização de modelos em escala reduzida para validação de simulação computacional / Abstract: Noise barriers have been used as solutions to mitigate environmental noise. The study on performance of noise barriers is commonly accomplished through computer simulations with the specific sound propagation software. Tests of reduced scale models made in anechoic chamber are also tools used in this type of evaluation and can assist in validating the developed computer model. The restriction of access to anechoic chambers and the large dimensions of certain sources, such as electrical substations, may not allow tests in these chambers and lead to reduced model tests outdoors. These tests are practically nonexistent in the literature, which gives unique character to the research presented in this work. In the case of electrical substations that may be causing noise disturbance in their surroundings, it is pointed out the impossibility of implementing mitigation solutions to post-validate the solution employed. This restriction is due mainly to the complexity and size of the source. In similar cases, it is necessary a previous study on mitigation solutions, which may be done by way of computer simulations validated through reduced scale models. This work aims to verify the feasibility of using reduced scale outdoor models as a tool for validation of computer simulation of noise barriers. On the basis of experimental approach and exploratory nature, the application to the sound propagation in electrical substations is considered. The methodology involves the characterization of the sound source in question, the construction and testing of reduced scale model and modeling/simulation of the situation reproduced on a reduced scale with the software SoundPLAN 6.4®. The results of tests with scale outdoor model were used to validate computer simulation of acoustic barrier. It was concluded that it is possible to use reduced models for this purpose; however, it is necessary to evaluate the conditions of the environment during the tests. Among the characteristics of the environment to be evaluated, climatic variables at the time of measurement, background noise of the place, topography, soil type and presence of vegetation and buildings are considered. Such information can assist in obtaining reliable results and thus they guarantee the future performance of noise mitigation solutions through the use of reduced scale models for validating computer simulation / Doutorado / Arquitetura e Construção / Doutora em Engenharia Civil
237

Controle ativo de vibrações em vigas e placas usando uma abordagem de intensidade estrutural / Active control oi vibmtion in beams and plates using a structuml intensity approach

Pereira, Allan Kardec Araujo 26 March 1999 (has links)
Orientador: Jose Roberto de França Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T10:44:12Z (GMT). No. of bitstreams: 1 Pereira_AllanKardecAraujo_D.pdf: 9794175 bytes, checksum: 619e00345631f64039182d262ce4f5e0 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste trabalho foi estudar a aplicabilidade de uma metodologia de controle de vibrações em estruturas usando uma abordagem de intensidade estrutural (SI). Tal metodologia (ASIC) foi então aplicada ao estudo de vigas e placas em flexão. Técnicas de estimativa da SI em estruturas foram revistas e foram utilizados acelerômetros e sensores cerâmicos piezelétricos para as medidas de vibração. Para fins de controle, as estruturas foram identificadas usando algoritmos Q-Markov Cover e os modelos obtidos foram utilizados em simulações numéricas. Experimentos também foram implementados. Para o caso do controle da SI em vigas, o ASIC foi comparado com outras metodologias quais sejam, o FXLMS, o FXLMS MIMO e o método de Gibbs-Fuller. O ASIC se mostrou em média ligeiramente mais efetivo que o Gibbs-Fuller para os casos de excitação tonal e bastante mais efetivo para os casos de multi-frequência. Já para o caso de controle de placas, foi utilizada uma configuração com um atuador e oito sensores para a estimativa do divergente da SI. Tal configuração só permitiu atenuações locais para os casos estudados. Modificações na metodologia foram propostas e o controlador se transformou em controlador geral de intensidade, tanto acústica quanto estrutural / Abstract: The main goal of this work was to study the aplicability of a new methodology to control structural vibrations using a structural intensity approach. This methodology was then used to control flexural vibration in beams and plates. Techniques to estimate the structural intensity were revised. Accelerometers and piezelectric sensors were used in order to measure the vibration. The structures were identified using a Q-Markov Cover algorithm and the identified models were used in numerical simulations. Experiments were made using a DSP board. In the case of the beam, the ASIC was compared to the FXLMS, the MIMO FXLMS and the Gibbs-Fuller methods. The ASIC method performed slightly better throughout the investigated frequency range when compared to the Gibbs-Fuller method in the case of tonal excitation. For the case of multiple frequencies, the ASIC performed much better than the Gibbs-Fuller. In the case of the plate, only one actuator and eight sensors were used. With this configuration, the ASIC only controlled the vibrations locally. Some changes in the ASIC were proposed which made it a general intensity controller / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
238

Um estudo do controle ativo de ruidos em dutos usando o algoritmo do minimo erro medio quadratico com referencia filtrada / A study of active noise control in ducts using reference filtered least mean square algorithm

Nunes, Ronaldo Fernandes 11 March 1999 (has links)
Orientador: Jose Maria Campos dos Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T19:56:09Z (GMT). No. of bitstreams: 1 Nunes_RonaldoFernandes_M.pdf: 5604429 bytes, checksum: 3e2d42b8a7421a42a727f76195057b6e (MD5) Previous issue date: 1999 / Resumo: Neste trabalho foi estudado o controle ativo de ruído em dutos usando técnicas de filtragem adaptativa. Foi utilizado o método de controle adaptativo do Mínimo Erro Médio Quadrático (Least Mean Square - LMS) normalizado com sinal de referência filtrado, NFXLMS. Três geometrias de dutos montados em uma bancada experimental para os casos de controle monocanal, multierro e multiexcitação foram verificados. Os sinais de perturbação investigados foram: tonal (seno), aleatório e uma com composição de duas senoidais no caso multiexcitação. Avaliações das impedâncias analíticas e experimentais foram verificadas no estudo de uma configuração do duto para o caso de controle monocanal. Simulações e experimentos foram realizados para diversas geometrias de dutos e diferentes tipos de excitação. Parâmetros do algoritmo, como o número de pesos do filtro adaptativo, faixa de frequência de perturbação, fator de convergência do algoritmo e freqüência de amostragem foram investigados nos casos tratados. Os resultados encontrados nos experimentos realizados para o controlador monocanal e multierro confirmaram as avaliações efetuadas nas simulações. Para o caso multiexcitação, limitações da placa de processamento de sinal não permitiram a obtenção de resultados conclusivos / Abstract: In this work was investigated the active control of noise in ducts using the techniques of adaptive filtering. The normalized, filtered reference Least Mean Square algorithm control method - NXLMS was used. Three shapes of duct system in a supported experimental test rig for the cases of control mono-channel, multi-error, and multi-input were verified. The investigated disturbance signals were: tonal (sine), random, and a composition of two sinusoids for the case of multi-input. Evaluations of analytical and experimental impedances were verified in a configuration study of mono-channel duct contraI case. Simulations and experiments were accomplished for several duct shapes and different types of excitations. AIgorithm parameters, such as the weight number of adaptive filter, the disturbance frequency range, the convergence factor of the algorithm, and the sampling frequency were investigated in the treated cases. The experimental results obtained for the mono-channel and multi-error controller confirm the evaluations obtained in the simulations. For the multi-input case, limitations of the DSP board didn't allow to obtain conclusive results / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
239

Estudo da absorção sonora de arranjos decorativos contendo espécies vegetais / Sound absorption study of decorative arrangements containning vegetable species

Vinadé, Rafael dos Santos 14 July 2015 (has links)
This study aims to present a sustainable alternative to noise attenuation in external or internal environments through the application of vegetated arrangements as sound absorbers. This proposal arises from the need to adapt the conventional sound absorption systems, and from the concern for environmental preservation. There was also concern about the decorative applicability of these systems, so its appearance should be aesthetically interesting. To compose the proposal, plant arrangements, containing the Buriti palm (Trithrinax brasiliensis Mart.), arranged in ornamental flowerpots build in MDF (Medium Density Fiberboard plank) and decorated with another plant, known as Barba-de-pau (Tillandsia usneoides) were analyzed. Measurements were performed to identify the sound absorption coefficient (α) of these arrangements, through experiments in reverberation chamber of the Acoustic Engineering Laboratory in the Federal University of Santa Maria, according to ISO 354/2003 standard using the interrupted noise method. From these tests, it was determined the reverberation time (RT) and subsequently the sound absorption coefficient α. The composition containing the two plants and the ornamental flowerpots presented the average sound absorption coefficient between 0,11 and 0,27 from 100 Hz to 5000 Hz range. Thus, it is recommended to use this alternative for noise attenuation in a given room, or using their application in series, containing combined vegetated arrangements. / Este estudo busca apresentar uma alternativa sustentável para atenuação de ruído em ambientes externos ou internos, através da aplicação de arranjos vegetados como absorvedores sonoros. Esta proposta surge da necessidade de adaptação dos sistemas convencionais de absorção sonora, bem como a partir da preocupação com a preservação ambiental. Há também a preocupação com a aplicabilidade decorativa destes sistemas, portanto, sua aparência deve ser esteticamente interessante. Para compor a proposta, houve a análise de arranjos de plantas contendo a palmeira Buriti (Trithrinax brasiliensis Mart.), montadas em cachepôs confeccionados em MDF (Painéis de fibra de média densidade) e decorados com outra planta, conhecida como Barba-de-pau (Tillandsia usneoides). Foram realizadas medições para identificar o coeficiente de absorção sonora α destes arranjos, através de ensaios desenvolvidos em câmara reverberante do Laboratório de Engenharia Acústica da Universidade Federal de Santa Maria, segundo a norma ISO 354/2003, empregando a metodologia de ruído interrompido. A composição contendo as duas plantas e o cachepôs em MDF apresentou o coeficiente de absorção sonora médio que variou entre 0,11 e 0,27 no intervalo de 100Hz até 5000Hz. Assim, recomenda-se a utilização desta alternativa para atenuação de ruído em um dado recinto, ou ainda utilizando sua aplicação em série, contendo vários arranjos vegetados combinados.
240

Measurements, Analysis Techniques and Experiments in Sound and Vibration : Applied to Operational MRI Scanners and in Remote Laboratories.

Khan, Imran January 2017 (has links)
High quality noise and vibration measurements outside of a laboratory environment on real life structures and applications are not trivial. True boundary and operating conditions enforce unique challenges on the measurements. Measurements in hazardous situations such as high magnetic fields, and high temperature environments, etc., where ordinary measurement equipment and methods may not be employed, require further precautions. Post measurements objectives such as analysis, design and strategic decisions, e.g., control, rely heavily on the quality and integrity of the measurements (data). The quality of the experimental data is highly correlated with the on-field expertise. Practical or hands-on experience with measurements can be imparted to prospective students, researchers and technicians in the form of laboratory experiments involving real equipment and practical applications. However, achieving expertise in the field of sound and vibration measurements in general and their active control in particular is a time consuming and expensive process. Consequently most institutions can only afford a single setup, resulting in the compromise of the quality of expertise. In this thesis, the challenges in the field of sound and vibration measurements in high magnetic field are addressed. The analysis and measurement of vibration transferred from an operational magnetic resonance imaging (MRI) scanner to adjacent floors is taken as an example. Improvised experimental measurement methods and custom-made frequency analysis techniques are proposed in order to address the challenges and study the vibration transfer. The methods may be extended to other operational industrial machinery and hazardous environments. To encourage and develop expertise in the field of acoustic/vibration measurements and active noise control on practical test beds, remotely controlled laboratory setups are introduced. The developed laboratory setup, which is accessed and controlled via the Internet, is the first of its kind in the active noise control and acoustic measurements area. The laboratory setup can be shared and utilized 24/7 globally, thus reducing the associated costs and eliminating time restrictions.

Page generated in 0.0577 seconds