Spelling suggestions: "subject:"ocular biomechanical""
1 |
Biomechanics of the Human Eye and Intraocular Pressure MeasurementsLjubimova, Darja January 2009 (has links)
This thesis addresses the reliability of Goldmann-type applanation tonometers (GAT). It deals with the investigation of the relation between predicted intraocular pressure, IOPG and true pressure, IOPT. The problem of the accuracy of GAT readings has acquired special importance over the last two decades as new types of surgical procedures to correct vision disorders are being explored and gain universal acceptance. The overall aim of the present study is to assess the effects of individual variations in the corneal central thickness (CCT), material properties of the involved tissues and paracentral applanation on the accuracy of IOPG. Two finite element models have been constructed: a two-dimensional axisymmetric model of the cornea and a three-dimensional model of the whole corneoscleral envelope. Various material descriptions were adopted for the cornea in 2D, whereas the 3D model accounted for collagen microstructure and represented a hyperelastic ber reinforced material. Nonlinear analyses were carried out using the commercial general-purpose finite element software ABAQUS. An extensive literature survey and consultations with ophthalmologists and clinicians were the platform for establishing relevant modelling procedures. The results reveal a clear association between all considered parameters and measured IOPG. The effect of assumed CCT is highly dependent on the corneal material properties. Material model alone has a profound effect on predicted IOPG. Variations in tonometer tip application produce clinically signi cant errors to IOPG measurements. Potential effects of corneal stiffness and paracentral applanation on GAT readings are larger than the impact of CCT. The behaviour of the models is broadly in agreement with published observations. The proposed procedures can be a useful tools for suggesting the magnitudes of corrections for corneal biomechanics and possible human errors. The present modelling exercise has an ability to reproduce the behaviour of human cornea and trace it under IOP and GAT, providing potentially useful information on the distribution of stresses and strains. Some recommendations can be drawn in pursuit of the clinical imperatives of ophthalmologists. / QC 20100729
|
2 |
The Impact of Tonometer Measurement Error on Ocular Pulse Amplitude and the Estimation of Pulsatile Ocular Blood VolumeSomogye, Ryan January 2021 (has links)
No description available.
|
3 |
A hybridizable discontinuous Galerkin method for nonlinear porous media viscoelasticity with applications in ophthalmologyPrada, Daniele 12 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The interplay between biomechanics and blood perfusion in the optic nerve head (ONH) has a critical role in ocular pathologies, especially glaucomatous optic neuropathy. Elucidating the complex interactions of ONH perfusion and tissue structure in health and disease using current imaging methodologies is difficult, and mathematical modeling provides an approach to address these limitations. The biophysical phenomena governing the ONH physiology occur at different scales in time and space and porous media theory provides an ideal framework to model them. We critically review fundamentals of porous media theory, paying particular attention to the assumptions leading to a continuum biphasic model for the phenomenological description of fluid flow through biological tissues exhibiting viscoelastic behavior. The resulting system of equations is solved via a numerical method based on a novel hybridizable discontinuous Galerkin finite element discretization that allows accurate approximations of stresses and discharge velocities, in addition to solid displacement and fluid pressure. The model is used to theoretically investigate the influence of tissue viscoelasticity on the blood perfusion of the lamina cribrosa in the ONH. Our results suggest that changes in viscoelastic properties of the lamina may compromise tissue perfusion in response to sudden variations of intraocular pressure, possibly leading to optic disc hemorrhages.
|
4 |
Tools for Improved Refractive Surgery: Computational and Experimental StudySeven, Ibrahim January 2014 (has links)
No description available.
|
5 |
Ocular biomechanics in glaucoma and space-related neuro-ocular syndrome : assessing ocular rigidity and pulsatile optic nerve deformation with video-optical coherence tomography.Masís-Solano, Marissé 04 1900 (has links)
La compréhension des propriétés biomécaniques de la tête du nerf optique (TNO) est cruciale pour la gestion de conditions telles que le glaucome et le Syndrome Neuro-Oculaire Lié à l'Espace (SNOE). Cette thèse propose d’utiliser l'imagerie par tomographie de cohérence optique vidéo à haute fréquence (V-OCT) traitée avec des algorithmes de traitement d'image existants pour évaluer quantitativement la déformation pulsatile de la TNO due aux cycles cardiaques. Cette méthode est utilisée afin d’investiguer deux phénomènes: la réponse biomécanique de la TNO dans les conditions terrestres; et la réponse du TNO dans l'environnement de microgravité de l'espace.
Le premier segment de cette thèse présente une nouvelle méthode non-invasive pour mesurer le déplacement pulsatile de la TNO via l'OCT vidéo (V-OCT), offrant des progrès significatifs dans la quantification des propriétés biomécaniques de l'œil in vivo. Une validation approfondie de cette technique, à la fois numérique et expérimentale, a confirmé la sensibilité de l'algorithme aux déformations induites, sa robustesse face à divers niveaux de bruit, et sa répétabilité. Deux groupes d’individus, sains et myopes, ont été évalués sous différentes conditions de contrainte physiologique. La déformation pulsatile des tissus de la TNO a été capturée quantitativement et représentée sous forme de cartes de déformation, montrant la sensibilité de la méthodologie aux déformations induites et la robustesse aux interférences de bruit élevé. Pour les sujets dont les yeux ont une longueur axiale de moins de 25mm, des différences notables de déformation pulsatile médiane ont émergé entre les positions primaires et en abduction de l'œil, avec une reproductibilité confirmée via des coefficients de corrélation intra-classe élevés.
Ayant validé la méthode, elle a donc a été appliquée à une cohorte de glaucomateux pour examiner l'impact de la réduction de la pression intraoculaire (PIO) sur le déplacement pulsatile de la TNO. Chez les patients atteints de glaucome primaire à angle ouvert (GPAO), en particulier ceux sans myopie axiale, les interventions abaissant la PIO ont conduit à une réduction significative de la pulsation de la TNO. Cependant, les patients glaucomateux myopes n'ont affiché aucun changement substantiel, suggérant une relation nuancée entre la modulation de la PIO et la biomécanique de la TNO. Une étude de cohorte n’a révélé aucune différence marquée dans la pulsation de la TNO à travers divers degrés de gravité du glaucome. Pourtant, la déformation pulsatile a été corrélée à l'épaisseur de la couche de fibres nerveuses rétiniennes et à des mesures hémodynamiques spécifiques, soulignant les interconnexions complexes entre la biomécanique et l'hémodynamique oculaires.
La dernière partie de cette thèse aborde les modifications de la rigidité oculaire chez les astronautes avant et après des vols spatiaux prolongés. En analysant les données de 26 yeux de 13 astronautes, la recherche a démontré des réductions significatives de la rigidité oculaire, de la pression intraoculaire et de l'amplitude du pouls oculaire après la mission. Ces découvertes explorent des effets précédemment inconnus de la microgravité sur les propriétés mécaniques de l'œil, améliorant notre compréhension du SNOE.
Cette étude, tout en approfondissant notre compréhension des complexités biomécaniques et hémodynamiques de la TNO, démontre le potentiel du V-OCT comme outil pour le diagnostic et le suivi des conditions du nerf optique. Les techniques et les perspectives acquises ici posent également les bases pour de futures explorations prometteuses à la fois pour les patients atteints de glaucome et pour les astronautes. / The eye is a semi-rigid sphere with complex biomechanical properties. Chronic disease or stress like space flight can interfere with these properties, leading to vision loss. Noninvasive measurements of the biomechanical properties of the optic nerve head (ONH) could provide better tracking and management of conditions such as glaucoma and Space-Related Neuro-Ocular Syndrome (SANS). This thesis proposes to use high-frequency optical coherence tomography video imaging (V-OCT) with existing image processing algorithms to quantitatively evaluate the pulsatile displacement of the ONH due to cardiac cycles. This methodology is applied across two streams of research: examining the ocular biomechanical response of the ONH under terrestrial conditions; and the ONH deformation in the microgravity environment of space.
The first section of this thesis introduces a non-invasive method to measure ONH pulsatile displacement via video-based OCT (V-OCT), quantifying biomechanical eye properties in vivo. A thorough validation of this technique, both numerically and experimentally, confirmed the algorithm’s sensitivity to induced deformation, robustness against various noise levels, and repeatability. Two groups, healthy and myopic individuals, underwent assessment under different physiological strain conditions. Pulsatile ONH tissue deformation was quantitatively captured and represented as deformation maps. For those subjects with eyes with an axial length of less than 25mm, notable median pulsatile displacement differences were found between primary and abducted eye positions. Reproducibility was confirmed via high intraclass correlation coefficients.
Building on this foundation, the method was applied to a cohort of glaucoma patients to examine the impact of IOP reduction on ONH pulsatile displacement. In primary open-angle glaucoma (POAG) patients, particularly those without axial myopia, IOP-lowering interventions significantly reduced ONH pulsation. However, myopic glaucoma patients displayed no substantial changes, suggesting that myopic status moderates the relationship between IOP modulation and ONH biomechanics. This pilot study was expanded to a larger cross-sectional cohort study (N=176), revealing a decrease in ONH pulsatile displacement in people with early and moderate glaucoma compared to controls. . In addition, pulsatile displacement correlated with retinal nerve fiber layer thickness and specific hemodynamic measures, showing that ocular biomechanics and hemodynamics are closely linked.
The last section of the thesis investigates ocular rigidity alterations in astronauts before and after extended space flights. Analyzing data from 26 eyes of 13 astronauts, significant reductions in ocular rigidity were observed; similarly, intraocular pressure and ocular pulse amplitude were reduced post-mission. These findings reveal previously undocumented microgravity effects on the eye's mechanical properties, improving our comprehension of SANS.
This thesis demonstrates the potential of V-OCT as a tool for the diagnosis and assessment of the progression of optic nerve conditions. By gaining a deeper understanding of the biomechanical and hemodynamic intricacies of the ONH, we lay the groundwork for future explorations that hold promise for both glaucoma patients and astronauts.
|
6 |
Ocular rigidity : a previously unexplored risk factor in the pathophysiology of open-angle glaucoma : assessment using a novel OCT-based measurement methodSayah, Diane Noël 02 1900 (has links)
Le glaucome est la première cause de cécité irréversible dans le monde. Bien que sa pathogenèse
demeure encore nébuleuse, les propriétés biomécaniques de l’oeil sembleraient jouer un rôle
important dans le développement et la progression de cette maladie. Il est stipulé que la rigidité
oculaire (RO) est altérée au travers les divers stades de la maladie et qu’elle serait le facteur le
plus influent sur la réponse du nerf optique aux variations de la pression intraoculaire (PIO) au
sein du glaucome. Pour permettre l’investigation du rôle de la RO dans le glaucome primaire à
angle ouvert (GPAO), la capacité de quantifier la RO in vivo par l’entremise d’une méthode fiable
et non-invasive est essentielle. Une telle méthode n’est disponible que depuis 2015. Basée sur
l'équation de Friedenwald, cette approche combine l'imagerie par tomographie par cohérence
optique (TCO) et la segmentation choroïdienne automatisée afin de mesurer le changement de
volume choroïdien pulsatile (ΔV), ainsi que la tonométrie dynamique de contour Pascal pour
mesurer le changement de pression pulsatile correspondant.
L’objectif de cette thèse est d’évaluer la validité de cette méthode, et d’en faire usage afin
d’investiguer le rôle de la RO dans les maladies oculaires, particulièrement le GPAO. Plus
spécifiquement, cette thèse vise à : 1) améliorer la méthode proposée et évaluer sa validité ainsi
que sa répétabilité, 2) investiguer l’association entre la RO et le dommage neuro-rétinien chez les
patients glaucomateux, et ceux atteints d’un syndrome de vasospasticité, 3) évaluer l’association
entre la RO et les paramètres biomécaniques de la cornée, 4) évaluer l’association entre la RO et
les pics de PIO survenant suite aux thérapies par injections intravitréennes (IIV), afin de les prédire
et de les prévenir chez les patients à haut risque, et 5) confirmer que la RO est réduite dans les
yeux myopes.
D’abord, nous avons amélioré le modèle mathématique de l’oeil utilisé pour dériver ΔV en le
rendant plus précis anatomiquement et en tenant compte de la choroïde périphérique. Nous
avons démontré la validité et la bonne répétabilité de cette méthodologie. Puis, nous avons
effectué la mesure des coefficients de RO sur un large éventail de sujets sains et glaucomateux
en utilisant notre méthode non-invasive, et avons démontré, pour la première fois, qu'une RO basse est corrélée aux dommages glaucomateux. Les corrélations observées étaient comparables
à celles obtenues avec des facteurs de risque reconnus tels que la PIO maximale. Une forte
corrélation entre la RO et les dommages neuro-rétiniens a été observée chez les patients
vasospastiques, mais pas chez ceux atteints d'une maladie vasculaire ischémique. Cela pourrait
potentiellement indiquer une plus grande susceptibilité au glaucome due à la biomécanique
oculaire chez les patients vasospastiques. Bien que les paramètres biomécaniques cornéens aient
été largement adoptés dans la pratique clinique en tant que substitut pour la RO, propriété
biomécanique globale de l'oeil, nous avons démontré une association limitée entre la RO et ces
paramètres, offrant une nouvelle perspective sur la relation entre les propriétés biomécaniques
cornéennes et globales de l’oeil. Seule une faible corrélation entre le facteur de résistance
cornéenne et la RO demeure après ajustement pour les facteurs de confusion dans le groupe des
patients glaucomateux. Ensuite, nous avons présenté un modèle pour prédire l'amplitude des pics
de PIO après IIV à partir de la mesure non-invasive de la RO. Ceci est particulièrement utile pour
les patients à haut risque atteints de maladies rétiniennes exsudatives et de glaucome qui
nécessiteraient des IIV thérapeutiques, et pourrait permettre aux cliniciens d'ajuster ou de
personnaliser le traitement pour éviter toute perte de vision additionnelle. Enfin, nous avons
étudié les différences de RO entre les yeux myopes et les non-myopes en utilisant cette
technique, et avons démontré une RO inférieure dans la myopie axiale, facteur de risque du
GPAO. Dans l'ensemble, ces résultats contribuent à l’avancement des connaissances sur la
physiopathologie du GPAO. Le développement de notre méthode permettra non seulement de
mieux explorer le rôle de la RO dans les maladies oculaires, mais contribuera également à élucider
les mécanismes et développer de nouveaux traitements ciblant la RO pour contrer la déficience
visuelle liée à ces maladies. / Glaucoma is the leading cause of irreversible blindness worldwide. While its pathogenesis is yet
to be fully understood, the biomechanical properties of the eye are thought to be involved in the
development and progression of this disease. Ocular rigidity (OR) is thought to be altered through
disease processes and has been suggested to be the most influential factor on the optic nerve
head’s response to variations in intraocular pressure (IOP) in glaucoma. To further investigate the
role of OR in open-angle glaucoma (OAG) and other ocular diseases such as myopia, the ability to
quantify OR in living human eyes using a reliable and non-invasive method is essential. Such a
method has only become available in 2015. Based on the Friedenwald equation, the method uses
time-lapse optical coherence tomography (OCT) imaging and automated choroidal segmentation
to measure the pulsatile choroidal volume change (ΔV), and Pascal dynamic contour tonometry
to measure the corresponding pulsatile pressure change.
The purpose of this thesis work was to assess the validity of the methodology, then use it to
investigate the role of OR in ocular diseases, particularly in OAG. More specifically, the objectives
were: 1) To improve the extrapolation of ΔV and evaluate the method’s validity and repeatability,
2) To investigate the association between OR and neuro-retinal damage in glaucomatous
patients, as well as those with concomitant vasospasticity, 3) To evaluate the association between
OR and corneal biomechanical parameters, 4) To assess the association between OR and IOP
spikes following therapeutic intravitreal injections (IVIs), to predict and prevent them in high-risk
patients, and 5) To confirm that OR is lower in myopia.
First, we improved the mathematical model of the eye used to derive ΔV by rendering it more
anatomically accurate and accounting for the peripheral choroid. We also confirmed the validity
and good repeatability of the method. We carried out the measurement of OR coefficients on a
wide range of healthy and glaucomatous subjects using this non-invasive method, and were able
to show, for the first time, that lower OR is correlated with more glaucomatous damage. The
correlations observed were comparable to those obtained with recognized risk factors such as
maximum IOP. A strong correlation between OR and neuro-retinal damage was found in patients with concurrent vasospastic syndrome, but not in those with ischemic vascular disease. This could
perhaps indicate a greater susceptibility to glaucoma due to ocular biomechanics in vasospastic
patients. While corneal biomechanical parameters have been widely adopted in clinical practice
as surrogate measurements for the eye’s overall biomechanical properties represented by OR,
we have shown a limited association between these parameters, bringing new insight unto the
relationship between corneal and global biomechanical properties. Only a weak correlation
between the corneal resistance factor and OR remained in glaucomatous eyes after adjusting for
confounding factors. In addition, we presented a model to predict the magnitude of IOP spikes
following IVIs from the non-invasive measurement of OR. This is particularly useful for high-risk
patients with exudative retinal diseases and glaucoma that require therapeutic IVIs, and could
provide the clinician an opportunity to adjust or customize treatment to prevent further vision
loss. Finally, we investigated OR differences between non-myopic and myopic eyes using this
technique, and demonstrated lower OR in axial myopia, a risk factor for OAG. Overall, these
findings provide new insights unto the pathophysiology of glaucomatous optic neuropathy. The
development of our method will permit further investigation of the role of OR in ocular diseases,
contributing to elucidate mechanisms and provide novel management options to counter vision
impairment caused by these diseases.
|
Page generated in 0.0824 seconds