• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 134
  • 29
  • 19
  • 15
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 435
  • 110
  • 74
  • 52
  • 49
  • 43
  • 38
  • 38
  • 36
  • 33
  • 33
  • 30
  • 30
  • 29
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The development and evaluation of a scanning laser Doppler instrument for imaging skin blood flow

Essex, Timothy John Hudson January 1993 (has links)
No description available.
2

The computer aided design of electron detectors for the scanning electron microscope

Khursheed, A. January 1983 (has links)
No description available.
3

Novel opto-electronic and plastic optical fibre sensors

Ioannides, Nicos January 1998 (has links)
The design and performance of a novel displacement sensor is investigated both theoretically and experimentally. This is an optical, extrinsic and differential sensor based on the inverse square law and is insensitive to source intensity variations. It can, in principle, be implemented using only opto-electronic components or it can incorporate optical fibres to allow for EMI free and remote operation. The sensor is implemented using Plastic Optical Fibres (POF) as these offer considerable advantages over glass fibres or glass fibre bundles. The sensor head consists of three POFs positioned side by side and displaced from each other parallel to the axis of the sensor head by a separation X, (mm). The middle POF is coupled to a red LED and emits light onto a flat target with the two outer fibres receiving the reflected light from the target and guiding it to two silicon PIN photodiodes. Theoretical investigations on the behaviour of the sensor are presented for ranges between 0 mm and 100 mm, and for targets with different reflectivities. Non-linearities in the form of a spike are shown to exist in the very short ranges resulting in a minimum operational range of about 15 nun Beyond this minimum range the sensor response is linear and depends on the reflectivity of the target, the accuracy of calibration between the two detectors, any offset voltage present in any of the detectors, possible errors on the detected signals and the X, separation which in principle can be used to scale the sensor. Experimental results obtained confirm the long and linear operational range of the sensor (between 15 mm and 90 mm for a mirror target and between 20 mm and 100 mm for a matt white paper target). Likely variations in the source light intensity do not affect the performance and accuracy of the sensor. Measurements performed with various X, separations verify the scalability feature of the sensor in that by increasing X, one can achieve longer operational ranges. Temperature variations up to 40 °c do not affect the linearity of response. Effects arising from angular misalignment of the target and! or the ends of the three POFs are also investigated and could be minimised by rotating the emitting POF. Matt white paper is concluded as the preferred type of target since it offers a longer linear operational range with less stringent alignment requirements as opposed to reflective targets. Operation of the sensor under ambient illumination conditions is demonstrated using suitable electronic circuitry with filtering facilities. The result is a linear operational range of 60 mm with 1 % accuracy with a matt white paper target. An automated version of the sensor under software control is also demonstrated for monitoring large amplitude (0.15 mm - 6 mm), single degree vibrations. The maximum determined frequency of the vibrating surface is about 150 Hz and this is only limited by the target displacement which is close to the resolution limits of this version of the sensor (0.15 mm). This novel sensor offers considerable advantages over other sensors reported in the literature. It is shown to offer a very long and linear operational range in excess of 100 mm, with accuracy better than 1% and resolution better than 0.2 % of range, and currently this performance is only limited by the electronic circuitry used. Overall, the proposed sensor offers a superior sensor head arrangement and performance combination and its cost is expected to be very low. Suggestions for improvements and other applications are offered.
4

Identification of process plant signatures using flow measurement signals for sensor validation, condition monitoring, and plant diagnostics

Amadi-Echendu, Joe E. January 1990 (has links)
The need to apply modern signal processing and analysis techniques to enhance the performance of process instrumentation systems has been identified as one of the priority areas for research and development in process instrumentation and process control. This enhancement of performance can be in the form of extracting additional information from flow sensors beyond the customary requirements of the basic process measurement, that is, flow rate. In conjunction with, and within the expert systems approach, an enhanced flowmeter can, for example, be utilised for condition monitoring purposes and, for diagnostic engineering management and optimisation of process plant operations. This thesis demonstrates the new importance of flow measurement signals from the point of view of extracting additional information which include: - (i) the basic process measurement value (ii) a quality or validity index associated with the basic measurement value, (iii) any other information which can be used to characterise the operational status of the plant and associated instrumentation. The signal processing tasks involve spectral analysis and spectrum estimation, system identification and parametric time series modelling techniques. Qualitative signatures which have been identified for different flowmeters operating under a wide variety of conditions in different process flow rigs are described. The utilisation of the results towards enhancing the performance the of the process instrumentation system is emphasised and demonstrated throughout the thesis.
5

Photoemission studies of dispenser cathodes surfaces

Awobode, Ayodeji Morohunfolu January 1989 (has links)
No description available.
6

The development of a combined scanning electron microscope and scanning tunnelling microscope for nanotechnology

Rosolen, Grahame Craig January 1992 (has links)
No description available.
7

Periodic magnet focussing of electron beams in travelling wave tubes

McGregor, A. January 1986 (has links)
No description available.
8

Errors in luminous intensity measurements and photometric performance of linear sources due to the length of the measuring distance

Frost, J. W. January 1985 (has links)
No description available.
9

Investigation of M.B.E. grown GaAs-Si heterostructures for optical monolithic integration

Mehta, Mitul January 1993 (has links)
No description available.
10

Molybdenum nitrosyl tris-(3,5-dimethylpyrazolyl)borato complexes for photochemistry, nonlinear optics and molecular electronics

Navas, John Alvaro January 1994 (has links)
No description available.

Page generated in 0.059 seconds