Spelling suggestions: "subject:"ortodônticos"" "subject:"ortodontico""
11 |
AVALIAÇÃO COMPARATIVA DA HIGIENIZAÇÃO BUCAL DE PACIENTES COM APARELHO ORTODÔNTICO FIXO LINGUAL E LABIAL / Comparative avaliation of bucal hygiene in lingual and labial orthodontic patientsGalvão, Maria Christina de Souza 29 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:04Z (GMT). No. of bitstreams: 1
Maria Christina.pdf: 1062835 bytes, checksum: 6697fefc437edf793c9a12b9ad8bdc34 (MD5)
Previous issue date: 2006-03-29 / The aim of this research was to assess the oral hygiene in adult patients after lingual brackets placement through bleeding on probing and plaque index and to compare with labial orthodontics patient. The group 1 (G1) consisted of 11 lingual orthodontic patients, mean age 22y and 9m. The group 2 (G2) consisted of 19 labial orthodontic patients, mean age 25y 8m. The bleeding on probing and plaque index was checked before bonding (T0), from one to two weeks after total bonding, including wires (T1). After that brushing instructions were given to them. The patients were checked again after 1 month (T2), 2 months (T3), and 3 months (T4), when reinforcement instructions were given. The appliance kind effect was compared between groups and the lingual and labial face changes in the same person were assessed, too. There was a significant worsening in plaque index in T1, except for the lingual orthodontic labial face. Both labial and lingual appliances seemed to cause an increase in gingivitis in adult patients, showed by gingival bleeding. After
instructions G2 showed to return to initial plaque index. However, G1, despite some improvement, couldnt do the same, and was less efficient than G2 in T1 and T4. / O objetivo desse trabalho foi avaliar a higiene oral de pacientes adultos, pela análise dos índices de sangramento gengival e de placa pré e pós-colocação do aparelho ortodôntico fixo lingual e compará-la a um grupo de pacientes com aparelho ortodôntico fixo labial. O grupo 1 (G1), foi constituído de 11 pacientes, com idade média de 22 anos e 9 meses, tratado com braquetes linguais. O grupo 2 (G2)
foi formado por 19 pacientes, com idade média de 26 anos e 8 meses, tratado com braquetes labiais. O sangramento gengival e o índice de placa foram avaliados antes
da colagem (T0); 1 semana/15 dias após a colocação total do aparelho, inclusive com arcos (T1). Após isso, foram dadas instruções de higienização. Os pacientes foram novamente avaliados 1 mês após a colocação (T2); 2 meses (T3) e 3 meses (T4), quando foram dados reforços das instruções conforme necessário. Nas avaliações inter-grupos, foram comparadas as alterações relativas ao tipo de
aparelho empregado e nas avaliações intra-grupos comparou-se a face vestibular e lingual de um mesmo indivíduo. Os resultados mostraram que houve um significante
aumento no índice de placa em T1, exceto na face vestibular dos pacientes com aparelho lingual. Em ambos os grupos, houve um aumento semelhante da gengivite caracterizada pelo aumento do sangramento gengival. Após as instruções de
escovação, os pacientes do G2 foram capazes de retornar aos seus índices de placa anteriores à colocação do aparelho. Os pacientes do G1, apesar de haver melhora,
não conseguiram voltar aos índices de placa iniciais e tiveram uma menor eficácia de higienização comparado a G2 em T1 e T4.
|
12 |
ANÁLISE COMPARATIVA DOS NÍVEIS DE ATRITO EM BRÁQUETES CONVENCIONAIS E AUTOLIGADOS / Friction levels comparative analysis in self-ligated and conventional brackets.Picchioni, Mauro dos Santos 06 March 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:07Z (GMT). No. of bitstreams: 1
Mauro dos Santos Pichioni.pdf: 2125883 bytes, checksum: cef06952dac67f4c03556888123fea6b (MD5)
Previous issue date: 2007-03-06 / The friction between brackets and orthodontic wires is an important issue to be considered concerning to orthodontic treatment efficiency in the sliding mechanics. Because this, always there are a search for ways to reduce the friction levels during this type of mechanics. With the introduction of self-ligated bracketts, it was observed that one of these devices main characteristics would be a reduction levels reduction of friction between brackets and wires, and because this the movement could be more efficient, with the application of low forces when compared the using of brackets with conventional ligation systems. The purpose of this study is compare by means of laboratorial tests, the esthatic friction coefficients of one esthetic self-ligated bracket, one metallic self-ligated bracket and two metallic conventional brackets, with the orthodontic wires of different materials, section and sizes, to determine which brackets presents the lowest coefficients of friction, in situations of different angulations between wires and brackets. The results had demonstrated that self-ligated brackets had presented a static friction significantly lower at situations whitout angulation between the wire and brackets and when using small size wires, with more flexible material, when compared with conventional brackets. The metallic self-ligated bracket presented more friction, similar the conventional brackets, with the use larger diameter wires, without angulation between bracket and wire. The metallic self-ligated bracket presented higher static friction when compared with conventional brackets, with the use larger diameter wires, at situations with angulation betwen bracket and wire. / O atrito existente entre bráquetes e os fios ortodônticos é um fator importante a ser considerado quanto à eficiência do tratamento ortodôntico nas mecânicas de deslize. Em função disto, sempre se procurou maneiras de se diminuir os níveis de atrito durante a aplicação deste tipo de mecânica. Com o surgimento dos bráquetes autoligados, observou-se que uma das características principais destes dispositivos seria uma redução dos níveis de atrito entre os bráquetes e fios, e com isso poderia se obter um movimento de deslizamento eficiente com a aplicação de forças menores, quando comparado com o uso de bráquetes que tenham sistemas de amarração convencionais. O propósito deste trabalho foi comparar, por meio de ensaios laboratoriais, os níveis de atrito estático de um bráquete autoligado estético, de um bráquete autoligado metálico e dois tipos de bráquetes convencionais metálicos, com a utilização de fios ortodônticos de diferentes ligas, secção e diâmetros, para determinar quais bráquetes apresentam os menores coeficientes de atrito, em situações sem angulação, em angulações de primeira ordem e angulações de segunda ordem entre os diferentes fios e bráquetes. Os resultados demonstraram que os bráquetes autoligados apresentaram um atrito estático significativamente mais baixo nas situações onde não existiu angulação entre o fio e o bráquete e quando se utilizou fios de calibres menores e com material mais flexível, quando comparados com os bráquetes convencionais. O bráquete autoligado metálico apresentou maior atrito, semelhante aos bráquetes convencionais, com o uso dos fios de maior calibre, nas situações sem angulação. O bráquete autoligado metálico apresentou maior atrito estático que os bráquetes convencionais, nas situações de angulação, com o uso dos fios de maior calibre
|
13 |
Estudo comparativo da degradação de forças geradas por elásticos ortodônticos sintéticos e molas de níquel-titânioAraujo, Fabiana Ballete de Cara [UNESP] 19 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-05-19Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1
araujo_fbc_dr_sjc.pdf: 312103 bytes, checksum: 3f21d0423598e73724ad1f5cf82e2469 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Analisaram-se separada e comparativamente três marcas comerciais de elásticos ortodônticos sintéticos e de molas de NiTi (MORELLI, ORMCO e GAC), quanto à degradação da força sofrida por estes materiais em função do tempo, quando submetidos a simulação das condições bucais. Os elásticos e molas foram inicialmente termociclados (temperaturas de 15°C e 45°C), em seguida estirados em 20mm, imersos em saliva artificial a 37°C e desativados em 0,5mm semanais. As leituras da quantidade de força gerada pelas amostras foram realizadas nos momentos: inicial, 1, 24, 48 horas, 7, 14, 21 e 28 dias. Observou-se significativa redução na quantidade de força gerada pelos elásticos na primeira hora de ativação, que variou de 49,5% a 53%, enquanto que para as molas a degradação foi signicativamente menor, com valores entre 4,2% e 18,1%. Ao término de 28 dias de testes, as amostras de elásticos sofreram redução média na quantidade de força gerada entre 82,7% e 91,2% (GAC-82,7%, ORMCO-86,0% e MORELLI- 91,2%) já as amostras de molas apresentaram degradação média de força entre 17,5% e 32,2% (MORELLI-17,5%, ORMCO-27,3% e GAC-32,2%). Concluiu-se que, em geral, os elásticos promoveram maior índice inicial de força que as molas, mas após as primeiras 24 horas de ativação a quantidade de força gerada pelos elásticos era menor que a promovida pelas molas, que assim apresentaram níveis médios de força mais constantes que os elásticos ao longo dos testes. / Three commercial marks of synthetic elastics and NiTi coil springs (MORELLI, ORMCO, GAC) were separately and comparably analyzed, according to the force degradation generated by these materials, because of the time, when maintained stretched in artificial salivary, 37°C. The synthetic elastics and NiTi coil springs were thermal- cycled (15°C-45°C) and stretched in 20mm, and this stretch was reduced in 0,5mm weekly. The readings of the amount generated for elastics and coil springs were done in the intervals 0, 1, 24, 48h, 7, 14, 21 and 28 days. Where observed significative reduction on the amount of force generated for the elastics in the first hour of the activation (49,5%- 53%), and 82,7% - 91,2% in 28 days of the tests ( MORELLI - 91,2%, ORMCO - 86,0%, GAC - 82,7%);, while the generated force for NiTi coil springs suffered a reduction of 4,2%- 18,1%, in the first hour of the experimentation and 17,5% - 32,2% in 28 days of the stretch (MORELLI - 17,5%, ORMCO - 27,3%, GAC - 32,2%). We conclude that for most elastics delivered larger initial force that NiTi coil springs, but after 24 hours of activation the NiTi coil springs delivered larger force that the elastics and generated level of the force more constant that elastics.
|
14 |
Avaliação clínica e microbiológica periodontal de crianças e adolescentes sob terapia ortodôntica com aparelhos fixos ou removíveisRêgo, Rodrigo Otávio Citó César [UNESP] 06 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-10-06Bitstream added on 2014-06-13T19:04:26Z : No. of bitstreams: 1
rego_rocc_dr_arafo.pdf: 771295 bytes, checksum: 5b0351282506ff58004e2c6aac89a587 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar os parâmetros clínicos e microbiológicos periodontais de crianças e adolescentes sob terapia ortodôntica com aparelho fixo ou removíveis. Trinta indivíduos (14,5l1,7 anos - Grupo FIX) que utilizavam aparelhos fixos e 18 que utilizavam aparelho extra bucal removível ou placa de Hawley há pelo menos 6 meses (9,6 l 1,5 anos - Grupo REM) foram comparados a dois grupos controle, constituídos por indivíduos da mesma idade (14,2 l 1,7 anos - Grupo C-FIX e 9,3 l 1,9 anos - Grupo C-REM) que não utlizavam esses dispositivos. Foi analisada a presença de placa bacteriana visível (IP), sangramento gengival (IG), profundidade de sondagem (PS) e perda de inserção clínica (PIC). Amostras de placa bacteriana subgengival foram coletadas e analisadas por meio de sondas de oligonucleotídeos para A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, espiroquetas, T. forsythensis e Treponema sp. Diferenças significantes (p<0,05) foram observadas entre os grupos FIX e C-FIX quanto aos parâmetros IP (66,8% e 47,7%), IG (43% e 15,6%), e para as prevalências de todas as bactérias avaliadas, exceto as da familia Neisseriaceae. Entre dentes bandados e seus análogos no grupo controle foram encontradas diferenças significantes para os parâmetros PV (80,3% e 58,8%), SM (64,3% e 20,6%) e PS (2,9 mm e 2,5 mm), respectivamente. Entre os grupos REM e C-REM, essas diferenças também foram observadas para IP (58,7% e 14,3%) e IG (19,8% e 8,8%) e para as prevalências de Aa, C. rectus, E. corrodens, Neisseriaceae e espiroquetas. Entre os dentes retentores de grampo e seus análogos no grupo controle verificou-se diferenças significantes para IP (77,8% e 31,3%). Não foi verificado aumento da PS associado a PIC. Também foi avaliada a... . / The purpose of this study was to compare clinical and microbiological parameters in children and adolescents with and without fixed or removable orthodontic appliances. Thirty subjects (mean age 14.5l1.7 years) treated with fixed appliances and 18 treated with removable appliances for at least 6 months were selected as test groups, FIX and REM, respectively. The control groups were comprised of 30 subjects (mean age 14.2l1.7 years - Group C-FIX) and 18 subjects (mean age 9.3l1.9 years - Group C-REM) that did not receive orthodontic treatment. Clinical evaluations were made for plaque index (PI), gingival index (GI), probing depth (PD) and clinical attachment loss (CAL). Subgingival plaque samples were collected from the patients and analyzed by oligonucleotide probes for the presence of A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, spirochetes, T. forsythensis and Treponema sp. Additionally, two subgingival dental plaque samples from one subject of each test group were further analyzed by cloning and sequencing the amplified 16S rDNA. Significant differences were noted between FIX and C-FIX for PI (66.8% versus 47.7%), GI (43.8% versus 15.6%) and between the banded teeth in the FIX group and the analogous teeth in the C-FIX group for PI (80.3% versus 58.8%), GI (64.3% versus 20.6%) and PD (2.9 mm versus 2.5 mm). Significant differences were noted between FIX and C-FIX for all targeted bacteria but Neisseriaceae. Results: Significant differences were also noted between REM and C-REM for PI (58.7% versus 14.3%) and GI (19.8% versus 8.8%) and between the clasped teeth in the test group and the analogous teeth in the control group for PI (77.8% versus 31.3%). Significant differences were noted between the REM and C-REM for Aa... (Complete abstract, click electronic address below).
|
15 |
Avaliação dos efeitos dento-esqueléticos ocorridos após o tratamento da mordida cruzada posterior, com o uso do aparelho expansor fixo tipo quadrihélicePinheiro, Paulo Márcio de Mendonça [UNESP] 02 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-02Bitstream added on 2014-06-13T19:15:34Z : No. of bitstreams: 1
pinheiro_pmm_me_araca.pdf: 2722486 bytes, checksum: cbf60e9ba3a6a3da79d7dcdd74b803cd (MD5) / Este estudo tem como objetivo avaliar os efeitos dento-esqueléticos decorrentes da correção da mordida cruzada posterior com o aparelho expansor fixo tipo quadrihélice. Foram analisadas telerradiografias em norma frontal póstero-anteriores e modelos de gesso do arco superior de 17 crianças, com média de idade antes do tratamento de 7,5 anos, portadoras de mordida cruzada posterior sem envolvimento esquelético. Os dados foram avaliados em três tempos distintos: Tempo 1 (T1), antes do tratamento; Tempo 2 (T2), após a correção da má oclusão; e Tempo 3 (T3), após três meses de contenção mais 6 meses sem contenção. As medidas transversais nos modelos de gesso mostraram um mesmo padrão, com um aumento entre T1 e T2, uma discreta diminuição entre T2 e T3. A distância inter-segundos molares decíduos apresentou o maior aumento total, seguida pela distância inter-caninos e distância inter-primeiros molares permanentes. As medidas nas telerradiografias mostraram padrões diferentes, e dentre aquelas com diferenças estatisticamente significante, mx’-mx” e ag’-ag” apresentaram aumentos consecutivos entre T1 e T2 e entre T2 e T3 e a medida ms’-ms” mostrou aumento entre T1 e T2 e suave diminuição entre T2 e T3. A medida ii -lsr não apresentou diferença estatisticamente significante. / This study aimed to evaluate the dentoskeletal effects consequent to posterior crossbite correction by using quad-helix fixed espansion appliance. It was analysed telerradiographs in frontal norm and maxillary arch dental cast, taken from 17 children, at 7,5 years of average ages before treatment, with dental and/or functional posterior crossbite malocclusion. Data were analysed among three different periods: Period 1 (T1), before treatment; Period 2 (T2), after malocclusion corrections; and Period 3 (T3), after three months of retention and six months out of retention. Transversal measurements of dental casts showed similar pattern, with an increase T1 and T2, and a discrete decrease between T2 and T3. The distance between the second deciduous molars presented the highest increase, followed by deciduous inter-canine distance and the distance between first permanent molars. The cephalometrics measurements showed different patterns, and among those that presented statistically significant differences, mx’-mx” and ag’-ag” increased at both periods T1-T2 and T2-T3, and ms’-ms” increased at period T1-T2 and decreased slightly at period T2-T3. The variable ii –lsr did not present statistically significant difference.
|
16 |
Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio / Effects of sterilization and clinical use in mechanical properties and surface roughness of nickel titanium wiresPrado, Murilo de Melo 25 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:25:26Z
No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:40:15Z (GMT) No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-21T11:40:15Z (GMT). No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-03-25 / This study evaluated the effects of sterilization and clinical use in the mechanical properties
and surface roughness gauge wires 0.018 "nickel titanium termoset, with the addition of
copper covers: Ormco (Glendora, CA, USA). Twenty-four samples were the evaluation of
mechanical behavior in the load test and deflection, the scanning electron microscopy and
atomic force microscope to check surface roughness. The tests were performed in four
different situations: 1-packaged by the manufacturer (control); 2- packaged by the
manufacturer and autoclaved; 3- after clinical use 60 days and disinfection and 4- and
autoclaved clinical use. The data were submitted to ANOVA and Tukey test. By applying the
deflection test on three points could be observed that the wires in all groups showed
mechanical behavior in the activation / deactivation similar, with no significant statistical
differences. All wires reached the end point of deactivation with forces approximate the
control group (1.398 ± 0.19 N / mm). The AFM and SEM, all thermoset wires showed
irregularities in its surface topography, and there were no major changes in surface pattern
between the groups for the analyzed wire. The qualitative evaluation of surface roughness
showed grooves and craters, influencing the surface of the wires smoothness, while the
quantitative analyzes showed no statistically significant difference between the groups
evaluated. The concluse is that sterilize the wires and use them clinically for 60 days did not
alter the mechanical behavior and the surface roughness of the wires 0.018" NiTi Thermoset
with addition of copper. / Este estudo avaliou os efeitos da esterilização e uso clínico nas propriedades mecânicas e
rugosidade superficial de fios calibre 0,018” de níquel titânio termoativado com adição de
cobre da marca: Ormco (Glendora, CA, USA). Vinte e quatro amostras foram submetidas à
avaliação do comportamento mecânico no teste de carga e deflexão, à microscopia eletrônica
de varredura e microscópio de força atômica para verificação da rugosidade superficial. Os
testes foram realizados em quatro situações distintas: 1- embalado pelo fabricante (controle);
2- embalado pelo fabricante e autoclavado; 3- após uso clínico 60 dias e desinfecção e 4- uso
clínico e autoclavado. Os dados obtidos foram submetidos à análise estatística ANOVA e
teste de Tukey. Pela aplicação do teste de deflexão em três pontos pôde-se observar que os
fios em todos os grupos apresentaram comportamento mecânico na ativação/desativação
semelhantes, não havendo diferenças estatísticas significantes. Todos os fios chegaram ao
ponto final de desativação com forças aproximadas ao grupo controle (1,398 ±0,19 N/mm).
Ao AFM e MEV, todos os fios termoativados apresentaram irregularidades em sua topografia
superficial, não sendo observadas grandes mudanças no padrão superficial entre os grupos
para cada fio analisado. A avaliação qualitativa da rugosidade superficial demonstrou
ranhuras e crateras, influenciando na lisura superficial dos fios, enquanto a avaliação
quantitativa demonstrou não haver diferença estatisticamente significante entre os grupos
avaliados. Concluiu-se que esterilizar os fios e utilizá-los clinicamente por 60 dias não alterou
o comportamento mecânico e nem a rugosidade superficial dos fios 0,018” NiTi
termoativados com adição de cobre.
|
17 |
Avaliação de escova ultrassônica em pacientes sob terapia ortodôntica. Estudo in vitro, clínico e microbiológicoCosta, Mauricio Ribeiro [UNESP] 06 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-07-06Bitstream added on 2014-06-13T18:45:14Z : No. of bitstreams: 1
costa_mr_dr_arafo.pdf: 1446612 bytes, checksum: 025bbf3e00577588cbd095875d456697 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar o efeito de uma escova ultrassônica, comparada a uma elétrica e a uma manual, sobre os parâmetros clínicos periodontais e microbiológicos de adolescentes sob terapia ortodôntica com aparelhos fixos. Paralelamente, foi avaliada a diminuição da força adesiva de braquetes ortodônticos, fixados a dentes humanos extraídos, após o uso de uma escova dentária ultrassônica comparada a uma escova elétrica. Material e Método: Para o experimento in vivo, 21 indivíduos (15,2l1,7) que utilizavam aparelhos fixos há mais de um ano foram divididos em três grupos de acordo com a seqüência de uso das escovas (crossover). Os pacientes usaram cada escova por um período de 30 dias, com intervalos de 15 dias entre as mesmas (washout). Amostras de saliva e placa bacteriana foram coletadas para realização de cultura microbiológica de Streptococcus grupo mutans e técnica de Checkerboard DNA-DNA Hybridization, respectivamente. No experimento in vitro, braquetes ortodônticos foram colados a superfície mais plana de quarenta e cinco dentes humanos extraídos. Posteriormente, os corpos de prova foram divididos em grupos de acordo com a escova a ser utilizada. Após o procedimento de escovação, a resistência adesiva foi avaliada em uma maquina de ensaios mecânicos. Resultado: Uma diferença significante no índice de placa (p<0,05) foi observada após o uso de escova ultrassônica nas superfícies vestibulares (10,32% pré e 3,96% pós-escovação). Da mesma forma, após o uso das escovas ultrassônicas e elétricas, as contagens de Streptococcus grupo mutans diminuíram significativamente (técnica de cultura microbiana - p<0,05). A técnica Checkerboard DNA-DNA hybridization apontou uma redução nos níveis de T. forsythia após o uso da escova elétrica e das espécies S. noxia, S. sanguinis... / This study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of bacteria in relation to an electric and a manual toothbrush. In addition, it was evaluated the effect of brushing with both an ultrasonic and electric toothbrush on the bond strength of orthodontic brackets bonded to extracted human teeth. Material and method: Twenty-one patients (mean 15.2l1.7 years) with orthodontic appliances were randomly divided into three groups according to the sequence of brush usage (crossover study). The subjects used each assigned brush for a period of 30 days, followed by an interval of 15 days (washout) during which they returned to their regular toothbrushes and dental floss used in accordance with the monthly instructions of the orthodontist given prior to the study. During each visit, participants received a periodontal evaluation and samples of saliva and subgingival plaque were collected for microbiological tests (Streptococcus mutans culture and DNA-DNA Checkerboard Hybridization). For in vitro evaluation, individual orthodontic brackets were bonded to the smoothest surface of forty-five teeth. The test specimens were randomly distributed into three groups according to the toothbrush to be used. After completing the brushing stage, the test specimens were taken to the mechanical assay machine for a shearing test. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (10.32% against 3.96%). The counts of S. mutans decreased in the electric and ultrasonic groups (culture test - p<0.05). The DNA-DNA Checkerboard hybridization technique showed that the counts of T. forsythia decreased significantly after a month of electric brush usage. Furthermore, in the manual group, S. noxia, S. sanguinis and P. melaninogenica counts also decreased... (Complete abstract, click electronic access below)
|
Page generated in 0.0631 seconds