• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos parâmetros operacionais de uma célula a combustível de glicerol direto utilizando uma membrana de polibencimidazol impregnada com ácido fosfórico (PBI/H3PO4) ou 1-hexil-3-metilimidazol trifluorometanosulfo / Study of the operating parameters of a direct glycerol fuel cell using a polibenzimidazole membrane impregnated with phosphoric acid (PBI/H3PO4) or 1-hexyl-3-methylimidaolium trifluoromethanesulfonate (PBI/HMI-Tf)

Barrientos, Wilner Valenzuela 16 July 2015 (has links)
Com o aumento da população mundial, o desenvolvimento de novas fontes e conversores de energia tornou-se uma necessidade. As células a combustível mostram-se como uma alternativa viável devido principalmente a duas razões, sua alta eficiência e a utilização de combustíveis renováveis. No presente trabalho se estuda a influência da temperatura de operação e o conteúdo de álcali no combustível sobre a densidade de potencia para uma célula a combustível de glicerol direto. Como combustível foi utilizado uma solução de glicerol:KOH (1M:xM, x=0, 1, 3, 5), como membranas foram utilizados filmes de polibencimidazol impregnado com ácido fosfórico (PBI/H3PO4, relação molar 1:11) ou 1-hexil-3-metilimidazol trifluorometanosulfonato (PBI/HMI-Tf relação molar 1:1.5), e finalmente, nano partículas de Pt suportadas em carbono (60% w/w) como catalizador no ânodo e no cátodo. Em geral, o incremento da temperatura e conteúdo de álcali no combustível mostra um efeito favorável na densidade de potencia do sistema. Numa célula a combustível unitária de glicerol direto utilizando membranas de PBI/ H3PO4 e PBI/HMI-Tf foram obtidas densidades de potencia de 0.54mW.cm-2 a 175°C e 0.599mW.cm-2 a 130°C, respectivamente, para uma solução de glicerol de (1M); enquanto que, para uma solução com um conteúdo maior de álcali, glicerol:KOH (1M:5M), foram obtidas densidades de potencia maiores, 44.1mW.cm-2 a 175°C e 29mW.cm-2 a 130°C, respectivamente. O efeito combinado do incremento da temperatura e concentração de álcali no combustível mostra um efeito maior em relação ao efeito só da temperatura. / With the increasing world population, the development of new energy sources or energy converters has become a necessity. Fuel cells show up as a viable alternative due mainly to two reasons, their high efficiency and the use of renewable fuels. In the present work we study the influence of operating temperature and alkali content in the fuel on the power density for a direct glycerol fuel cell. A glycerol:KOH (1M: xM, x = 0, 1, 3, 5) solution was used as fuels, as membranes were used polibencimidazol films impregnated with phosphoric acid (PBI/H3PO4, molar ratio of 1:11) or 1-hexyl-3-methylimidazolium trifluoromethanesulfonate (PBI/HMI-Tf), and finally, Pt nanoparticles supported on carbon (60% w / w) as catalyst in the anode and cathode. In general, increasing the temperature and alkali content in the fuel shows a favorable effect in the system power density. In a direct glycerol fuel cell using PBI/H3PO4 and PBI /HMI-Tf membranes were obtained power density of 0.54mW.cm-2 at 175°C and 0.599mW.cm-2 at 130°C, respectively, for a 1M glycerol solution; while for a glycerol solution with a higher content of alkali, glycerol:KOH (1M: 5M), were obtained higher power densities, 44.1mW.cm-2 at 175 ° C and 29mW.cm-2 at 130 ° C, respectively. The combined effect of increased temperature and alkali concentration in the fuel shows a greater effect compared to the effect of temperature only.
2

Estudo dos parâmetros operacionais de uma célula a combustível de glicerol direto utilizando uma membrana de polibencimidazol impregnada com ácido fosfórico (PBI/H3PO4) ou 1-hexil-3-metilimidazol trifluorometanosulfo / Study of the operating parameters of a direct glycerol fuel cell using a polibenzimidazole membrane impregnated with phosphoric acid (PBI/H3PO4) or 1-hexyl-3-methylimidaolium trifluoromethanesulfonate (PBI/HMI-Tf)

Wilner Valenzuela Barrientos 16 July 2015 (has links)
Com o aumento da população mundial, o desenvolvimento de novas fontes e conversores de energia tornou-se uma necessidade. As células a combustível mostram-se como uma alternativa viável devido principalmente a duas razões, sua alta eficiência e a utilização de combustíveis renováveis. No presente trabalho se estuda a influência da temperatura de operação e o conteúdo de álcali no combustível sobre a densidade de potencia para uma célula a combustível de glicerol direto. Como combustível foi utilizado uma solução de glicerol:KOH (1M:xM, x=0, 1, 3, 5), como membranas foram utilizados filmes de polibencimidazol impregnado com ácido fosfórico (PBI/H3PO4, relação molar 1:11) ou 1-hexil-3-metilimidazol trifluorometanosulfonato (PBI/HMI-Tf relação molar 1:1.5), e finalmente, nano partículas de Pt suportadas em carbono (60% w/w) como catalizador no ânodo e no cátodo. Em geral, o incremento da temperatura e conteúdo de álcali no combustível mostra um efeito favorável na densidade de potencia do sistema. Numa célula a combustível unitária de glicerol direto utilizando membranas de PBI/ H3PO4 e PBI/HMI-Tf foram obtidas densidades de potencia de 0.54mW.cm-2 a 175°C e 0.599mW.cm-2 a 130°C, respectivamente, para uma solução de glicerol de (1M); enquanto que, para uma solução com um conteúdo maior de álcali, glicerol:KOH (1M:5M), foram obtidas densidades de potencia maiores, 44.1mW.cm-2 a 175°C e 29mW.cm-2 a 130°C, respectivamente. O efeito combinado do incremento da temperatura e concentração de álcali no combustível mostra um efeito maior em relação ao efeito só da temperatura. / With the increasing world population, the development of new energy sources or energy converters has become a necessity. Fuel cells show up as a viable alternative due mainly to two reasons, their high efficiency and the use of renewable fuels. In the present work we study the influence of operating temperature and alkali content in the fuel on the power density for a direct glycerol fuel cell. A glycerol:KOH (1M: xM, x = 0, 1, 3, 5) solution was used as fuels, as membranes were used polibencimidazol films impregnated with phosphoric acid (PBI/H3PO4, molar ratio of 1:11) or 1-hexyl-3-methylimidazolium trifluoromethanesulfonate (PBI/HMI-Tf), and finally, Pt nanoparticles supported on carbon (60% w / w) as catalyst in the anode and cathode. In general, increasing the temperature and alkali content in the fuel shows a favorable effect in the system power density. In a direct glycerol fuel cell using PBI/H3PO4 and PBI /HMI-Tf membranes were obtained power density of 0.54mW.cm-2 at 175°C and 0.599mW.cm-2 at 130°C, respectively, for a 1M glycerol solution; while for a glycerol solution with a higher content of alkali, glycerol:KOH (1M: 5M), were obtained higher power densities, 44.1mW.cm-2 at 175 ° C and 29mW.cm-2 at 130 ° C, respectively. The combined effect of increased temperature and alkali concentration in the fuel shows a greater effect compared to the effect of temperature only.

Page generated in 0.071 seconds