Spelling suggestions: "subject:"preenchidas."" "subject:"preenchido.""
1 |
Estudo do efeito do não preenchimento das juntas verticais e eficiência do graute na resistência da alvenaria estrutural de blocos cerâmicos / Study of the effect of unfilled vertical joints and efficiency of grout in the strength of structural masonry of clay bricksMiranda, Larissa de Almeida 31 October 2012 (has links)
No contexto do crescimento do processo construtivo em alvenaria estrutural, destaca-se o uso do bloco cerâmico consolidado com a criação de sua norma específica de projeto, execução e controle de obras, a NBR 15812, partes 1 e 2 (ABNT, 2010). Desde a difusão da alvenaria estrutural, mudanças nas técnicas construtivas vêm ocorrendo, como por exemplo, o não preenchimento das juntas verticais de assentamento dos blocos. Outra prática que tem sido utilizada é o grauteamento da alvenaria. No entanto, ainda não está estabelecido se o não preenchimento da junta vertical compromete o desempenho da alvenaria ou qual a resistência necessária ao graute para aumentar a resistência da alvenaria. Diante disto, o trabalho objetiva contribuir com o estudo do não preenchimento das juntas verticais avaliando o seu efeito na resistência à compressão e ao cisalhamento de pequenas paredes e também pesquisar a influência do graute em prismas e pequenas paredes submetidos à compressão. Com as análises dos resultados pode-se concluir que o não preenchimento das juntas verticais não exerceu influência nos valores de resistência à compressão e também nos módulos de elasticidade longitudinal das pequenas paredes ensaiadas. No entanto, influenciou significativamente os resultados do ensaio de compressão diagonal para avaliar a resistência ao cisalhamento, apesar do módulo de deformação transversal ter sido considerado equivalente. Os resultados do estudo preliminar em prismas mostraram que a média da resistência à compressão em relação à área bruta do prisma grauteado, utilizando o Graute A e o Graute C, foi equivalente à média do prisma oco. Assim, foi escolhido o Graute A para a confecção de pequenas paredes e prismas. Pode-se concluir com os resultados das pequenas paredes grauteadas que houve um aumento significativo da resistência à compressão em relação à área bruta, mas em relação à área líquida, os valores encontrados foram equivalentes às pequenas paredes ocas. Portanto o aumento na resistência à compressão na pequena parede foi proporcional ao ganho de área dado pelo grauteamento de seus vazios, diferentemente do comportamento observado nos prismas. / In the context of growth of structural masonry construction process, it highlight the use of the ceramic block consolidated with the creation of its specific standard of design, execution and control, the NBR 15812, Parts 1 and 2 (ABNT, 2010). Since the propagation of structural masonry, changes have occurred in the construction techniques, such as don\'t fill the vertical joints of the masonry wall. Another technique that has been used is the grouted masonry. However, it is not yet established if the unfilled vertical joints compromise the performance of masonry or which strength is necessary to the grout to increase the strength of the masonry. Therewith, the paper aims to contribute to the study of unfilled vertical joints by analyzing its effect on compressive strength and shear strength of small walls and also investigate the influence of grout in prisms and small walls under compression. With the analysis of the results we can conclude that do not fill the vertical joints had no influence on the values of compressive strength and elastic modulus of the small walls tested. However, it significantly affects the results of the diagonal compression test to evaluate shear strength, despite the shear elastic modulus being considered equivalent. The results of the preliminary study in prisms showed that the average of the compressive strength in relation to the gross area of the grouted prism using the Grout A and the Grout C were equivalent to the average of hollow prism. Thus, small walls and prisms with the Grout A were made. It can be concluded with the results of grouted small walls that there was a significant increase in compressive strength with respect to the gross area, but in relation to the net area, were similar to the hollow small wall. Therefore the increase in the compressive strength in a small wall is proportional to the gain of the area given by the grout, unlike the behavior observed in the prisms.
|
2 |
Estudo do efeito do não preenchimento das juntas verticais e eficiência do graute na resistência da alvenaria estrutural de blocos cerâmicos / Study of the effect of unfilled vertical joints and efficiency of grout in the strength of structural masonry of clay bricksLarissa de Almeida Miranda 31 October 2012 (has links)
No contexto do crescimento do processo construtivo em alvenaria estrutural, destaca-se o uso do bloco cerâmico consolidado com a criação de sua norma específica de projeto, execução e controle de obras, a NBR 15812, partes 1 e 2 (ABNT, 2010). Desde a difusão da alvenaria estrutural, mudanças nas técnicas construtivas vêm ocorrendo, como por exemplo, o não preenchimento das juntas verticais de assentamento dos blocos. Outra prática que tem sido utilizada é o grauteamento da alvenaria. No entanto, ainda não está estabelecido se o não preenchimento da junta vertical compromete o desempenho da alvenaria ou qual a resistência necessária ao graute para aumentar a resistência da alvenaria. Diante disto, o trabalho objetiva contribuir com o estudo do não preenchimento das juntas verticais avaliando o seu efeito na resistência à compressão e ao cisalhamento de pequenas paredes e também pesquisar a influência do graute em prismas e pequenas paredes submetidos à compressão. Com as análises dos resultados pode-se concluir que o não preenchimento das juntas verticais não exerceu influência nos valores de resistência à compressão e também nos módulos de elasticidade longitudinal das pequenas paredes ensaiadas. No entanto, influenciou significativamente os resultados do ensaio de compressão diagonal para avaliar a resistência ao cisalhamento, apesar do módulo de deformação transversal ter sido considerado equivalente. Os resultados do estudo preliminar em prismas mostraram que a média da resistência à compressão em relação à área bruta do prisma grauteado, utilizando o Graute A e o Graute C, foi equivalente à média do prisma oco. Assim, foi escolhido o Graute A para a confecção de pequenas paredes e prismas. Pode-se concluir com os resultados das pequenas paredes grauteadas que houve um aumento significativo da resistência à compressão em relação à área bruta, mas em relação à área líquida, os valores encontrados foram equivalentes às pequenas paredes ocas. Portanto o aumento na resistência à compressão na pequena parede foi proporcional ao ganho de área dado pelo grauteamento de seus vazios, diferentemente do comportamento observado nos prismas. / In the context of growth of structural masonry construction process, it highlight the use of the ceramic block consolidated with the creation of its specific standard of design, execution and control, the NBR 15812, Parts 1 and 2 (ABNT, 2010). Since the propagation of structural masonry, changes have occurred in the construction techniques, such as don\'t fill the vertical joints of the masonry wall. Another technique that has been used is the grouted masonry. However, it is not yet established if the unfilled vertical joints compromise the performance of masonry or which strength is necessary to the grout to increase the strength of the masonry. Therewith, the paper aims to contribute to the study of unfilled vertical joints by analyzing its effect on compressive strength and shear strength of small walls and also investigate the influence of grout in prisms and small walls under compression. With the analysis of the results we can conclude that do not fill the vertical joints had no influence on the values of compressive strength and elastic modulus of the small walls tested. However, it significantly affects the results of the diagonal compression test to evaluate shear strength, despite the shear elastic modulus being considered equivalent. The results of the preliminary study in prisms showed that the average of the compressive strength in relation to the gross area of the grouted prism using the Grout A and the Grout C were equivalent to the average of hollow prism. Thus, small walls and prisms with the Grout A were made. It can be concluded with the results of grouted small walls that there was a significant increase in compressive strength with respect to the gross area, but in relation to the net area, were similar to the hollow small wall. Therefore the increase in the compressive strength in a small wall is proportional to the gain of the area given by the grout, unlike the behavior observed in the prisms.
|
3 |
Modelagem computacional para avalia??o do efeito do n?o preenchimento das juntas verticais na resist?ncia da alvenaria estrutural / Computational modeling for evaluation of the nonfill effect of vertical joints in the strength of structural masonryFerreira, Anderson Albino 03 March 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-07-04T13:29:17Z
No. of bitstreams: 1
AndersonAlbinoFerreira_DISSERT.pdf: 5315680 bytes, checksum: 999fe3e6c74df532dc49b7549ac68b2f (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-07-12T13:47:03Z (GMT) No. of bitstreams: 1
AndersonAlbinoFerreira_DISSERT.pdf: 5315680 bytes, checksum: 999fe3e6c74df532dc49b7549ac68b2f (MD5) / Made available in DSpace on 2017-07-12T13:47:03Z (GMT). No. of bitstreams: 1
AndersonAlbinoFerreira_DISSERT.pdf: 5315680 bytes, checksum: 999fe3e6c74df532dc49b7549ac68b2f (MD5)
Previous issue date: 2017-03-03 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A alvenaria ? um material comp?sito, constitu?do basicamente por unidades e
juntas de argamassa (vertical e horizontal), podendo estar associada tamb?m a outros
materiais, como o a?o e o graute. No Brasil, a partir da d?cada de 80, a alvenaria
estrutural acabou se consolidando como um sistema construtivo altamente produtivo,
racional e econ?mico devido a caracter?sticas como: simplifica??o das t?cnicas de
execu??o, menor diversidade de materiais empregados, redu??o da m?o de obra e
rapidez na execu??o. Em alvenaria estrutural, uma das possibilidades de execu??o
que pode ser explorada ? o n?o preenchimento das juntas verticais, tamb?m chamada
de juntas secas. A ado??o desta pr?tica gera certas vantagens como a diminui??o no
tempo de execu??o da obra, a redu??o do consumo de materiais e a minimiza??o da
fissura??o provocada pelas deforma??es intr?nsecas, como retra??o e deforma??es
t?rmicas. No entanto, apesar de ser empregada a alguns anos no pa?s, as implica??es
decorrentes de seu uso muitas vezes n?o t?m sido consideradas de forma apropriada
nos projetos, isto se deve ao fato de existirem poucas pesquisas que tratam deste
assunto. Al?m disso, as pesquisas existentes, por vezes, apresentam resultados que
divergem entre si, principalmente no que se refere ? resist?ncia ? compress?o e ao
cisalhamento. Neste trabalho foram efetuadas simula??es num?ricas de pequenas
paredes de unidades cer?micas e de concreto, com e sem juntas verticais, ensaiadas
com as prescri??es da NBR 15812-2 (ABNT, 2010), NBR 15961-2 (ABNT, 2011) e NBR 14321 (ABNT, 1999), com a finalidade de avaliar a influ?ncia do n?o
preenchimento das juntas verticais na resist?ncia ? compress?o e ao cisalhamento da
alvenaria. Para a realiza??o das an?lises num?ricas foi utilizado o M?todo dos
Elementos Finitos a partir do software DIANA?. De acordo com os resultados
num?ricos obtidos nos modelos em compress?o, e da compara??o entre estes e os
resultados experimentais, foi poss?vel concluir que a aus?ncia das juntas verticais n?o
influenciou na resist?ncia ? compress?o da alvenaria. Contudo, a partir dos resultados
obtidos nos modelos em cisalhamento, conclui-se que n?o foi poss?vel avaliar
quantitativamente a influ?ncia das juntas verticais na resist?ncia ao cisalhamento da
alvenaria. / Masonry is a composite material, consisting basically of units and mortar joints (vertical
and horizontal), and may also be associated with other materials, such as steel and
grout. In Brazil, from the 1980s, structural masonry consolidated itself as a highly
productive, rational and economical construction system due to characteristics as:
simplification of execution techniques, less diversity of materials employed, reduction
of labor and speed execution. In structural masonry, one of the execution possibilities
that can be explored is the non-filling of vertical joints, also called dry joints. The
adoption of this practice generates certain advantages as the reduction in the
execution time of the construction, the reduction of the consumption of materials and
the minimization of the cracking caused by the intrinsic deformations, such as
retraction and thermal deformations. However, despite be employed to some years in
country, the implications of its use often has been not properly considered in the
projects, this is due to the fact that there is few research that deals with this subject.
Moreover, the existing researches sometimes present results that diverge from each
other, mainly with respect to the resistance to compression and shear. In this work,
numerical simulations of small walls of ceramic and concrete units, with and without
vertical joints, tested with the requirements of NBR 15812-2 (ABNT, 2010), NBR
15961-2 (ABNT, 2011) and NBR 14321 (ABNT, 1999). The purpose of this work was
to evaluate the influence of non-filling of vertical joints on the compressive strength and shear strength of the masonry. For the numerical analyzes, the Finite Element Method
was used from DIANA? software. According to the numerical results obtained in the
models in compression, and the comparison between these and the experimental
results, it was possible to conclude that the absence of the vertical joints did not
influence the compressive strength of the masonry. However, from the results obtained
in the shear models, it was concluded that it was not possible to quantitatively evaluate
the influence of the vertical joints on the shear strength of the masonry.
|
Page generated in 0.0327 seconds