• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Confecção e avaliação mecânica de implantes ortopédicos produzidos em poli (L-ácido lático) (PLLA) por impressoras 3D / Feasibility study orthopedic implant use polylactic acid produced in 3D printers production and biomechanics

GOES FILHO, Paulo Roberto Soares de 11 March 2016 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2016-07-19T14:03:24Z No. of bitstreams: 1 Paulo Roberto Soares de Goes Filho.pdf: 2065876 bytes, checksum: 66621844e9066623229e05142e75fead (MD5) / Made available in DSpace on 2016-07-19T14:03:24Z (GMT). No. of bitstreams: 1 Paulo Roberto Soares de Goes Filho.pdf: 2065876 bytes, checksum: 66621844e9066623229e05142e75fead (MD5) Previous issue date: 2016-03-11 / The objective of this work the production and biomechanical evaluation of structural orthopedic implants for fracture fixation in bioresorbable polymer, poly (lactide L) (PLLA) using a printing technique 3D deposition of layers of polymer melt for further experimental application in femur rabbit. For the production of implants, i.e. orthopedic plates curved section and locking screws it was taken as base femurs anatomy rabbits slaughtered for consumption which have had their dimensions and measured shapes as a reference for computer aided design (CAD) in specific program. The project was suitable for a three-dimensional modeling program controller of a printer in 3 dimensions printed, by deposition of layers, plates and orthopedic screws. The models were subjected to mechanical strength tests, three models of plates 4 and 6 holes with locking screw, and a plate anatomically optimized addition of a suitable screw type blocked plates. In the bending strength test with 4 points of support for 6 holes plate obtained values of 748 ± 62 N while the blocked plate 4 holes obtained values of 374 ± 42 N. The screw was subjected to peel strength testing in a polyurethane foam which simulates the cortical bone, the average value was 33 ± 6 N. the optimized anatomically plate obtained in the bending test after 662 ± 220N and irradiated with 40 kGy 193 ± 20N. From the point of view of mechanical resistance to bending test work showed the viability of producing structural orthopedic implants for fracture receiving little mechanical load although necessary in vivo tests that prove the effectiveness of the production technique and the material used. / Objetivou-se com este trabalho a produção e avaliação biomecânica de implantes ortopédicos estruturais para fixação de fraturas em polímero biorreabsorvível, o poli ( L- ácido lático) (PLLA) usando a técnica de impressão 3D por deposição de camadas de polímero fundido, para posterior aplicação experimental em fêmur de coelho. Para a produção dos implantes, isto é, placas ortopédicas de secção curva e parafusos bloqueados, foi tomada como base a anatomia de fêmures de coelhos abatidos para consumo que tiveram suas dimensões e formas aferidas como referência para um desenho assistido por computador em programa específico (CAD). O projeto foi adequado para um programa de modelagem tridimensional controlador de uma impressora em 3 dimensões que imprimiu, pela deposição de camadas, as placas e parafusos ortopédicos. Os modelos obtidos foram submetidos a testes mecânicos de resistência, sendo três modelos de placas, de 4 e 6 furos, com bloqueio de parafuso, e uma placa otimizada anatomicamente além de um modelo de parafuso adequado as placas bloqueadas. Em ensaio de resistência a flexão com 4 pontos de apoio a placa de 6 furos obteve valores de 748±62 N enquanto a placa bloqueada de 4 furos obteve valores de 374±29 N. O parafuso foi submetido a teste de força de arrancamento em uma espuma de poliuretano que simula osso cortical, o valor médio obtido foi de 33±6 N. A placa otimizada anatomicamente obteve no ensaio de flexão 662±220N e após irradiada com 40 KGy 193±20N. Do ponto de vista da resistência mecânica ao ensaio de flexão o trabalho mostrou a viabilidade de produzir implantes ortopédicos estruturais para fraturas que recebam pouca carga mecânica embora sejam necessários ensaios in vivo que comprovem a eficácia da técnica de produção e do material usado.

Page generated in 0.0792 seconds