• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Daily Image Guided Radiation Therapy for Prostate Cancer: An assessment of treatment plan reproducibility.

Knight, Kellie Ann January 2006 (has links)
Doctor of Health Science / It is well documented that for prostate cancer patients undergoing radiation therapy there is a correlation between target volume displacement and changes in bladder and rectal volumes. However, these studies have used a methodology that has captured only a subset of all treatment positions. This research used daily Computer Tomography (CT) imaging to comprehensively assess organ volumes, organ motion and their effect on dose, something that has never been performed previously, thus adding considerably to the understanding of the topic. Daily CT images were obtained using a Siemens Primus Linear Accelerator equipped with an in-room Somatom CT unit in the accelerator suite, marketed as ‘Primatom’, to accurately position the patient prior to treatment delivery. The internal structures of interest were contoured on the planning workstation by the investigator. The daily volume and location of the organs were derived from the computer to assess and analyse internal organ motion. The planned dose distribution was then imported onto the treatment CT datasets and used to compare the planned dose to i) the actual isocentre, where the isocentre was actually placed for that fraction, ii) the uncorrected isocentre, by un-doing any on-line corrections performed by the treatment staff prior to treatment delivery, and iii) the future isocentre, by placing the isocentre relative to internal organ motion on a daily basis. The results of this study did not confirm a statistically significant decrease in rectum volumes over time (hypothesis 1), however large fluctuations in bladder volume were confirmed (hypothesis 2). Internal organ motion for the rectum and bladder was demonstrated to be related to organ filling. Ideal planning volumes for these organs have been reported to minimise systematic and random uncertainty in the treatment volumes. An observed decrease in prostate volume over time, a systematic uncertainty in the location of the prostate at the time of the planning CT scan and a significant relationship between prostate centre of volume and rectum and bladder volumes has resulted in a recommendation that patients should be re-scanned during treatment to ensure appropriate clinical target volume coverage. A significant relationship between rectal and bladder volumes and the dose delivered to these organs was found (hypothesis 3). The dose delivered to the planning target volume was not related to the rectal or bladder volumes, although it was related to the motion of these organs. Despite these results only minimal effects on the dose delivered to any of the three isocentres occurred, indicating that the planned dose was accurately delivered using the methodology presented here (hypothesis 4). However the results do indicate that the patient preparation instructions need to be improved if margins are to be reduced in the future. It is unrealistic to assume that Image Guided Radiation Therapy will ever become routine practice due to infrastructure costs and time limitations. This research will inform radiation therapy centres of the variables associated with prostate cancer treatment on a daily basis, something that has never before been realistically achievable. As a result centres will be able to devise protocols to improve treatment outcomes.
2

The effect of fill density on rectal balloon dosimetry

Teye, Vida Dede 04 May 2013 (has links)
Access to abstract permanently restricted to Ball State community only. / Literature review -- Interaction of radiation with matter -- Radiation dosimetry -- Materials and methods -- Results -- Discursion. / Access to thesis permanenty restricted to Ball State community only. / Department of Physics and Astronomy
3

Daily Image Guided Radiation Therapy for Prostate Cancer: An assessment of treatment plan reproducibility.

Knight, Kellie Ann January 2006 (has links)
Doctor of Health Science / It is well documented that for prostate cancer patients undergoing radiation therapy there is a correlation between target volume displacement and changes in bladder and rectal volumes. However, these studies have used a methodology that has captured only a subset of all treatment positions. This research used daily Computer Tomography (CT) imaging to comprehensively assess organ volumes, organ motion and their effect on dose, something that has never been performed previously, thus adding considerably to the understanding of the topic. Daily CT images were obtained using a Siemens Primus Linear Accelerator equipped with an in-room Somatom CT unit in the accelerator suite, marketed as ‘Primatom’, to accurately position the patient prior to treatment delivery. The internal structures of interest were contoured on the planning workstation by the investigator. The daily volume and location of the organs were derived from the computer to assess and analyse internal organ motion. The planned dose distribution was then imported onto the treatment CT datasets and used to compare the planned dose to i) the actual isocentre, where the isocentre was actually placed for that fraction, ii) the uncorrected isocentre, by un-doing any on-line corrections performed by the treatment staff prior to treatment delivery, and iii) the future isocentre, by placing the isocentre relative to internal organ motion on a daily basis. The results of this study did not confirm a statistically significant decrease in rectum volumes over time (hypothesis 1), however large fluctuations in bladder volume were confirmed (hypothesis 2). Internal organ motion for the rectum and bladder was demonstrated to be related to organ filling. Ideal planning volumes for these organs have been reported to minimise systematic and random uncertainty in the treatment volumes. An observed decrease in prostate volume over time, a systematic uncertainty in the location of the prostate at the time of the planning CT scan and a significant relationship between prostate centre of volume and rectum and bladder volumes has resulted in a recommendation that patients should be re-scanned during treatment to ensure appropriate clinical target volume coverage. A significant relationship between rectal and bladder volumes and the dose delivered to these organs was found (hypothesis 3). The dose delivered to the planning target volume was not related to the rectal or bladder volumes, although it was related to the motion of these organs. Despite these results only minimal effects on the dose delivered to any of the three isocentres occurred, indicating that the planned dose was accurately delivered using the methodology presented here (hypothesis 4). However the results do indicate that the patient preparation instructions need to be improved if margins are to be reduced in the future. It is unrealistic to assume that Image Guided Radiation Therapy will ever become routine practice due to infrastructure costs and time limitations. This research will inform radiation therapy centres of the variables associated with prostate cancer treatment on a daily basis, something that has never before been realistically achievable. As a result centres will be able to devise protocols to improve treatment outcomes.
4

Post implant dosimetric analysis for prostate brachytherapy

Haworth, Annette January 2005 (has links)
[Truncated abstract] Purpose: Permanent prostate brachytherapy (PPB) as a treatment option for prostate cancer requires implantation of 80-150 radioactive iodine-125 (I-125)
5

Acquired resistance to irradiation or docetaxel is not associated with cross‑resistance to cisplatin in prostate cancer cell lines

Donix, Lukas, Erb, Holger H. H., Peitzsch, Claudia, Dubrovska, Anna, Pfeifer, Manuel, Thomas, Christian, Fuessel, Susanne, Erdmann, Kati 02 February 2024 (has links)
Purpose: Platinum chemotherapy can be considered to treat metastatic castration-resistant prostate cancer (mCRPC) with features of neuroendocrine differentiation. However, platinum compounds are generally only applied after the failure of multiple prior-line treatment options. This study investigated whether acquired resistance against ionizing radiation or docetaxel chemotherapy—two commonly applied treatment modalities in prostate cancer—influences the cisplatin (CDDP) tolerance in mCRPC cell line models. Methods: Age-matched parental as well as radio- or docetaxel-resistant DU145 and PC-3 cell lines were treated with CDDP and their sensitivity was assessed by measurements of growth rates, viability, apoptosis, metabolic activity and colony formation ability. Results: The data suggest that docetaxel resistance does not influence CDDP tolerance in all tested docetaxel-resistant cell lines. Radio-resistance was associated with sensitization to CDDP in PC-3, but not in DU145 cells. In general, DU145 cells tolerated higher CDDP concentrations than PC-3 cells regardless of acquired resistances. Furthermore, non-age-matched treatment-naïve PC-3 cells exhibited significantly different CDDP tolerances. Conclusion: Like patients, different mCRPC cell lines exhibit significant variability regarding CDDP tolerance. The presented in vitro data suggest that previous radiation treatment may be associated with a moderate sensitization to CDDP in an isogenic and age-matched setting. Therefore, previous radiotherapy or docetaxel chemotherapy might be no contraindication against initiation of platinum chemotherapy in selected mCRPC patients.

Page generated in 0.1176 seconds