• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 19
  • 19
  • 16
  • 10
  • 9
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Antioxidant Polymorphisms and Susceptibility to Solvent- Induced Hearing Loss in Factory Workers

Glazier, Robert Udell 13 September 2010 (has links)
Occupational exposure-related hearing loss is a significant health concern for affected workers. Organic solvent exposure has emerged as an important contributor to hearing loss. It is thought that hearing loss related to solvent and noise exposure is mediated by reactive oxygen species (ROS). The glutathione associated enzymes and the manganese superoxide dismutase enzymes (SOD2) are important components of the cochlear hair cellâs defense against oxidative stress. This study is aimed to determine whether polymorphisms within the glutathione S-transferases (GST) P1 and GSTM1, glutathione peroxidase 1 (GPX1), and SOD2 are associated with hearing status in solvent exposed factory workers. Genotypes for the GSTM1 + vs. null, GSTP1 Ile105Val, GPX1 Pro198Leu, SOD2 Val16Ala polymorphisms along with hearing status were determined in factory workers exposed to organic solvents. Hearing tests consisted of pure tone audiometric (PTA) thresholds from 3-6 kHz and distortion product otoacoustic emissions (DPOAEs) for 3-6 kHz. Bivariate and multivariate regression analysis was undertaken to assess for association between polymorphisms and hearing outcomes. The GSTP1 Val/Ile genotype at position 105 was associated with higher PTA thresholds (β=12.41, P value= 0.01) from 3-6 kHz in workers below age 22-43. The analysis showed a protective association of the SOD2 Ala/Val genotype (β= -26.42, P value= 0.025) and The GPX1 Leu/Leu genotypes (β=47.81, P value= 0.034) with audiometric thresholds from 3-6 kHz in individuals above age 43. This small cross-sectional study suggests that polymorphisms within the antioxidant system may alter susceptibility to hearing loss in workers exposed to organic solvents. These results also suggest the mechanisms by which this affect are mediated are complex and should be further investigated.
12

The feasibility of including Distortion Product Otoacoustic Emissions (DPOAEs) in the annual medical surveillance test battery for the identification of noise-induced hearing loss in a group of workers in a beverage manufacturing industry.

Reddy, Tarryn Marisca. 29 November 2013 (has links)
The study investigated the feasibility of including DPOAEs in the annual medical surveillance test battery for the identification of NIHL in a group of employees in a manufacturing industry in KwaZulu-Natal. Feasibility was investigated by exploring the sensitivity, specificity and predictive efficiency of DPOAEs, the ability of DPOAEs to detect subtle noise-induced cochlea changes, the test-retest reliability of DPOAEs and lastly, the duration of time taken to conduct the DPOAE test bilaterally. A cross-sectional and repeated measures within-in participant design was utilized in the study. A purposive convenience sampling technique was used, as well as a stratified sampling approach in order to realize objective two of the study. The study consisted of 60 participants, which were further stratified into four test groups, i.e. Group A: 0-3 years, Group B: 3.1-6 years and Group C: 6.1-9 years and Group D: 9.1-13 years of working within the beverage manufacturing industry. A high sensitivity and negative predictive value was reported in the current study, suggesting that DPOAEs may be able to identify those who present with subtle cochlea changes as a result of exposure to occupational noise. The sensitivity of DPOAEs was 100% at 1, 2, 4, 6 and 8kHz in the right ear and at 4 and 6kHz in the left ear. The specificity of DPOAEs in the current study ranged between 55%-97% across the frequency range in the right ear and 49%-88% in the left ear. A negative predictive value of 100% was obtained bilaterally across the frequency range, except at 8kHz in the left ear. Visual inspection of the DPgram in the current study revealed a bilateral reduction in DPOAE amplitudes for all test groups in the high frequency region of the DP-Gram, namely, 5477Hz and 7303Hz, in the absence of a statistically significant difference (p>0.05). A greater frequency range appears to be affected in this group of workers, indicating that the type of noise, namely, impulse noise, may result in cochlea changes. Corresponding changes on the pure tone audiogram were not observed, however, noise notch configurations were observed for the groups with a longer history of noise exposure. This was not seen bilaterally as is typically expected with NIHL. Good test-retest reliability across the frequency range obtained in the current study further indicates the feasibility of including DPOAEs in the annual medical surveillance test battery. Additionally, the current study calculated an average of 86 seconds (1 minute 26 seconds) to conduct the DPOAE test bilaterally, confirming that DPOAEs are a quick test to administer. The findings of this study suggest that DPOAEs may be used to monitor early subtle noise-induced cochlea changes for workers exposed to noise in the beverage manufacturing industry as part of the annual medical surveillance test battery. / Thesis (M.Comm.Path.)-University of KwaZulu-Natal, Westville, 2013.
13

Transducer influence on Auditory Steady State Evoked Potentials

Marais, Jacobus Johannes 12 January 2005 (has links)
Preliminary studies have stirred the hope that sound-field stimulation through auditory steady state evoked potentials can be used to assess aided thresholds in the difficult-to-test population. Before the introduction of ASSEP into the clinical field, as a technique for the prediction of aided thresholds in the difficult-to-test population, a question arises concerning its clinical validation. The application of ASSEP through sound field stimulation, in the determination of aided thresholds and for the evaluation of amplification fittings, is dependent on the determination of unaided responses. Subsequently the estimation of unaided thresholds in the hearing impaired population is dependent on the establishment of normative data from the normal hearing population. The aim of this study was to determine the influence of insert earphones and sound field speaker presentation on threshold estimations using monotic auditory steady state evoked potentials, in a group of normal hearing adults. To achieve the aim of the study, a comparative, within-group experimental design was selected. The results of the current study indicated that the monotic single ASSEP technique under both insert earphone- and sound field conditions provided a reasonable estimation (25-35 dB HL for inset earphones; 20-33 dB HL for sound field speaker presentation) of the behavioural pure tone thresholds. The minimum response levels obtained under insert earphone conditions differed significantly from those obtained under sound field conditions for all the frequencies tested except 2 kHz (p < 0.01). Subsequently, the current study indicates that minimum response levels obtained using a specific transducer should serve as the basis of comparison with behavioural thresholds obtained under the same transducer. Therefore, behavioural pure tone thresholds obtained under insert earphone conditions will not suffice as a basis of comparison for minimum response levels obtained for the ASSEP technique under sound field conditions, and vice versa. This research endeavour concluded that the monotic ASSEP technique under both insert earphone and sound field conditions provide useful information for the estimation of frequency specific thresholds, but that the results are transducer specific and that comparison across transducers should be avoided. / Dissertation (M (Communication Pathology))--University of Pretoria, 2006. / Speech-Language Pathology and Audiology / Unrestricted
14

Audiometr pro audiometrii čistými tóny / Pure tone audiometer

Blahák, Petr January 2010 (has links)
Human hearing is to collect information from the outside world and is one of the basic human senses. Part of this thesis is devoted to acoustics, properties of the human ear in terms of perception of sounds and methods, which human ears are investigating. Audiometer is an instrument which is most often used in healthcare. The main content of this thesis is to design pure tone audiometer, which is important for the subjective tests of human hearing non-invasive method.
15

Prevalence and Degree of Hearing Loss Among Males in Beaver Dam Cohort: Comparison of Veterans and Nonveterans

Wilson, Richard H., Noe, Colleen M., Cruickshanks, Karen J., Wiley, Terry L., Nondahl, David M. 30 September 2010 (has links)
The Epidemiology of Hearing Loss Study (EHLS) conducted in Beaver Dam, Wisconsin, was a population-based study that focused on the prevalence of hearing loss among 3,753 participants between 1993 and 1995. This article reports the results of several auditory measures from 999 veteran and 590 nonveteran males 48 to 92 years of age included in the EHLS. The auditory measures included pure tone thresholds, tympanometry and acoustic reflexes, word recognition in quiet and in competing message, and the Hearing Handicap Inventory for the Elderly-Screening (HHIE-S) version. Hearing loss in the auditory domains of pure tone thresholds, word recognition in quiet, and word recognition in competing message increased with age but were not significantly different for the veterans and nonveterans. No significant differences were found between participant groups on the HHIE-S; however, regarding hearing aid usage, mixed differences were found.
16

Confiabilidade do exame de audiometria tonal baseado no cálculo de incerteza de medição ISO 8253-1:2010 / Reliability of the pure-tone audiometry based on calculation of the measurement uncertainty - ISO 8253-1:2010

Silva, Denise Torreão Corrêa da 16 February 2016 (has links)
Made available in DSpace on 2016-04-27T18:12:12Z (GMT). No. of bitstreams: 1 Denise Torreao Correa da Silva.pdf: 13435475 bytes, checksum: 0ee13ef29957b217cb6d5b50c30944cf (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / To estimate the measurement uncertainty of the pure-tone audiometry by air-conduction, in the frequencies from 250 Hz to 8000 Hz, and bone-conduction, at frequencies of 500 Hz to 4000 Hz. Method: This is an observational, descriptive and cross sectional study. Accuracy measurement tests under repeatability conditions were conducted (same measurement procedure, operator, measuring system, operating conditions and site, in a short time interval). Each of the nine participants took part in two trials with five repetitions each through air and bone conduction, in the right and left ear. In Trial 1 the interval between each repetition was five minutes. In Trial 2 the interval between repetitions was sixty minutes. To calculate the combined uncertainty the type A uncertainty, derived from repeatability, and Type B uncertainty derived from the audiometer calibration certificate, the audiometer resolution, and the conditions of the test environment were considered. Results: There was no statistically significant difference intra-individuals in different time intervals (p> 0,05), in both air and bone conduction. The median of type A uncertainty ranged from 0 dB to 2,7 dB in the right ear, and 0 dB to 3,5 dB in the left ear for air conduction. In bone conduction the median of type A uncertainty ranged from 2.2 dB to 2.7 dB in both ears. Type B uncertainties, for air and bone conduction, derived from the contribution of the equipment used for the test (0,4 dB), of the equipment resolution (1,4 dB), and the test environment (5,0 dB). Considering the median of type A uncertainty derived from accuracy measurement, and type B uncertainties mentioned above, the estimated of measurement uncertainty of pure tone audiometry, air and bone conduction, in this study, for the confidence level of 95% (k=1.96) and 95.45% (k=2.0) were 10 dB or 11 dB, for the frequencies tested, in both Trials 1 and Trial 2, in both ears. Conclusions: This study demonstrates the feasibility of accuracy measurement tests under repeatability conditions, as proposed in this work. In this study the contribution of type B uncertainties, derived from the audiometer calibration certificate, potentiometer and test environment, this latter being more prevalent, was higher than that of type A uncertainty derived from repeatability, indicating the need to keep control of these variables. The expression of measurement uncertainty can increase even more the sensitivity and specificity of audiometry, respectively increasing the rate of true positives and true negatives, since it is considered the gold standard. In this study the expanded uncertainty, for the confidence level of 95% and 95,45% ranged between 10 and 11 dB, in air and bone conduction. The reliability of the pure-tone audiometry test depends on the expression of its uncertainty; only so results obtained with the same subject in different places and times can be compared. Therefore the expression of uncertainty should be taken into consideration when delivering results and in preparing reports, for subsidizing decisions on hearing aids prescription, selection and adaptation procedures, as well as assessment of social security benefit payments, labor actions and health surveillance actions / Estimar a Incerteza de Medição no exame de audiometria tonal por via aérea, nas frequências de 250 Hz a 8 000 Hz, e por via óssea, nas frequências de 500 Hz a 4 000 Hz. Método: Nesta pesquisa, de natureza observacional, descritiva e transversal, foram realizados ensaios de precisão de medição sob condições de repetibilidade (mesmo procedimento de medição, operador, sistema de medição, condições de operação e mesmo local, em curto intervalo de tempo). Cada um dos nove participantes realizou dois ensaios, com cinco repetições de audiometria cada, por vias aérea e óssea, orelhas direita e esquerda. No Ensaio 1 o intervalo entre cada repetição foi de cinco minutos. No Ensaio 2 o intervalo entre as repetições foi de sessenta minutos. Para cálculo da incerteza padrão combinada considerou-se a incerteza do tipo A, derivada da repetibilidade, e as incertezas do tipo B, derivadas do certificado de calibração do audiômetro, da resolução do audiômetro, e das condições do ambiente de teste. Resultados: Para as vias aérea e óssea não houve diferença estatisticamente significante intraindivíduos nos diferentes intervalos de tempo (p > 0,05). A mediana da incerteza do tipo A variou de 0 dB a 2,7 dB, na orelha direita, e de 0 dB a 3,5 dB na orelha esquerda, para a via aérea. Na via óssea a mediana da incerteza do tipo A variou de 2,2 dB a 2,7 dB, em ambas as orelhas. As incertezas do tipo B, tanto para via aérea quanto para a via óssea, foram derivadas da contribuição do equipamento utilizado para o exame (0,4 dB), da resolução do equipamento (1,4 dB), e do ambiente de teste (5,0 dB). Levando-se em consideração a mediana das incertezas do tipo A e as incertezas do tipo B citadas acima, a estimativa da incerteza de medição da audiometria tonal por vias aérea e óssea, neste estudo, para os níveis da confiança de 95% (k=1,96) e 95,45% (k=2,0), foi de 10 dB ou 11 dB, nas frequências testadas, tanto no Ensaio 1 quanto no Ensaio 2, em ambas as orelhas. Conclusões: Este estudo demonstra a viabilidade de ensaios de precisão de medição sob condições de repetibilidade, conforme proposto neste trabalho. Neste estudo a contribuição das incertezas do tipo B, derivadas do certificado de calibração do audiômetro, do potenciômetro e do ambiente de teste, preponderando esta última, foi maior do que a incerteza do tipo A, derivada da repetibilidade, indicando a necessidade de manter-se controle sobre estas variáveis. A expressão da incerteza de medição da audiometria pode elevar, ainda mais, a sensibilidade, e a especificidade da audiometria, respectivamente aumentando a taxa de verdadeiros positivos e de verdadeiros negativos, uma vez que é considerada padrão ouro. Neste estudo a incerteza de medição expandida, para os níveis da confiança de 95% e 95,45% variou entre 10 dB e 11 dB, tanto para via aérea quanto para via óssea. A confiabilidade do exame de Audiometria Tonal, ou Audiometria de Tons Puros depende da expressão de sua incerteza; somente assim resultados obtidos com o mesmo sujeito, em locais e épocas diferentes, podem ser comparados. Portanto a expressão da incerteza deve ser levada em consideração quando da entrega de resultados e confecção de relatórios, seja para decisão sobre procedimentos de indicação, seleção e adaptação de aparelhos de amplificação sonora individual, assim como para avaliação de concessão de benefícios previdenciários, ações trabalhistas e ações de vigilância em saúde
17

Avaliação da audição em criança de 3 a 6 anos, em creches e pré-escolas municipais, de São José do Rio Preto, São Paulo.

Piatto, Vânia Belintani 18 December 1998 (has links)
Made available in DSpace on 2016-01-26T12:51:51Z (GMT). No. of bitstreams: 1 vaniapiatto_dissert.pdf: 265912 bytes, checksum: d6bd354613ca0a9752b4acad6612d8cd (MD5) Previous issue date: 1998-12-18 / The aim of this study was to evaluate the hearing and the prevalence of hearing impairment among children, in the age groups of 3 to 6 years old, from Municipal Nursery and Pre-schools of São José do Rio Preto, S.P. At first stage, audiometries in a free field were performed for screening in 103 children, both sexes in 8 Nursery and 8 Pre-schools previously selected. At second stage, the ones who presented audiometric alterations were referred to the Phonoaudiological Service of FAMERP to perform conventional pure tone audiometer. The classification of hearing impairment in relation to grade was made according to W.H.O. approaches. A male child (0.97%) was found with light grade of conductive hearing impairment in the left ear ( LE=35 dB). There was no significant difference among the ratio of hearing impairment in both sexes (p=1.00). Nine children (8.73%) showed alterations in the hearing thresholds by air conduction in 4000, 6000 and/or 8000 Hz sharp frequencies. The ratio among alterations in these frequencies was not statistically significant in both sexes (p=1.00). There is need of further studies to evaluate the result found in children with alterations in those sharp frequencies. The found prevalence of hearing impairment in this studied population can chek the need of use of prevention programs and earlier diagnosis of hearing impairments. / Este estudo teve como objetivo realizar a avaliação da audição e o levantamento da prevalência de deficiência auditiva em amostra de crianças, na faixa etária de 3 a 6 anos, em creches e pré-escolas municipais de São José do Rio Preto, etapa, em 103 crianças de ambos os sexos, na referida faixa etária, em 8 creches e 8 pré-escolas previamente selecionadas. As crianças que apresentaram alterações audiométricas na triagem, foram encaminhadas ao ambulatório de fonoaudiologia da famerp para realização de audiometria tonal convencional, em uma segunda etapa. A classificação da deficiência auditiva, em relação ao grau, foi feita segundo os critérios da oms. Foi encontrado uma criança do sexo masculino (0,97%) com deficiência auditiva condutiva de grau leve na orelha esquerda (m oe=35 db). Não houve diferença significativa entre as proporções de deficiência auditiva em ambos os auditivas, por via aérea, nas freqüências agudas de 4000, 6000 e/ ou 8000 hz. Nota de Resumo Não foi estatisticamente significante a diferença entre as proporções de alterações nas freqüências acima descritas em ambos os sexos (p=1,00). Há necessidade de posteriores estudas para avaliação do resultado encontrado em relação ás crianças com alterações nas referidas freqüências agudas. A prevalênciaencontrada de deficiência auditiva na população do estudo, pode comprovar a necessidade da implantação de programas de prevenção e diagnóstico precoce da deficiência auditiva. Unitermos: surdez- métodos de avaliação, classificação; crianças- pré-escolares; audiometria-tonal, da fala.
18

Avaliação da audição em criança de 3 a 6 anos, em creches e pré-escolas municipais, de São José do Rio Preto, São Paulo

Piatto, Vânia Belintani 18 December 1998 (has links)
Made available in DSpace on 2016-01-26T12:51:49Z (GMT). No. of bitstreams: 1 vaniapiatto_dissert.pdf: 265912 bytes, checksum: d6bd354613ca0a9752b4acad6612d8cd (MD5) Previous issue date: 1998-12-18 / The aim of this study was to evaluate the hearing and the prevalence of hearing impairment among children, in the age groups of 3 to 6 years old, from Municipal Nursery and Pre-schools of São José do Rio Preto, S.P. At first stage, audiometries in a free field were performed for screening in 103 children, both sexes in 8 Nursery and 8 Pre-schools previously selected. At second stage, the ones who presented audiometric alterations were referred to the Phonoaudiological Service of FAMERP to perform conventional pure tone audiometer. The classification of hearing impairment in relation to grade was made according to W.H.O. approaches. A male child (0.97%) was found with light grade of conductive hearing impairment in the left ear ( LE=35 dB). There was no significant difference among the ratio of hearing impairment in both sexes (p=1.00). Nine children (8.73%) showed alterations in the hearing thresholds by air conduction in 4000, 6000 and/or 8000 Hz sharp frequencies. The ratio among alterations in these frequencies was not statistically significant in both sexes (p=1.00). There is need of further studies to evaluate the result found in children with alterations in those sharp frequencies. The found prevalence of hearing impairment in this studied population can chek the need of use of prevention programs and earlier diagnosis of hearing impairments. / Este estudo teve como objetivo realizar a avaliação da audição e o levantamento da prevalência de deficiência auditiva em amostra de crianças, na faixa etária de 3 a 6 anos, em creches e pré-escolas municipais de São José do Rio Preto, etapa, em 103 crianças de ambos os sexos, na referida faixa etária, em 8 creches e 8 pré-escolas previamente selecionadas. As crianças que apresentaram alterações audiométricas na triagem, foram encaminhadas ao ambulatório de fonoaudiologia da famerp para realização de audiometria tonal convencional, em uma segunda etapa. A classificação da deficiência auditiva, em relação ao grau, foi feita segundo os critérios da oms. Foi encontrado uma criança do sexo masculino (0,97%) com deficiência auditiva condutiva de grau leve na orelha esquerda (m oe=35 db). Não houve diferença significativa entre as proporções de deficiência auditiva em ambos os auditivas, por via aérea, nas freqüências agudas de 4000, 6000 e/ ou 8000 hz. Nota de Resumo Não foi estatisticamente significante a diferença entre as proporções de alterações nas freqüências acima descritas em ambos os sexos (p=1,00). Há necessidade de posteriores estudas para avaliação do resultado encontrado em relação ás crianças com alterações nas referidas freqüências agudas. A prevalênciaencontrada de deficiência auditiva na população do estudo, pode comprovar a necessidade da implantação de programas de prevenção e diagnóstico precoce da deficiência auditiva. Unitermos: surdez- métodos de avaliação, classificação; crianças- pré-escolares; audiometria-tonal, da fala.
19

Recognition Performance on Words Interrupted (10 Ips, 50% Duty Cycle) With Two Interruption Patterns Referenced to Word Onset: Young Listeners With Normal Hearing for Pure Tones and Older Listeners With Sensorineural Hearing Loss

Wilson, Richard H., Irish, Staci E. 01 January 2015 (has links)
OBJECTIVE: To determine in an interrupted word paradigm (Maryland CNCs; 10 ips, 50% duty cycle) if different locations of the interruption pattern produce different recognition performances. DESIGN: Repeated measures using two interruption patterns that were complementary halves referenced to word onset; one started with word onset (0-ms), the other started 50 ms later. The hypothesis was that recognition performance would be better on the 0-ms condition than on the 50-ms condition, but there would be some words with the reverse relation. STUDY SAMPLE: Twenty-four young adults with normal hearing for pure tones and 32 older adults (mean = 67 years) with sensorineural hearing loss participated. RESULTS: With the young listeners mean recognition performance on the 0-ms condition (63.1%) was significantly better than the mean performance on the 50-ms condition (47.8%). About twice as many words had better performance on the 0-ms condition. With the older listeners, who were given only stimuli on which performances were > 58% by the young normals, performances on the two conditions were the same. CONCLUSIONS: The hypothesis was supported with the young listeners. The equal performance by the older listeners on the two conditions was attributed to the manner in which the words were selected.

Page generated in 0.0464 seconds