• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An?lise de um queimador infravermelho funcionando com combust?vel h?brido : GLP/Bio-?leo

Azevedo Neto, Alu?sio 19 November 2010 (has links)
Made available in DSpace on 2014-12-17T14:08:43Z (GMT). No. of bitstreams: 1 AluisioAN_DISSERT.pdf: 2010955 bytes, checksum: 9d4c76c749552efd65c7156a389b51c8 (MD5) Previous issue date: 2010-11-19 / Universidade Federal do Rio Grande do Norte / Biomass is considered the largest renewable energy source that can be used in an environmentally sustainable. From the pyrolysis of biomass is possible to obtain products with higher energy density and better use properties. The liquid resultant of this process is traditionally called bio-oil. The use of infrared burners in industrial applications has many advantages in terms of technical-operational, for example, uniformity in the heat supply in the form of radiation and convection, with a greater control of emissions due to the passage of exhaust gases through a macroporous ceramic bed. This paper presents a commercial infrared burner adapted with an ejector proposed able to burn a hybrid configuration of liquefied petroleum gas (LPG) and bio-oil diluted. The dilution of bio-oil with absolute ethanol aimed to decrease the viscosity of the fluid, and improving the stability and atomization. It was introduced a temperature controller with thermocouple modulating two stages (low heat / high heat), and solenoid valves for fuels supply. The infrared burner has been tested, being the diluted bio-oil atomized, and evaluated its performance by conducting energy balance. The method of thermodynamic analysis to estimate the load was used an aluminum plate located at the exit of combustion gases and the distribution of temperatures measured by thermocouples. The dilution reduced the viscosity of the bio-oil in 75.4% and increased by 11% the lower heating value (LHV) of the same, providing a stable combustion to the burner through the atomizing with compressed air and burns combined with LPG. Injecting the hybrid fuel there was increase in the heat transfer from the plate to the environment in 21.6% and gain useful benefit of 26.7%, due to the improved in the efficiency of the 1st Law of Thermodynamics of infrared burner / A biomassa ? considerada a maior fonte renov?vel de energia, podendo ser usada de forma ambientalmente sustent?vel. A partir da pir?lise da biomassa ? poss?vel a obten??o de produtos com maior densidade energ?tica e propriedades de uso melhores. O l?quido resultante do seu processo ? tradicionalmente chamado de bio-?leo. A utiliza??o de queimadores infravermelhos em aplica??es industriais apresenta muitas vantagens do ponto de vista t?cnico-operacional, como por exemplo, homogeneidade no fornecimento de calor, na forma de radia??o e convec??o, apresentando um maior controle das emiss?es devido ? passagem dos gases de exaust?o atrav?s de um leito cer?mico macroporoso. O presente trabalho apresenta um queimador infravermelho comercial adaptado com um ejetor proposto capaz de queimar numa configura??o h?brida de g?s liquefeito de petr?leo (GLP) e bio-?leo dilu?do. A dilui??o do bio-?leo com ?lcool et?lico absoluto teve como principal objetivo diminuir a viscosidade do fluido, e melhorar a estabilidade e a atomiza??o. Foi introduzido um controlador de temperatura com termopar modulando dois est?gios (fogo baixo/alto), e eletrov?lvulas para alimenta??o dos combust?veis. O queimador infravermelho foi submetido a testes e ensaios, sendo atomizado o bio-?leo dilu?do, e avaliado o seu desempenho mediante a realiza??o de balan?o de energia. Como m?todo de an?lise termodin?mica para estimativa de carga foi utilizado uma placa de alum?nio localizada na sa?da dos gases de combust?o, sendo a distribui??o de temperaturas medida por termopares. A dilui??o reduziu a viscosidade do bio-?leo em 75,4% e aumentou em 11% o poder calor?fico inferior do mesmo, propiciando ao queimador uma combust?o est?vel atrav?s da atomiza??o com o ar comprimido e queima conjunta com GLP. Injetando o combust?vel h?brido houve aumento na transfer?ncia de calor da placa para o meio ambiente em 21,6% e ganho energ?tico ?til de 26,7%, em fun??o da melhora na efici?ncia da 1? Lei da Termodin?mica do queimador infravermelho
2

An?lise do desempenho de um queimador infravermelho funcionando com g?s liquefeito de petr?leo e glicerina

Dantas, Marcello Ara?jo 31 May 2010 (has links)
Made available in DSpace on 2014-12-17T14:08:39Z (GMT). No. of bitstreams: 1 MarcelloAD_DISSERT.pdf: 3032114 bytes, checksum: 1b49aa6af338e06fe387bb398cc85b4b (MD5) Previous issue date: 2010-05-31 / The use of infrared burners in industrial applications has many advantages in terms of technical-operational, for example, uniformity in the heat supply in the form of radiation and convection, with greater control of emissions due to the passage of exhaust gases through a macro-porous ceramic bed. This paper presents an infrared burner commercial, which was adapted an experimental ejector, capable of promoting a mixture of liquefied petroleum gas (LPG) and glycerin. By varying the percentage of dual-fuel, it was evaluated the performance of the infrared burner by performing an energy balance and atmospheric emissions. It was introduced a temperature controller with thermocouple modulating two-stage (low heat / high heat), using solenoid valves for each fuel. The infrared burner has been tested and tests by varying the amount of glycerin inserted by a gravity feed system. The method of thermodynamic analysis to estimate the load was used an aluminum plate located at the exit of combustion gases and the distribution of temperatures measured by a data acquisition system which recorded real-time measurements of the thermocouples attached. The burner had a stable combustion at levels of 15, 20 and 25% of adding glycerin in mass ratio of LPG gas, increasing the supply of heat to the plate. According to data obtained showed that there was an improvement in the efficiency of the 1st Law of infrared burner with increasing addition of glycerin. The emission levels of greenhouse gases produced by combustion (CO, NOx, SO2 and HC) met the environmental limits set by resolution No. 382/2006 of CONAMA / A utiliza??o de queimadores infravermelhos em aplica??es industriais apresenta muitas vantagens do ponto de vista t?cnico-operacional, como por exemplo, homogeneidade no fornecimento de calor, na forma de radia??o e convec??o, apresentando um maior controle das emiss?es devido ? passagem dos gases de exaust?o atrav?s de um leito cer?mico macroporoso. O presente trabalho apresenta um queimador infravermelho comercial, no qual foi adaptado um ejetor experimental, capaz de promover uma mistura de g?s liquefeito de petr?leo (GLP) e glicerina. Atrav?s da varia??o de percentuais de combust?vel dual, foi avaliado o desempenho do queimador infravermelho mediante a realiza??o de um balan?o de energia e das emiss?es atmosf?ricas. Foi introduzido um controlador de temperatura com termopar modulando dois est?gios (fogo baixo/alto), utilizando v?lvulas solen?ides para cada combust?vel. O queimador infravermelho foi submetido a testes e ensaios variando-se a quantidade de glicerina inserida por um sistema de alimenta??o por gravidade. Como m?todo de an?lise termodin?mica para estimativa de carga foi utilizada uma placa de alum?nio localizada na sa?da dos gases de combust?o, sendo a distribui??o de temperaturas medida por um sistema de aquisi??o de dados que registrou em tempo real as medidas dos termopares afixados. O queimador apresentou uma combust?o est?vel para os n?veis de 15, 20 e 25 % de adi??o de glicerina em raz?o m?ssica de GLP, aumentando o fornecimento de calor para a placa. Pelos dados obtidos, observou-se que houve uma melhora na efici?ncia de 1? Lei do queimador infravermelho quando ocorre o aumento de adi??o da glicerina na mistura. Os n?veis de emiss?es de gases poluentes produzidos pela combust?o (CO, NOx, SO2 e HC) atenderam aos limites estabelecidos pela resolu??o ambiental n? 382/ 2006 do CONAMA.

Page generated in 0.084 seconds